• 제목/요약/키워드: 플랜트

검색결과 3,288건 처리시간 0.027초

골육착성 보철 치료시 임플랜트와 자연 지대치와의 연결 방법에 따른 관탄성 응력 분석 (PHOTOELASTIC ANALYSIS OF STRESS INDUCED BY FIXED PROSTHESES WITH RIGID OF NONRIGID CONNECTION BETWEEN NATURAL TOOTH AND OSSEOINTEGRATED IMPLANT)

  • 김영일;정재헌;조규종
    • 대한치과보철학회지
    • /
    • 제31권2호
    • /
    • pp.271-300
    • /
    • 1993
  • The purpose of this study was to analyze the stress distribution at supporting bone according to the types of connection modality between implant and tooth in the superstrcture. This investigation evaluated the stress patterns in a photoelastic model produced by three different types of dental implants such as Branemark, Steri-Oss, IMZ and resin tooth using the techniques of quasi three dimensional photoelasticity. The teeth-supported bridge had a first molar pontic supported by second premolar and second molar as a control group. The implant and toothsupported bridge had a first molar pontic supported by second premolar and implant posterior retainer as an experimental group. Prostheses were mechanically connected to an adjacent second premolar by the rigid of nonrigid connection, Nonrigid connection used an attachment placed between the tooth-supported and fixture-supported component. The female(keyway) of attachment was placed on the distal end of the retainer supported by the tooth ; the male(Key) of attachment connected to the osseointegrated bridge was engaged into the keyway. All prostheses were casted in the same nonprecious alloy and were cemented and screwed on their respective abutments and implants. 16㎏ of vertical loads on central fossae of second premolar, first molar pontic, implant of second molar were applied respectively and 6.5㎏ of inclined load on middle buccal surface of first molar pontic was applied. The results were as follows : 1. Under the vertical load on the central fossa of first mloar pontic, the stress developed at the apex of tooth of implat was more uniformly distributed in the case of nonrigid connection than in the case of rigid connection. 2. Under the vertical load on the central fossa of first molar pontic, the stress developed around the cervical area of tooth of implant was larger in the case of rigid connection than in the case of nonrigid connection because the bending moment was more occured in the case of rigid connection than in the case of nonrigid connection. 3. Stress was more restricted to the loaded side of nonrigid connection than to that of rigid connection 4. Under the inclined load. The set screw loosening of implant was more easily occured in the case of nonrigid connection than in the case of rigid connection due to torque moment. 5. In the case of Branemark implant, the stress concentration in second premolar was larger and the stress developed around the cervical area of implant was lower than any other cases under the vertical load, because Branemark implant with the flexible gold screw was showed in incline toward second premolar by a bending moment. 6. The stress developed around the apex of tooth or implant was more uniformly distributed in the case of Steri-Oss implant with stiff screw than in the case of Branemark implant under the vertical load. But, the stress developed around the cervical area of the Steri-Oss implant was larger than that of any other implants because bending moment was occured by vertical migration of second premolar. 7. The stress distribution in the case of IMZ implant was similar to the case of natural teeth under small vertical load. But, the residual stress around the implant was showed to occurdue to deformation of IMC and sinking of screw under larger vertical load.

  • PDF

폴리설폰 중공사막 모듈을 이용한 자동차 연료용 고순도 바이오메탄 분리공정 연구 (Membrane Process Using Polysulfone Hollow Fiber Membranes for Vehicle Fuel Production from Bio-Methane Mixture)

  • 김지상;공창인;박보령;김정훈
    • 멤브레인
    • /
    • 제24권3호
    • /
    • pp.213-222
    • /
    • 2014
  • 자동차 연료용 바이오가스의 고순도 메탄 분리정제를 위해 2단 재순환 분리막 공정을 연구하였다. 2단 재순환 분리막 공정을 개발하기 위해 폴리설폰(Polysulfone) 중공사 모듈을 채택하여 이산화탄소, 메탄의 순수투과도를 측정하였다. 또한 모델 혼합가스를 대상으로 모듈의 메탄농도와 압력에 대해 투과실험을 수행하여 메탄의 농도와 회수율에 대한 연구를 수행하였다. 그 결과를 토대로 2단 재순환 분리막 파일럿 플랜트를 제작하였으며 현장에서 발생되는 바이오가스를 대상으로 공정변수에 대한 메탄 회수율과 농도에 관한 투과실험을 수행하였다. 제습기와 탈황설비 등의 전처리설비를 거쳐 가스 내의 수분을 500 ppm 이하, 바이오가스내의 황화수소 농도를 20 ppm 이하로 제거하였으며 그 정제된 혼합가스를 대상으로 파일럿 분리막 공정의 막면적비에 따른 운전결과를 알아보기 위하여 1, 2단의 막면적비가 각각 1:1, 1:3, 2:2가 되도록 구성하여 실험을 진행한 결과, 1단의 막면적은 $1m^2$로 동일하고 2단의 면적비가 $1m^2$에서 $3m^2$로 증가하였을 경우 최종 공급유량은 6.6 L/min에서 80.7 L/min로 그리고 메탄 회수율은 메탄순도 95%에서 47.1%에서 92.5%로 증가하였다. 또한, 막 면적비가 1:1로 동일한 경우 전체 면적이 2배로 증가함에 따라서 유량은 6.6 L/min에서 100.8 L/min로 회수율은 47.1에서 88.3%를 나타내었다. 1:3 면적비에서 공급유량이 증가하는 경우, 최종 메탄 순도는 감소하고 메탄 회수율은 증가하는 것을 알 수 있었다. 운전압력이 증가할수록 공급유량은 증가하고 회수율은 다소 감소하는 것으로 나타났다. 실험을 통해 유효막면적, 공급압력과 공급유량의 변화가 공정 성능향상에 중요한 영향을 미친다는 것을 확인하였다.

해양심층수 에너지자원 이용 타당성 분석 연구 (A Feasibility Study on Thermal Energy Resource in Deep Ocean Water)

  • 김정협;김광태;박세헌;오위영;김현주
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제15권1호
    • /
    • pp.9-18
    • /
    • 2012
  • 우리나라의 연간 전력 소비량은 세계적으로 상위권에 속해 있으며, 전력을 생산하는 방법으로는 화력발전의 비중이 높아 $CO_2$의 배출량도 세계 10위이다. 이에 정부는 온실가스 감축을 위해 신재생에너지 기술 확보 및 실용화에 주안을 두고 있으며, 에너지 공급의 탈 화석화를 실현하기 위한 국가에너지기본계획을 수립하고 추진 중이다. 신재생 에너지의 하나인 해양심층수 열에너지의 자원화 기술은 저탄소 녹색성장을 위한 해양자원의 다각적 이용을 위한 핵심기술로서 자원 확보와 환경개선을 위해 국내 외에서 새롭게 주목을 받고 있다. 해양심층수 에너지의 해양온도차 발전과 냉난방 이용을 대상으로 다음과 같이 연구개발의 경제성 타당성을 분석하였다. 첫째, 1MW급 온도차발전 플랜트에서 해양심층수 및 발전소 온배수를 이용하여 전기를 생산할 경우 경제성은 미흡하나 연구개발을 통해 상용화 규모로 개발하면 전기의 생산 뿐 아니라 식수 및 탄소배출권 등을 고려할 때 경제성이 커질 수 있을 것으로 판단된다. 둘째, 1,000RT급을 대상으로 해양심층수의 냉난방 이용은 경제성은 양호한편이며 특히 탄소배출권을 고려한다면 충분한 경제성을 확보 가능하다. 이를 해양온도차 발전, 담수화, 농수산 이용 등과 연계하여 이용하면 경제적 파급효과가 커질 것으로 판단되어, 조기 실용화 및 보급 확산을 위한 연구개발이 필요하다.

고농도 질소폐수로부터 암모니아 회수를 위한 다단수직형 암모니아스트리핑조 개발(I) (Development of a Vertical Multi-stage Ammonia Stripping Reactor for Recovering Ammonia from wastewater with High Nitrogen Concentrations(I))

  • 이재명;최홍복
    • 유기물자원화
    • /
    • 제25권2호
    • /
    • pp.41-48
    • /
    • 2017
  • 기존 혐기성 및 호기성 처리에서 우수성이 입증된 E-PFR을 적용한 다단수직형 암모니아 스트리핑조를 개발하고 랩스케일 실험을 수행하였다. 다단수직형 암모니아스트리핑조의 단수별 암모니아성 질소 제거 실험(pH 10, 온도 $35^{\circ}C$, 기액비 $3min^{-1}$의 동일 조건)에서 8시간 경과 후 단이 없는 반응기는 약 52.5%의 제거율을 나타났으며, 5단 반응기에서는 약 62.6%의 제거율이 나타나 약 10%의 효율 차이가 있는 것으로 확인하였다. pH 변화에 따른 암모니아성 질소 제거 실험 (5단 반응기, 온도 $35^{\circ}C$, 기액비 $3min^{-1}$의 동일 조건)에서 8시간 경과 후 pH 9는 약 42.6%의 제거율을 나타났으며, pH 11에서 약 74.4%의 제거율이 나타났다. 온도 변화에 따른 암모니아성 질소 제거 실험 (5단 반응기, pH 10, 기액비 $3min^{-1}$의 동일 조건)에서 8시간 경과 후 $25^{\circ}C$에서 약 51%의 제거율을 나타났으며, $45^{\circ}C$에서 약 87.2%의 제거율이 나타났다. 공기주입량 변화에 따른 암모니아성 질소 제거 실험 (5단 반응기, pH 10, 온도 $35^{\circ}C$의 동일 조건)에서 8시간 경과 후 기액비 $2min^{-1}$에서 약 45.8%의 제거율을 나타났으며, 기액비 $4min^{-1}$에서 약 75%의 제거율이 나타났다. 이러한 결과를 바탕으로 추후 연속 운전 평가를 통해 실증플랜트 설계를 위한 인자 도출에 활용하고자 한다.

친환경에너지타운에서 보어홀지중열 저장(BTES) 활용 융복합 열에너지 공급 시스템 사례 연구 (International Case Studies on the Eco-friendly Energy Towns with Hybrid Thermal Energy Supply System and Borehole Thermal Energy Storage (BTES))

  • 심병완
    • 자원환경지질
    • /
    • 제51권1호
    • /
    • pp.67-76
    • /
    • 2018
  • 본 연구는 해외 친환경에너지타운에서 보어홀 지중열 저장(BTES) 기술을 활용한 융복합 열에너지 공급 시스템의 3가지 사례로서 캐나다의 ADEU(Alexandra District Energy Utility) 및 DLSC(Drake Landing Solar Community)와 덴마크의 Brædstrup Solpark를 조사하였다. 이들 지역 냉난방 시스템들은 효율과 지속가능성을 높이기 위하여 다중 에너지원을 활용하고 있다. ADEU는 리치몬드시에서 726 개의 지중열교환기로 이루어진 지열필드 및 천연 가스 백업 보일러를 이용한 대규모 지역에너지 공급을 위해 개발되었다. 그리고 캘거리시 인근 Okotoks에 위치한 DLSC는 여름철에 풍부한 태양열 에너지를 144 개의 지중열교환기를 통하여 지중에 저장하고 겨울철 난방을 위해 각 주택에 열에너지를 분배하는 계간축열 방식의 지역난방 시스템이다. Brædstrup Solpark 지역난방 시스템은 태양열, 히트 펌프, 보일러 플랜트 및 계간축열을 위한 48 개의 지중열교환기로 구성되며 다중 에너지원을 이용하여 열을 저장한다. BTES 시추공의 심도와 축열량은 지하수 유동과 지반의 열물성에 따라 영향을 많이 받는다. 이러한 시스템들은 경쟁력 있는 에너지 가격으로 장기적인 에너지를 공급함으로서 신뢰성과 경제성을 평가 받았다. 그리고 ADEU와 Brædstrup Solpark는 서비스 영역 확장을 위한 장기 에너지 공급 계획을 기반으로 확장이 진행중이다. 본 조사를 통하여 이러한 시스템들은 사회 경제적인 이익 뿐만아니라 환경적인 관점이 설계에 반영되어 있는 것을 알 수 있었다. 국내에서도 이러한 프로젝트를 실시하기 위해서는 지방 정부 또는 관련 기관의 에너지 정책 지원 뿐만아니라, 관리 기관 설치를 통한 장기적인 협력이 필요하다.

음식물류폐기물 수소 발효액의 유변학적 특성과 교반강도 고찰 (Rheological Characteristics of Hydrogen Fermented Food Waste and Review on the Agitation Intensity)

  • 김민균;이모권;임성원;신상룡;김동훈
    • 유기물자원화
    • /
    • 제25권4호
    • /
    • pp.41-50
    • /
    • 2017
  • 점도, 임펠러 종류, 소비전력 등에 의해 영향을 받는 생물학적 폐기물 처리시설 및 에너지 생산 플랜트에서 적절한 교반 시스템의 설계는 필수적이다. 본 연구에서는 적절한 교반 시스템의 설계를 위해 음식물류폐기물을 이용하여 다양한 조건(운전 pH 및 농도)에서의 수소발효 시 유변학적 특성의 변화를 조사한 후, 이를 기반으로 교반강도를 설계하였다. 운전 pH에 따른 수소발효 실험에서 수소전환율은 $0.51{\sim}1.77mol\;H_2/mol\;hexose_{added}$였고, 가장 높은 수소전환율은 운전 pH 5.5에서 나타났다. 발효액은 전단속도가 증가함에 따라 점도가 감소하는 Shear thinning 거동을 보였다. 탄수화물이 분해되면서 발효 이후 점도는 초기 점도보다 감소하는 경향을 보였으나, 운전 pH의 변화에 따른 발효액의 점도 변화는 크지 않았다. 탄수화물 농도 10~50 g Carbo. COD/L에서 수소전환율은 $1.40{\sim}1.86mol\;H_2/mol\;hexose_{added}$로 운전 pH 조건이 수소전환율에 미친 영향과 비교했을 때 큰 차이는 없었다. 발효액의 Zero viscosity와 Infinite viscosity는 탄수화물 농도에 따라 각각 $10.4{\sim}346.2mPa{\cdot}s$$1.7{\sim}5.3mPa{\cdot}s$로 나타났는데, 10 g Carbo. COD/L와 20 g Carbo. COD/L에서 발효액의 점도 값은 거의 차이가 없었다. 실험 결과에 기초하여 교반강도를 설계한 결과, 기질농도 30 g Carbo. COD/L의 수소발효 초기 및 발효 후 교반강도는 각각 26.0, 10.0 rpm으로 약 2.5배 정도의 교반강도를 줄임으로써 에너지를 절약할 수 있을 것으로 사료된다.

타이타늄 임플랜트 시편 내부에 설치한 자석의 자성강도에 따른 골형성 변화 (THE CHANGE OF BONE FORMATION ACCORDING TO MAGNETIC INTENSITY OF MAGNET PLACID INTO TITANIUM IMPLANT SPECIMENS)

  • 황윤태;이성복;최대균;최부병
    • 대한치과보철학회지
    • /
    • 제43권2호
    • /
    • pp.232-247
    • /
    • 2005
  • Purpose. The purposes of this investigation were to discover the possibility of clinical application in the areas of dental implants and bone grafts by investigating the bone formation histologically around specimen which was depending on the intensity of magnetic field of neodymium magnet inside of the specimens. Material and method. 1. Measurement of magnetic intensity - placed the magnet inside of the specimen, and measured the intensity of magnetic field around the 1st thread and 3rd thread of specimen 20 times by using a Gaussmeter(Kanetec Co., Japan). 2. Surgical Procedure - Male rabbit was anesthetised by constant amount of Ketamine (0.25ml/kg) and Rompun (0.25ml/kg). After incising the flat part of tibia, and planted the specimens of titanium implant, control group was stitched without magnet, while experimental groups were placed a magnedisc 500(Aichi Steel Co., Japan) or magnedisc 800(Aichi Steel Co., Japan) into it, fixed by pattern resin and stitched. 3. Management after the surgery - In order to prevent it from the infection of bacteria and for antiinflammation, Gentamycin and Ketopro were injected during 1 week from operation day, and dressed with potadine. 4. Preparation of histomorphometric analysis - At 2, 4 and 8 weeks after the surgery, the animals were sacrificed by excessed Ketamine, and then, specimens were obtained including the operated part and some parts of tibia, and fixed it to 10% of PBS buffer solution. After embedding specimens in Technovit 1200 and B.P solution, made a H-E stain. Samples width was 75$\mu$m . In histological findings through the optical microscope and using Kappa image base program(Olympus Co. Japan), the bone contact ratio and bone area ratio of each parts of specimens were measured and analyzed. 5. Statistical analysis - Statistical analysis was accomplished with Mann Whitney U-test. Results and conclusion. 1. In histomorphometric findings, increased new bone formation was shown in both control & experimental groups through the experiment performed for 2, 4 & 8 weeks. After 4 weeks, more osteoblasts and osteoclasts with significant bone remodeling were shown in experimental groups. 2. In histomorphometric analysis, the bone contact ratios were 38.5% for experimental group 1, 29.5% for experimental group 2 and 11.9% for control group. Experimental groups were higher than control group(p<0.05) (Fig. 6, Table IV). The bone area ratios were 60.9% for experimental group 2, 46.4% for experimental group 1 and 36.0% for control group. There was no significantly statistical difference between experimental groups and control group(p<0.05) (Fig. 8, Table VII) 3. In comparision of the bone contact ratios at each measurement sites according to magnetic intensity, experimental group 2(5.6mT) was higher than control group at the 1st thread (p<0.05) and experimental group 1 (1.8mT) was higher than control group at the 3rd thread(p<0.05) (Fig. 7, Table V, VI). 4. In comparision of the bone area ratios at each measurement sites according to magnetic intensity, experimental group 2(5.6mT) was higher than control group and experimental group 1 (4.0mT) at the 1st thread(p<0.1) and experimental group 2(4.4mT) was higher than experimental group 1 (1.8mT) at the 3rd thread(p<0.1) (Fig. 9, Table IX, X). Experiment group 2 was largest, followed by experiment group l and control group at the 3rd thread of implant. There was a significant difference at the 1st thread of control group & experiment group 2, and at 1st thread & 3rd thread of experiment group 1 & 2, and not at control group experiment group 1.(p<0.1)

공진 주파수 분석법에 의한 임플랜트의 안정성 측정에 관한 연구 (A STUDY ON THE MEASUREMENT OF THE IMPLANT STABILITY USING RESONANCE FREQUENCY ANALYSIS)

  • 박철;임주환;조인호;임헌송
    • 대한치과보철학회지
    • /
    • 제41권2호
    • /
    • pp.182-206
    • /
    • 2003
  • Statement of problem : Successful osseointegration of endosseous threaded implants is dependent on many factors. These may include the surface characteristics and gross geometry of implants, the quality and quantity of bone where implants are placed, and the magnitude and direction of stress in functional occlusion. Therefore clinical quantitative measurement of primary stability at placement and functional state of implant may play a role in prediction of possible clinical symptoms and the renovation of implant geometry, types and surface characteristic according to each patients conditions. Ultimately, it may increase success rate of implants. Purpose : Many available non-invasive techniques used for the clinical measurement of implant stability and osseointegration include percussion, radiography, the $Periotest^{(R)}$, Dental Fine $Tester^{(R)}$ and so on. There is, however, relatively little research undertaken to standardize quantitative measurement of stability of implant and osseointegration due to the various clinical applications performed by each individual operator. Therefore, in order to develop non-invasive experimental method to measure stability of implant quantitatively, the resonance frequency analyzer to measure the natural frequency of specific substance was developed in the procedure of this study. Material & method : To test the stability of the resonance frequency analyzer developed in this study, following methods and materials were used : 1) In-vitro study: the implant was placed in both epoxy resin of which physical properties are similar to the bone stiffness of human and fresh cow rib bone specimen. Then the resonance frequency values of them were measured and analyzed. In an attempt to test the reliability of the data gathered with the resonance frequency analyzer, comparative analysis with the data from the Periotest was conducted. 2) In-vivo study: the implants were inserted into the tibiae of 10 New Zealand rabbits and the resonance frequency value of them with connected abutments at healing time are measured immediately after insertion and gauged every 4 weeks for 16 weeks. Results : Results from these studies were such as follows : The same length implants placed in Hot Melt showed the repetitive resonance frequency values. As the length of abutment increased, the resonance frequency value changed significantly (p<0.01). As the thickness of transducer increased in order of 0.5, 1.0 and 2.0 mm, the resonance frequency value significantly increased (p<0.05). The implants placed in PL-2 and epoxy resin with different exposure degree resulted in the increase of resonance frequency value as the exposure degree of implants and the length of abutment decreased. In comparative experiment based on physical properties, as the thickness of transducer increased, the resonance frequency value increased significantly(p<0.01). As the stiffness of substances where implants were placed increased, and the effective length of implants decreased, the resonance frequencies value increased significantly (p<0.05). In the experiment with cow rib bone specimen, the increase of the length of abutment resulted in significant difference between the results from resonance frequency analyzer and the $Periotest^{(R)}$. There was no difference with significant meaning in the comparison based on the direction of measurement between the resonance frequency value and the $Periotest^{(R)}$ value (p<0.05). In-vivo experiment resulted in repetitive patternes of resonance frequency. As the time elapsed, the resonance frequency value increased significantly with the exception of 4th and 8th week (p<0.05). Conclusion : The development of resonance frequency analyzer is an attempt to standardize the quantitative measurement of stability of implant and osseointegration and compensate for the reliability of data from other non-invasive measuring devices It is considered that further research is needed to improve the efficiency of clinical application of resonance frequency analyzer. In addition, further investigation is warranted on the standardized quantitative analysis of the stability of implant.

해외 LNG벙커링 비즈니스 모델 분석 (Analysis of Overseas LNG Bunkering Business Model)

  • 김기동;박소진;최경식;조병학;오영삼;조상훈;차건종;조원준;성홍근
    • 한국가스학회지
    • /
    • 제22권1호
    • /
    • pp.37-44
    • /
    • 2018
  • 국제해사기구의 선박배출가스 규제 등의 환경규제 강화로 세계 주요 국가에서는 선박배출가스에 대한 3가지 솔루션 중에서 LNG연료를 장기적 솔루션으로 추진하는 국가와 기업이 늘어나고 있다. 본 연구에서는 세계적으로 LNG벙커링에 대한 비즈니스를 어떠한 형태로 이끌어 가는지에 대한 고찰로서, 주요 국가인 일본, 중국, 싱가포르의 아시아 지역과 유럽 그리고 미국을 중심으로 비즈니스 모델 관점에서 분석을 하였다. 연구결과 중국은 국가 위주의 LNG벙커링 정책 수립 후에 국가와 에너지 회사가 제휴하여 LNG연료추진선박용 LNG벙커링 비즈니스를 진행하여 있음을 발견하였다. 유럽 일부와 미국은 순수한 민간회사 위주의 LNG벙커링 비즈니스가 진행되고 있으며, 민간회사는 현재 선박유보다 저렴한 LNG연료 확보를 위하여 LNG터미널, 천연가스 액화플랜트 등의 중상류 사업자와의 제휴를 통해 가격 경쟁력이 높은 LNG를 확보하면서 자사 LNG연료추진선박에 LNG벙커링을 하는 비즈니스 모델을 가지고 있다. 전 세계 LNG벙커링 비즈니스는 공기업보다는 민간기업 위주로 진행되고 있으며, LNG벙커링 인프라 구축에는 초기비용이 필요하여 대부분 에너지 대기업 위주로 비즈니스가 진행되고 있었다. LNG벙커링 비즈니스는 현재 3가지 모델(TOTE 모델, Shell 모델, ENGIE 모델)이 개발 되고 있다. 국가별로 LNG벙커링 비즈니스 추진 방식은 기업 및 국가 정책에 따라 다르게 적용된다는 것을 발견하였다.

공정 시뮬레이션을 이용한 조사유기응력부식균열 시험 작업자 피폭량의 전산 해석에 관한 연구 (Numerical Calculations of IASCC Test Worker Exposure using Process Simulations)

  • 장규호;김해웅;김창규;박광수;곽대인
    • 한국방사선학회논문지
    • /
    • 제15권6호
    • /
    • pp.803-811
    • /
    • 2021
  • 본 연구에서는 공정 시뮬레이션 기술을 적용하여 조사유기응력부식균열 시험 작업자의 피폭량 평가를 하였다. 상용 공정 시뮬레이션 코드인 DELMIA Version 5를 사용하여 조사유기응력부식균열 분석 시험 설비, 핫셀 및 작업자를 작성하고 조사유기응력부식균열 시험 공정을 구현하였으며, 사용자 코딩을 통해 선량이 분포된 공간을 지나는 작업자의 누적 피폭량을 평가할 수 있도록 하였다. 작업자 모사를 위해 시험 공정별로 인체의 근골격계를 모방하여 약 200 개 이상의 자유도를 가지는 휴먼 마니킨 자세를 작성하였다. 작업자 피폭량 계산을 위하여 휴먼 마니킨 작업의 하위정보에 접근하여 자세 별 좌표, 시작 시간 및 유지 시간을 추출하였으며, 공간 선량 값과 자세 유지 시간을 곱하여 누적 피폭량을 계산하였다. 피폭량 평가를 위한 공간 선량은 MCNP6 Version 1.0을 사용하여 핫셀 내·외부 공간 선량을 계산하였으며, 계산된 공간 선량은 공정 시뮬레이션 도메인에 입력하였다. 공정 시뮬레이션을 이용한 피폭량 평가 결과와 전형적인 피폭량 평가 결과를 비교 분석한 결과, 상시 출입구역 내 일상 시험 작업에 대한 연간 피폭량은 각각 0.388 mSv/year 및 1.334 mSv/year로서 공정 시뮬레이션을 이용한 피폭량 평가 결과가 전형적인 방법의 피폭량 평가 결과 대비 70 % 낮게 예측되었다. 공간 선량 높은 구역에서 수행되는 특수작업에 대해서도 공정 시뮬레이션을 이용한 피폭량 평가를 수행하였으며, 피폭량이 높은 작업을 쉽게 선별할 수 있었고, 해당 작업의 휴먼 마니킨 자세와 공간 선량 가시화를 통해 직관적으로 작업 개선안을 도출할 수 있었다.