Browse > Article
http://dx.doi.org/10.5395/JKACD.2002.27.4.370

INFRARED THERMOGRAPHIC ANALYSIS OF TEMPERATURE RISE ON THE SURFACE OF BUCHANAN PLUGGER  

Choi, Sung-A (Dept. of Conservative Dentistry, College of Dentistry, DSRI, Chonnam Natl. Uni.)
Kim, Sun-Ho (Dept. of Conservative Dentistry, College of Dentistry, DSRI, Chonnam Natl. Uni.)
Hwang, Yun-Chan (Dept. of Conservative Dentistry, College of Dentistry, DSRI, Chonnam Natl. Uni.)
Youn, Chang (Dept. of Conservative Dentistry, College of Dentistry, DSRI, Chonnam Natl. Uni.)
Oh, Byung-Ju (Dept. of Conservative Dentistry, College of Dentistry, DSRI, Chonnam Natl. Uni.)
Choi, Bo-Young (School of Mechanical Systems Engineering College of Engineering, Chonnam Natl. Uni.)
Juhng, Woo-Nam (School of Mechanical Systems Engineering College of Engineering, Chonnam Natl. Uni.)
Jeong, Sun-Wa (Dept. of Dentistry, College of Medicine, Seonam University)
Hwang, In-Nam (Dept. of Conservative Dentistry, College of Dentistry, DSRI, Chonnam Natl. Uni)
Oh, Won-Mann (Dept. of Conservative Dentistry, College of Dentistry, DSRI, Chonnam Natl. Uni)
Publication Information
Restorative Dentistry and Endodontics / v.27, no.4, 2002 , pp. 370-381 More about this Journal
Abstract
This study was performed to evaluate the temperature rise on various position of the Buchanan plugger, the peak temperature of plugger's type and the temperature change by its touching time of heat control spling. The heat carrier system 'System B' (Model 1005, Analytic Technologies, USA) and the Buchanan's plug-gers of F, FM, M and ML sizes are used for this study. The temperature was set to 20$0^{\circ}C$ which Dr. Buchanan's "continuous wave of condensation" technique recommended on digital display and the power level on it was set to 10. In order to apply heat on the Buchanan's pluggers, the heat control spring was touched for 1, 2, 3, 4 and 5 seconds respectively. The temperature rise on the surface of the pluggers were measured at 0.5 mm intervals from tip to 20 mm length of shank using the infrared thermography (Radiation Thermometer-IR Temper, NEC San-ei Instruments, Ltd, Japan) and TH31-702 Data capture software program (NEC San-ei Instruments, Ltd, Japan). Data were analyzed using a one way ANOVA followed by Duncan's multiple range test and linear regression test. The results as follows. 1. The position at which temperature peaked was approximately at 0.5 mm to 1.5 mm far from the tip of Buchanan's pluggers (p<0.001). The temperature was constantly decreased toward the shank from the tip of it (p<0.001). 2. When the pluggerss were heated over 5 seconds, the peak temperature by time of measurement revealed from 253.3$\pm$10.5$^{\circ}C$ to 192.1$\pm$3.3$^{\circ}C$ in a touch for 1 sec, from 218.6$\pm$5.$0^{\circ}C$ to 179.5$\pm$4.2$^{\circ}C$ in a touch for 2 sec, from 197.5$\pm$3.$0^{\circ}C$ to 167.5$\pm$3.7$^{\circ}C$ in a touch for 3 sec, from 183.7$\pm$2.5$^{\circ}C$ to 159.8$\pm$3.6$^{\circ}C$ in a touch for 4 sec and from 164.9$\pm$2.$0^{\circ}C$ to 158.4$\pm$1.8$^{\circ}C$ in a touch for 5 sec. A touch for 1 sec showed the highest peak temperature, followed by, in descending order, 2 sec, 3 sec, 4 sec. A touch for 5 sec showed the lowest peak temperature (p<0.001). 3. A each type of pluggers showed different peak temperatures. The peak temperature was the highest in F type and followed by, in descending order, M type, ML type. FM type revealed the lowest peak temperature (p<0.001). The results of this study indicated that pluggers are designed to concentrate heat at around its tip, its actual temperature does not correlate well with the temperature which Buchanan's "continuous wave of condensation" technique recommend, and finally a quick touch of heat control spring for 1sec reveals the highest temperature rise.
Keywords
Infrared thermographic analysis; Buchanan plugger;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Weller RN. Jurcak JJ, Donley DL, Kulild JC : A new model system for measuring intracanal temperatures. J Endod 17:491-494, 1991   DOI   ScienceOn
2 Floren JW. Weller RN. Pashley DB, Kimbrough WF :Changes in root surface temperatures with in vitro use of the system B HeatSource. J Endod 25:593-595, 1999   DOI   ScienceOn
3 Buchanan LS : Continuous wave technique. Dentistry today 1:60-64. 1996
4 Jurcak JJ. Weller RN. Kulild JC. Donley DL : In vitro intracanal temperatures produced during warm lateral condensation of guttapercha. J Endod 18: 1-3. 1992   DOI   ScienceOn
5 Eriksson AR. Albrektsson T : The effect of heat on bone regeneration. Oral Surg 42: 705-711, 1984   DOI   ScienceOn
6 Biagioni PA, Longmore RB, McGimpsey JG. Lamey P-J: Infrared thermography - its role in dental research with particular reference to craniomandibular disorders. Dentomaxillofacial Radiology 25: 119-124. 1996   DOI
7 Hand RE, Hugel EF. Tsaknis PJ : Effect of a warm gutta-percha technique on the lateral periodontium. Oral Surg 42:395-401, 1976   DOI   ScienceOn
8 Analytic Technology Corp. Instruction guidelines for system B HeatSource model 1005. Redmond, WA: Analytic Technology Corp., 1997
9 Eriksson A. Albrektsson T, Grane B, McQueen D : Thermal injury to bone : a vital-microscopic description of heat effect. Int J Oral Surg 11: 115-121, 1982   DOI
10 Marlin J, Schilder H : Physicial properties of guttaperch a when subjected to heat and vertical condensation. Oral Surg 36:872-879, 1973   DOI   ScienceOn
11 Barkhordar RA. Goodis HE, Watanabe L, Koundjian J : Evaluation of teeth during root canal obturation technique. Quint Int 21:585-588. 1990
12 Nguyen NT : Obturation of the Root Canal System. Pathways of the Pulp. 6th ed., St. Louis. Mosby Co., 1994. pp 219-271
13 Eriksson AR. Albrektsson T : Temperature threshold levels for heat-induced bone tissue injury : a vital-microscopic study in the rabbit. J Prosthet Dent 50:101-107,1983   DOI   ScienceOn
14 Lee FS, Van Cura JE, BeGole E : A comparison of root surface temperatures using different obturation heat sources, J Endod 24:617-620, 1998   DOI   ScienceOn
15 McCullagh JJ, Setchell DJ. Gulabivala K. Hussey DL, Biagioni P, Lamey PJ, Bailey G : A comparison of thermocouple and infrared thermographic analysis of temperature rise on the root surface during the continuous wave of condensation technique. Int Endod J 33:326-332, 2000   DOI   ScienceOn
16 Schilder H : Filling root canals in three dimensions. Dent Clin North Am 11:723-744, 1967