• Title/Summary/Keyword: All electric range

Search Result 170, Processing Time 0.024 seconds

Precision Control of Water Bath Temperature using Air Cooled Variable Refrigerant Flow Chiller (공랭식 변유량 냉매 냉동기를 적용한 수조 온도의 정밀 제어)

  • Jeong, Kwang-Ju;Kim, Young Il
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.14 no.4
    • /
    • pp.27-34
    • /
    • 2018
  • This study compared constant water bath performances of conventional water-cooled refrigerator and electric heater with an air-cooled VRF chiller and electric heater equipped with optimal control algorithm. In heating mode, the air cooled VRF chiller and electric heater combination reduced the set temperature arrival time by an average of 42 minutes, and energy was also reduced by 18%. In cooling mode, the two systems took 70 minutes to reach the set temperature and showed no difference. Energy was reduced by 33.5% with the new system. For constant temperature maintaining experiment, after reaching the set temperature of $15^{\circ}C$, $20^{\circ}C$ and $22^{\circ}C$, temperature deviations were all in the range of $-0.2^{\circ}C$ to $+0.1^{\circ}C$. Energy was reduced by an average of 84.9%. Through this study, possibility of precise temperature control by an air cooled VRF chiller system was confirmed.

Design and Implementation of Optical Signal Processor in Fiber-Optic Current Transducer for Electric Equipments (전력기기용 고안정성 광섬유 CT 센서의 광 신호처리기 설계 및 구현)

  • Jang, Nam-Young;Choi, Pyung-Suk;Eun, Jae-Jeong;Cheong, Hyeon-Seong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.8 no.3
    • /
    • pp.171-177
    • /
    • 2007
  • In this paper, we have designed and implemented an optical signal processor in order to use in a fiber-optic current CT for electric equipments where its properties were discussed. The fabricated optical signal processor is used to reduce a measurement current error that induced by the effects of intensity variation in the optical output signal due to losses coming from optical components or polarization variation in a PFOCS. Also, the optical signal processor was fabricated in compact/lightweight with unification of opto-electronic transducer part, analog signal process part, and real-time measurement part consisted of a level shift and ${\mu}-processor$. The experiment of optical signal processor has been performed in the range of $0{\sim}7,500A$ using the PFOCS made all fiber-optic components. As a result of experiment, the linearity error of measurement current is less than 1.7% and its average error is less than 0.3% in the range of $1,000A{\sim}7,000A$.

  • PDF

Design Verification of an E-driving System of a 44 kW-class Electric Tractor using Agricultural Workload Data (농작업 부하데이터를 활용한 44 kW급 전기구동 트랙터의 E-driving 시스템 설계 검증)

  • Baek, Seung-Yun;Baek, Seung-Min;Jeon, Hyeon-Ho;Lee, Jun-Ho;Kim, Wan-Soo;Kim, Yong-Joo
    • Journal of Drive and Control
    • /
    • v.19 no.4
    • /
    • pp.36-45
    • /
    • 2022
  • The aim of this study was to verify an E-driving system of a 44 kW-class electric tractor using agricultural workload data. Workload data were acquired during field test (plow tillage, rotary tillage, loader operation, field driving, asphalt driving) using a conventional tractor with a load measurement system. These workload data were converted to data of a 44 kW-class tractor based on the load factor of the engine. These data were used to verify the design of the E-driving system of an electric tractor. High-load operations such as plow tillage, rotary tillage, and loader operation could be performed at stage L and stage M. High-speed operation (asphalt driving) could be effectively performed at stage H using a rated rotational speed of the motor. As a result, the E-driving system of the electric tractor was possible to perform all major agricultural operations according to gear stages of range shift. Based on results of this research, we plan to develop an electric tractor equipped with an E-driving system and conduct research on actual vehicle verification in the future.

A Characteristics of Zn-Al-Cu System Pb-free Solder Alloys for Ultra High Temperature Applications (초고온용 Zn-Al-Cu계 Pb-free 솔더 합금의 특성)

  • Kim Seong-Jun;Na Hye-Seong;Han Tae-Kyo;Lee Bong-Keun;Kang Cung-Yun
    • Journal of Welding and Joining
    • /
    • v.23 no.6
    • /
    • pp.93-98
    • /
    • 2005
  • The purpose of this study is to investigate the characteristics of pb-free $Zn-(3\~6)\%Al-(1\~6)\%Cu$ solder alloys for ultra high temperature(>573K) which applied to air craft, space satellite, automotive, oil, gas well exploration and data logging of geo-thermal wells. Melting range, solderability, electric resistivity, microstructure and mechanical properties were examined with solder alloys casted in Ar gas atmosphere. $Zn-4\%Al-(1\~3)\%Cu,\;Zn-5\%Al-(2\~4)\%Cu\;and\;Zn-6\%Al-(3\~5)\%Cu$ alloys satisfied the optimum melting range of 643 to 673k for ultra high temperature solder. A melting temperature increased with increasing Cu content, but decreased with increasing Al content. The spreadability was improved with increasing hi content. But the content of Cu had no effect on the spreadability. The electric resistivity was lowered with increasing Al and decreasing Cu content. In all Zn-Al-Cu solder alloys, primary dendritic $\varepsilon$ phase(Zn-Cu), dendritic $\eta$ phase(Zn-Cu-Al), $\alpha(Al-Zn)-\eta$ eutectic and eutectoid phase were observed. The addition of Al increased the volume fraction of eutectic and eutectoid phase and it decreased f phases. Also, the addition of Cu increased slightly the volume fraction of e, the eutectic and eutectoid phases. With increasing total content of Al and Cu, a hardness and a tensile strength were linearly increased, but anelongation was linearly decreased.

Implementation of a ZVS Three-Level Converter with Series-Connected Transformers

  • Lin, Bor-Ren
    • Journal of Power Electronics
    • /
    • v.13 no.2
    • /
    • pp.177-185
    • /
    • 2013
  • This paper studies a soft switching DC/DC converter to achieve zero voltage switching (ZVS) for all switches under a wide range of load condition and input voltage. Two three-level PWM circuits with the same power switches are adopted to reduce the voltage stress of MOSFETs at $V_{in}/2$ and achieve load current sharing. Thus, the current stress and power rating of power semiconductors at the secondary side are reduced. The series-connected transformers are adopted in each three-level circuit. Each transformer can be operated as an inductor to smooth the output current or a transformer to achieve the electric isolation and power transfer from the input side to the output side. Therefore, no output inductor is needed at the secondary side. Two center-tapped rectifiers connected in parallel are used at the secondary side to achieve load current sharing. Due to the resonant behavior by the resonant inductance and resonant capacitance at the transition interval, all switches are turned on at ZVS. Experiments based on a 1kW prototype are provided to verify the performance of proposed converter.

Analysis on the Electric Properties of TFT-LCDs (TFT-LCD의 전기적 특성 연구)

  • Kim, Myoung-Chul
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.4
    • /
    • pp.368-375
    • /
    • 2008
  • In this paper, we calculated the pixel and all the inter-electrode capacitances in a unit pixel of three kinds of TFT-LCD modes in order to realize the full color image. And we analyzed the effect on applied voltage. We fixed size of sub-pixel and designed a unit pixel of three kinds of TFT-LCD modes. We calculated rigorously the pixel and all the inter-electrode capacitances by the three dimensional simulation. And we expanded one pixel into whole panel using H-SPICE. As a result, we calculated the RMS voltage and kickback voltage which most affect gray scale of the pixel and calculated the number of bit according to permissible range of minimum gray scale using V-T curve.

The formation of N-Nitrosamine in Commercial Cured Products 2. The effect of cooking methods on N-Nitrosamine formation in commercial Ham and Sausages (시판 식육제품 중 N-Nitrosamine의 생성 제2보. 조리방법이 햄 및 소시지의 N-Nitrosamine 생성에 미치는 영향)

  • 박계란;이수정;신정혜;성낙주;임상선
    • Journal of Food Hygiene and Safety
    • /
    • v.13 no.4
    • /
    • pp.406-411
    • /
    • 1998
  • Representive cured products such as ham and sausage produced in Korea were purchased at retail and cooked using heating tools such as a gas range (GR), an electric range (ER) and electric range after boiled (BE). Changes of N-nitrosamine (NA), nitrate and nitrite in the cured meats containing< $2.0\;\mu\textrm{g}/kg$ of N-nitrosodimethylamine (NDMA) were checked and analyzed during their cooking process. Contents of nitrate and nitrite in ham products prior to cooking were 2.0 and 1.8 mg/kg, respectively; their contents in regular hams were slightly increased, but those of nitrate in press hams were decreased while those of nitrite were increased during its cooking process. Their contents in sausage products were 1.8 and 0.9 mg/kg; those of nitrate were decreased, while nitrite were slightly increased during its cooking process. NDMA detected only NA in all the collected cured products. Changes of NDMA, regardless of cooking methods, tend to drastically increase in all samples after their cooking; Its contents were increased by average 6.0~70.7 times in the GR samples, by average 2.4~39.2 times in the ER samples and by average 7.0~56.3 times in the BE samples. Virtually, the fact that all of this nitrosamine appeared to arise by the action of precursor such as NOx was produced during the cooking of cured products.

  • PDF

Properties of the $\beta-SiC-TiB_2$ Composites with $Al_2O_3+Y_2O_3$ additives ($Al_2O_3+Y_2O_3를 첨가한 {\beta}-SiC-TiB_2$ 복합체의 특성)

  • Yim, Seung-Hyuk;Shin, Yong-Deok;Ju, Jin-Young;Yoon, Se-Won;Song, Joon-Tae
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.7
    • /
    • pp.394-399
    • /
    • 2000
  • The mechanical and electrical properties of pressed and annealed $\beta-SiC-TiB_2$ electroconductive ceramic composites were investigated as a function of the liquid forming additives of $Al_2O_3+Y_2O_3$. Phase analysis of composites by XRD revealed $\alpha$-SiC(6H), TiB2, and (Al5Y3O12). Reaction between Al2O3 and $Y_2O_3$ formed YAG but the relative density decreased with increasing $Al_2O_3+Y_2O_3$ contents. The Flexural strength showed the value of 458.9 MPa for composites added with 4 wt% $Al_2O_3+Y_2O_3$ additives at room temperatures. Owing to crack deflection and crack bridging, the fracture toughness showed 6.2, 6.0 and 6.6 MPa.m1/2 for composites added with 4, 8 and 12 wt% Al2O3+Y2O3 additives respectively at room temperature. The resistance temperature coefficient showed the value of $3.6\times10^{-3},\; 2.9\times10^{-3}\; and\; 3.0\times10^{-3} /^{\circ}C$$^{\circ}C$ for composite added with 4, 8 and 12 wt% $Al_2O_3+Y_2O_3$additives respectively at room temperature. The electrical resistivity of the composites was all positive temperature coefficient resistance(PTCR) in the temperature range of $25^{\circ}C\; to\; 700^{\circ}$.

  • PDF

An Early Experience of Electroejaculation in Anejaculatory Men with Spinal Cord Injury (척수손상 환자에 대한 전기자극 인공사정의 초기 경험)

  • Kang, Il-Gyu;Cho, Myoung-Kwan;Oh, Chung-Hwan;Moon, Young-Tae;Kim, Sae-Chul;Choi, Jong-Han
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.19 no.1
    • /
    • pp.87-94
    • /
    • 1992
  • From December 1991 to March 1992, 34 anejacuratory patients with spinal cord injury underwent 90 of electric stimulations with Seager NRH model 12. The average patient age was 43.5 years with a range of 23 to 48 years. The level of cord injury was cervical in 7, thoracic in 6, lumbar in 11, lumbosacral in 7 and conus medullaris in 3. The average number of electric stimulation per a patient was 2.65 with a range of 1 to 4. The average voltage and amplitude per a stimulation were 17.72 volts and 309. 89 mAmp with ranges of 5 to 25 volts and 50 to 500 mAmp. The total and motile sperm number were evaluated microscopically and analyzed statistically by paired t-test according to the frequency of electroejaculation, level of cord injury and voiding pattern. The results were obtained as follows. 1. An overall success rate of electroejaculation was 85.3% among 34 patients and 82.2% among 90 electric stimulations. 2. The total and motile sperm number per a stimulation were not correlated the frequency of electric stimulation, level of cord injury and voiding pattern. 3. Complications occured in 10 cases; severe low abdominal pain in 5, hypertension in 2, sweating in 1, headache in 1 and neck stiffness in 1. All the copmlications subsided spontaneously within 5 to 10 minutes after transient interruption of the electric stimulation. In summary, rectal probe electroejaculation is an accepted safe means of procuring sperm from spinal cord injury patients with ejaculatory incompetence. However very poor sperm motility was found and it was not related with the frequency of electroejaculation, level of cord injury and voiding pattern. Further investigation would be needed to conclude and to identify the reasons for impaired sperm motility.

  • PDF

Implementation of Leakage Monitoring System Using ZigBee (ZigBee를 적용한 누전상태 모니터링시스템 구현)

  • Ju, Jae-han;Na, Seung-kwon
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.1
    • /
    • pp.107-112
    • /
    • 2017
  • In recent years, electric shock accidents due to electric leakage currents of household appliances such as computers, TVs, refrigerators, and LED lights are continuously occurring in homes and industrial buildings. And it is not easy to check the leakage current of each household appliances connected in parallel at the rear end of the module. In addition, the leakage current flowing through the path of the normal current other than the existing current leakage circuit breakers are installed in the distribution box, only the function to cut off the power when the leakage. Therefore, there are various disasters such as electric shock and fire caused by short circuit of household appliances, and the risk of such leakage current is seriously presented. In this paper, we propose a method to implement a leakage monitoring system that can be monitored at all times using Zigbee communication based on IEEE 80215.4, which has advantages in low power and low cost among short range wireless communication systems.