• Title/Summary/Keyword: $F_0$ change

Search Result 937, Processing Time 0.042 seconds

Pressure Distribution in Stump/Socket Interface in Response to Socket Flexion Angle Changes in Trans-Tibial Prostheses With Silicone Liner

  • Kang, Pil;Kim, Jang-Hwan;Roh, Jung-Suk
    • Physical Therapy Korea
    • /
    • v.13 no.4
    • /
    • pp.71-78
    • /
    • 2006
  • This study examined the effects of socket flexion angle in trans-tibial prosthesis on stump/socket interface pressure. Ten trans-tibial amputees voluntarily participated in this study. F-socket system was used to measure static and dynamic pressure in stump/socket interface. The pressure was measured at anterior area (proximal, middle, and distal) and posterior area (proximal, middle, and distal) in different socket flexion angles ($5^{\circ}$, $0^{\circ}$, and $10^{\circ}$). Paired t-test was used to compare pressure differences in conventional socket flexion angle of $5^{\circ}$ with pressures in socket flexion angles of $0^{\circ}$ and $10^{\circ}$ (${\alpha}$=.05). Mean pressure during standing in socket flexion angle of $10^{\circ}$ decreased significantly in anterior middle area (19.7%), posterior proximal area (10.4%), and posterior distal area (16.3%) compared with socket flexion angle of $5^{\circ}$. Mean pressure during stance phase in socket flexion angle of $0^{\circ}$ increased significantly in anterior proximal area (19.3%) and decreased significantly in anterior distal area (19.7%) compared with socket flexion angle of $5^{\circ}$. Mean pressure during stance phase in socket flexion angle of $10^{\circ}$ decreased significantly in anterior proximal area (19.6%) and increased significantly in anterior distal area (8.2%) compared with socket flexion angle of $5^{\circ}$. Peak pressure during gait in socket flexion angle of $0^{\circ}$ increased significantly in anterior proximal area (23.0%) compared with socket flexion angle of $5^{\circ}$ and peak pressure during gait in socket flexion angle of $10^{\circ}$ decreased significantly in anterior proximal area (22.7%) compared with socket flexion angle of $5^{\circ}$. Mean pressure over 80% of peak pressure ($MP_{80+}$) during gait in socket flexion angle of $0^{\circ}$ increased significantly in anterior proximal area (23.9%) and decreased significantly in anterior distal area (22.5%) compared with socket flexion angle of $5^{\circ}$. $MP_{80+}$ during gait in socket flexion angle of $10^{\circ}$ decreased significantly in anterior distal area (34.1%) compared with socket flexion angle of $5^{\circ}$. Asymmetrical pressure change patterns in socket flexion angle of $0^{\circ}$ and $10^{\circ}$ were revealed in anterior proximal and distal region compared with socket flexion angle of $5^{\circ}$. To provide comfortable and safe socket for trans-tibial amputee, socket flexion angle must be considered.

  • PDF

Regulatory Mechanism of Vascular Contractility by Extracellular $\textrm{K}^{+}$: Effect on Endothelium-Dependent Relaxation and Vascular Smooth Muscle Contractility (세포 외 $\textrm{K}^{+}$의한 혈관 수축신 조절 기전: 혈관평활근 수축성과 내피세포 의존성 이완에 미치는 영향)

  • 유지영;설근희;서석효;안재호
    • Journal of Chest Surgery
    • /
    • v.37 no.3
    • /
    • pp.210-219
    • /
    • 2004
  • Extracellular $K^{+}$ concentration ([ $K^{+}$]$_{0}$ ) can be increased within several mM by the efflux of intracellular $K^{+}$. To investigate the effect of an increase in [ $K^{+}$]$_{0}$ on vascular contractility, we attempted to examine whether extracellular $K^{+}$ might modulate vascular contractility, endothelium-dependent relaxation (EDR) and intracellular $Ca^2$$^{+}$ concentration ([C $a^2$$^{+}$]$_{i}$ ) in endothelial cells (EC). We observed isometric contractions in rabbit carotid, superior mesenteric, basilar arteries and movse aorta. [C $a^2$$^{+}$]$_{i}$ was recorded by microfluorimeter using Fura-2/AM in EC. No change in contractility was recorded by the increase in [ $K^{+}$]$_{0}$ from 6 to 12 mM in conduit artery such as rabbit carotid artery. whereas resistant vessels, such as basilar and branches of superior mesenteric arteries (SMA), were relaxed by the increase. In basilar artery, the relaxation by the increase in [ $K^{+}$]$_{0}$ to from 1 to 3 mM was bigger than that by the increase from 6 to 12 mM. In contrast, in branches of SMA, the relaxation by the increase in [ $K^{+}$]$_{0}$ to from 6 to 12 mM is bigger than that by the increase from 1 to 3 mM. $Ba^2$$^{+}$ (30 $\mu$M) did not inhibit the relaxation by the increase in [ $K^{+}$]$_{0}$ from 1 to 3 mM but did inhibit the relaxation by the increase from 6 to 12 mM. In the mouse aorta without the endothelium or treated with $N^{G}$_nitro-L-arginine (30 $\mu$M), nitric oxide synthesis blocker, the increase in [ $K^{+}$]$_{0}$ from 6 to 12 mM did not change the magnitude of contraction induced either norepinephrine or prostaglandin $F_2$$_{\alpha}$. The increase in [ $K^{+}$]$_{0}$ up to 12 mM did not induce contraction of mouse aorta but the increase more than 12 mM induced contraction. In the mouse aorta, EDR was completely inhibited on increasing [ $K^{+}$]$_{0}$ from 6 to 12 mM. In cultured mouse aorta EC, [C $a^2$$^{+}$]$_{i}$ , was increased by acetylcholine or ATP application and the increased [C $a^2$$^{+}$]$_{i}$ , was reduced by the increase in [ $K^{+}$]$_{0}$ reversibly and concentration-dependently. In human umbilical vein EC, similar effect of extracellular $K^{+}$ was observed. Ouabain, a N $a^{+}$ - $K^{+}$ pump blocker, and N $i^2$$^{+}$, a N $a^{+}$ - $Ca^2$$^{+}$ exchanger blocker, reversed the inhibitory effect of extracellular $K^{+}$. In resistant arteries, the increase in [ $K^{+}$]$_{0}$ relaxes vascular smooth muscle and the underlying mechanisms differ according to the kinds of the arteries; $Ba^2$$^{+}$-insensitive mechanism in basilar artery and $Ba^2$$^{+}$ -sensitive one in branches of SMA. It also inhibits [C $a^2$$^{+}$]$_{i}$ , increase in EC and thereby EDR. The initial mechanism of the inhibition may be due to the activation of N $a^{+}$ - $K^{+}$pump. activation of N $a^{+}$ - $K^{+}$pump.p.p.p.

Thermal Water Level Change and Geochemistry in the Suanbo Area, Korea (수안보지역의 온천수위 변동과 수리지구화학에 관한 연구)

  • Yum, Byoung-Woo;Kim, Yongje
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.6 no.2
    • /
    • pp.59-65
    • /
    • 1999
  • Both the groundwater changes due to different pumping rates and the geochemistry of thermal waters in the Suanbo area are considered in this study. The observation of groundwater level change since 1991 shows that the change is directly correlated with pumping rates of thermal waters and reveals the retardation of ca. 5 weeks after pumping. The hydrogeological aquifer in the area is under reducing condition. The thermal waters are of Na-HCO$_3$ type. and are alkaline (pH=8.5∼8.7) with low TDS values (274∼284 mg/l) and high concentrations of Na (68∼72 mg/l). F (6.4∼8.9 mg/l), and HCO$_3$(136∼146 mg/l). Oxygen and hydrogen isotope ratios of thermal water indicate a meteoric water origin. The activities of Rn-222 and Ra-226 in both thermal water and local groundwater were determined to delineate possible geochemical controls on the Rn-222 and Ra-226. The Rn-222 concentrations are several orders of magnitude greater than the Ra-226 concentrations. The concentrations of Rn-222 range from 190 to 7.490 pCi/1 with an average of 2,522 pCil/l. and those of Ra-226 average 0.32 pCi/1 with the range from 0.25 to 0.42 pCi/1. The concentrations of Rn-222 and Ra-226 are inversely correlated with EC and alkalinity. The pH it positively correlated with Ra-226. The correlation between Rn-222 and Ra-226 is poor. Thermal waters in the study area are produced from highly fractured phyllite. The thermal water qualify. CSAMT (controled-source audiofrequency magnetotelluric) prospecting, and petrological evidences, however, indicate that the heat is possibly transmitted through deep normal faults reaching a deep granite batholith, and the phyllite acts only as a groundwater pathway.

  • PDF

Phytoplankton Community Change of Lake Paldang by Increasing $CO_2$ and Temperature during Spring Cold Water Season ($CO_2$와 수온 증가에 대한 봄철 저수온기 팔당호 식물플랑크톤군집 변화)

  • Lee, Ka-Ram;Sung, Eun-Ju;Park, Hye-Jin;Park, Chae-Hong;Park, Myung-Hwan;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.46 no.4
    • /
    • pp.588-595
    • /
    • 2013
  • This study investigated the influence of temperature and $CO_2$ increase on phytoplankton growth and community structure during cold water season (spring) in Lake Paldang, Korea. Four experimental treatments of temperature and $CO_2$ manipulation were prepared in the laboratory batch culture: (1) Control; ambient low temperature ($6{\pm}2^{\circ}C$) and low $CO_2$ (air level, $400mgL^{-1}$), (2) T1; low temperature and high $CO_2$ ($800mgL^{-1}$), (3) T2; high temperature ($20{\pm}2^{\circ}C$) and low $CO_2$, (4) T3; high temperature and high $CO_2$. Algal growth experiment was carried out for 10 days under the light intensity of $70{\mu}mol\;m^{-2}s^{-1}$ (L :D=24 : 0). The level of pH decreased in both T1 and T3, due to dissolution of added $CO_2$. The dominant phytoplankton species of ambient water, Cyclotella meneghiniana succeeded to Fragilaria capucina var. gracilis in high-temperature treatment groups (T2 and T3). Cyanobacteria were very rare at the beginning of the experiment, while Oscillatoria limnetica appeared in only high-temperature groups (T2 and T3) at $6{\sim}7^{th}$ day. $CO_2$ addition in ambient temperature (T1) induced the highest phytoplankton growth, and thereby producing the highest average cell density of $3.27{\pm}0.33\;10^4\;cells\;mL^{-1}$, followed by T2 ($2.65{\pm}0.26\;10^4\;cells\;mL^{-1}$), T3 ($2.09{\pm}0.16\;10^4\;cells\;mL^{-1}$), and Control ($1.86{\pm}0.13\;10^4\;cells\;mL^{-1}$) (F=7.167, p=0.000). In summary, temperature increase changed the phytoplankton community structure and $CO_2$ increase promoted the phytoplankton growth during the cold spring season in Lake Paldang, suggesting a potential effect of climate change on freshwater phytoplankton.

INFRARED THERMOGRAPHIC ANALYSIS OF TEMPERATURE RISE ON THE SURFACE OF BUCHANAN PLUGGER (적외선열화상장치를 이용한 Buchanan plugger 표면의 온도상승 분석)

  • Choi, Sung-A;Kim, Sun-Ho;Hwang, Yun-Chan;Youn, Chang;Oh, Byung-Ju;Choi, Bo-Young;Juhng, Woo-Nam;Jeong, Sun-Wa;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.4
    • /
    • pp.370-381
    • /
    • 2002
  • This study was performed to evaluate the temperature rise on various position of the Buchanan plugger, the peak temperature of plugger's type and the temperature change by its touching time of heat control spling. The heat carrier system 'System B' (Model 1005, Analytic Technologies, USA) and the Buchanan's plug-gers of F, FM, M and ML sizes are used for this study. The temperature was set to 20$0^{\circ}C$ which Dr. Buchanan's "continuous wave of condensation" technique recommended on digital display and the power level on it was set to 10. In order to apply heat on the Buchanan's pluggers, the heat control spring was touched for 1, 2, 3, 4 and 5 seconds respectively. The temperature rise on the surface of the pluggers were measured at 0.5 mm intervals from tip to 20 mm length of shank using the infrared thermography (Radiation Thermometer-IR Temper, NEC San-ei Instruments, Ltd, Japan) and TH31-702 Data capture software program (NEC San-ei Instruments, Ltd, Japan). Data were analyzed using a one way ANOVA followed by Duncan's multiple range test and linear regression test. The results as follows. 1. The position at which temperature peaked was approximately at 0.5 mm to 1.5 mm far from the tip of Buchanan's pluggers (p<0.001). The temperature was constantly decreased toward the shank from the tip of it (p<0.001). 2. When the pluggerss were heated over 5 seconds, the peak temperature by time of measurement revealed from 253.3$\pm$10.5$^{\circ}C$ to 192.1$\pm$3.3$^{\circ}C$ in a touch for 1 sec, from 218.6$\pm$5.$0^{\circ}C$ to 179.5$\pm$4.2$^{\circ}C$ in a touch for 2 sec, from 197.5$\pm$3.$0^{\circ}C$ to 167.5$\pm$3.7$^{\circ}C$ in a touch for 3 sec, from 183.7$\pm$2.5$^{\circ}C$ to 159.8$\pm$3.6$^{\circ}C$ in a touch for 4 sec and from 164.9$\pm$2.$0^{\circ}C$ to 158.4$\pm$1.8$^{\circ}C$ in a touch for 5 sec. A touch for 1 sec showed the highest peak temperature, followed by, in descending order, 2 sec, 3 sec, 4 sec. A touch for 5 sec showed the lowest peak temperature (p<0.001). 3. A each type of pluggers showed different peak temperatures. The peak temperature was the highest in F type and followed by, in descending order, M type, ML type. FM type revealed the lowest peak temperature (p<0.001). The results of this study indicated that pluggers are designed to concentrate heat at around its tip, its actual temperature does not correlate well with the temperature which Buchanan's "continuous wave of condensation" technique recommend, and finally a quick touch of heat control spring for 1sec reveals the highest temperature rise.

Effects of Experimental Warming on Physiological Responses of Four Deciduous Tree Species Seedlings (실외 실험적 온난화 처리에 따른 활엽수 4개 수종 묘목의생리적 반응)

  • An, Jiae;Han, Seung Hyun;Chang, Hanna;Park, Min Ji;Son, Yowhan
    • Journal of Korean Society of Forest Science
    • /
    • v.105 no.4
    • /
    • pp.510-516
    • /
    • 2016
  • This study was conducted to investigate the physiological responses of newly-germinated seedlings of Fraxinus rhynchophylla Hance, Zelkova serrata (Thunb.) Makino, Betula costata Trautv. and Quercus variabilis Blume to open-field experimental warming. The seedlings in the warmed plots were warmed with $2.7^{\circ}C$ higher air temperature than those in the control plots using infrared heaters since April, 2015. Physiological responses (stomatal conductance, transpiration rate, chlorophyll content and net photosynthetic rate) to experimental warming varied with the species and the time of the measurement. Stomatal conductance ($mmol{\cdot}m^{-2}{\cdot}s^{-1}$) tended to decrease for F. rhynchophylla (Control: $158.97{\pm}42.76$; Warmed: $42.07{\pm}8.24$), Z. serrata (Control: $170.53{\pm}27.22$; Warmed: $101.17{\pm}42.27$) and B. costata (Control: $249.93{\pm}47.39$; Warmed: $150.73{\pm}26.52$). Transpiration rate ($mmol{\cdot}m^{-2}{\cdot}s^{-1}$) also decreased for F. rhynchophylla (Control: $4.08{\pm}0.62$; Warmed: $1.74{\pm}0.39$), Z. serrata (Control: $4.32{\pm}0.44$; Warmed: $3.24{\pm}1.14$) and B. costata (Control: $6.21{\pm}0.38$; Warmed: $4.66{\pm}0.28$). However, warming exhibited only minimal effects on stomatal conductance and transpiration rate of Q. variabilis seedlings. Chlorophyll content increased by the warming treatment while the effect of warming was not significant on net photosynthetic rate, since the warming treatment had a weak influence for changing net photosynthetic rate.

The Relationship between Premenstrual Changes and Degree of Stress Perception (월경전기변화와 스트레스의 지각 정도간의 상관관계)

  • Kim, Hoe-Kyoung;Joe, Sook-Haeng;Sin, Dong-Kyun
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.7 no.1
    • /
    • pp.61-71
    • /
    • 1999
  • Objective : The purpose of this study was to assess the relationship between the premenstrual changes and stress perception in women with premenstrual changes($PMC^+$)(n=32) and those without premenstrual changes($PMC^-$)(n=62) by using prospective method. Method : The women who were older than 30 years of age and healthy were asked to complete a daily rating form based on DSM-IV diagnostic criteria for one menstrual cycle to assess the changes of psychological and physical symptoms across the menstrual cycle. They also completed 5-point likert scale to assess the perception of stress. Percent changes method was used to assess changes between follicular phase and luteal phase. Results : 1) No significant differences were found in demographic factors(age, education, marriage, employment) and risk factors(onset ages of menarche, regularities of premenstrual changes, duration of menstruation, cycle length, amount of menstruation, dysmenorrhea) between women with and without premenstrual changes. 2) There was a significant difference in mean luteal phase stress score between women with($1.92\pm0.63$) and without premenstrual changes($1.51\pm0.42$)(p<0.05). However no difference was found in mean follicular phase stress score between two groups($PMC^+$ : $1.67\pm0.43$, $PMC^-$ : $1.33\pm0.39$). 3) We divided women having premenstrual changes into two groups, higher stress group(stress score > 1.75(median)) and the lower stress group(stress score <1.75(median)). The higher stress group reported more luteal psychological symptoms than did the lower stress group(df=1, F=13.362, p<0.001). However, the groups did not differ in physical symptoms. Conclusion : In women with premenstrual changes, luteal stress score was higher than follicular stress score and this result suggested tha the perception of stress was related to psychological symptoms but not physical symptoms. These findings suggested that premenstrual change is associated with the stress level, and that it is important to manage the stress which is focused on the management of psychological symptom in the treamtment of prementrual syndrome.

  • PDF

Evaluation of Standardized Uptake Value and Metabolic Tumor Volume between Reconstructed data and Re-sliced data in PET Study (PET 검사 시 Reconstructed data와 Re-sliced data의 표준섭취계수와 Metabolic Tumor Volume의 비교 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.3-8
    • /
    • 2016
  • Purpose SUV is one of the parameters that assist diagnosis in origin, metastasis and staging of cancer. Specially, it is important to compare SUV before and after chemo or radiation therapy to find out effectiveness of treatment. Storing PET data which has no quantitative change is needed for SUV comparison. However, there is a possibility to loss the data in external hard drive or MINIpacs that are managed by department of nuclear medicine. The aim of this study is to evaluate SUV and metabolic tumor volume (MTV) among reconstructed data (R-D) in workstation, R-D and re-sliced data (S-D) in PACS. Materials and Methods Data of 20 patients (aged $60.5{\pm}8.3y$) underwent $^{18}F-FDG$ PET (Biograph truepoint 40, mCT 40, mCT 64, mMR, Siemens) study were analysed. $SUV_{max}$, $SUV_{peak}$ and MTV were measured in liver, aorta and tumor after sending R-D in workstation, R-D and S-D in PACS to syngo.via software. Results R-D of workstation and PACS showed the same value as mean $SUV_{max}$ in liver, aorta and tumor were $2.95{\pm}0.59$, $2.35{\pm}0.61$, $10.36{\pm}6.15$ and $SUV_{peak}$ were $2.70{\pm}0.51$, $2.07{\pm}0.43$, $7.67{\pm}3.73$(p>0.05) respectively. Mean $SUV_{max}$ of S-D in PACS were decreased by 5.18%, 7.22%, 12.11% and $SUV_{peak}$ 2.61%, 3.63%, 10.07%(p<0.05). Correlation between R-D and S-D were $SUV_{max}$ 0.99, 0.96, 0.99 and $SUV_{peak}$ 0.99, 0.99, 0.99. And 2SD in balnd-altman analysis were $SUV_{max}$ 0.125, 0.290, 1.864 and $SUV_{peak}$ 0.053, 0.103, 0.826. MTV of R-D in workstation and PACS show the same value as $14.21{\pm}12.72cm^3$(p>0.05). MTV in PACS was decreased by 0.12% compared to R-D(p>0.05). Correlation and 2SD between R-D and S-D were 0.99 and 2.243. Conclusion $SUV_{max}$, $SUV_{peak}$, MTV showed the same value in both of R-D in workstation and PACS. However, there was statistically difference in $SUV_{max}$, $SUV_{peak}$ of S-D compare to R-D despite of high correlation. It is possible to analyse reliable pre and post SUV if storing R-D in main hospital PACS system.

  • PDF

The Evaluation of SUV Variations According to the Errors of Entering Parameters in the PET-CT Examinations (PET/CT 검사에서 매개변수 입력오류에 따른 표준섭취계수 평가)

  • Kim, Jia;Hong, Gun Chul;Lee, Hyeok;Choi, Seong Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.43-48
    • /
    • 2014
  • Purpose: In the PET/CT images, The SUV (standardized uptake value) enables the quantitative assessment according to the biological changes of organs as the index of distinction whether lesion is malignant or not. Therefore, It is too important to enter parameters correctly that affect to the SUV. The purpose of this study is to evaluate an allowable error range of SUV as measuring the difference of results according to input errors of Activity, Weight, uptake Time among the parameters. Materials and Methods: Three inserts, Hot, Teflon and Air, were situated in the 1994 NEMA Phantom. Phantom was filled with 27.3 MBq/mL of 18F-FDG. The ratio of hotspot area activity to background area activity was regulated as 4:1. After scanning, Image was re-reconstructed after incurring input errors in Activity, Weight, uptake Time parameters as ${\pm}5%$, 10%, 15%, 30%, 50% from original data. ROIs (region of interests) were set one in the each insert areas and four in the background areas. $SUV_{mean}$ and percentage differences were calculated and compared in each areas. Results: $SUV_{mean}$ of Hot. Teflon, Air and BKG (Background) areas of original images were 4.5, 0.02. 0.1 and 1.0. The min and max value of $SUV_{mean}$ according to change of Activity error were 3.0 and 9.0 in Hot, 0.01 and 0.04 in Teflon, 0.1 and 0.3 in Air, 0.6 and 2.0 in BKG areas. And percentage differences were equally from -33% to 100%. In case of Weight error showed $SUV_{mean}$ as 2.2 and 6.7 in Hot, 0.01 and 0.03 in Tefron, 0.09 and 0.28 in Air, 0.5 and 1.5 in BKG areas. And percentage differences were equally from -50% to 50% except Teflon area's percentage deference that was from -50% to 52%. In case of uptake Time error showed $SUV_{mean}$ as 3.8 and 5.3 in Hot, 0.01 and 0.02 in Teflon, 0.1 and 0.2 in Air, 0.8 and 1.2 in BKG areas. And percentage differences were equally from 17% to -14% in Hot and BKG areas. Teflon area's percentage difference was from -50% to 52% and Air area's one was from -12% to 20%. Conclusion: As shown in the results, It was applied within ${\pm}5%$ of Activity and Weight errors if the allowable error range was configured within 5%. So, The calibration of dose calibrator and weighing machine has to conduct within ${\pm}5%$ error range because they can affect to Activity and Weight rates. In case of Time error, it showed separate error ranges according to the type of inserts. It showed within 5% error when Hot and BKG areas error were within ${\pm}15%$. So we have to consider each time errors if we use more than two clocks included scanner's one during the examinations.

  • PDF

Effect of Feeding with High γ-Aminobutyric Acid (GABA) Containing Giant Embryo Black Sticky Rice (Oryza sativa L.) on Alcohol Intake in C57BL/6 Mice (GABA 고함유 흑찰거대배아미의 투여가 C57BL/6형 생쥐의 알코올 섭취량에 미치는 영향)

  • Kim, Hyeun-Kyeung;Kim, Sung-Gon;Lee, Jin-Sung;Lee, Sang-Shin;Jung, Woo-Young;Han, Sang-Ik;Kim, Byung-Ju
    • Journal of Life Science
    • /
    • v.23 no.5
    • /
    • pp.698-702
    • /
    • 2013
  • It is known that black sticky rice with giant embryo (BSRGB, Milyang 263) and giant embryo rice (GER) contains higher levels of GABA than rice. Therefore, feeding BSRGB, GER, or rice freely to C57BL/6 mice with two-hour alcohol intake for 16 days was investigated. For two-hour alcohol intake, a repeated measure ANOVA (three treatment groups repeated across 16 days; 8 two-day blocks) yielded a significant group by block interaction (df=16, F=3.109, p=0.004). The independent t-test showed that significant suppression of two-hour alcohol intake was observed when subjects were administered with BSRGB, compared with the rice alone across all the two-day blocks (p<0.05). The paired t-test revealed that a significant suppression of two-hour alcohol intake was observed starting 4 to 16 days after freely feeding with BSRGB compared to before feeding. However, there is no significant difference in the two-hour alcohol intake observed between the before and after administration of rice. A repeated measure ANOVA revealed no significant group by block interaction for 22-hour water intake and body weight. However, a repeated measure ANOVA revealed a significant grouping by block interaction for food intake. These results indicate a change of two-hour alcohol intake is presumably caused by GABA, which is found in higher levels in BSRGB than in rice.