• Title/Summary/Keyword: 삼각파

Search Result 118, Processing Time 0.038 seconds

Multimode Analysis of a Rectangular Cavity Partially Filled with Dielectric (유전체로 일부 채워진 직육면체 캐비티의 다중모드 해석)

  • 김채영;나정웅
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.16 no.1
    • /
    • pp.9-13
    • /
    • 1979
  • Multimode characteristics of a dielectrically loaded rectangular cavity are analyzed by a graphical method. Coupled transcendental equations for multimode frequencies may be solved graphlially. This shows that the resonant frequencies of the partially flued cavity with a dielectic are shifted toward lower frequencies compared to those of the empty cavity. It is shown that a perturbational scheme can not be employed to calculate multimode frequencies because of relatively large frequency shrift. Existence of the surface wave modes In the dielectric and their resonant frequencies are early predicted from this graphical method.

  • PDF

Analysis of Various gate operation effects at Nakdong Estuary (낙동강하구둑 수문운영 변화에 따른 영향 분석)

  • Lee, Sang-Jin;Park, Joo-Seong;Hwang, Man-Ha;Ryoo, Kyong-Sick;Lee, Bae-Sung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.2074-2078
    • /
    • 2007
  • 본 연구는 우리나라 4대강 중에서 국내유일의 조석/파랑 혼합 삼각주 형태의 하구인 낙동강 하구둑을 대상으로 효율적인 수문운영을 통해 해역에 지속적으로 담수를 공급하여 기수역을 확보할 수 있는 방안을 모색하고자 하구둑 수위조정에 따른 수질 및 염분도 변화에 대하여 분석하였다. 그 결과 수위의 상향조정으로 인하여 수문개방 확률을 95% 이상 증가 시킬 수 있는 것으로 분석되었고, 상시 방류를 통하여 자연 상태에 가까운 하구 생태환경의 조성이 가능할 것으로 기대된다.

  • PDF

SV-PWAM Control Based High-Efficiency Inverter for Electric Vehicle (전기자동차 구동용 인버터의 고효율 SV-PWAM 제어기법)

  • Cho, Choon-Ho;Kim, Dong-Hyun;Byeon, Cheol-Hong;Min, Wan-Ki;Choi, Jaeho;Kim, Tae-Woong
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.372-373
    • /
    • 2013
  • 본 논문에서는 전기자동차의 효율적인 구동을 위해 3상 전압 형인버터를 기존 삼각파비교방식의 PWAM 기법을 탈피하고 공간벡터 비교방식의 새로운 PWAM 기법을 제안한다. 공간벡터 변조방식의 장점인 자유도가 높은 특징을 살려 3상 전압형 인버터의 스위칭절환이 최소로 이루어지도록 벡터인가시간과 스위칭 룩업테이블을 설계하고, 시뮬레이션 및 실험 해석을 통해 유효성을 검증한다.

  • PDF

Design of A Wavelet Interpolation Filter for Elimination of Muscle Artifact in the Stress ECG (스트레스 심전도의 근잡음 제거를 위한 Wavelet Interpolation Filter의 설계)

  • 박광리;이경중;이병채;정기삼;윤형로
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.5
    • /
    • pp.495-503
    • /
    • 2000
  • 스트레스 심전계에서 발생되는 근잡음을 제거하기 위하여 wavelet interpolation filter(WIF)를 설계하였다. WIF는 크게 웨이브렛 변환부와 보간법 적용부로 구성되어 있다. 웨이브렛 변환부는 Haar 웨이브렛을 이용하였으며 심전도 저주파 영역과 고주파 영역으로 분할하는 과정이다. 보간법 적용부에서는 분할되어진 신호 중 A3을 선택하여 신호의 재생 성능을 향상시키기 위하여 보간법을 적용하였다. WIF의 성능을 평가하기 위해서 신호대 잡음비, 재생신호 자승오차 및 표준편차의 파라미터를 이용하였다. 본 실험에서는 MIT/BIH 부정맥 데이터베이스, European ST-T 데이터베이스 및 삼각파형을 이용하여 성능 파라미터를 측정하였다. 결과적으로 WIF는 성능 파라미터에서 기존에 많이 사용되고 있는 평균값 필터, 중간값 필터 및 hard thresholding 방법에 비해 우수함을 알 수 있었다.

  • PDF

Development of A DC Motor Controller for 24V-500W Small Electric Vehicle (24V-500W급 소형전동차용 DC모터 속도 콘트롤러 개발)

  • Bang, Jun-Ho;Lee, Woo-Choun;Yu, Jae-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.4
    • /
    • pp.1777-1783
    • /
    • 2012
  • In this paper, a new motor driving circuit is designed to improve the output performance of DC motor, and a controller is developed with the designed circuit. By the designed driving circuit, a controller can continuously drive DC motors by a transformer which has switching signals of a self-generated circuit to operate it. And while the DC motor have a maximum velocity, the reference voltage can be maintained higher value than that of triangle voltage and it makes the DC motor driving transistor ON and maximum power. A 24V-500W DC motor controller is developed with the proposed motor driving circuit, and also a small electric car is made and the driving test of it is executed. The test results shows that it can continuously control go and back speed of motor with 12A driving current. And also, it is verified that the over current and heat detecting function is operating correctly and the rest value of the used battery can be displayed as 6 step from 20 to 100%.

A Study on the Contact Seam Tracking Sensor by Using Strain Gauges (스트레인 게이지를 이용한 접촉식 용접선 추적 센서에 관한 연구)

  • 안병원;배철오;김현수
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.5
    • /
    • pp.1019-1025
    • /
    • 2003
  • There are many kinds of seam trackers in the industrial welding field. We are proposed the contact seam tracking sensor applying strain gauges kind of contact sensor that mostly used in welding part now. For this seam tracking experiment, we made the strain gauges sensor by ourselves and tested how well the sensor tracks the seam. The experiment device consist of strain gauges sensor, amplifier circuit of strain gauges signal, saw wave generator, MOSFET power diving circuit and X-Y slide by moved DC motor. The tracking areas are X-Y planes(left, right, up and down) and the change of strain gauge resistance causes to move DC motor that connected to X-Y slide. As a result of experiment, we confirmed that the strain gauges sensor tracks a seam well, and X-Y slide DC motor was controlled by PWM control.

A Study on the Neutral Point Potential Variation under Open-Circuit Fault of Three-Level NPC Inverter (3레벨 NPC 인버터 개방성 고장 시 중성점 전압변동에 관한 연구)

  • Park, Jong-Je;Park, Byoung-Gun;Ha, Dong-Hyun;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.333-342
    • /
    • 2009
  • Three-level Diode Clamped Multilevel Inverter, generally known as Neutral-Point-Clamped (NPC) Inverter, has an inherent problem causing Neutral Point (NP) potential variation. Until now, in many literatures NP potential problem has been investigated and lots of solutions have also been proposed. However, under fault and fault tolerant control, distinctive feature for NP potential variation problem was rarely published from the standpoint of reliability. In this paper, NP potential is analytically investigated both normal and faulty conditions under carrier based PWM. Subsequently, relation between fault detection time and size of capacitor is analyzed. This information is explored by simulation and experiment results, which contribute to enhance the reliability of inverter system.

다중 전원을 이용한 듀얼 랑뮤어 프루브 시스템을 통한 플라즈마 진단

  • Kim, Hyeok;Lee, U-Hyeon;Hwang, Gi-Ung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.214-215
    • /
    • 2011
  • RF 플라즈마의 경우 일반적인 싱글 랑뮤어 프루브를 사용하여 I-V 파형을 구하는 경우에, 우리는 시평균한 값만을 구할 수 있다. 일반적인 플라즈마 반응 챔버의 구조상, 양 전극의 크기가 다르기 때문에, 시간에 따라 진동하는 플라즈마 포텐셜의 형태는 정확한 사인파의 형태가 아니다. 그렇기 때문에 플라즈마 포텐셜에 따라서 진동하는 데이터를 시평균한 값에는 DC 오프셋 성분이 나타난다. 이러한 DC 오프셋값은 랑뮤어 프루브를 통한 플라즈마 포텐셜 측정시에 오차로 나타난다. 우리는 DC 오프셋에 의한 에러값을 보정하기 위해 멀티 프루브를 사용할 수 있다. 가장 흔하게 쓰이는 듀얼 랑뮤어 프루브의 경우를 살펴보면, 내부의 전원이 플로팅되어 있으며 전압인가를 위한 회로 또한 접지에서 절연되어 있기 때문에, 플라즈마 포텐셜이 시간에 따라 흔들려도 전체적인 전위가 플라즈마 포텐셜과 함께 움직이기 때문에, 앞에서 말한 DC 오프셋에 의한 오차를 줄일 수있다는 장점이 있다. 그러나, 이를 위하여는 회로의 절대적인 플로팅이 필요하지만 실제 듀얼 랑뮤어 프루브의 전원 회로를 구현시에는, 트랜스포머 등을 사용하여 회로를 절연시켜도 회로에 기생적으로 발생하는 콘덴서 성분 때문에 플로팅에 영향을 받을 수 있다. 또한 양극과 음극 사이의 내부 임피던스가 다르게 나타난다. 실제로 기존의 듀얼 랑뮤어를 가지고 RF 플라즈마를 측정할 때에, 듀얼 랑뮤어 프루브의 두 팁 간에 서로 다른 전압-전류 파형이 나타나곤 한다. 이러한 두 팁간의 전압-전류 파형의 차이는 두 팁이 물리적으로 완전히 동일한 구조를 가질 수 없기 때문에 발생 하기도 하지만, 위에서 밝힌 원인에 의해서도 발생한다. 이로 인하여 듀얼 랑뮤어 프루브에 의한 I-V 파형은 이론 상 원점을 대칭으로 한 기함수의 형태이어야 하는데, 실제 측정 결과를 보면 이러한 대칭 형태의 모양을 보기 힘들다. 우리는 이에 이를 보정하기 위하여 위상이 180도 차이가 나는 두 개의 삼각파 발생 전원을 각각 듀얼 랑뮤어 프루브의 양 팁에 인가하여 두 팁 간의 내부 저항과 기생 임피던스 등을 일치시킨 프루브를 디자인하였으며 이 프루브를 이용한 실험에서, 비교적 완벽하게 원점에 대하여 대칭하는 I-V 커브를 구할 수 있었다. 이에 이 논문에서는 새로운 회로와 이 회로로 이루어진 듀얼 랑뮤어 프루브를 사용하여 플라즈마를 진단하는 방법에 대하여 기술한다.

  • PDF

Design of Hysteretic Buck Converter with A Low Output Ripple Voltage and Fixed Switching Frequency in CCM (작은 출력 전압 리플과 연속 전도모드에서 고정된 스위칭 주파수를 가지는 히스테리틱 벅 변환기 설계)

  • Jeong, Tae-Jin;Jo, Yong-Min;Lee, Tae-Heon;Yoon, Kwang Sub
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.6
    • /
    • pp.50-56
    • /
    • 2015
  • An efficient fast response hysteretic buck converter suitable for mobile application is propoesed. The problems of large output ripple and difficulty in using of small power inductor that conventional hysteretic converter has are improved by adding ramp generator. and the changeable switching frequency with load current is fixed by adding a delay time control circuit composed of PLL structure resulting in decrease of EMI noise. The circuits are implemented by using BCDMOS 0.35um 2-polt 4-metal process. Measurement results show that the converter operates with a switching frequency of 1.85MHz when drives 80mA load current. As the converter drives over 170mA load current, the switching frequency is fixed on 2MHz. The converter has output ripple voltage of less 20mV and more than efficiency 85% with 50~500mA laod current condition.

The Design of DC-DC Converter with Green-Power Switch and DT-CMOS Error Amplifier (Green-Power 스위치와 DT-CMOS Error Amplifier를 이용한 DC-DC Converter 설계)

  • Koo, Yong-Seo;Yang, Yil-Suk;Kwak, Jae-Chang
    • Journal of IKEEE
    • /
    • v.14 no.2
    • /
    • pp.90-97
    • /
    • 2010
  • The high efficiency power management IC(PMIC) with DTMOS(Dynamic Threshold voltage MOSFET) switching device and DTMOS Error Amplifier is presented in this paper. PMIC is controlled with PWM control method in order to have high power efficiency at high current level. Dynamic Threshold voltage CMOS(DT-CMOS) with low on-resistance is designed to decrease conduction loss. The control parts in Buck converter, that is, PWM control circuits consist of a saw-tooth generator, a band-gap reference circuit, an DT-CMOS error amplifier and a comparator circuit as a block. the proposed DT-CMOS Error Amplifier has 72dB DC gain and 83.5deg phase margin. also Error Amplifier that use DTMOS more than CMOS showed power consumption decrease of about 30%. DC-DC converter, based on Voltage-mode PWM control circuits and low on-resistance switching device is achieved the high efficiency near 96% at 100mA output current. And DC-DC converter is designed with Low Drop Out regulator(LDO regulator) in stand-by mode which fewer than 1mA for high efficiency.