• 제목/요약/키워드: $A_0$ Mode

Search Result 4,019, Processing Time 0.034 seconds

Study for Block Cipher Operating Mode Using Counter (카운터를 사용한 블록암호 운영모드에 관한 연구)

  • Yang, Sang-Keun;Kim, Gil-Ho;Park, Chang-Soo;Cho, Gyeong-Yeon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.10a
    • /
    • pp.243-246
    • /
    • 2008
  • This thesis suggests block cipher operating mode using ASR(Arithmetic Shift Register). ASR is ratted arithmetic shift register which is sequence that is not 0 but initial value $A_0$ multiplies not 0 or 1 but free number D on $GF(2^n)$. This thesis proposes ASR mode which changes output multiplying d and Floating ASR mode which has same function but having strengthened stability altering d. If we use ASR's output as a counter, there's advantage that it has higher stability and better speed than CTR. Also, ASR mode and FASR mode have advantage of Random access which is not being functioned on CTR mode, they can be widely used to any part which Random access is needed.

  • PDF

Design of Current-to-Voltage Converter for the Current-mode FFT LSI in 0.35um processing (0.35um 공정에서 OFDM 용 전류모드 FFT LSI를 위한 I-V Converter 설계)

  • Bae, Seong-Ho;Hong, Sun-Yang;Jeon, Seong-Yong;Kim, Seong-Gwon
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2007.04a
    • /
    • pp.469-472
    • /
    • 2007
  • 최근 많은 광대역 유무선 통신 응용분야에서 OFDM(Orthogonal Frequency Division Multiplexing) 방식을 표준기술로 채택하고 있다 OFDM 방식의 고속 무선 데이터 통신를 위한 FFT 프로세서는 일반적으로 DSP(Digital Signal Processing)로 구현되었으나, 큰 전력 소비를 필요로 한다. OFDM의 단점인 전력문제를 보안하기 위해서 Current-mode FFT LSI가 제안되었다. 본 논문에서는 Current-mode FFT LSI의 구현을 위한 저전력 IVC를 설계하였다. 설계된 IVC는 FFT Block의 출력이 $13.65{\mu}A$ 이상일 때에 3V 이상의 전압을 출력하고, FFT Block의 출력이 $0.15{\mu}A$ 이하일 때에 0.5V 이하의 전압을 출력한다. 그리고 IVC의 총 소모전력은 약 1.65mW이다. $0.35{\mu}A$ 공정에서의 저전력 IVC를 설계함으로서, $0.35{\mu}A$ 공정에서의 Current-mode FFT LSI의 설계가 가능해졌다. 저전력 OFDM 통신용 Current-mode FFT LSI는 무선통신의 발전에 기여할 것으로 전망한다.

  • PDF

Experimental Evidence and Analysis of a Mode Conversion of Guided Wave Using Magnetostrictive Strip Transducer (자기변형 스트립 탐촉자에 의한 유도초음파 모드 변환에 대한 실험적 검증 및 해석)

  • Cheong, Yong-Moo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.2
    • /
    • pp.93-97
    • /
    • 2009
  • An advantage of a magnetostrictive strip transducer for a long-range guided wave inspection is that the wave patterns are relatively clear and simple when compared to a conventional piezoelectric ultrasonic transducer. Therefore, if we can characterize the evolution of defect signals, it could be a promising tool for a structural health monitoring of pipes for a long period of time as well as an identification of flaws. However, when evaluating a signal during a realistic field examination, it should be careful because of some spurious signals or false indications, such as signals due to a directionality, multiple reflections, mode conversion, geometrical reflections etc. Mode converted signals from a realistic piping mockup were acquired and analysed. We found mode conversions between a torsional guided wave T(0,1) mode and a flexural F(1,3) or longitudinal L(0,2) mode generated by a magnetostrictive strip transducer. Based on the experimental observations, an interpretation of the source of the mode conversion is discussed in a viewpoint of electromagnetic properties and structure of the strip transducer.

Distributions on F0 and Amplitude of Persons with Cerebral Palsy in the Reading Task (읽기과제에서 나타난 뇌성마비인의 기본주파수 및 진폭의 분포 특성)

  • Nam, Hyun-Wook;Choi, Yang-Gyu
    • MALSORI
    • /
    • no.66
    • /
    • pp.1-20
    • /
    • 2008
  • The purpose of this study was to investigate the characteristics of fundamental frequency(F0) and amplitude distributions in persons with cerebral palsy(CP) in the reading task. Participants were divided into three groups: 6 persons with spastic CP, 6 persons with athetoid CP and 6 normal persons who are around 15-20 years old. On the results of this study, firstly, in F0 distributions, most of the spastic CPs tended to appear narrow distributions on the basis of mode, but most of the athetoid CPs were opposite, and both of the CP groups tended to distribute highly on lower and higher frequencies than mean and mode. On the other hand, normal persons had a tendency to appear narrow distributions on the basis of mode. Finally, in amplitude distributions, the spastic CPs showed a tendency that there are little differences between the distribution of mode and the others, and most of the athetoid CPs showed a tendency that the distributions of mode were higher than the others. In addition to, the normal persons had a tendency that the distributions of mode were remarkably higher than both of the CP groups.

  • PDF

A Study on Failure Mode and Effect Analysis (FMEA) for Preoperative Risk Prevention (오류유형 영향분석(FMEA)을 적용한 수술준비 위험예방활동의 효과)

  • Kim, Chang Hee;Lee, Mi Hyang
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.22 no.5
    • /
    • pp.415-423
    • /
    • 2016
  • Purpose: The purpose of this research was to provide patients with safe preoperative preparatory procedures by removing any risk factors from the preparatory procedures by using failure mode and effects analysis, which is a prospective risk-managing tool. Methods: This was a research design in which before and after conditions of a single group were studied, Failure mode and effects analysis were applied for the preparatory procedures done before operations. Results: The preparation omission rate before the operation decreased from 2.70% to 0.04%, and operation cancellation rate decreased from 0.48% to 0.08%. Conclusion: Failure mode and effects analysis which remove any risk factors for patients in advance of the operation is effective in preventing any negligent accidents.

Fatigue Crack Propagation Behavior in STS304 Under Mixed-Mode Loading

  • Lee, Jeong-Moo;Song, Sam-Hong
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.796-804
    • /
    • 2003
  • The use of fracture mechanics has traditionally concentrated on crack growth under an opening mechanism. However, many service failures occur from cracks subjected to mixed-mode loading. Hence, it is necessary to evaluate the fatigue behavior under mixed-mode loading. Under mixed-mode loading, not only the fatigue crack propagation rate is of importance, but also the crack propagation direction. In modified range 0.3$\leq$a/W$\leq$0.5, the stress intensity factors (SIFs) of mode I and mode II for the compact tension shear (CTS) specimen were calculated by using elastic finite element analysis. The propagation behavior of the fatigue cracks of cold rolled stainless steels (STS304) under mixed-mode conditions was evaluated by using K$\_$I/ and $_{4}$ (SIFs of mode I and mode II). The maximum tangential stress (MTS) criterion and stress intensity factor were applied to predict the crack propagation direction and the propagation behavior of fatigue cracks.

Effect of Grating Phase in DFB Lasers with an Anti-reflection Coated Mirror (AR 코팅된 DFB 레이저에서 격자 위상의 영향)

  • Kwon, Kee-young;Ki, Jang-geun;Cho, Hyun-mook
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.3
    • /
    • pp.463-468
    • /
    • 2021
  • In this paper, when a refractive index grating and a gain grating were simultaneously present in a DFB laser having a wavelength of 1.55 ㎛, a dielectric film coating was applied so that reflection did not occur on the right mirror surface, so that 𝜌r=0. In case of 𝛿L>0, the characteristics of the oscillation frequency and oscillation gain were analyzed. When the grating phase of the left mirror surface continues to decrease from 𝜋, the graph lines of each mode gradually shift to the left. In case of 𝜅L=10, the threshold gain of the oscillation mode is the lowest. In this case, the mode selectivity is relatively low. From 𝜅L=0.5 to 𝜅L=6, the mode selectivity and the frequency stability are excellent. In the case of DFB lasers with an anti-reflection coated mirror, the threshold gain of the oscillation mode increases but the mode selectivity is about twice as excellent, compared with DFB lasers of having two cleaved facets.

Fast Intra Prediction Mode Decision based on Rough Mode Decision and Most Probable Mode in HEVC (Rough Mode Decision과 Most Probable Mode에 기반을 둔 HEVC 고속 인트라 예측 모드 결정 방법)

  • Lee, Seung-Ho;Park, Sang-Hyo;Jang, Euee Seon
    • Journal of Broadcast Engineering
    • /
    • v.19 no.2
    • /
    • pp.158-165
    • /
    • 2014
  • High Efficiency Video Coding (HEVC), the latest video coding standard, has twice of the compression efficiency compared to AVC/H.264 under the same image quality condition. To obtain the improved efficiency, however, it was adopted for many methods which need complicated calculation, and the time complexity of HEVC was increased more than that of AVC/H.264. To solve this problem, the various fast algorithms have been researched. In this paper, we propose a fast intra prediction mode decision method which uses result of Rough Mode Decision (RMD) and Most Probable Mode (MPM). The proposed method selects a best predicted mode by comparing each predicted directions which are calculated through RMD and MPM. We applied the proposed method to HM 10.0 and conducted an comparing experiment in All-Intra environment. The experiment result showed that total encoding time is reduced by about 26% on average with about a 0.8% loss of BD-rate.

A Study on Changes in Body Surface Temperature and Thermal Effect According to Ultrasound Mode (초음파 진단모드에 따른 체표면 온도변화와 열효과에 관한 고찰)

  • Yang, Sung-Hee;Lee, Jin-Soo
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.213-218
    • /
    • 2017
  • Recently, as the number of high-risk pregnancies increases, the use of new techniques such as Doppler, which have higher acoustic power than in the past, has been increasingly used in prenatal diagnosis and guidelines have been set up by various organizations to prevent excessive exposure. Therefore, in this study, we tried to investigate the temperature change of the body surface for each test mode according to the long time ultrasound examination and to examine the exposure time which is not influenced by the thermal effect. B mode, C mode, and PD mode according to time, and the temperature difference between exposed and unexposed sites were compared. As a result, the B mode showed a significant difference in the temperature change from 10 minutes, 50 minutes after exposed, 20 minutes from the C mode, and 30 minutes from the PD mode (p<0.01). In all three modes, the temperature difference was different (p<0.000), and PD mode was the most sensitive to temperature change. Also, it was found that the temperature rise time was shortened with the increase of the ultrasonic exposure time. Therefore, it is recommended that ultrasonography to observe the embryo or fetus should be used only for diagnostic purposes, avoiding excessive test time.

A Reduced-Swing Voltage-Mode Driver for Low-Power Multi-Gb/s Transmitters

  • Song, Hee-Soo;Kim, Su-Hwan;Jeong, Deog-Kyoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.9 no.2
    • /
    • pp.104-109
    • /
    • 2009
  • At a lower supply voltage, voltage-mode drivers draw less current than current-mode drivers. In this paper, we newly propose a voltage-mode driver with an additional current path that reduces the output voltage swing without the need for complicated additional circuitry, compared to conventional voltage-mode drivers. The prototype driver is fabriccated in a 0.13-$^{\mu}m$ CMOS technology and used to transmit data streams at the rate of 2.5 Gb/s. Deemphasis is also implemented for the compensation of channel attenuation. With a 1.2-V supply, it dissipates 8.0 mA for a 400-mV output voltage swing.