• Title/Summary/Keyword: Automatic Testing Equipment

Search Result 60, Processing Time 0.025 seconds

Efficient Multi-site Testing Using ATE Channel Sharing

  • Eom, Kyoung-Woon;Han, Dong-Kwan;Lee, Yong;Kim, Hak-Song;Kang, Sungho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.3
    • /
    • pp.259-262
    • /
    • 2013
  • Multi-site testing is considered as a solution to reduce test costs. This paper presents a new channel sharing architecture that enables I/O pins to share automatic test equipment (ATE) channels using simple circuitry such as tri-state buffers, AND gates, and multiple-input signature registers (MISR). The main advantage of the proposed architecture is that it is implemented on probe cards and does not require any additional circuitry on a target device under test (DUT). In addition, the proposed architecture can perform DC parametric testing of the DUT such as leakage testing, even if the different DUTs share the same ATE channels. The simulation results show that the proposed architecture is very efficient and is applicable to both wafer testing and package testing.

Integrated Railway Signaling Systems for Laboratory Testing of Next-generation High-speed Train (한국형 고속전철용 신호시스템의 실험실 시험을 위한 통합 신호시스템)

  • Hwang, Jong-Gyu;Lee, Jong-Woo;Park, Yong-Jin
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.1
    • /
    • pp.32-39
    • /
    • 2004
  • Railway signaling systems consist of several vital computerized equipment such as CTC(Centralized Traffic Control), EIS(Electronic Interlocking System), ATC(Automatic Train Control) and so on. Currently, the project for development of railway signaling systems for the next-generation high-speed train is progressed according to the G7 project and railway signaling related several companies and research institute are joined this project consortium. The railway signaling systems, being developed in this project, called as a kTCS(Korean Train Control System), is composed of kTCS-CTC, kTCS-IXL, kTCS-ATC and etc. kTCS signaling systems have to be operated at the laboratory testing level as integrated signaling systems by interface between each railway signaling systems before railway field installation and revenue service. To solve this matter, communication protocols between each signaling equipment are designed and message codes for each defined protocols have defined. And also several equipment has developed for the railway integrated signaling systems for laboratory testing. We has plentifully tested and verified the designed protocols and the characteristics of integrated railway signaling systems with our developed each kTCS signaling equipment and communication protocols. In this paper, the integrated kTCS system including communication protocols is presented.

Development of Automatic Shear-wave Source for Downhole Seismic Method (다운홀 탄성파 기법용 전단파 자동 가진원의 개발)

  • Bang, Eun-Seok;Sung, Nak-Hoon;Kim, Jung-Ho;Kim, Dong-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.11
    • /
    • pp.27-37
    • /
    • 2007
  • Downhole seismic method is very economic and easy to operate because it uses only one borehole and simple surface source to obtain the shear wave velocity profile of a site. In this study, automatic shear wave source was developed for efficient downhole seismic testing. This source is motor-spring type and easy to control. It can lessen the labor of operator and the working time. Moreover, it can provide better and repetitive signals for data interpretation. By combining developed automatic source with automatic receiver system, PC based data acquisition system, advanced managing program, and semi-automatic downhole performing system were constructed. Through comparison test with manual source, advantages of automatic source were verified. Constructed semi-automatic downhole testing system including automatic shear wave source was applied to the soft soil site. The applicability and reliability were verified and the importance of automating testing system for obtaining reliable result was emphasized.

Design and Implementation of the Automatic cable assembly test system that can test cable assembly effectively

  • Jang, Ki-Mang
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.7
    • /
    • pp.1-10
    • /
    • 2018
  • In this paper, we propose the principles and design details of Automatic cable assembly test system and show its utility. Testing the cable assembly is required periodically or non-periodically in the system that the cable assembly performance is quite important like military equipment. There are several weaknesses when humans test the cable assembly manually. It not only takes much time but also could happen human error. To improve these disadvantages, I developed Automatic cable assembly test system. The system can be implemented by building switching control system that connect and disconnect the cable assembly and measuring devices. Through the result of the cable assembly test with this test system, we show this system makes test time short and improves of test reliability as compared with manual test.

Development of Automatic Remote Exposure Controller for Gamma Radiography (감마선투과검사 장치의 자동 원격조작기 개발)

  • Joo, Gwang-Tae;Shin, Jin-Seong;Kim, Dong-Eun;Song, Jung-Ho;Choo, Seung-Hwan;Chang, Hong-Keun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.5
    • /
    • pp.490-499
    • /
    • 2002
  • Recently, gamma radiographic equipments have been used about 1,000 sets manually and operated by about 2,500 persons in Korea. In order for a radiography to work effectively with avoiding any hazard of the high level radiation from the source, many field workers have expected developing a wireless automatic remote exposure controller. The KlTCO research team has developed an automatic remote exposure controller that can regulate the speed of $0.4{\sim}1.2m/s$ by BLDC motor of 24V 200W which has output of $54kgf{\cdot}cm$, suitable torque and safety factor for the work. And the developed automatic remote exposure controller can control rpm of motor, pigtail position by photo-sensor and exposure time by timer to RF sensor. Thus, the developed equipment is expected that the unit can be used in many practical applications with benefits in economical advantage to combine the use of both automatic and manual type because attachment is possible existent manual remote exposure controller, AC and DC combined use.

Development of Automatic Ultrasonic Testing Equipment for Pressure-Retaining Studs and Bolts in Nuclear Power Plant (원자력 발전소 STUD BOLT의 자동초음파 주사장치 개발)

  • Suh, D.M.;Park, M.H.;Hong, S.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.9 no.1
    • /
    • pp.106-110
    • /
    • 1989
  • Bolting degradation problems in primary coolant pressure boundary applications have become a major concern in the nuclear industry. In the bolts concerned, the failure mechanism was either corrosion wastage(loss of bolt diameter) or stress-corrosion cracking.(3) Here the manual ultrasonic testing of RPV(Reactor Pressure Vessel) and RCP(Reactor Coolant Pump) stud has been performed. But it is difficult to detect indications because examiner can not exactly control the rotation angle and can not distinguish the indication from signals of bolt. In many cases, the critical sizes of damage depth are very small(1-2 mm order). At critical size, the crack tends to propagatecompletly through the bolt under stress, Resulting in total fracture.(3) Automatic stud scanner for studs(bolts) was developed because the precise measurement of bolt diameter is required in this circumstance. By use of this scanner, the rotation angle of probe was exactly controlled and the exposure time of radiations was reduced.

  • PDF

A new efficient algorithm for test pattern compression considering low power test in SoC (SoC환경에서의 저전력 테스트를 고려한 테스트 패턴 압축에 대한 효율적인 알고리즘)

  • 신용승;강성호
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.9
    • /
    • pp.85-95
    • /
    • 2004
  • As the design complexity increases, it is a major problem that the size of test pattern is large and power consumption is high in scan, especially system-on-a-chip(SoC), with the automatic test equipment(ATE). Because static compaction of test patterns heads to higher power for testing, it is very hard to reduce the test pattern volume for low power testing. This paper proposes an efficient compression/decompression algorithm based on run-length coding for reducing the amount of test data for low power testing that must be stored on a tester and be transferred to SoC. The experimental results show that the new algorithm is very efficient by reducing the memory space for test patterns and the hardware overhead for the decoder.

Design of Test Access Mechanism for AMBA based SoC (AMBA 기반 SoC 테스트를 위한 접근 메커니즘 설계)

  • Min, Pil-Jae;Song, Jae-Hoon;Yi, Hyun-Bean;Park, Sung-Ju
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.10 s.352
    • /
    • pp.74-79
    • /
    • 2006
  • Test Interface Controller (TIC) provided by ARM Ltd. is widely used for functional testing of System-on-Chip (SoC) adopting Advanced Microcontroller Bus Architecture (AMBA) bus system. Accordingly, this architecture has a deficiency of not being able to concurrently shifting in and out the structural scan test patterns through the TIC and AMBA bus. This paper introduces a new AMBA based Test Access Mechanism (ATAM) for speedy testing of SoCs embedding ARM cores. While preserving the compatability with the ARM TIC, since scan in and out operations can be performed simultaneously, test application time through the expensive Automatic Test Equipment (ATE) can be drastically reduced.

A Study on Automatic Test Equipment Validation in the Realm of Defense (국방 분야 자동화시험장비 유효성 확인 방안에 관한 연구)

  • Pak, Se-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.9
    • /
    • pp.144-150
    • /
    • 2020
  • This study examined the current status of ATE in the development stage of the domestic guided weapons field, including the re-establishment of automatic test equipment (ATE), and attempted to develop methods to verify the validity of ATE in the defense sector. This study includes methods for confirming the repeatability and reproducibility of newly manufactured or replaced ATE. An error injection test is required for validation in the development phase. And pre-inspection steps are required for validation. When developing ATE, the use of an international standard testing script language ensures efficient validation and SW reliability. This ensures interoperability between the main and test equipment, and the tester can secure a test system platform that supports standardized testing methods, which is considered to be effective in validating specific ATE for each weapon system.

Development of Integrated Test Equipment for Airborne SAR System and Control Unit (항공탑재 SAR 시스템 및 통제장치 시험을 위한 통합시험장비 개발)

  • Lee, Hyon-Ik;Hwang, Tae-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.9
    • /
    • pp.747-754
    • /
    • 2013
  • This paper describes SCTE(System and Control unit Test Equipment) as an integrated test equipment for airborne SAR system and control unit. SCTE enhances reusability of test equipment by modular design for required functions and strengthens automatic testing and test convenience by providing functions such as script-based testing function and report generation function. Also, it includes a navigation data simulator which can simulate various flight conditions. In this paper, we details SCTE requirements, H/W and S/W design, implementation, and test results with control unit and SAR system.