• Title/Summary/Keyword: 자가 중합 레진

Search Result 101, Processing Time 0.041 seconds

INFLUENCE OF ADHESIVE APPLICATION ON SHEAR BOND STRENGTH OF THE RESIN CEMENT TO INDIRECT RESIN COMPOSITE (치과용 접착제가 복합레진 인레이와 레진시멘트의 결합력에 미치는 영향)

  • Song, Mi-Hae;Park, Su-Jung;Cho, Hyun-Gu;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.5
    • /
    • pp.419-427
    • /
    • 2008
  • This study analyzed the influence of dental adhesive/primer on the bond strength between indirect resin composite and the resin cement. Seventy disc specimens of indirect resin composite (Tescera Dentin, Bisco) were fabricated. And bonding area of all specimens were sandblasted and silane treated for one minute. The resin cements were used with or without application of adhesive/primer to bonding area of indirect resin restoration, Variolink-II (Ivoclar-Vivadent) : Exite DSC, Panavia-F (Kuraray) : ED-Primer, RelyX Unicorn (3M ESPE) Single- Bond, Duolink (Risco) : One-step, Mulitlink (Ivoclar-Vivadent) : Multilinh Primer. Shear bond strength was measured by Instron universal testing machine. Adhesive application improved shear bond strength (p<0.05) But Variolink II and Panavia-F showed no statistically significant difference according to the adhesive application. With the above results, when resin inlay is luted by resin cement it seems that application of dental adhesive/primer is necessary in order to improve the bond strength.

Shear Bond Strength of Resin Cements on the IPS e.max Press (IPS e.max Press에 대한 수종 레진 시멘트의 전단결합강도에 관한 연구)

  • Lee, Kyung-Eun;Kim, Yu-Lee;Shin, Chang-Yong;Dong, Jin-Keun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.311-322
    • /
    • 2010
  • The purpose of this study was to evaluate the bond strengths between IPS e.max Press and four different types of resin cements that often used for esthetic restoration. Disc shaped IPS e.max Press blocks(N=40, diameter: 12mm, thickness: 3mm) were fabricated according to the manufacture's instruction and cleaned with ultrasonic cleaner. They were embedded into an autopolymerizing acrylic resin. Fourty cylinder shaped resin block(Filtek Z350, diameter: 4.5mm, thickness: 3mm) were fabricated using a plastic tube. Each specimens were randomly divided into 4 experimental group and bonded each other using 4 different resin cements(Variolink II(light-cure), Variolink II(dual-cure), Calibra, Super-Bond C&B) according to the manufactures' recommendations. All the specimens were stored in normal saline at $37^{\circ}C$ for 24 hours before test. Universal testing machine at a crosshead speed of 1mm/min was used to evaluate the shear bond strength. The data were statistically analyzed using one-way ANOVA(P<.01). Multiple comparison was done by the Tukey HSD test. The shear bond strength of Super-Bond C&B to e.max was significantly lower than those of Calibra, Variolink II(light-cure), Variolink II(dual-cure) (P<.01). The shear bond strength of Calibra, Variolink II(light-cure), Variolink II(dual-cure) to e.max were not significantly different. The shear bond strengths of light-cure/dual-cure cement were higher than that of self-cure cement.

EFFECT OF AN INTERMEDIATE BONDING RESIN AND FLOWABLE RESIN ON THE COMPATIBILITY OF TWO-STEP TOTAL ETCHING ADHESIVES WITH A SELF-CURING COMPOSITE RESIN (자가 중합 복합 레진과 두 단계 산 부식 접착제의 친화성에 대한 중간 접착제와 흐름성 레진의 효과)

  • Choi, Sook-Kyung;Yum, Ji-Wan;Kim, Hyeon-Cheol;Hur, Bock;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.5
    • /
    • pp.397-405
    • /
    • 2009
  • This study compared the effect of an activator, intermediate bonding resin and low-viscosity flowable resin on the microtensile bond strength of a self-curing composite resin used with two-step total etching adhesives. Twenty extracted permanent molars were used. The teeth were assigned randomly to nine groups (n=10) according to the adhesive system and application of additional methods (activator, intermediate adhesive, flowable resin). The bonding agents and additional applications of each group were applied to the dentin surfaces. Self-curing composite resin buildups were made for each tooth to form a core, 5mm in height. The restored teeth were then stored in distilled water at room temperature for 24h before sectioning. The microtensile bond strength of all specimens was examined. The data was analyzed statistically by one-way ANOVA and a Scheffe's test. The application of an intermediate bonding resin (Optibond FL adhesive) and low-viscosity flowable resin (Tetric N-flow) produced higher bond strength than that with the activator in all groups. Regardless of the method selected, Optibond solo plus produced the lowest ${\mu}TBS$ to dentin. The failure modes of the tested dentin bonding agents were mostly adhesive failure but there were some cases showed cohesive failure in the resin.

Influence of Thickness on the Degree of Cure of Composite Resin Core Material (코어용 레진의 두께가 중합에 미치는 영향)

  • Kwon, Pyoung-Cheol;Park, Jeong-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.5
    • /
    • pp.352-358
    • /
    • 2006
  • The purpose of this study was to investigate the influence of thickness on the degree of cure of dual-cured composite core. 2, 4, 6, 8 mm thickness Luxacore Dual and Luxacore Self (DMG Inc, Hamburg, Germany) core composites were cured by bulk or incremental filling with halogen curing unit or self-cure mode The specimens were stored at $37^{\circ}C$ for 24 hours and the Knoop's hardness of top and bottom surfaces were measured. The statistical analysis was performed using ANOVA and Tukey's test at p = 0.05 significance level. In self cure mode, polymerization is not affected by the thickness. In Luxacore dual, polymerization of the bottom surface was effective in 2, 4 and 6 (incremental) mm specimens. However the 6 (bulk) and 8 (bulk, incremental) mm filling groups showed lower bottom/top hardness ratio (p < 0.05). Within the limitation of this experiment, incremental filling is better than bulk filling in case of over 4 mm depth, and bulk filling should be avoided.

The Effect of Bonding Resin on Bond Strength of Dual-Cure Resin Cements (접착레진의 부가도포가 레진 시멘트의 결합강도에 미치는 영향에 대한 연구)

  • Kim, Duck-Su;Park, Sang-Hyuk;Choi, Gi-Woon;Choi, Kyung-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.5
    • /
    • pp.426-436
    • /
    • 2007
  • The objective of this study is to evaluate the effect of an additional application of bonding resin on the bond strength of resin luting cements in both the light-cure (LC) and self-cure (SC) modes by means of the ${\mu}TBS$ tests. Three combinations of One-Step Plus with Choice, Single Bond with Rely X ARC, and One-Up Bond F with Bistite II were used. D/E resin and Pre-Bond resin were used for the additional application. Twelve experimental groups were made. Three mandibular $3^{rd}$ molars were used in each group. Indirect composite blocks were cemented on the tooth surface. $1\;{\times}\;1\;mm^2$ dentin-composite beam for ${\mu}TBS$ testing were made and tested. When total-etching dentin adhesives were used, an additional application of the bonding resin increased the bond strength (P < 0.05). However, this additional application didn't influence the bond strength of self-etching dentin adhesives (P > 0.05). In conclusion, the results suggest that an additional application of the bonding resin increases bond strength and enhances quality of bonding when using total-etching dentin adhesives.

Polymerization of dual cured composites by different thickness (두께에 따른 이중 중합형 복합레진의 중합)

  • Kim, Yun-Ju;Jin, Myoung-Uk;Kim, Sung-Kyo;Kwon, Tae-Yub;Kim, Young-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.3
    • /
    • pp.169-176
    • /
    • 2008
  • The purpose of this study was to evaluate the effect of thickness, filling methods and curing methods on the polymerization of dual cured core materials by means of microhardness test. Two dual cured core materials, MultiCore Flow (Ivoclar Vivadent AG, Schaan, Liechtenstein) and Bis-Core (Bisco Inc., Schaumburg, IL, USA) were used in this study. 2 mm (bulky filled), 4 mm (bulky filled), 6 mm (bulky and incrementally filled) and 8 mm (bulky and incrementally filled)-thickness specimens were prepared with light cure or self cure mode. After storage at $37{\circ}C$ for 24 hours, the Knoop hardness values (KHN) of top and bottom surfaces were measured and the microhardness ratio of top and bottom surfaces was calculated. The data were analyzed using one-way ANOVA and Scheffe multiple comparison test, with ${\alpha}$= 0.05. The effect of thickness on the polymerization of dual cured composites showed material specific results. In 2, 4 and 6 mm groups, the KHN of two materials were not affected by thickness. However, in 8 mm group of MultiCore Flow, the KHN of the bottom surface was lower than those of other groups (p < 0.05). The effect of filling methods on the polymerization of dual cured composites was different by their thickness or materials. In 6 mm thickness, there was no significant difference between bulk and incremental filling groups. In 8 mm thickness, Bis-Core showed no significant difference between groups. However, in MultiCore Flow, the microhardness ratio of bulk filling group was lower than that of incremental filling group (p < 0.05). The effect of curing methods on the polymerization of dual cured composites showed material specific results. In Bis-Core, the KHN of dual cured group were higher than those of self cured group at both surfaces (p < 0.05). However, in MultiCore Flow, the results were not similar at both surfaces. At the top surface, dual cured group showed higher KHN than that of self cured group (p < 0.05). However, in the bottom surface, dual cured group showed lower value than that of self cured group (p < 0.05).

Polymerization of dual cured composites by different thickness (두께에 따른 이중 중합형 복합레진의 중합)

  • Kim, Yun-Ju;Jin, Myoung-Uk;Kim, Sung-Kyo;Kwon, Tae-Yub;Kim, Young-Kyung
    • Proceedings of the KACD Conference
    • /
    • 2008.05a
    • /
    • pp.169-176
    • /
    • 2008
  • The purpose of this study was to evaluate the effect of thickness, filling methods and curing methods on the polymerization of dual cured core materials by means of microhardness test. Two dual cured core materials, MultiCore Flow (Ivoclar Vivadent AG, Schaan, Liechtenstein) and Bis-Core (Bisco Inc., Schaumburg, IL, USA) were used in this study. 2 mm (bulky filled), 4 mm (bulky filled), 6 mm (bulky and incrementally filled) and 8 mm (bulky and incrementally filled)-thickness specimens were prepared with light cure or self cure mode. After storage at $37^{\circ}C$ for 24 hours, the Knoop hardness values (KHN) of top and bottom surfaces were measured and the microhardness ratio of top and bottom surfaces was calculated. The data were analyzed using one-way ANOVA and Scheffe multiple comparison test, with ${\alpha}=0.05$. The effect of thickness on the polymerization of dual cured composites showed material specific results. In 2, 4 and 6 mm groups, the KHN of two materials were not affected by thickness. However, in 8 mm group of MultiCore Flow, the KHN of the bottom surface was lower than those of other groups (p < 0.05). The effect of filling methods on the polymerization of dual cured composites was different by their thickness or materials. In 6 mm thickness, there was no significant difference between bulk and incremental filling groups. In 8 mm thickness, Bis-Core showed no significant difference between groups. However, in MultiCore Flow, the microhardness ratio of bulk filling group was lower than that of incremental filling group (p < 0.05). The effect of curing methods on the polymerization of dual cured composites showed material specific results. In Bis-Core, the KHN of dual cured group were higher than those of self cured group at both surfaces (p < 0.05). However, in MultiCore Flow, the results were not similar at both surfaces. At the top surface, dual cured group showed higher KHN than that of self cured group (p < 0.05). However, in the bottom surface, dual cured group showed lower value than that of self cured group (p < 0.05).

  • PDF

Mechanical properties by resin injection method of orthdontic acrylic resin (교정용 레진장치의 레진주입방법에 따른 기계적 특성)

  • Jo, Jeong-Ki
    • Journal of Digital Convergence
    • /
    • v.18 no.4
    • /
    • pp.341-346
    • /
    • 2020
  • Polymethyl methacrylate (PMMA), a self-curing resin mainly used in removable orthodontic appliances, is an acrylic resin mainly used in the field of modern dentistry. As an advantage, it has been used for a long time as a material for orthodontic devices in dentistry due to its color and volume, tissue affinity, and stability. The production of PMMA can be divided into self-polymerization method and thermal polymerization method according to activation method. Self-curing resins have long been used as orthodontic devices. The resin injection method is largely divided into a sprinkle-on method and a mixing method. In this study, we intend to test the mechanical properties according to the resin injection method of the orthodontic device, such as strength, modulus of elasticity, and surface roughness. There was no significant difference in strength as a result of three-point bending strength test on rectangular specimens (1.4 × 3.0 × 19.0 mm) of orthodontic PMMA. There was also no significant difference in hardness. There was no significant difference in surface roughness. It was confirmed that the orthodontic PMMA had no significant difference in mechanical properties according to the resin injection method of the orthodontic device.

A STUDY ON THE EFFECT OF POLYMERIZATION SHRINKAGE OF SEVERAL COMPOSITE RESIN USING STRAIN GAUGE (스트레인 게이지를 이용한 수종 수복재의 중합수축 영향 평가)

  • Lee, In-Cheon;Kim, Jong-Soo;Yoo, Seung-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.1
    • /
    • pp.20-29
    • /
    • 2009
  • This study was performed to evaluate the effect of the shrinkage stress induced by polymerization process of several light curing filling materials according to filling methods. High power light curing unit which has a plasma arc lamp was used and filling materials used were Filtek $Z-250^{(R)}$ composite resin, $Dyract^{(R)}$ AP compomer and $Tetric^{(R)}$ Flow flowable composite resin. Cavities were prepared on the permanent molars with width 3 mm, height 3 mm and depth 1.5 mm and the filling materials were filled with 1 step, 2 step layering technique and 3 step oblique filling methods. The results can be summarized as follows; 1. Strain values showed rapid increase from the start of light curing followed by gradual decrease afterwards with time. 2. Although the shrinkage stress value of $Z-250^{(R)}$ were shown to be relatively higher than $Dyract^{(R)}$ AP and $Tetric^{(R)}$ Flow, no statistically significant could be found between tested materials(p>0.05). 3. There were no statistically significant difference between 3 filling methods when using $Dyract^{(R)}$ AP and $Z-250^{(R)}$(p>0.05). 4. There were no statistically significant difference between shrinkage stress values obtained from samples prepared by different filling methods and materials(p>0.05).

  • PDF

Three Dimensional Comparative Study On The Accuracy Of Impression Technique Using New Impression Coping (새로운 인상용 코핑을 이용한 임플란트 인상법의 정확성에 대한 3차원적 비교 연구)

  • Kim, Se-Ra;Kim, In-Soo;Park, Sung-Jae;Lee, Byung-Ok;Ko, Sok-Min
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.323-337
    • /
    • 2010
  • The objective of this study was to examine the availability of the new impression coping by comparing with conventional coping in implant pick-up impression technique. Five implant fixtures were installed on #14, 21, 23, 25, 27 in acrylic resin model. That model with 5 fixtures was standard model, which was divided 3 groups; using new flag type impression coping, conventional impression coping splinted with self-curing resin, conventional impression coping without splinting. We made metal circular cones for calculation 3-dimensional coordinates by attaching to implant fixtures or analogs. Three-dimensional relationships of each model were calculated. Data was analyzed by multiple ANOVA and Bonferroni. The accuracy of impression between using new flag type impression coping and conventional impression coping did not show differences in 3 - dimensional analysis.Within limitations of this study, the new flag type impression coping is available in implant pick-up impression technique.