• Title/Summary/Keyword: A Drain Noise

Search Result 81, Processing Time 0.028 seconds

A study on the noise criteria of water supply and drain installations in apartment bathroom (공동주택 욕실 급배수 설비소음 기준설정에 관한 연구)

  • Kim, Hang;Song, Guk-Gun;Lee, Tai-Gang;Ko, Kwang-Pil;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.484-487
    • /
    • 2007
  • This study was analyzed the correlation between physically measured values and psychological response for noise of water supply and drain installations in apartment bathroom. It exhibited the noise criteria of water supply and drain installations in apartment bathroom after recording noise of water supply and drain installations. Also, It was carried out the field psycho-acoustic test to find a correlation between physically measured values and psychological response of the noise criteria of water supply and drain installations in apartment bathroom, and the results is that 40dB (A) to 45dB (A) was investigated suitable in lowest criteria.

  • PDF

Gate-to-Drain Capacitance Dependent Model for Noise Performance Evaluation of InAlAs/InGaAs Double-gate HEMT

  • Bhattacharya, Monika;Jogi, Jyotika;Gupta, R.S.;Gupta, Mridula
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.4
    • /
    • pp.331-341
    • /
    • 2013
  • In the present work, the effect of the gate-to-drain capacitance ($C_{gd}$) on the noise performance of a symmetric tied-gate $In_{0.52}Al_{0.48}As/In_{0.53}Ga_{0.47}As$ double-gate HEMT is studied using an accurate charge control based approach. An analytical expression for the gate-to-drain capacitance is obtained. In terms of the intrinsic noise sources and the admittance parameters ($Y_{11}$ and $Y_{21}$ which are obtained incorporating the effect of $C_{gd}$), the various noise performance parameters including the Minimum noise figure and the Minimum Noise Temperature are evaluated. The inclusion of gate-to-drain capacitance is observed to cause significant reduction in the Minimum Noise figure and Minimum Noise Temperature especially at low values of drain voltage, thereby, predicting better noise performance for the device.

A Study on the Characteristics of Construction Noise by Sand Drain Method (Sand Drain 공법에 의한 작업시 발생하는 건설소음의 특성에 관한 연구)

  • Yun, Hae-Dong;Kim, Jae-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.500-505
    • /
    • 2000
  • Recently, with the increasing of construction works, large construction equipment are used to reduce the term of work and labor cost in construction field. Therefore, construction equipment noise has caused much annoyance for a number of dweller in nearby construction field and it has become a very serious problem in our living environment. Neverthless, in our country, adequite guidelines for the construction equipment noise are very deficiency because of the lack of basic data and insufficient research works. From this point of view, this study attempts to survey the characteristics of attenuation and propagation of Sand Drain Method in construction field. On the basis of measurement value, we analysed about prediction possibility of Sand Drain Method. This study also present a basic data found a effective plans for Sand Drain Method.

  • PDF

An experimental study on the rating of noise emission from water supply and drain installations in apartment bathroom (공동주택 욕실 급배수음 평가방법 제정방안에 관한 실험적 연구)

  • Lee, Tai-Gang;Song, Min-Jeong;Jang, Gil-Soo;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.5-10
    • /
    • 2006
  • This study aims to propose appropriate evaluating method of noise emission from water supply and drain installations in apartment bathroom. Because KS(Korean Standard) about water installations noise in apartment bathroom only are establishing the measurement procedure of it, Evaluation and rating procedure is necessary to improve the sound insulation performance of the apartment and to reduce the apartment dweller's unsatisfaction with the noise. Thus, this study reviewed the standards and evaluating methods about the water supply and drain installations noise of many other country. We measured the noise emission from the installations in many apartment bathroom, and then we calculated the noises to dB(A), N, NC evaluated numbers. We analyze the coefficient of the corelation among the evaluated numbers to induce the appropriate method. As a result, the dB(A) method is most easy to evaluateing and very high corelated wth N and N index, So the dB(A) method is suitable to be adopted KS evaluating procedure of noise emission from water installations in apartment bathroom.

  • PDF

An study on the Noise rating of water supply and drain installations in apartment bathroom (급배수 설비소음 평가방법 선정을 위한 실험적 연구)

  • Lee, Tai-Kang;Ko, Kwang-Pil;Choi, Eun-Seok;Kim, Hang;Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.7 no.1
    • /
    • pp.57-64
    • /
    • 2007
  • This study aims to propose appropriate evaluating method of noise emission from water supply and drain installations in apartment bathroom. The measurement procedure of water installations noise in apartment bathroom were established, so it is necessary to provide the evaluating method and criteria to improve the sound insulation performance of the apartment and to reduce the apartment dweller's unsatisfaction with the noise. Thus, this study reviewed the standards and evaluating methods about the water supply and drain installations noise of many other country. After measuring the noise emission from the installations in many apartment bathroom, The noise were evaluated dB(A), N, NC index, To induce the appropriate method, the coefficient of the correlation among the evaluated numbers were analyzed. As a result, the dB(A) method is most easy to evaluating and very high correlated with N and N index, So the dB(A) method is suitable to be adopted KS evaluating procedure of noise emission from water installations in apartment bathroom.

An Experimental Study on the Subjective Response for Water Supply and Drain Installations in Apartment Bathroom (공동주택 급배수 설비소음의 주관반응에 관한 실험적 연구)

  • Lee, Tai-Gang;Ko, Kwang-Pil;Kim, Hang;Song, Guk-Gon;Kim, Sun-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.6
    • /
    • pp.663-673
    • /
    • 2008
  • The purpose of this study is to analyze the appropriate evaluation method for the water supply and drain noise of bathroom in apartment and to propose some fundamental idea on its regulation. For this reason, it was studied the acoustical characteristics of water supply and drain noise as modifying the water supply pressure for the washbasins and toilet stools and suggested the optimum evaluation method through psychoacoustic test. As a result of investigation of the levels by evaluating the adjectives and noise sources with 7-step criteria corresponding to each level of plumbing noises and analysis of the correlation between physical evaluation values by comparing the criteria, dB(A), N, and NC, with subject's response, determination coefficient($R^2$) was shown to be relatively fair or higher ranged from 0.65 to 0.92. It is shown that 'Harsh', 'Nervous', 'Unpleasant', 'Distasteful', and 'Repellent' as a second factor are to be appropriate to evaluate plumbing noise. Above these results could be used in basic data establishing KS(Korean Standard) for evaluation and rating procedure and measures reducing these noise.

An Experimental Study on the Selection of the Proper Vocabularies for Evaluation about the Noise Emission from Water Supply and Drain Installations in Apartment Bathroom (공동주택 욕실 급배수 설비소음 평가를 위한 적정어휘 선정에 관한 실험적 연구)

  • Song, Guk-Gon;Kim, Hang;Lee, Tai-Kang;Ko, Kwang-Pil;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.679-682
    • /
    • 2007
  • This study aims to select the proper vocabularies for evaluation about the noise emission from water supply and drain installations in apartment bathroom. As a result of surveying overlapping vocabularies and scores of them for each sound sources, 'annoying', 'noisy', 'dynamic' and 'strident' are main unpleasant vocabularies to the noise from water supply and drain installations in apartment bathroom. And vocabularies such as 'dynamic', 'sudden', 'loudness', 'noisy' are classified into the first factor by analysis.

  • PDF

A Study on the Structure-borne Noise and Noise Reduction of Drainage Pipes (배수관의 구조소음과 소음저감에 관한 연구)

  • Ryu, B.J.;Lee, G.S.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.194-202
    • /
    • 2009
  • The paper deals with the countermeasure against structure-borne noise source and noise reduction of drainage pipes. Recently, the problem the problem of the toilet drain noise of an apartment house has been become the center of public interest and a target of public grievance. Generally, the drain noise of a toilet in the apartment house has a pink noise characteristics below 2 kHz level, and therefore, the structure-borne noise has a great effect on the entire drain noise. In order to measure the transmission loss for various kinds of pipes such as PVC pipes, cast-iron pipes and newly developed AS pipes, experimental setup containing speakers as a sound source was designed and manufactured. The second-stories measurement room with a small size anechoic chamber was constructed and the noise level for different kinds of drainage pipes was measured by the sound level meter. Through the experimental research in the study, noise reduction capacity for various kinds of drainage pipes and countermeasures against structure-borne noise source are demonstrated.

  • PDF

LNA Design Uses Active and Passive Biasing Circuit to Achieve Simultaneous Low Input VSWR and Low Noise (낮은 입력 정재파비와 잡음을 갖는 수동 및 능동 바이어스를 사용한 저잡음증폭기에 관한 연구)

  • Jeon, Joong-Sung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.8
    • /
    • pp.1263-1268
    • /
    • 2008
  • In this paper, the low noise power amplifier for GaAs FET ATF-10136 is designed and fabricated with active bias circuit and self bias circuit. To supply most suitable voltage and current, active bias circuit is designed. Active biasing offers the advantage that variations in the pinch-off voltage($V_p$) and saturated drain current($I_{DSS}$) will not necessitate a change in either the source or drain resistor value for a given bias condition. The active bias network automatically sets a gate-source voltage($V_{gs}$) for the desired drain voltage and drain current. Using resistive decoupling circuits, a signal at low frequency is dissipated by a resistor. This design method increases the stability of the LNA, suitable for input stage matching and gate source bias. The LNA is fabricated on FR-4 substrate with active and self bias circuit, and integrated in aluminum housing. As a results, the characteristics of the active and self bias circuit LNA implemented more than 13 dB and 14 dB in gain, lower than 1 dB and 1.1 dB in noise figure, 1.7 and 1.8 input VSWR at normalized frequency $1.4{\sim}1.6$, respectively.

DEVELOPMENT OF EFFICIENT METHODS TO REDUCE THE EMITTED NOISE LEVELS OF APPLIANCE DRAIN PUMPS

  • Ozturk, Cuneyt
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1994.06a
    • /
    • pp.716-721
    • /
    • 1994
  • The goal of this study is to develop treatment methods for improving the noise quality of Home Appliance Drain Pumps. Developed treatment methods covers the various methods including the control of the water level through the developed electronic circuity and the various modifications over the design of impeller and fan units. In the first part of the studies Dominant noise sources of the pumps are analyzed. Specific noise problems of the pumps are classified on the basis of mechanic and magnetic origins. Factors including the pressure variations at suction head, magnetic interactions with structure, specific fan noises are studied sequentially. The second part of the studies are considered for development and application of treatment methods. Results denoted the basic problems and ways to improve the noise quality by treating the dominant soureces of drain pumps.

  • PDF