• Title/Summary/Keyword: 건축면적

Search Result 515, Processing Time 0.03 seconds

Numerical Analysis on Flow Characteristics in the Pressurized Air Supply Smoke Control System (급기가압 제연설비의 내부 유동특성에 대한 수치해석)

  • Ko, Gwon-Hyun
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.52-58
    • /
    • 2017
  • This study investigated the pressure difference distribution and the flow characteristics among room, ancillary room, and stair case by carrying out the numerical simulations on the air flow inside the pressurized air supply smoke control system. Numerical simulations were conducted to analyze pressure and velocity distribution of compartments by pressurized air supply for the air-leakage test facility which was built to measure the effective leakage area. In this study, the leakage of air was considered by locating the narrow slit onto fire door and window of room. Simulated results using this method precisely followed the previous experimental results for the pressure differences between the stair case and ancillary room. Predicted results showed that the local leakage of air rarely affected the overall flow pattern and pressure distribution. Although the average velocity over the door between room and ancillary room satisfied the regulation for fire safety, it was certified the unsafe outflow to ancillary room could be occurred in the local position such as the upper part of the door.

Experimental Study on the Setting Time and Compressive Strength of Nano-Micro Pozzolanic Binders as Cement Composites (포졸란 혼화재의 입자 크기 및 비표면적에 따른 응결시간 발현 및 압축강도 특성 평가)

  • Kim, Won-Woo;Yang, Keun-Hyeok
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.3
    • /
    • pp.269-275
    • /
    • 2022
  • In this study, the setting time and compressive strength of cement paste composites applied with nano-micro pozzolanic binders were experimental analyzed. The pozzolanic binder was reduced initial and final setting time and the compressive strength was increased. Micro silica was effective in decrease the initial setting and final setting time and impressing the compressive strength. When two or more cement binders were used, the using of silica fume and a small amount of nano silica at reduced the setting time to 62-64 % to OPC cement and the compressive strength was increased to 117 %. A small amount of mixing the nano silica was effect to pore filling and pozzolanic activation. However, the addition of a chemical admixture should be considered when mixing table design because pozzolanic binders high specific surface area causes a decrease in cement composites flow.

Analysis on the Effects of Flood Damage Mitigation according to Installation of Underground Storage Facility (지하저류조 설치에 따른 침수피해 저감효과 분석)

  • Kim, Young Joo;Han, Kun Yeun;Cho, Wan Hee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.1B
    • /
    • pp.41-51
    • /
    • 2010
  • In this study, runoff simulation was carried out in the area of Bisan 7-dong, Seo-gu, Daegu as drainage basin and the effects of the installation of underground storage facilities were analyzed during heavy rainfall. SWMM model was used for the runoff and pipe network analysis on Typhoon Maemi, 2003. 2-D inundation analysis model based on diffusion wave was employed for inundation analysis and to verify computed inundation areas with observed inundation trace map. The simulation results agree with observed in terms of inundation area and depth. Also, the effects of flood damage mitigation were analyzed through the overflow discharge and 2-D inundation analysis, depending upon whether the underground storage facility is installed or not. When the underground storage facility ($W:120m{\times}L:180m{\times}H:1.7m$) is installed, volume of overflow could be reduced by 72% and flooding area could be reduced by 40.1%. When the underground storage facility ($W:120m{\times}L:180 m{\times}H:2.0m$) is installed, volume of overflow could be reduced by 84.8% and flooding area could be reduced by 50.6%. When the underground storage facility ($W:120m{\times}L:180m{\times}H:2.2m$) is installed, volume of overflow could be reduced by 94% and flooding area could be reduced by 91.2%. There is no overflow of manhole, when the height of storage facility is 2.5 m. It is expected that the study results presented through quantitative analysis on the effects of underground facilities can be used as base data for socially and economically effective installation of underground facilities to prevent flood damage.

A History of Termite Control and Improvements to Prevent Termites in Wooden Architectural Heritage (국내외 흰개미 방제 기술의 발달 과정과 목조건축문화재의 흰개미 피해 저감을 위한 방안)

  • LEE, Sangbin;IM, Ikgyun;KIM, Sihyun
    • Korean Journal of Heritage: History & Science
    • /
    • v.54 no.2
    • /
    • pp.194-215
    • /
    • 2021
  • Termites are important decomposers in the ecosystem. They are also economically significant structural pests. In this study, we reviewed the developments of termite control and recent research on termite management to provide information on the prevention and control of termites. In Korea, most of the damage to wooden historical buildings is caused by subterranean termites. Reticulitermes speratus kyushuensis is the main species, which is widely found throughout the country. In the early 1900s, inorganic insecticides, such as arsenic dust, were used for termite control. After the synthesis of chlorinated hydrocarbon pesticide in the 1940s, it was widely utilized and demonstrated high termite control efficacy. However, chlorinated hydrocarbon insecticides were later banned, disappearing from markets after reports emerged concerning environmental contamination and toxicity to humans. Therefore, the termite control industry sought a new termiticide; hence many pesticides were utilized for termite control. Organophosphate (1960s), carbamate (1970s), pyrethroid, and insect growth inhibitor (1980s) were newly synthesized and adopted. In the 1990s, the first commercial baits using chitin synthesis inhibitors (CSI) were developed, providing a means to eliminate an entire colony of subterranean termites around a structure. Many studies have been carried out on soil termiticides (liquid termiticides) and CSI baits to increase their efficacy, and different baits such as aboveground bait stations, fluid bait, and high-durability bait were also developed in the 2000s. In addition, the paradigm of termite control has shifted from localized treatments using soil termiticides to area-wide pest management using CSI baits to create termite-free zones and protect buildings over time. Termite infestations in wooden historical buildings in Korea have been reported since 1980, and considerable attention was drawn in the 1990s when several UNESCO world heritages such as the Jongmyo Shrine and the Janggyeong Panjeon Depositories of Haeinsa Temple were infested by subterranean termites. Since then, a survey of termite infestation in wooden architectural heritage has been conducted, and the National Research Institute of Cultural Heritage and Heritage Care Program regularly monitors those properties. Finally, we suggest termite management using primarily CSI baits, selective application of various soil treatments applied to the object, foundation soil treatment, research and development of durable termite baits, application of area-wide programs for wooden-building complexes, application of integrated termite management (ITM), and regular education for owners and managers to prevent and reduce termite damage.

Ways of Improving the Method of the Apportionment of Alloted Resident Tax on Corporation Tax (법인세할 주민세 안분방법의 개선안)

  • Park, Sang-Bong;Yu, Soon-Mi
    • Management & Information Systems Review
    • /
    • v.30 no.1
    • /
    • pp.71-86
    • /
    • 2011
  • The existing tax law provides that alloted resident tax on corporation tax is apportioned in accordance with the number of employees and total building area as of the end of business year. Through a case analysis, however, this study found that such apportionment is not applied to businesses whose operation was already withdrawn as of the end of business year. To solve this problem, the study proposed that the apportionment of alloted resident tax on corporation tax should be made in accordance with the number of employees and total building area in the middle of business year and a standard of corporation tax assessment, that is, sales assessed according to the value-added tax law. This proposal already proved to be reasonable by lots of actual cases that showed the realization of balance in taxation. To make more precise standards of the above mentioned apportionment, then, the study proposed that in the ordinance of the local tax law, 'as of the end of business year' should be replaced by 'in the middle of business year'. In addition, 'in the middle of business year' should be defined as 'in the period of continuous business' from the date of business end in the previous year to the date of business end in the present year and the length of the period should be calculated by month. These moves would bring more transparent and balanced local tax assignment than present under the local tax law.

  • PDF

Research on Basic Investigation and Analysis for Iand Substitution Planing using High-resolution Satellite Imagery (환지계획 수립시 고해상 위성영상을 이용한 기초조사 및 분석에 관한 연구)

  • Choi, Seung Pil;Jeong, Cheol Ju;Yeu, Yeon
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.21 no.2
    • /
    • pp.3-9
    • /
    • 2013
  • Various data like digital maps(1/1,000 or 1/5,000), field surveying, online materials and literatures are used for the preliminary investigation for urban development such as the feasibility evaluation, the profitability analysis, the zoning proposal, the zoning designation, and the land replotting planning. There are a couple of urban development methods like an expropriation, a replotting, a mixed-used method. The replotting method requires the consideration of land replotting types based on topography and building condition, which is not easy to gather data for the preliminary investigation maintaining the security of development planning. There are limitations of a preliminary investigation using aerial photos to detect topographic and building changes at specific period. GIS data combined with high-resolution imagery has advantages over the current dataset, which come from easy acquisition of various spatial resolution satellite images, wide swath coverage, the choice of imagery resolution satisfying a usage purpose, economic benefit comparing to aerial photos, and the calculation of distance and area on imagery from image modeling. For these reasons, the proposed method in this study enables to perform the more appropriate preliminary investigation using more accurate information.

A Study on the Eco-Service Values by Landuse Changes in Musan and Hoeryeung, North Korea (북한 무산시와 회령시의 토지이용 변화에 따른 생태서비스 가치 연구)

  • Lee, Min-Boo;Kim, Nam-Sin;Jin, Shi-Zhu;Kim, Ae-Bun;Zhu, Zhe
    • Journal of the Korean association of regional geographers
    • /
    • v.17 no.4
    • /
    • pp.493-504
    • /
    • 2011
  • Based on 3-period land use data using RS and GIS, this paper analyzed landuse change and subsequent loss of ecosystem service value, using the ecosystem service value coefficients put forward by Costanza. Results show that from 1917 to 2006, area of crop land, plantation, building site, unused land increased and natural forest, grassland, water area, wetland decreased, in Musan region and Hoeryeung region. But the area of natural forest is acute reduced by 7,925.34ha and the amplitude of building site is increased rapidly in Musan region. The area of grass land is acute reduced by 71,594.34ha and the amplitude of unused land is increased rapidly in Hoeryeung region. Total ecosystem services value of Musan region reduced dramatically, from $66,135.26{\times}10^6$ won to $37,894.51{\times}10^6$ won in period 1917~2006. The net decreased ecosystem services value is $28,240.75{\times}10^6$ won and the increased amplitude is 42.71% in Musan region. Total ecosystem services value of Hoeryeung region reduced dramatically, from $145,862.69{\times}10^6$ won to $106,948.44{\times}10^6$ won in period 1917~2006. The net decreased ecosystem services value is $38,914.25{\times}10^6$ won and the increased amplitude is 26.68% in Hoeryeung region. Therefore, the effective measures should be taken to maintain sustainable development of environment.

  • PDF

Review of Assessment Criteria for Sustainable Outdoor Space Responding to Climate Change (기후위기 대응 외부공간의 지속가능성 평가지표의 검토 및 고찰)

  • Chun, Seung-Hoon;Chae, Soo-Kwon
    • Journal of Environmental Impact Assessment
    • /
    • v.30 no.6
    • /
    • pp.393-412
    • /
    • 2021
  • This study examines the assessment systems of LEED v4.1, an eco-friendly building evaluation system in the United States, and SITE v2, an assessment system for sustainable outdoor spaces, and then compares and examines them from the perspective ofrelevant laws and institutional guidelines and standards in Korea. The conclusion is as follows. First, the US eco-friendly certification system basically not only establishes an independent evaluation system according to the field of expertise, but also provides a sustainable city and community through response to the climate crisis and the comfort of the external space environment. It can be evaluated that securing the quality of life of healthy and happy city dwellers is the top priority. Second, Korea's Green Building Certification System (G-LEED) was basically based on the American LEED system, but it was judged that there was a fundamental difference. It was judged that there is a limitation in not being able to achieve an integrated approach through the participation of various expert groups and stakeholders, but also in the accumulation of more scientific and reliable data and information through the application of cutting-edge information and communication equipment. Third, in the case of external space in Korea, a sustainable assessment system has not been established, and not only is it dispersed in various legal and institutional guidelines, but also its effectiveness is judged to be very low. Therefore, it is judged that it is urgent to introduce and secure the applicability of SITES v2, a sustainable outdoor space assessment system in the United States. It was judged that the effectiveness should be secured through the upward adjustment of the minimum Ecological Area Ratio.

Calculation of Appropriate Number of Parking Lots for Cultural and Assembly Facilities - Focused on the Gwangju Metropolitan City Movie Theater - (문화 및 집회시설 적정 주차면 수 산정에 관한 연구 - 광주광역시 영화관을 중심으로 -)

  • Jin, Tae-Hee;Kwon, Sung-Dae;Jin, Il;Ha, Tae-Jun;Lee, Hyung-Mu;Lee, Gang-Seok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.551-557
    • /
    • 2021
  • Attached parking lots installation criteria is determined by use, total floor area, etc. according to the Parking Lot Act and local government ordinances. However, with traffic demand increase inconvenience about use of culture and assembly facilities have been raised. When planning number of parking lots for cultural and assembly facilities, legal parking lots and unit parking lots are used, but this causes inconvenience and traffic problems on the surrounding roads, because reality and convenience are not considered. Therefore, this study intend to present an realistic number of parking lots calculating equation for movie theater in Gwangju Metropolitan City. After investigating number of parking lots, number of screens, number of seats, total floor area, bus route and illegal parking for a cultural facility in Gwangju Metropolitan City, prediction model for calculating number of parking lots was presented using SPSS regression analysis. As a result of comparing prediction model and unit method, the prediction model was be closer actual cumulative parking space, so prediction model verification was completed. Based on the model verified in this study, Realistic number of parking lots will be installed. However, due to limitations of research on specific areas, research on various facilities should continue in consideration of regional, population, and urban characteristics

A Research of the suitable Area and Module in Elementary School Classroom - Focusing on Elementary Schools of Northern Province of Gyeonggi-do - (초등학교 일반교실의 필요 면적과 모듈에 관한 연구 - 경기북부지역 초등학교를 중심으로-)

  • Yoon, Hee-Cheol
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.20 no.3
    • /
    • pp.1-10
    • /
    • 2021
  • Before long the number of Elementary School students per class will be 20 in Korea, but the current Area and Module of Elementary School are planned for 30 students. Therefore, necessary Area and Module for less than 20 students should be prepared. The purpose of this research is to find out necessary Area and Module for less than 20 students in Elementary School Classroom. I researched 60 Classrooms of 10 Elementary Schools before 2 researches of mine, and researched the sizes of every path in the classrooms. With the Plans for 20 students, I found the conclusion as follows: First, the one-way class requires a minimum of 5.4m×8.1m (43.74m2), a maximum of 5.4m×8.7m (48.6m2). Second, the 3-row alignment class requires a minimum of 7.2m×7.2m (51.84m2), a maximum of 7.5m×7.5m (56.25m2). Third, the group study class requires a minimum of 6.0m×8.7m (52.2m2), a maximum of 6.3m×9.3m (58.59m2). Fourth, the group study class requires a minimum of 2.34m2, a maximum of 14.85m2 more than the one-way class. Fifth, the suitable module which fits both 2-row alignment class and group study class except the 3-row alignment class is 6.0m×8.7m (52.2m2).