• Title/Summary/Keyword: 골 고정원

Search Result 88, Processing Time 0.026 seconds

Three dimensional finite element method for stress distribution on the length and diameter of orthodontic miniscrew and cortical bone thickness (교정용 미니스크류 식립 시 스크류의 길이, 직경 및 피질골 두께에 따른 응력 분포에 관한 3차원 유한요소법적 연구)

  • Lim, Jong-Won;Kim, Wang-Sik;Kim, Il-Kyu;Son, Choong-Yul;Byun, Hyo-In
    • The korean journal of orthodontics
    • /
    • v.33 no.1 s.96
    • /
    • pp.11-20
    • /
    • 2003
  • The purpose of the present study is to evaluate the stress distribution on the length and diameter of the miniscrew and cortical bone width. Three dimensional finite element models were made of diameter 1.2mm, 1.6mm, 2.0mm and length 6.0mm, 8.0mm, 10.0mm, 12.0mm and cortical bone width 1.0mm. Also, another three dimensional finite element models were made of diameter 1.2mm, 1.6mm, 2.0mm and length 8.0mm and cortical bone width 1.0mm, 1.5mm, 2.0mm, 2.5mm. Two-hundred grams horizontal force were applied on the center of the miniscrew head and at that stress distribution and its magnitude had been analyzed by ANSYS, which is three dimensional finite element analysis program. The obtained results were as follows : 1. The comparison of the maximum von-Mises stress in the miniscrew showed that as the diameter increases from 1.2mm to 2.0mm stress has been decreased, while on the same diameter stress was not changed regardless of the length change. 2. The comparison of the maximum von-Mises stress in the cortical and cancellous bone showed that as the diameter increases from 1.2mm to 2.0mm stress has been decreased, while on the same diameter stress was not changed regardless of the length change. 3. In the analysis of the stress distribution in the cortical and cancellous bone, the most of the stress had been absorbed in the cortical bone, and did not transmitted much to the cancellous bone. 4. In the analysis of the maximum von-Mises stress according to the cortical bone width, the same diameter of the miniscrew showed a constant stress value regardless of the cortical bone width change. The above results suggest that the maintenance of the miniscrew is more reliable on diameter than length of the miniscrew.

Use of corticotomy for canine and molar retraction (피질골 절제술을 응용한 견치 및 대구치의 후방 견인)

  • Kim, Sang-Cheol;Kim, Sun-Young;Kim, Hyun-Sook;Jung, Hye-Seung;Kim, Hyun-Tae;Jo, Jin-Woo
    • The korean journal of orthodontics
    • /
    • v.35 no.2 s.109
    • /
    • pp.153-161
    • /
    • 2005
  • Tooth movement facilitated by corticotomy and distraction osteoseresis was discussed. In this study, a portion of cortical bone which can provide resistance to tooth movement in alveolar bone was removed Active bone deposition was thor Possible in the tension side. Teeth moved at such a speedy rate as we could not imagine from conventional orthodontic treatment. which lead to the reduction of the total treatment Period Posterior movement of the canine or molar teeth was possible without any side effects such as anchorage loss, root resorption or Periodontal breakdown.

Closed Interlocking Intrmedullary Nailing of Metastatic Diaphyseal Fractures of the Humerus (상완골 간부 악성 병적골절의 비관혈적 고합성 골수강내 금속정 고정술)

  • Bahk, Won-Jong;Rhee, Seung-Koo;Kang, Yong-Koo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.9 no.1
    • /
    • pp.1-11
    • /
    • 2003
  • Purpose: To analysis of the result of the treatment of metastatic diaphyseal fracture of the humerus with closed interlocking intrameduallry nailing. Materials and Methods: Among surgically treated 29 patients with pathologic or impending fracture of diaphysis of the humeurs, 13 patients (16 cases) treated with closed intramedullary interlocking nail were selected for the study. The final result of pain relief and functional recovery was evaluated by modified rating system of Perez et al. Results: Primary cancer was diagnosed after fracture was developed in 2 patients and pathologic or impending fracture was occurred average period of 28.9 months after primary cancer was diagnosed. The main primary malignancies were multiple myeloma, lung cancer and breast cancer. Mean survival after humeral metastasis was 11.7 months. The final result was superior to fair in 13 of 16 cases, and poor in 3 cases with progression of tumor spread or distant dissemination to the ipsilateral fingers. Except the latter 3 patients and other 3 patients, who died before 3 months postoperatively, bony union was achieved in 10 cases. There were no complications related to surgery. Conclusion: Closed interlocking intrameduallry nailing is accomplished with brief operative time, small amount of bleeding and provides immediate stability with resultant early return of function to the arm. Additionally it allows early postoperative irradiation. However, some of our cases shows that intramedullary nailing can accelerate tumor spread and metastases elsewhere, so that serious consideration must be given in planning this treatment. In conclusion, the functional status before fracture, life expectancy, type of tumor and extent of involvement should be carefully considered to decide operative treatment of metastatic disease.

  • PDF

Three dimensional analysis of tooth movement using different types of maxillary molar distalization appliances (간접골성 고정원을 이용한 상악 구치부 원심이동 장치 종류에 따른 치아 이동 양상 평가)

  • Kim, Su-Jin;Chun, Youn-Sic;Jung, Sang-Hyuk;Park, Sun-Hyung
    • The korean journal of orthodontics
    • /
    • v.38 no.6
    • /
    • pp.376-387
    • /
    • 2008
  • Objective: The purpose of this study was to compare the three dimensional changes of tooth movement using four different types of maxillary molar distalization appliances; pendulum appliance (PD), mini-implant supported pendulum appliance (MPD), stainless steel open coil spring (SP) and mini-implant supported stainless steel open coil spring (MSP). Methods: These experiments were performed using the Calorific $machine^{(R)}$ which can simulate dynamic tooth movement. Computed tomography (CT) images of the experimental model were taken before and after tooth movement in 1 mm thicknesses and reconstructed into a three dimensional model using V-works $4.0^{TM}$. These reconstructed images were superimposed using Rapidform $2004^{TM}$ and the direction and amount of tooth movement were measured. Results: The mean reciprocal anchor loss ratio at the first premolar was 17 - 19% for the PD and SP groups. The appliances using mini-implants (MPD or MSP) resulted in less anchorage loss (7 - 8%). On application of a pendulum appliance or MPD, distalization was obtained by tipping rather than by bodily movement. Furthermore, the maxillary second molar tipped distally and bucally. But on application of MSP, distalization was achieved almost by bodily movement. Conclusions: Regarding tooth movement patterns during molar distalization, stainless steel open coil spring with indirect skeletal anchorage was relatively superior to other methods.

MAXILLARY ADVANCEMENT USING RIGID EXTERNAL DISTRACTION(RED) IN CLEFT LIP AND PALATE PATIENT : CASE REPORT (견고 구외 골신장술을 이용한 구순구개열 환아의 치험례)

  • Yu, Nan-Young;Kim, Sung-Min;Lee, Ju-Hyun;Seo, Hyun-Woo;Park, Ho-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.4
    • /
    • pp.709-716
    • /
    • 2005
  • Patients with cleft tip and palate present severe maxillary hypoplasia due to scar of lip and palate, often accompanied by compromised mastication, speech abnormalities. Sometimes maxillary hypoplasia persist even though active orthodontic treatment was done. In theses cases, patients born with cleft lip and palate will be potential candidates for maxillary advancement with bone grafting after growth to correct the functional deformities and improve aesthetic facial proportions. But, maxillary advancement using standard surgical approaches has several limitations : increased relapse tendency after maxillary advancement, necessity of additional bone graft and mandibular setback surgery. Distraction osteogenesis is current treatment modality to overcome these limitations, thus has become popular for treatment of maxillary hypoplasia associated cleft lip and palate, craniosyntosis. Especially, rigid external distraction, contrary to internal device, has advantages : better vector control of osteotomized segment, effective traction of the bony segments, the ease of the application and removal the distraction device. This study showed that relatively successful result could be generated by using rigid external distraction osteogenesis(RED) in the case of cleft lip and palate with severe maxillary hypoplasia, 6 years 7 months old.

  • PDF

Early histological change in hard tissue from orthodontic force placed on microscrews in ovariectomized rats (난소 적출 백서에 식립된 마이크로스크류에 교정력 부여 시 나타난 초기 경조직 변화에 관한 연구)

  • Lee, Dea-Seung;Chang, Moon-Jung;Lee, Jin-Woo
    • The korean journal of orthodontics
    • /
    • v.36 no.2 s.115
    • /
    • pp.103-113
    • /
    • 2006
  • Most elderly women experience a decrease in their bone density due to a deficiency of calcium intake, ovariectomy, or menopause. This study evaluated the usability of the microscrew as a skeletal anchorage system in these orthodontic treatment cases, using rats as a research group. The 4 month old sprague-dawley species rats were divided into two groups, the OS (Ovariectomy Screw), and the SS (Sham operation Screw) group. In both the OS and SS groups, microscrews were implanted into the palatal bone between the upper molar teeth and two upper incisors were retracted using NETE coil spring with 75 g of force. After 3days, the again after 7 days, 7 rats in each group were sacrificed. Three days before they were sacrificed, Alizarin red S was intraperitoneally injected, and their maxillary bone, tibia and blood from their hearts were taken. The components of the extracted blood were biochemically analyzed and non-decalcified grinding resin sections for maxillary bone and tibia were made. The sections were examined with a polarization microscope, and fluorescent microscope. Smaller concentrations of Ca and P, the inorganic substances closely related to bone density, were found in the extracted blood of the OS group. Both OS and SS groups showed a possibility of bone remodeling with a high concentration of ALP after 7 days. An increase in bone density on the tension and compression sides of the microscrew and the tension side of the tooth for both OS and SS groups was confirmed with a polarization microscope. However, the bone density of the pressure side of the tooth and apical side was decreased. More deposits of Alizarin red S in the bone after 7 days rather than 3 days seen with a fluorescent microscope suggested the existence of new bone formation.

Three-dimensional finite element analysis according to the insertion depth of an immediately loaded implant in the anterior maxilla (상악 전치부 즉시하중 임플란트의 식립 깊이에 따른 삼차원 유한요소 분석)

  • Park, Cheol-Woo;Kim, Sung-Hun;Yeo, In-Sung;Yoon, Hyung-In;Han, Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.105-113
    • /
    • 2018
  • Purpose: The purpose of this study was to investigate the effects of the insertion depth of an immediately loaded implant on the stress distribution of the surrounding bone and the micromovement of the implant using the three-dimensional finite element analysis. Materials and methods: A total of five bone models were constructed such that the implant platform was positioned at the levels of 0.00 mm, 0.25 mm, 0.50 mm, 0.75 mm, and 1.00 mm depth from the crest of the cortical bone. A frictional coefficient of 0.3 and the insertion torque of 35 Ncm were simulated on the interface between the implant and surrounding bone. A static load of 178 N was applied to the provisional prosthesis with a vertical load in the axial direction and an oblique load at $30^{\circ}$ with respect to the central axis of the implant, then a finite element analysis was performed. Results: The implant insertion depth significantly affected the stress distribution on the surrounding bone. The largest micromovement value of the implant was $39.34{\mu}m$. The oblique load contributed significantly to the stress distribution and micromovement in comparison to the vertical load. Conclusion: Increasing the implant insertion depth was advantageous in dispersing the concentrated stress in the cortical bone and did not significantly affect the micromovement associated with early osseointegration failure.

ORTHODONTIC TREATMENT OF AN IMPACTED MANDIBULAR FIRST MOLAR USING MINIPLATE AS A SKELETAL ANCHORAGE: A CASE REPORT (Miniplate를 골격성 고정원으로 이용한 매복된 하악 제1대구치의 교정치료 증례)

  • Jang, Yoon-Hyoung;Kim, Eun-Young;Kim, Kwang-Chul;Park, Jae-Hong;Lee, Baek-Soo;Choi, Sung-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.2
    • /
    • pp.246-251
    • /
    • 2010
  • Impactions can occur because of malpositioning of the tooth bud or obstruction in the path of eruption. However, the exact mechanism is still unknown. The impaction of mandibular first molar is rare with prevalence rates of 0.01~0.25%, but it is important to deimpact the tooth as soon as possible to avoid complications such as dental caries, root resorption, and periodontal problems on the adjacent teeth. Several biomechanical strategies have been proposed for uprighting mesially tipped mandibular first molars. However, most of these have had problems with movement of the anchorage unit because of the reciprocal force. The recent development of skeletal anchorage system(SAS) allows direct application of precise force systems to the target tooth or segment, producing efficient tooth movement in a short time. In this case, an impacted mandibular left first molar with dilacerated roots was treated with a miniplate, which provided skeletal anchorage to upright the tooth. The miniplate was installed in the mandibular ramus, and 10 months after the application of orthodontic force, the impacted tooth was exposed in the oral cavity and uprighted. At this point, the mandibular left first molar was included in the orthodontic appliance with fixed mechanotherapy, the tooth could achieve a normal occlusion. Therefore, the use of SAS simplified the orthodontic procedures and reduced the orthodontic treatment period, and had few side effects.

Histological Periodontal Tissue Reaction to Rapid Tooth Movement by periodontal Distraction in Dogs (치주인대 신장에 의한 치아의 급속 견인 시 성견 치주조직의 변화)

  • Chang, Young-Il;Kim, Tae-Woo;Choi, Hee-Young
    • The korean journal of orthodontics
    • /
    • v.32 no.6 s.95
    • /
    • pp.455-466
    • /
    • 2002
  • The objective of this study was to evaluate the changes that occurred over time in the distracted periodontal ligament space following the rapid retraction of a tooth by periodontal distraction after bone undermining surgery had been conducted in the dogs. The upper second premolars were extracted on the left and right side in 4 male beagle dogs. Immediately after extraction, the interseptal bone distal to the upper first premolar was thinned and undermined by grooving to decrease the bone resistance. Activating an individualized distraction appliance at the rate of 0.225mm twice a day, the upper first premolar was retracted rapidly toward the extraction socket. Periodontal distractions were performed for 5, 10, and 20 days, and 20-day-distraction cases were followed by maintenance periods of 0, 14, 28, and 56 days. After 20 days of rapid retraction, the average distal movement of the upper first premolar was 5.02mm, and the average mesial movement of the upper third premolars serving as an anchorage unit was 0.18 mm. On histological examination, the regeneration of bone occurred in a highly organized pattern. Distracted periodontal ligament space was filled with newly formed bone oriented in the direction of the distraction, and this was followed by extensive bone remodeling. This result was similar to those observed in other bones after distraction osteogenesis. In the periodontal ligament, the relationship between collagen fibers and cementum began to be restored 2 weeks after the distraction was completed, and showed almost normal features 8weeks after the completion of the periodontal distraction. However, on the alveolar side, the new bone formation was still in process and collagen fiber bundles and Sharpey's fibers were not present 8 weeks after the completion of the periodontal distraction. Reactions in the periodontal ligament of the anchorage tooth represented bone resorption on the compressed side and new bone deposition on the tension side as occurred in conventional orthodontic tooth movement. In conclusion, the results of this study showed that periodontal structures on the distracted side of the periodontal ligament were regenerated well histologically following rapid tooth movement.

Giant cell tumor of Cuneiform - A Case Report - (족부 설상골에 발생한 거대세포종 - 증례보고 1례 -)

  • Kim, Jin-Won;Park, Hong-Gi;Cho, Hyun-I
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.8 no.2
    • /
    • pp.58-62
    • /
    • 2002
  • The incidence of giant cell tumors represents only 5% to 10% of all bone tumors. Occurrence on the small bones of the hand and foot are very rare. They typically present with pain and sometimes a pathologic fracture or even soft tissue extension. The radiographic appearance is highly characteristic. An eccentric osteolytic lesion is seen, producing cortical thinning and expansion, and possessing a delicate trabecular pattern. In tarsal bones, poorly or well-defined osteolytic lesions of variable size are encountered. Surgical treatment remains the preferred therapy. Marginal or wide en bloc resection has had far better results in term of local recurrence. Several authors have suggested extended curettage and cement as an alternative to en bloc resection. Follow-up is necessary to monitor for both local recurrence and the infrequent pulmonary metastases.

  • PDF