A STUDY ON THE MEASUREMENT OF THE IMPLANT STABILITY USING RESONANCE FREQUENCY ANALYSIS |
Park Cheol
(Department of Prosthodontics, College of Dentistry, Dankook University)
Lim Ju-Hwan (Department of Prosthodontics, College of Dentistry, Dankook University) Cho In-Ho (Department of Prosthodontics, College of Dentistry, Dankook University) Lim Heon-Song (Department of Prosthodontics, College of Dentistry, Dankook University) |
1 | Albrektsson T, Jacobsson M. Bonemetal interface in osseoi- ntegration. J Prosthet Dent 1987;57:597 DOI ScienceOn |
2 | Meredith N, Rasmussen L, Sennerby L. Alleyne D. Mapping implant stability by resonance frequency analysis. Med Sci. Research 1996;24:191 |
3 | Measurement of Vibration & Frequency 30 analysis International Industiral Information system. 1989 |
4 | Singiresu S R. Determination of natural frequency & mode shape. Mechanical vibration 1986:322 |
5 | Cawley P, Adams RD. The mechanics of the coin-tap method of non-destructive testing. J Sound Vibration 1988:122(2):299 |
6 | Johansson CB, Strid KG. Assessment of bone quality from cutting resistance during implant surgery. Int J Oral Maxillofac Implants 1994:9:279 |
7 | Brunski JB. Biomaterials and biomechanics in dental implant design. Int Oral Maxillofac Implants 1988:3:85 |
8 | Brunski JB, Mocclia Jr AF, Pollack SR. The influence of functional use of endosseous dental implants on the tissue-implant interface. I Histological aspects. J Dent Res 1979;10:58 |
9 | Carr AB, Larsen PE, Papazoglou E, McGlumphy. Reverse torque failure of screw-shaped implants in babbons : Baseline data for abutment torque application. Int J Oral Maxillofac Implants 1995;10:167 |
10 | Sennerby L. Thomsen P. Ericson LE. Early tissue response to titanium implants inserted in rabbit cortical bone. Part 2 Ultrastructural observations. J Mater Sci. : Mater in Med 1993;4:494 DOI |
11 | Wennerberg A. On surface roughness and implant incorporation. Ph.D. Thesis. Department of Biomaterials/Handicap Research, Institute for Surgical Sciences, and Department of Prosthetic Dentistry. Gothenburg Universith, Gothenburg, Sweden. 1996 |
12 | Rice JC, Cowin SC, Bowman JA. On the dependence of the elasticity and strength and of cancellous bone on apparent density. J Biomech 1988;21:155 DOI ScienceOn |
13 | Branemark PI. Osseointegration and its experimental background. J Prosthet Dent 1983;50:399 DOI ScienceOn |
14 | Bruel and Kjaer : Model Analysis 1992 |
15 | Friberg B, Sennerby L, Roos J, Strid CG, Lekholm U. Evaluation of bone density using cutting resistance measurements and microradiography : an in vitro study in pig ribs. Clin Oral Impl Res 1995(b):6:164 |
16 | Chavez H, Lance FO. Assessment of oral implant mobility. J Prosthet Dent 1994;70:421 |
17 | Handbook of Noise & Vibration : The Korean Society for Noise & Vibration Engineers. 1995;221 |
18 | Meredith N, Alleyne D, Cawley P. Quantitative determination of the stability of the implant-tissue interface using resonance frequecny analysis : Clin Oral Impl Res 1996:7:261 |
19 | Albrektsson T, Zarb GA, Worthington P, Eriksson AR. The long term efficacy of currently used dental implants : A review and proposed criteria of success. Int J Oral Maxillofac Implants 1986;1:11 |
20 | van Steenberghe D, Tricio J, Nys A. Damping characteristics of bone to implant interfaces. Clin Oral Impl Res 1995;6:31 DOI ScienceOn |
21 | Albrektsson T. Bone tissue response. In Osseointegration in clinical dentistry. Quintessence Co. Chicago 1985;129 |
22 | Tsuboi Y, Sennerby L, Mori K, Matsuhisa H. The dynamic of the osseointegrated implant. Part 1: Theoretical analysis of the osseointegrated implant and the natural tooth by the vibration theory. Personal Communication. 1996 |
23 | Meredith N, Book K, Friberg B, Jemt T, Sennerby L. Resonance frequency measurements of implant stability in vivo. Clin Oral Implant Research 1997:226 |
24 | Derhami K, Wolfaardt JF. Dent M, Faulkner G. Grace M. Assessment of the periotest device in base line mobility measurements of craniofacial implants. Int J oral Maxillofac Implants 1995;10:221 |
25 | Ashman RB. Ultrasonic determination of the elastic properties of cortical bone : techniques and limitations 'Thesis'. New Orleans, LA : Tulane University, 1982 |
26 | Brunski JB, Mocclia Jr AF, Pollack SR, Korostoff E, Trachtenberg D. Investigation of surfaces of retrieved endosseous dental implants of commercially pure titanium. American Society for Testing and Materials. 1983;189 |
27 | Hobo S, Ichida E, Garcia LT. Osseointegration and occlusal rehabilitation. Chicago. Quintessence Publ Co. 1989;265 |
28 | Lekholm U, Zarb GA. Patient selection and preparation. In Osseointegration in clinical dentistry (Branemark PI, Zarb G, Albrektsson T, eds). Quintessence Co. Chicago. 1985;199 |
29 | Albrektsson T, Sennerby L. State of the art in oral implants. J Clin Periodontol 1991;18:474 DOI |
30 | Shulte W. A new field of application of the Periotest mathod. The occlusal-periodontal load can now be measured quantitatively. Zahnarztl Mitt. 1988:78:474 |
31 | Johansson CB, Albrektsson T. A removal torque and histomorphometric study of commercial pure nobium and titanium implants in rabbit bone. Clin Oral Impl Res 1991;2:24 DOI ScienceOn |
32 | Elias JJ. Brunski JB, Scarton HA. A dynamic modal testing technique for non-invasive assessment of bone-dental implant interface. Int J Oral Maxillofac Implants 1996:11:728 |
33 | Branemark PI, Zarb GA, Albrektsson T. Tissue integrated prosthesis : Osseointegration in clinical dentistry, Chicago, Quintenssence Co, 1985;117 |
34 | Meredith N. On the clinical measurement of implant stability and osseointegration. Ph.D. Thesis, Department of Biomaterials / Handicap Research, Institude for Surgical Sciences. Gothenburg University, Gothenburg. Sweden. 1997 |
35 | Johansson CB, Sennerby L, Albrektsson T. A removal torque and histomorphometric study of bone tissue reactions to commercially pure titanium and vitallium implants. J Oral Maxillofac Implants B 1991;437 |
36 | Chavez H, Lance FO. Assessment of oral implant mobility. J Prosthet Dent 70 1994;421 |
37 | Cucchario PJ, DeLuzio A, Dario LJ, Cucchario SJ. Structural analyser in particular for medical implants. United States Patent No. 1996;5:518 |
38 | Friberg B. Bone quality evaluation during implant placement. MDS dissertation, University of Gothenburg, Gothenburg, Sweden, 1994 |
39 | Shulte W. The Periotest periodeontal status. Zahnarztl Mitt. 1986:76:1 |
40 | Tricio J, van Steenberghe D, Rosenberg D, Duchateau L. Implant stability related to insertion torque force and bone density: An in vitro study. J Prosthet Dent 1995;74:608 DOI ScienceOn |
41 | Branemark PI. A biomechanical study of osseointegration. Ph.D thesis. Department of Orthopaedics. Institute of Surgical Science and Institute of Anatomy and Cell Biology, University of Gothenburg, Gothenburg, 1996 |
42 | Johanson CB, Albrektsson T. Integration of screw implants in the rabbits : A 1-yrfollow-up of removal torque of titanium implants. Int J Oral Maxillofac Implants 1987;2:69 |
43 | Roos J, Sennerby L, Albrektsson T. An update on the clinical documentation on currently used bone anchored endosseous oral implants. Dent Update in press 1997 |
44 | Friberg B, Sennerby L, Roos J, Lekholm U. Identification of bone quality in conjunction with insertion of titanium implants. Clinical Oral Implant Research 1995(a);13:213 |
45 | Lim JH, Cho IH : A study on the evaluation of Bone quality of Maxillo and Mandibule by using peroitest. 1994;32:7.520 |
46 | Branemark PI. Hansson BO. Osseointegrated implants in the treatment of the edentulous jaw. Distributed by the Almquist and Wiksell periodical Co |
47 | Theories Practices of Vibration Samsung Institute of Technology of Electon particle. 1991:1 |
48 | Albrektsson T, Branemark PI, Hansson HA, Lindstrom J. Osseointegrated titanium implants. Acta Orthop Scand 1981;52:155 |
49 | Strid JG. Radiographic results. In osseointegration in clinical dentistry (Branemark PI, Zarb G, Albrektsson T. eds) Quintessence Publiahers, Chicago. 1985;187 |
50 | Sennerby L., Thomsen P, Ericson LE. Early tissue response to titanium implants inserted in rabbit cortical bone. Part 1 Light microscopic observations. J Mater Sci. : Mater in Med 1993;4:240 DOI |
51 | Deutch JE, Brunski JB. Numerical analysis of load distribution among dental implants. AADR Meeting, San Francisco, Calif. 1989:Paper No. 587 |