• Title/Summary/Keyword: 에너지코드

Search Result 413, Processing Time 0.031 seconds

Numerical Modeling of Physical Property and Electrochemical Reaction for Solid Oxide Fuel Cells (고체 산화물 연료전지를 위한 물성치 및 전기화학반응의 수치해석 모델링)

  • Park, Joon-Guen;Kim, Sun-Young;Bae, Joong-Myeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.2
    • /
    • pp.157-163
    • /
    • 2010
  • Solid oxide fuel cells (SOFCs) are commonly composed of ceramic compartments, and it is known that the physical properties of the ceramic materials can be changed according to the operating temperature. Thus, the physical properties of the ceramic materials have to be properly predicted to develop a highly reliable simulation model. In this study, several physical properties that can affect the performance of SOFCs were selected, and simulation models for those physical properties were developed using our own code. The Gibbs free energy for the open circuit voltage, exchange current densities for the activation polarization, and electrical conductivity for the electrolyte were calculated. In addition, the diffusion coefficient-including the binary and Knudsen diffusion mechanisms-was calculated for mass transport analysis at the porous electrode. The physical property and electrochemical reaction models were then simulated simultaneously. The numerical results were compared with the experimental results and previous works studied by Chan et al. for code validation.

Development of Liquid Metal Passive Cooling Flow Simulation System (액체금속 피동냉각유동모사 실증설비의 개발)

  • Ryu, Kyung-Ha;Kim, Jae-Hyoung;Lee, Tae-Hyun;Lee, Sang-Hyuk;Bahn, Byoung-Min
    • Transactions of the KSME C: Technology and Education
    • /
    • v.3 no.4
    • /
    • pp.257-264
    • /
    • 2015
  • To maintain sustainability of nuclear energy as an important energy source, both safety problem and Spent Nuclear Fuels(SNFs) problem should be solved. In case of Gen-IV reactors such as fast reactor, SNFs can be used as fuels by using fast neutrons. It can be a suitable treatment method of high-level waste in near future. Liquid metals such as Sodium or Lead-Bismuth Eutectic (LBE) can be possibly used as a coolant to use fast neutrons. In this paper, it was described that natural circulation parameter studies, design analyses, material selections and a completion of facilities. To develop a natural circulation facility, thermal hydraulic analyses were performed. Installation technique of liquid metal natural circulation were secured.

Characteristics of Temperature in Reformer Tube and Chemical Reaction for Steam Methane Ratio (수증기-메탄 혼합비에 따른 개질 튜브 내 온도 및 화학반응 특성)

  • Han, Jun Hee;Kim, Ji Yoon;Lee, Seong Hyuk
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.5
    • /
    • pp.27-33
    • /
    • 2016
  • The aim of numerical study is the investigation of the solid and fluid temperatures in a reformer tube and chemical reaction characteristics of different steam-carbon ratio. We considered conjugate heat transfer contain radiation, convection and conductive heat transfers. This is because steam reforming reaction of hydrocarbon occurred high temperature conditions up to 800 K- 1000 K by using commercial computational fluid dynamics (CFD) code (Fluent ver. 13.0). For numerical simulation, the Reynolds-Averaged Navier-Stokes, momentum and energy equation were employed. In addition, inside of reformer tube is assumed as the porous medium to consider the Nichrome-based catalyst. To analysis characteristics of tube temperature in chemical reaction, we changed steam-methane ratio(SCR) from 1 to 6. As increased SCR, the higher tube temperature and methane conversion were observed. It was obtained that the highest hydrogen production held in SCR of 5.

Storage Assignment for Variables Considering Efficient Memory Access in Embedded System Design (임베디드 시스템 설계에서 효율적인 메모리 접근을 고려한 변수 저장 방법)

  • Choi Yoonseo;Kim Taewhan
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.32 no.2
    • /
    • pp.85-94
    • /
    • 2005
  • It has been reported and verified in many design experiences that a judicious utilization of the page and burst access modes supported by DRAMs contributes a great reduction in not only the DRAM access latency but also DRAM's energy consumption. Recently, researchers showed that a careful arrangement of data variables in memory directly leads to a maximum utilization of the page and burst access modes for the variable accesses, but unfortunately, found that the problems are not tractable, consequently, resorting to simple (e.g., greedy) heuristic solutions to the problems. In this parer, to improve the quality of existing solutions, we propose 0-1 ILP-based techniques which produce optimal or near-optimal solution depending on the formulation parameters. It is shown that the proposed techniques use on average 32.2%, l5.1% and 3.5% more page accesses, and 84.0%, 113.5% and 10.1% more burst accesses compared to OFU (the order of first use) and the technique in [l, 2] and the technique in [3], respectively.

LES of Turbulent Mixing of Non-Reactive Flow in Gas Generator (가스발생기 비-반응 유동의 난류 혼합에 대한 LES 해석)

  • Lee, Chang-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.12
    • /
    • pp.1171-1179
    • /
    • 2008
  • LES analysis was conducted with in-house CFD code to investigate the turbulence evolution and interaction due to turbulence ring and splash plate in the gas generator. The calculation results show that the installation of turbulence ring can introduce additional turbulences and significantly improve turbulent mixing in the downstream flow. However, the addition of splash plate in the downstream of TR(Turbulence Ring) brings totally different shape of perturbation energy and enstrophy distribution into turbulent mixing. This enhancement can be done by the formation of the intensively strong vorticity and mixing behind the plate. Pressure drop was found to be a reasonable level of about 1% or less of initial pressure in all calculation cases. Also, calculation results revealed that the variation of shape and intrusion length of TR did not greatly affect the characteristics of turbulent mixing in the chamber. Even though the effect of installation location of splash plate on the turbulent mixing was not investigated yet, calculation results conclude the addition of splash plate leads to the increase in turbulent mixing with an acceptable pressure drop.

Thermomechanical Analysis of Composite Structures in Pyrolysis and Ablation Environments (열분해 및 삭마 환경의 복합재 구조물의 열기계적 연계 해석)

  • Choi, Youn Gyu;Kim, Sung Jun;Shin, Eui Sup
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.8
    • /
    • pp.597-604
    • /
    • 2013
  • A coupled thermomechanical analysis of composite structures in pyrolysis and ablation environments is performed. The pyrolysis and ablation models include the effects of mass loss, pore gas diffusion, endothermic reaction energy, surface recession, etc. The thermal and structural analysis interface is based upon a staggered coupling algorithm by using a commercial finite element code. The characteristics of the proposed method are investigated through numerical experiments with carbon/phenolic composites. The numerical studies are carried out to examine the surface recession rate by chemical and mechanical ablation. In addition, the effects of shrinkage or intumescence during the pyrolysis process are shown.

Flow Characteristics of R600a in an Adiabatic Capillary Tube (단열 모세관내 R600a의 유동 특성)

  • Ku, Hak-Geun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.2
    • /
    • pp.449-454
    • /
    • 2010
  • In this paper, flow characteristics of R600a in an adiabatic capillary tube were investigated employing the homogeneous flow model. The model is based on fundamental equations of mass, energy and momentum which are solved simultaneously. Two friction factors(Churchill) and viscosity(McAdams) are comparatively used to investigate the flow characteristics. Thermodynamic and transport properties of R600a are calculated employing EES property code. Flow characteristics analysis of R600a in an adiabatic capillary tube is presented to offer the basic design data for the operating parameters. The operating parameters considered in this study include condensation temperature, evaporation temperature, subcooling degree and inner diameter tube of the adiabatic capillary tube. The main results were summarized as follows: condensation and evaporation temperature, inlet subcooling degree and inner diameter tube of an adiabatic capillary tube using R600a have an effect on length of an adiabatic capillary tube. The length of an adiabatic capillary tube using R600a is expressed to the correlation shown in Eq. (15).

A 3 V 12b 100 MS/s CMOS DAC for High-Speed Communication System Applications (고속통신 시스템 응용을 위한 3 V 12b 100 MS/s CMOS D/A 변환기)

  • 배현희;이명진;신은석;이승훈;김영록
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.9
    • /
    • pp.685-691
    • /
    • 2003
  • This work describes a 3 V 12b 100 MS/s CMOS digital-to-analog converter (DAC) for high-speed communication system applications. The proposed DAC is composed of a unit current-cell matrix for 8 MSBs and a binary-weighted array for 4 LSBs, considering linearity, power consumption, chip area, and glitch energy. The low-glitch switch driving circuit is employed to improve the linearity and the dynamic performance. Current sources of the DAC are laid out separately from the current-cell switch matrix core. The prototype DAC is implemented in a 0.35 urn n-well single-poly quad-metal CMOS technology. The measured DNL and INL of the prototype DAC are within $\pm$0.75 LSB and $\pm$1.73 LSB, respectively, and the spurious-free dynamic range (SFDR) is 64 dB at 100 MS/s with a 10 MHz input sinewave. The DAC dissipates 91 mW at 3 V and occupies the active die area of 2.2 mm ${\times}$ 2.0 mm.

Monte Carlo Simulation for absorbed dose in PMMA phantom during the low-energy X-ray irradiation (저 에너지 X선 조사 시 PMMA 팬텀 내의 흡수선량 평가를 위한 몬테카를로 시뮬레이션)

  • Kim, Sang-Tae;Kang, Sang-Koo;Kim, Chong-Yeal
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.383-389
    • /
    • 2011
  • This study offered a new method to calculate absorbed dose of actual patients through Monte Carlo Simulation by using the linkage of Geant4 and DICOM, and, the experimental value of absorbed dose at the center and Geant 4 simulation result according to the depth of PMMA mock phantom were compared by using MOSEF in order to verify Geant4 calculation code. In the area where there was no air space between the irregular gap due to incomplete compression of PMMA slab, the differences were $0.46{\pm}4.69$ percent and $-0.75{\pm}5.19$percent in $15{\times}15cm^2$ and $20{\times}20cm^2$ respectively. Excluding the error due to incomplete compression of PMMA mock phantom, the calculation values of the Monte Carlo simulation by linkage of Geant4 and DICOM was the same.

Common Data Model for Network Analysis Applications of K-EMS (K-EMS 계통해석 어플리케이션을 위한 공통 데이터 모델 구축)

  • Yun, S.Y.;Cho, Y.S.;Lee, U.H.;Sohn, J.M.;Nam, Y.W.;Lee, J.;Kim, H.R.;Kim, B.H.;Kim, S.G.;Hur, S.I.;Lee, H.S.;Shin, M.C.;Min, K.I.;Choi, Y.J.
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.75-76
    • /
    • 2008
  • 본 논문에서는 한국형 에너지 관리 시스템의 계통 해석용 프로그램을 위한 공통 데이터 모델의 구축에 대해 다루었다. 공통 데이터 모델이란 다양한 어플리케이션이 공유하여 사용할 수 있는 계통 모델의 데이터베이스를 가리키며 본 논문에서는 토폴로지 프로세서(topology processor, TP), 상태추정(state estimator, SE), 급전원 조류계산(dispatcher power flow, DPF), 휴전계획(outage scheduler, OS), 부하 분포계수(bus load distribution factor, BLDF), 송전 손실 민감도 계수(transmission loss sensitivity factor, TLSF) 등을 위한 공통 모델에 대해 다루었다. 공통 모델의 구축을 위해 각 어플리케이션에서 필요한 정보를 수집하여 전력계통의 토폴로지 구조과 계통 설비를 모델링 하였다. 최종적으로 계층적(hierarchy) 구조와 비계층적(non-hierarchy) 구조로 나뉘어진 직접(direct) 및 간접(indirect) 인덱스 코드를 사용하여 데이터로의 빠른 접근이 가능한 실시간 데이터베이스 형태를 제시하였다.

  • PDF