• 제목/요약/키워드: Al anodization

검색결과 52건 처리시간 0.027초

PbSCC of Ni-base Alloys in PbO-added Pure Water

  • Kim, Joung Soo;Yi, Yong-Sun;Kwon, Oh Chul;Kim, Hong Pyo
    • Corrosion Science and Technology
    • /
    • 제6권6호
    • /
    • pp.316-321
    • /
    • 2007
  • The effect of annealing on the pitting corrosion resistance of anodized Al-Mg alloy (AA5052) processed by equal-channel angular pressing (ECAP) was investigated by electrochemical techniques in a solution containing 0.2 mol/L of $AlCl_3$ and also by surface analysis. The Al-Mg alloy was annealed at a fixed temperature between 473 and 573 K for 120 min in air after ECAP. Anodizing was conducted for 40 min at $100-400A/m^2$ at 293 K in a solution containing 1.53 mol/L of $H_2SO_4$ and 0.0185 mol/L of $Al_2(SO_4)_3$. The internal stress generated in anodic oxide films during anodization was measured with a strain gauge to clarify the effect of ECAP on the pitting corrosion resistance of anodized Al-Mg alloy. The time required to initiate the pitting corrosion of anodized Al-Mg alloy was shorter in samples subjected to ECAP, indicating that ECAP decreased the pitting corrosion resistance. However, the pitting corrosion resistance was greatly improved by annealing after ECAP. The time required to initiate pitting corrosion increased with increasing annealing temperature. The strain gauge attached to Al-Mg alloy revealed that the internal stress present in the anodic oxide films was compressive stress, and that the stress was larger with ECAP than without. The compressive internal stress gradually decreased with increasing annealing temperature. Scanning electron microscopy showed that cracks occurred in the anodic oxide film on Al-Mg alloy during initial corrosion and that the cracks were larger with ECAP than without. The ECAP process of severe plastic deformation produces large internal stresses in the Al-Mg alloy; the stresses remain in the anodic oxide films, increasingthe likelihood of cracks. It is assumed that the pitting corrosion is promoted by these cracks as a result of the higher internal stress resulting from ECAP. The improvement in the pitting corrosion resistance of anodized AlMg alloy as a result of annealing appears to be attributable to a decrease in the internal stresses in anodic oxide films

Effect of Annealing on the Pitting Corrosion Resistance of Anodized Aluminum-Magnesium Alloy Processed by Equal Channel Angular Pressing

  • Son, In-Joon;Nakano, Hiroaki;Oue, Satoshi;Kobayashi, Shigeo;Fukushima, Hisaaki;Horita, Zenji
    • Corrosion Science and Technology
    • /
    • 제6권6호
    • /
    • pp.275-281
    • /
    • 2007
  • The effect of annealing on the pitting corrosion resistance of anodized Al-Mg alloy (AA5052) processed by equal-channel angular pressing (ECAP) was investigated by electrochemical techniques in a solution containing 0.2 mol/L of $AlCl_3$ and also by surface analysis. The Al-Mg alloy was annealed at a fixed temperature between 473 and 573 K for 120 min in air after ECAP. Anodizing was conducted for 40 min at $100-400A/m^2$ at 293 K in a solution containing 1.53 mol/L of $H_2SO_4$ and 0.0185 mol/L of $Al_2(SO_4)_3$. The internal stress generated in anodic oxide films during anodization was measured with a strain gauge to clarify the effect of ECAP on the pitting corrosion resistance of anodized Al-Mg alloy. The time required to initiate the pitting corrosion of anodized Al-Mg alloy was shorter in samples subjected to ECAP, indicating that ECAP decreased the pitting corrosion resistance. However, the pitting corrosion resistance was greatly improved by annealing after ECAP. The time required to initiate pitting corrosion increased with increasing annealing temperature. The strain gauge attached to Al-Mg alloy revealed that the internal stress present in the anodic oxide films was compressive stress, and that the stress was larger with ECAP than without. The compressive internal stress gradually decreased with increasing annealing temperature. Scanning electron microscopy showed that cracks occurred in the anodic oxide film on Al-Mg alloy during initial corrosion and that the cracks were larger with ECAP than without. The ECAP process of severe plastic deformation produces large internal stresses in the Al-Mg alloy; the stresses remain in the anodic oxide films, increasingthe likelihood of cracks. It is assumed that the pitting corrosion is promoted by these cracks as a result of the higher internal stress resulting from ECAP. The improvement in the pitting corrosion resistance of anodized AlMg alloy as a result of annealing appears to be attributable to a decrease in the internal stresses in anodic oxide films

Morphology of RF-sputtered Mn-Coatings for Ti-29Nb-xHf Alloys after Micro-Pore Form by PEO

  • Park, Min-Gyu;Park, Seon-Yeong;Choe, Han-Cheol
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2016년도 추계학술대회 논문집
    • /
    • pp.197-197
    • /
    • 2016
  • Commercially pure titanium (CP Ti) and Ti-6Al-4V alloys have been widely used for biomedical applications. However, the use of the Ti-6Al-4V alloy in biomaterial is then a subject of controversy because aluminum ions and vanadium oxide have potential detrimental influence on the human body due to vanadium and aluminum. Hence, recent works showed that the synthesis of new Ti-based alloys for implant application involves more biocompatible metallic alloying element, such as, Nb, Hf, Zr and Mo. In particular, Nb and Hf are one of the most effective Ti ${\beta}-stabilizer$ and reducing the elastic modulus. Plasma electrolyte oxidation (PEO) is known as excellent method in the biocompatibility of biomaterial due to quickly coating time and controlled coating condition. The anodized oxide layer and diameter modulation of Ti alloys can be obtained function of improvement of cell adhesion. Manganese(Mn) plays very important roles in essential for normal growth and metabolism of skeletal tissue in vertebrates and can be detected as minor constituents in teeth and bone. Radio frequency(RF) magnetron sputtering in the various PVD methods has high deposition rates, high-purity films, extremely high adhesion of films, and excellent uniform layers for depositing a wide range of materials, including metals, alloys and ceramics like a hydroxyapatite. The aim of this study is to research the Mn coatings on the micro-pore formed Ti-29Nb-xHf alloys by RF-magnetron sputtering for dental applications. Ti-29Nb-xHf (x= 0, 3, 7 and 15wt%, mass fraction) alloys were prepared Ti-29Nb-xHf alloys of containing Hf up from 0 wt% to 15 wt% were melted by using a vacuum furnace. Ti-29Nb-xHf alloys were homogenized for 2 hr at $1050^{\circ}C$. Each alloy was anodized in solution containing typically 0.15 M calcium acetate monohydrate + 0.02 M calcium glycerophosphate at room temperature. A direct current power source was used for the process of anodization. Anodized alloys was prepared using 270V~300V anodization voltage at room. Mn coatings was produced by RF-magnetron sputtering system. RF power of 100W was applied to the target for 1h at room temperature. The microstructure, phase and composition of Mn coated oxide surface of Ti-29Nb-xHf alloys were examined by FE-SEM, EDS, and XRD.

  • PDF

Surface Characteristics of Type II Anodized Ti-6Al-4V Alloy for Biomedical Applications

  • 이수원;정태곤;양재웅;정재영;박광민;정용훈
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2017년도 춘계학술대회 논문집
    • /
    • pp.77-77
    • /
    • 2017
  • Titanium and its alloys offer attractive properties in a variety of applications. These are widely used for the field of biomedical implants because of its good biocompatibility and high corrosion resistance. Titanium anodizing is often used in the metal finishing of products, especially those can be used in the medical devices with dense oxide surface. Based on SAE/AMS (Society of Automotive Engineers/Aerospace Material Specification) 2488D, it has the specification for industrial titanium anodizing that have three different types of titanium anodization as following: Type I is used as a coating for elevated temperature forming; Type II is used as an anti-galling coating without additional lubrication or as a pre-treatment for improving adherence of film lubricants; Type III is used as a treatment to produce a spectrum of surface colours on titanium. In this study, we have focused on Type II anodization for the medical (dental and orthopedic) application, the anodized surface was modified with gray color under alkaline electrolyte. The surface characteristics were analyzed with Focused Ion Beam (FIB), Scanning Electron Microscopy (SEM), surface roughness, Vickers hardness, three point bending test, biocompatibility, and corrosion (potentiodynamic) test. The Ti-6Al-4V alloy was used for specimen, the anodizing procedure was conducted in alkaline solution (NaOH based, pH>13). Applied voltage was range between 20 V to 40 V until the ampere to be zero. As results, the surface characteristics of anodic oxide layer were analyzed with SEM, the dissecting layer was fabricated with FIB method prior to analyze surface. The surface roughness was measured by arithmetic mean deviation of the roughness profile (Ra). The Vickers hardness was obtained with Vickers hardness tester, indentation was repeated for 5 times on each sample, and the three point bending property was verified by yield load values. In order to determine the corrosion resistance for the corrosion rate, the potentiodynamic test was performed for each specimen. The biological safety assessment was analyzed by cytotoxic and pyrogen test. Through FIB feature of anodic surfaces, the thickness of oxide layer was 1.1 um. The surface roughness, Vickers hardness, bending yield, and corrosion resistance of the anodized specimen were shown higher value than those of non-treated specimen. Also we could verify that there was no significant issues from cytotoxicity and pyrogen test.

  • PDF

Ti-6Al-4V 합금 표면에 생성된 $TiO_2$ 나노튜브의 전석회화 처리 (Precalcification Treatment of $TiO_2$ Nanotube on Ti-6Al-4V Alloy)

  • 김시정;박지만;배태성;박은진
    • 대한치과보철학회지
    • /
    • 제47권1호
    • /
    • pp.39-45
    • /
    • 2009
  • 연구목적: 최근 치과용 임플란트의 임상 경향이 전체 치료기간을 줄일 수 있는 방법에 관심이 집중됨에 따라 불활성의 티타늄 임플란트 표면에 활성을 부여하기 위한 다양한 표면처리 방법이 검토되고 있다. 본 연구에서는 높은 강도가 요구되는 부위의 임플란트 재료로서 사용되고 있지만 표면 특성이 순 티타늄에 비해 떨어지는 Ti-6Al-4V 합금의 골전도성을 개선할 목적으로 시행되었다. 연구 재료 및 방법: $20{\times}10{\times}2\;mm$의 Ti-6Al-4V 합금판을 준비한 다음 $TiO_2$ 나노튜브를 형성하기 위해 DC 정전원 장치의 양극과 음극에 각각 시편과 백금판을 결선하고 0.5 M $Na_2SO_4$와 1.0 wt% NaF를 함유하는 전해액을 사용하여 전압 20 V와 전류밀도 $30\;㎃/cm^2$ 조건에서 2시간 동안 양극산화 처리하였다. $TiO_2$ 나노튜브 형성 후 산화 피막층의 결정화를 유도하기 위해 $600^{\circ}C$에서 2시간 동안 열처리하였고, 표면활성도를 개선하기 위해 0.5 M $Na_2HPO_4$ 수용액 24시간 침적과 $Ca(OH)_2$ 포화 수용액에 5시간 침적을 시행하였다. 준비한 시편의 표면 반응성을 조사하기 위해 pH와 무기이온의 농도를 사람의 혈장과 유사하게 조절한 Hanks 용액 (H2387, Sigma Chemical Co., USA)에 2주간 침적하였다. 결과: 20 V에서의 양극산화처리로 직경 48.0 - 65.0 ㎚ 범위의 무정형의 $TiO_2$ 나노튜브가 전체 표면에 걸쳐서 균일하게 생성되는 양상을 보였다. $TiO_2$ 나노튜브는 $600^{\circ}C$에서 2시간 열처리 후 상대적으로 강한 anatase 피크와 함께 rutile 피크가 관찰되었다. $TiO_2$ 나노튜브의 표면활성도는 0.5 M $Na_2HPO_4$ 수용액 24시간 침적과 $Ca(OH)_2$ 포화수용액에 5시간 침적으로 개선되었다. 열처리와 전석회화 처리 후 SBF에 침적한 결과, $TiO_2$ rutile 피크의 상대적 강도는 크게 증가되었지만 HA의 석출은 저하되는 경향을 보였다. 결론: 이상의 결과로 미루어 볼 때, 양극산화 처리한 $TiO_2$ 나노튜브는 $600^{\circ}C$에서의 열처리에 의해 피막층이 안정화되고, 0.5 M $Na_2HPO_4$ 수용액 24시간 침적과 $Ca(OH)_2$ 포화수용액에 5시간 침적으로 표면에 인산칼슘층을 형성하는 것이 표면활성도를 개선하는데 유효함을 알 수 있었다.

다공질 실리콘 알코올 가스 센서의 C-V 응답 특성 (C-V Response Properties of Alcohol Vapor Sensors Based on Porous Silicon)

  • 김성진;이상훈;최복길;성만영
    • 한국전기전자재료학회논문지
    • /
    • 제17권6호
    • /
    • pp.592-597
    • /
    • 2004
  • Porous silicon(PS) has received much attention as a sensitive material of chemical sensors because of its large internal surface area. In this work, we fabricated gas-sensing devices based on the porous silicon layer which could be applicable to the measurement of blood alcohol content(BAC), and estimated their electrical properties. The structure of the sensor is similar to an MIS (metal-insulator-semiconductor) diode and consists of thin Au/oxidized PS/PS/p-Si/Al, where the p-Si substrate is etched anisotropically to reduce the thickness. We measured C-V curves from two types of the samples with the PS layer treated by the different anodization current density of 60 or 100 mA/cm$^2$, in order to compare the sensitivity. As a result, the magnitude and variation of capacitances from the devices with the PS formed under the current density of 100 mA/cm$^2$ were found to be more detectable due to the larger internal surface.

아노다이징 처리된 대형 유압장치의 내면에 대한 연마 조건의 최적화 (Optimization of Polishing Conditions for Anodized Inner Surfaces in Large Hydraulic Devices)

  • 최수현;조영태
    • 한국기계가공학회지
    • /
    • 제18권7호
    • /
    • pp.14-21
    • /
    • 2019
  • Large-diameter hydraulic devices such as the hydraulic reservoir in aircraft that serves to balance the hydraulic pressure in the various hydraulic devices in the cabin and to store hydraulic oil are operated by the internal piston systems. However, since this operates in an environment with high temperature and humidity, it may cause the inner surface to flake during its operation. Therefore, an anodizing surface treatment is applied to improve the corrosion resistance, abrasion resistance, and smooth operation. However, anodizing increases the surface roughness. Accordingly, the polishing process that improves the surface roughness after anodizing is important. However, the existing polishing process is performed manually, which results in an inefficient process. Therefore, in this study, we selected the optimum polishing conditions for effective polishing using the experimental design to improve the polishing process for the $Al_2O_3$ film that forms after anodization. Through experiments, we confirmed that the surface uniformity after polishing was superior as the feed rate was slower when the same polishing time had been applied.

Characterization of Anodized Al 1050 with Electrochemically Deposited Cu, Ni and Cu/Ni and Their Behavior in a Model Corrosive Medium

  • Girginov, Christian;Kozhukharov, Stephan;Tsanev, Alexander;Dishliev, Angel
    • Journal of Electrochemical Science and Technology
    • /
    • 제12권2호
    • /
    • pp.188-203
    • /
    • 2021
  • The specific benefits of the modified films formed on preliminary anodized aluminum, including the versatility of their potential applications impose the need for evaluation of the exploitation reliability of these films. In this aspect, the durability of Cu and Ni modified anodized aluminum oxide (AAO) films on the low-doped AA1050 alloy was assessed through extended exposure to a 3.5% NaCl model corrosive medium. The electrochemical measurements by means of electrochemical impedance spectroscopy (EIS) and potentiodynamic scanning (PDS) after 24 and 720 hours of exposure have revealed that the obtained films do not change their obvious barrier properties. In addition, supplemental analyses of the coatings were performed, in order to elucidate the impact of the AC-deposition of Cu and Ni inside the pores. The scanning electron microscopy (SEM) images have shown that the surface topology is not affected and resembles the typical surface of an etched metal. The subsequent energy dispersive X-ray spectroscopy (EDX) tests have revealed a predominance of Cu in the combined AAO-Cu/Ni layers, whereas additional X-ray photoelectron (XPS) analyses showed that both metals form oxides with different oxidation states due to alterations in the deposition conditions, promoted by the application of AC-polarization of the samples.

다공성 실리콘 산화막의 C-V 특성 (C-V Characteristics of Oxidized Porous Silicon)

  • 김석;최두진
    • 한국세라믹학회지
    • /
    • 제33권5호
    • /
    • pp.572-582
    • /
    • 1996
  • 전류밀도, 70mA/cm2와 전류인가시간, 5초, 10초 조건의 양극반응으로 다공성 실리콘을 제작하여 800~110$0^{\circ}C$에서 열산화시킨 후 AI 전극을 증착시켜 만든 MOS(Metal Oxide Semiconductor) 구조의 C-V(Capacilance-Voltage) 특성을 조사하였다. 800, 90$0^{\circ}C$의 저온과 20~30분 이내의 단시간 산화에서는 산화막의 유전상수가 보통의 열산화막보다 크게 나타나고, 산화온도가 110$0^{\circ}C$의 고온과 60분 이상의 장시간 산화의 경우에는 3.9에 근접한 값을 갖는다. 이는 다공성 실리콘 산화막내에 존재하는 산화되지 않은 silicon들에 의한 효과와 표면적 증가에 의한 정전용량의 증가 효과가 복합적으로 작용하는 것이 그 원인이라 생각된다.

  • PDF

양극산화처리를 통한 다공성 임플랜트 표면의 표면거칠기 증대에 대한 연구 (STUDY ON THE ENHANCING MICRO-ROUGHNESS OF POROUS SURFACED DENIAL IMPLANT THROUGH ANODIZATION)

  • 윤태호;송광엽
    • 대한치과보철학회지
    • /
    • 제44권5호
    • /
    • pp.617-627
    • /
    • 2006
  • Statement of problem: HA has been used as a coating material on Ti implants to improve osteoconductivity. However. it is difficult to form uniform HA coatings on implants with complex surface geometries using a plasma spraying technique. Purpose : To determine if Ti6Al4V sintered porous-surfaced implants coated with HA sol-gel coated and hydrothermal treated would accelerate osseointegration. Materials and Methods : Porous implants which were made by electric discharge were used in this study. Implants were anodized and hydrothermal treatment or HA sol-gel coating was performed. Hydrothermal treatment was conducted by high pressure steam at $300^{\circ}C$ for 2 hours using a autoclave. To make a HA sol, triethyl phosphite and calcium nitrate were diluted and dissolved in anhydrous ethanol and mixed. Then anodized implant were spin-coated with the prepared HA sols and heat treated. Samples were soaked in the Hanks solution with pH 7.4 at $37^{\circ}C$ for 6 weeks. The microstructure of the specimens was observed with a scanning electron microscope (SEM), and the composition of the surface layer was analyzed with an energy dispersive spectroscope (EDS). Results : The scanning electron micrographs of HA sol-gel coated and hydrothermal treated surface did not show any significant change in the size or shape of the pores. After immersion in Hanks' solution the precipitated HA crystals covered macro- and micro-pores The precipitated Ca and P increased in Hanks' solution that surface treatment caused increased activity. Conclusion : This study shows that sol-gel coated HA and hydrothermal treatment significantly enhance the rate of HA formation due to the altered surface chemistry.