• Title/Summary/Keyword: Bias stability

Search Result 271, Processing Time 0.023 seconds

A comparison study on the estimation of the relative risk for the unemployed rate in small area (소지역의 실업률에 대한 상대위험도의 추정에 관한 비교연구)

  • Park, Jong-Tae
    • Journal of the Korean Data and Information Science Society
    • /
    • v.20 no.2
    • /
    • pp.349-356
    • /
    • 2009
  • In this study, we suggest the estimation method of the relative risk for the unemployment statistics of a small area such as si, gun, gu in Korea. The considered method are the usual pooled estimator, weighted estimator with the inverse of log-variance as weights, and the Jackknife estimator. And we compare with the efficiency of the three estimators by estimating the bias and mean square errors using real data from the 2002 Economically Active Population Survey of Gyeonggi-do. We compute the unemployed rate of male and female in small areas, and then estimate the common relative risk for the unemployed rate between male and female. Also, the stability and reliability of the three estimators for the common relative risk was evaluated using the RB(relative bias) and the RRMSE(relative root mean square error) of these estimators. Finally, the Jackknife estimator turned out to be much more efficient than the other estimators.

  • PDF

A Study on Implementation and Performance Evaluation of Wideband Receiver for the INMARSAT-B Satellite Communications System (INMARSAT-B형 위성통신용 광대역 수신단 구현 및 성능평가에 관한 연구)

  • 전중성;임종근;김동일;김기문
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.1
    • /
    • pp.166-172
    • /
    • 2001
  • A RF wideband receiver for INMARSAT-B satellite communications system was composed of low noise amplifier and high gain amplifier, The low noise amplifier used to the resistive decoupling circuit for input impedance matching and self-bias circuits for low noise. The high gain amplifier consists of matched amplifier type to improve receiver gain. The active bias circuit can be used to provide temperature stability without requiring the large voltage drop or relatively high-dissipated power needed with a bias stabilization resistor. The bandpass filter was used to reduce a spurious level. As a result, the characteristics of the receiver implemented here show more than 60 dB in gain and less than 1.8:1 in input and output voltage standing wave ratio(VSWR), especially the carrier to noise ratio which is input signal level -126.7 dB m at 1537.5 MHz is a 45.23 dB /Hz at a 1.02 kHz.

  • PDF

Annealing temperature dependence on the positive bias stability of IGZO thin-film transistors

  • Shin, Hyun-Soo;Ahn, Byung-Du;Rim, You-Seung;Kim, Hyun-Jae
    • Journal of Information Display
    • /
    • v.12 no.4
    • /
    • pp.209-212
    • /
    • 2011
  • The threshold voltage shift (${\Delta}V_{th}$) under positive-voltage bias stress (PBS) of InGaZnO (IGZO) thin-film transistors (TFTs) annealed at different temperatures in air was investigated. The dramatic degradation of the electrical performance was observed at the sample that was annealed at $700^{\circ}C$. The degradation of the saturation mobility (${\mu}_{sat}$) resulted from the diffusion of indium atoms into the interface of the IGZO/gate insulator after crystallization, and the degradation of the subthreshold slope (S-factor) was due to the increase in the interfacial and bulk trap density. In spite of the degradation of the electrical performance of the sample that was annealed at $700^{\circ}C$, it showed a smaller ${\Delta}V_{th}$ under PBS conditions for $10^4$ s than the samples that were annealed at $500^{\circ}C$, which is attributed to the nanocrystal-embedded structure. The sample that was annealed at $600^{\circ}C$ showed the best performance and the smallest ${\Delta}V_{th}$ among the fabricated samples with a ${\mu}_{sat}$ of $9.38cm^2/V$ s, an S-factor of 0.46V/decade, and a ${\Delta}V_{th}$ of 0.009V, which is due to the passivation of the defects by high thermal annealing without structural change.

Assessment of Turbulent Spectral Estimators in LDV (LDV의 난류 스펙트럼 추정치 평가)

  • 이도환;성형진
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.9
    • /
    • pp.1788-1795
    • /
    • 1992
  • Numerical simulations have been performed to investigate various spectral estimators used in LDV signal processing. In order to simulate a particle arrival time statistics known as the doubly stochastic poisson process, an autoregressive vector model was adopted to construct a primary velocity field. The conditional Poisson process with a random rate parameter was generated through the rescaling time process using the mean value function. The direct transform based on random sampling sequences and the standard periodogram using periodically resampled data by the sample and hold interpolation were applied to obtain power spectral density functions. For low turbulent intensity flows, the direct transform with a constant Poisson intensity is in good agreement with the theoretical spectrum. The periodogram using the sample and hold sequences is better than the direct transform in the view of the stability and the weighting of the velocity bias for high data density flows. The high Reynolds stress and high fluctuation of the transverse velocity component affects the velocity bias which increases the distortion of spectral components in the direct transform.

Magnetization Process in Vortex-imprinted Ni80Fe20/Ir20Mn80 Square Elements

  • Xu, H.;Kolthammer, J.;Rudge, J.;Girgis, E.;Choi, B.C.;Hong, Y.K.;Abo, G.;Speliotis, Th.;Niarchos, D.
    • Journal of Magnetics
    • /
    • v.16 no.2
    • /
    • pp.83-87
    • /
    • 2011
  • The vortex-driven magnetization process of micron-sized, exchange-coupled square elements with composition of $Ni_{80}Fe_{20}$ (12 nm)/$Ir_{20}Mn_{80}$ (5 nm) is investigated. The exchange-bias is introduced by field-cooling through the blocking temperature (TB) of the system, whereby Landau-shaped vortex states of the $Ni_{80}Fe_{20}$ layer are imprinted into the $Ir_{20}Mn_{80}$. In the case of zero-field cooling, the exchange-coupling at the ferromagnetic/antiferromagnetic interface significantly enhances the vortex stability by increasing the nucleation and annihilation fields, while reducing coercivity and remanence. For the field-cooled elements, the hysteresis loops are shifted along the cooling field axis. The loop shift is attributed to the imprinting of displaced vortex state of $Ni_{80}Fe_{20}$ into $Ir_{20}Mn_{80}$, which leads to asymmetric effective local pinning fields at the interface. The asymmetry of the hysteresis loop and the strength of the exchange-bias field can be tuned by varying the strength of cooling field. Micromagnetic modeling reproduces the experimentally observed vortex-driven magnetization process if the local pinning fields induced by exchange-coupling of the ferromagnetic and antiferromagnetic layers are taken into account.

A Study on the Low-Cost Fiber-Optic Gyroscope Using the Single Mode Fiber and Depolarizer (단일모드 광섬유와 편광소멸기를 이용한 저가형 광섬유 자이로스코프에 관한 연구)

  • Jang, Nam-Young;Ham, Hyung-Jae;Song, Hui-Young;Chio, Pyung-Suk;Eun, Jae-Jeong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.9 no.3
    • /
    • pp.179-187
    • /
    • 2008
  • In this paper, we carried out the performance evaluation of depolarized fiber optic gyroscope(D-FOG) that was designed and fabricated with the low-cost optical communication single mode fiber and depolarizer. In order to reduce the phase error of D-FOG, the circuit of stabilized current and temperature of the light source was made and the performance was analyzed. The current and the temperature stability of the fabricated stabilization circuit were less than $200{\mu}A$ and $0.0098^{\circ}C$, respectively. Also, the D-FOG's experimental result showed that the value of the dynamic range of rotated rate, the scale factor error with a good linearity, and the zero bias drift were ${\pm}50^{\circ}/s$, 2.8881%, and $19.49^{\circ}/h$, respectively. The results indicated that a low-cost FOG was able to fabricate which was more cost effective than conventional FOG with a high-cost high-birefringent polarization maintaining fiber.

  • PDF

Sampling Bias of Discontinuity Orientation Measurements for Rock Slope Design in Linear Sampling Technique : A Case Study of Rock Slopes in Western North Carolina (선형 측정 기법에 의해 발생하는 불연속면 방향성의 왜곡 : 서부 North Carolina의 암반 사면에서의 예)

  • 박혁진
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.1
    • /
    • pp.145-155
    • /
    • 2000
  • Orientation data of discontinuities are of paramount importance for rock slope stability studies because they control the possibility of unstable conditions or excessive deformation. Most orientation data are collected by using linear sampling techniques, such as borehole fracture mapping and the detailed scanline method (outcrop mapping). However, these data, acquired by the above linear sampling techniques, are subjected to bias, owing to the orientation of the sampling line. Even though a weighting factor is applied to orientation data in order to reduce this bias, the bias will not be significantly reduced when certain sampling orientations are involved. That is, if the linear sampling orientation nearly parallels the discontinuity orientation, most discontinuities orientation data which are parallel to sampling line will be excluded from the survey result. This phenomenon can cause serious misinterpretation of discontinuity orientation data because critical information is omitted. In the case study, orientation data collected by using the borehole fracture mapping method (vertical scanline) were compared to those based on orientation data from the detailed scanline method (horizontal scanline). Differences in results for the two procedures revealed a concern that a representative orientation of discontinuities was not accomplished. Equal-area, polar stereo nets were used to determine the distribution of dip angles and to compare the data distribution fur the borehole method versus those for the scanline method.

  • PDF

Atomic Layer Deposited ZrxAl1-xOy Film as High κ Gate Insulator for High Performance ZnSnO Thin Film Transistor

  • Li, Jun;Zhou, You-Hang;Zhong, De-Yao;Huang, Chuan-Xin;Huang, Jian;Zhang, Jian-Hua
    • Electronic Materials Letters
    • /
    • v.14 no.6
    • /
    • pp.669-677
    • /
    • 2018
  • In this work, the high ${\kappa}$ $Zr_xAl_{1-x}O_y$ films with a different Zr concentration have been deposited by atomic layer deposition, and the effect of Zr concentrations on the structure, chemical composition, surface morphology and dielectric properties of $Zr_xAl_{1-x}O_y$ films is analyzed by Atomic force microscopy, X-ray diffraction, X-ray photoelectron spectroscopy and capacitance-frequency measurement. The effect of Zr concentrations of $Zr_xAl_{1-x}O_y$ gate insulator on the electrical property and stability under negative bias illumination stress (NBIS) or temperature stress (TS) of ZnSnO (ZTO) TFTs is firstly investigated. Under NBIS and TS, the much better stability of ZTO TFTs with $Zr_xAl_{1-x}O_y$ film as a gate insulator is due to the suppression of oxygen vacancy in ZTO channel layer and the decreased trap states originating from the Zr atom permeation at the $ZTO/Zr_xAl_{1-x}O_y$ interface. It provides a new strategy to fabricate the low consumption and high stability ZTO TFTs for application.

Measurement Delay Error Compensation for GPS/INS Integrated System (GPS/INS 통합시스템의 측정치 시간지연오차 보상)

  • Lyou Joon;Lim You-Chol
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.41 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • The INS(Inertial Navigation System) provides high rate position, velocity and attitude data with good short-term stability while the GPS(Global Position System) provides position and velocity data with long-term stability. By integrating the INS with GPS, a navigation system can be achieved to Provide highly accurate navigation Performance. For the best performance, time synchronization of GPS and INS data is very important in GPS/INS integrated system But, it is impossible to synchronize them exactly due to the communication and computation time-delay. In this paper, to reduce the error caused by the measurement time-delay in GPS/INS integrated systems, error compensation methods using separate bias Kalman filter are suggested for both the loosely-coupled and the tightly-coupled GPS/INS integration systems. Linearized error models for the position and velocity matching GPS/INS integrated systems are Int derived by linearizing with respect to its time-delay and augmenting the delay-state into the conventional state equations for each case. And then separate bias Kalman Inter is introduced to estimate the time-delay during only initial navigation stage. The simulation results show that the present method is effective enough resulting in considerably less position error.

Fabrication of New Silicided Si Field Emitter Array with Long Term Stability (실리사이드를 이용한 새로운 고내구성 실리콘 전계방출소자의 제작)

  • Chang, Gee-Keun;Yoon, Jin-Mo;Jeong, Jin-Cheol;Kim, Min-Young
    • Korean Journal of Materials Research
    • /
    • v.10 no.2
    • /
    • pp.124-127
    • /
    • 2000
  • A new triode type Ti-silicided Si FEA(field emitter array) was realized by Ti-silicidation of Ti coated Si FEA and its field emission properties were investigated. In the fabricated device, the field emission properties through the unit pixel with $200{\mu\textrm{m}}{\times}200{$\mu\textrm{m}}$ tip array in the area of $1000{\mu\textrm{m}}{\times}1000{$\mu\textrm{m}}$ were as follows : the turn-on voltage was about 70V under high vacuum condition of $10^8Torr$, and the field emission current and steady state current degradation were about 2nA/tip and 0.3%/min under the bias of $V_A=500V\;and\;V_G=150V$. The low turn-on voltage and the high current stability during long term operation of the Ti silicided Si FEA were due to the thermal and chemical stability and the low work function of silicide layer formed at the surface of Si tip.

  • PDF