• Title/Summary/Keyword: 전열해

Search Result 947, Processing Time 0.029 seconds

Development of Remote Reld Testing Technique for Moisture Separator & Reheater Tubes in Nuclear Power Plants (원자력발전소 습분분리재열기 튜브 원격장검사 기술 개발)

  • Nam, Min-Woo;Lee, Hee-Jong;Kim, Cheol-Gi
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.4
    • /
    • pp.339-345
    • /
    • 2008
  • The heat exchanger tube in nuclear power plants is mainly fabricated from nonferromagnetic material such as a copper, titanium, and inconel alloy, but the moisture separator & reheater tube in the turbine system is fabricated from ferromagnetic material such as a carbon steel or ferrite stainless steel which has a good mechanical properties in harsh environments of high pressure and temperature. Especially, the moisture separator & reheater tubes, which use steam as a heat transfer media, typically employ a tubing with integral fins to furnish higher heat transfer rates. The ferromagnetic tube typically shows superior properties in high pressure and temperature environments than a nonferromagnetic material, but can make a trouble during the normal operation of power plants because the ferrous tube has service-induced damage forms including a steam cutting, erosion, mechanical wear, stress corrosion cracking, etc. Therefore, nondestructive examination is periodically performed to evaluate the tube integrity. Now, the remote field testing(RFT) technique is one of the solution for examination of ferromagnetic tube because the conventional eddy current technique typically can not be applied to ferromagnetic tube such as a ferrite stainless steel due to the high electrical permeability of ferrous tube. In this study, we have designed RFT probes, calibration standards, artificial flaw specimen, and probe pusher-puller necessary for field application, and have successfully carry out RFT examination of the moisture separator & reheater tube of nuclear power plants.

The Optimization of Thermal Conditions and Evaluation of Storage for Heated Chunbok-jang (전복장의 열처리 공정의 최적화 및 저장성 평가에 관한 연구)

  • Moon, Chang-Yong;Baek, Moo-Yeul;Kim, Hae-Kyung;Hahm, Young-Tae;Kim, Byung-Yong
    • Food Engineering Progress
    • /
    • v.15 no.3
    • /
    • pp.230-234
    • /
    • 2011
  • The objective of this study was to optimize the thermal condition and determine the shelf life of heated Chunbokjang product. The optimum thermal condition of heated Chunbok-jang product was determined by sensory test, and heat penetration curve was obtained by Thermal Microprocessor. Sterilization time was a 21~23 min until $F_0$ value reached 9 min, depending upon the number of abalone. As solid content was reduced and temperature of sterilization was increased, the thermal death time was decreased. The score of sensory test indicated that there was no significant difference in flavor of heated Chunbok-jang product made at different sterilization temperatures (110, 121.1, 125, and $130^{\circ}C$). Heated Chunbok-jang product, however, sterilized at $125^{\circ}C$ showed the highest score in texture and taste values. Salinity and pH were not changed during seven month storages, but texture became firmer, and any microorganism had not been detected from the heated chunbok-jang product during these periods. As a result of storage experiment, the shelf-life of heated Chunbok-jang product was 3-month at room temperature.

A Research of the Width of Passage in the Elementary School Classroom - Centered on Elementary Schools in Northen Gyeonggi Province - (초등학교 일반교실의 통로폭에 관한 조사 연구 - 경기 북부지역 초등학교를 중심으로 -)

  • Yoon, Hee-Cheol
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.17 no.3
    • /
    • pp.26-34
    • /
    • 2018
  • This research is a pre-research to find out profit module of 20 students in a classroom. I researched the widths of passages in the 30 classrooms of 5 elementary schools in Nothern Kyeonggi-do. I found the conclusions as follows. 1st, the area of 1 student's unit is $650(W){\times}950(D)$ 2nd, most of classrooms' students table placements are one-way types(77%). U-types are 13%. group study-types are 7% 3rd, The width between blackboard and front student's table is 2.08m. The width of passage between back seat and backboard is 1.12m. The width of passage between side wall and near student's table is 0.89m. The width of passage between window and near student's table is 0.74m. The width of vertical passage(A) between student's tables is 0.68m. The width of vertical passage(B) between student's tables is 0.7m. 4th, The area of teachers' is $2.1m{\sim}2.25m{\times}2.1m=4.41{\sim}4.73m^2$

Cultural Practices Affecting the Growth and Tuber Yield of Yam Bean (Pachyrhizus erosus L.) (얌빈 생육과 괴경 수량에 영향을 미치는 재배요인)

  • Nam, Hyo-Hoon;Kwon, Jung-Bai;Lee, Joong-Hwan;Son, Chang-Ki;Seo, Young-Jin
    • Korean Journal of Plant Resources
    • /
    • v.32 no.1
    • /
    • pp.38-44
    • /
    • 2019
  • This study was conducted to establish a domestic cultivation system of a newly introduced yam bean (Pachyrhizus erosus L.). Growth and yield were investigated in response to various cultural practices, such as seedling raising, planting distance, pinching, and flower pruning. Optimum conditions for raising of seedling were an average temperature of $22^{\circ}C$ for 30 days. Considering of the raising efficiency and the convenience of transplanting, 128 cells per tray was a suitable size. When pinching at a height of 120 cm from late July to early August, yield increased by 22% compared to no pinching. Flower pruning between late August and early September increased the number of tubers and tuber yield by 32% in comparison with no flower pruning. Yam bean seedlings planted at $50cm{\times}30cm$ spacing resulted in 30% yield increase as compared to wider spacing of $100cm{\times}30cm$. Our results thus suggested that the optimal combination of cultural practices ($50{\times}30cm$ planting distance, pinching at 120 cm height, and one time of flower pruning) increase profitability by 107%. All these results suggest high possibility of yam bean as a new income crop in Korea.

Study on the LNG Vaporization Characteristics of Open Rack Vaporizer(ORV) with Two-way Seawater Supplying System (해수 2단 공급에 따른 해수식 기화기(ORV)의 LNG 기화 특성 연구)

  • Kim, Nam-Kug;Yun, Sang-Kook
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.1
    • /
    • pp.41-46
    • /
    • 2019
  • LNG is supplying to consumers as gas phase vaporized by major seawater vaporizer, i.e.. open rack vaporizers. But as soon as the temperature of seawater drops below $5^{\circ}C$ in winter, the submerged evaporators should be operated and cause a lot of energy consumption because of their natural gas combustion. In order to reduce the consumption amount, in this study new two-way supplying method of seawater instead of the present one-way supplying system is introduced and analysed the technical possibilities and economical savings. The results showed that in case of the temperature of seawater becomes below $2.5^{\circ}C$, LNG can be evaporated using ORV without operating S MV. If this system is applied in Incheon LNG terminal, the energy saving reaches 11,770 Ton of LNG as 11,760 million won. By the analysis, the two-way supplying system of seawater in ORV can be the most effective method to be able to save huge amount of energy every year.

A Research of the Width of Passage in the Namyangju Elementary School Classroom (남양주 초등학교 일반교실의 통로 폭에 관한 조사 연구)

  • Yoon, Hee-Cheol
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.19 no.4
    • /
    • pp.60-69
    • /
    • 2020
  • This research is a preliminary study to find out the module of 20 students in a classroom. This research investigated the widths of passages in the 30 classrooms of 5 elementary schools in Namyangju City, Korea. The conclusions were as follows: First, the area of unit for 1 student was 650 (W) × 950 (D). Second, the desk placements for most classrooms were one-way types (87%), and group-study types constituted 13%. Third, the width between the blackboard and the very front desk was 2.17 m. The width of passage between the very back seat and the backside lockers was 1.32 m. The width of passage between the sidewall and the nearby desk was 0.8 m. The width of passage between the window and the nearby desk was 0.8 m. The average widths of 2 vertical passages between the desks were respectively 0.67 m and 0.68 m. Fourth, the area of the teacher was 2.1-2.25 m × 2.16 m = 4.5-4.8 ㎡.

Effects of Shiitake mushroom extract on antimicrobial activity against periodontopathogens and inflammatory condition of human gingival fibroblast (치주 질환관련 세균의 항균 및 세포 염증에 대한 표고버섯 추출물의 효과)

  • Jeon, Yeol-Mae
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.2
    • /
    • pp.90-96
    • /
    • 2022
  • Purpose: The purpose of this study was to investigate antimicrobial activity of extracts from shiitake mushroom against periodontopathogens and its cytotoxicity for human gingival fibroblast. Materials and Methods: Shiitake mushroom was soaked in water and acetone, and the supernatant was dried to collect its extract. The susceptibility of periodontopathogens for the extracts was investigated. Human gingival fibroblast was treated with the extracts, and the cell viability was measured CCK-8 solution. Results: The water extract from shiitake mushroom significantly reduced the growth of periodontopathogens at 2.5 mg/ml (P < 0.05). The acetone extract significantly inhibited the growth of Porphyromonas gingivalis and Tannerella forsythia at 0.32 mg/ml and Treponema denticola growth at 0.64 mg/ml (P < 0.05). The cytotoxicity of the extract was shown at a concentration of 2.5 mg/ml. The extracts with a concentration of 1.25 mg/ml appeared to be reduce cell viability after 4 h. Conclusion: The extracts of shiitake mushroom have antimicrobial activity against periodontitis-causing bacteria and relieving inflammation. Therefore, the extracts may be a candidate for preventing and treating periodontal disease.

The Factors influencing on the Interpersonal Caring Behavior of Clinical Nurses in COVID-19 (COVID-19 상황에서 임상간호사의 대인돌봄행위에 영향을 미치는 요인)

  • Lee, Sook;Choi, Ae-Sook;Yim, So-Youn;Chun, Yeol-Eo;Ryu, Young-Mi
    • Journal of Convergence for Information Technology
    • /
    • v.12 no.5
    • /
    • pp.246-255
    • /
    • 2022
  • This study aimed to identify the influence of caring character and knowledge of COVID-19 on interpersonal caring behavior of clinical nurses. The subjects were nurses working at one tertiary hospital in Seoul and two general hospitals in Gyeonggi province. The data were collected from October 15 to November 5, 2021. A total of 130 nurses participated in the online survey. The collected data were analyzed by performing stepwise multiple linear regression using SPSS/Win 27.0. As a result, the factors affecting the interpersonal caring behavior of clinical nurses were caring character (β=.50, p<.001), age (β=-.24, p=.002), and job satisfaction (β=.16, p=.040), and they explained 36.0% of caring behavior (F=24.49, p<.001). Therefore, it is necessary to improve caring character and job satisfaction to enhance the interpersonal caring behavior of clinical nurses. More efforts of the hospital should be made to provide caring character building education and to increase job satisfaction of clinical nurses.

Measurements of Void Concentration Parameters in the Drift-Flux Model (상대유량 모델내의 기포분포계수 측정에 관한 연구)

  • Yun, B.J.;Park, G.C.;Chung, C.H.
    • Nuclear Engineering and Technology
    • /
    • v.25 no.1
    • /
    • pp.91-101
    • /
    • 1993
  • To predict accurately the thermal hydraulic behavior of light water reactors during normal or abnormal operation, the accurate estimation of the void distribution is required. Up to date, many techniques for predicting void fraction of two-phase flow systems have been suggested. Among these techniques, the drift-flux model is widely used because of its exact calculation ability and simplicity. However, to get more accurate prediction of void fraction using drift-flux model, slip and flow regime effects must be considered more properly In the drift-flux method, these two effects are accounted for by two drift-flux parameters ; $C_{o}$ and (equation omitted). At earlier stage, $C_{o}$ is measured in a circular tube. In this study, $C_{o}$ is experimentally determined by measuring local void fraction and vapor velocity distribution in a rectangular subchannel having 4 heating rods which simulates nuclear subchannels. The measurements are peformed with two-electrical conductivity probes which are known to be adequate for measuring local parameters. The experiments are performed at low flow rate and the system pressure less than 3 atmo spheric pressure. In this experiment, (equation omitted), is not measured, but quoted from well-known empirical correlation to formulate $C_{o}$. Finally, $C_{o}$ is expressed as a function of channel averaged void fraction. fraction.

  • PDF

Evaluation of Performance of Grouts and Pipe Sections for Closed-loop Vertical Ground Heat Exchanger by In-situ Thermal Response Test (현장 열응답 시험을 통한 수직 밀폐형 지중열교환기용 그라우트와 열교환 파이프 단면의 성능 평가)

  • Lee, Chul-Ho;Park, Moon-Seo;Min, Sun-Hong;Choi, Hang-Seok;Sohn, Byong-Hu
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.7
    • /
    • pp.93-106
    • /
    • 2010
  • In performing a series of in-situ thermal response tests, the effective thermal conductivities of six vertical closed-loop ground heat exchangers were experimentally evaluated and compared one another, which were constructed in a test bed in Wonju. To compare thermal efficiency of the ground heat exchangers in field, the six boreholes were constructed with different construction conditions: grouting materials (cement vs. bentonite), different additives (silica sand vs. graphite) and the shape of pipe-sections (general U-loop type vs. 3 pipe-type). From the test results, it can be concluded that cement grouting has a higher effective thermal conductivity than bentonite grouting, and the efficiency of graphite better performs than silica sand as a thermally-enhancing addictive. In addition, a new 3 pipe-type heat exchanger provides less thermal interference between the inlet and outlet pipe than the conventional U-loop type heat exchanger, which results in superior thermal performance. Based on the results from the in-situ thermal response tests, a series of economic analyses have been made to show the applicability of the new addictives and 3 pipe-type heat exchanger.