• Title/Summary/Keyword: work flow

Search Result 2,764, Processing Time 0.035 seconds

A Study On Construction Project Expected Effect Collaboration Business Design Management (협업 설계관리를 통한 건설 프로젝트 기대효과에 관한 연구)

  • Nam, Hye-Won;Lee, Jong-Sik;Chun, Jae-Youl
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2007.11a
    • /
    • pp.589-592
    • /
    • 2007
  • While it is these days, and is increased importance as opposed to design management in managing a construction business necessity as opposed to collaboration business design management between collaboration business business company is regarded as important. An object was put in deriving a flow of a design process about the design management business and a grasp, management element as opposed to management by reason of the first, building design business ability improvement by a study of a book hereby, and an alternative plan of collaboration business design management for use in design optimization of difficulty of a disagreement, workshop modification city design information chase between books by lack of collaboration business between things of each minimization, company was shown with, air in a base in problems grasp as opposed to a collaboration business design by the second" work-site operations and a design process management element. Therefore, this thesis is going to show expected effect of a project about collaboration business design management through systematic practical use about a collaboration business design.

  • PDF

Development of PEID for Acquiring Maintenance Information during Product Lifecycle of Marine Vessels (선박해양구조물의 제품수명주기 내 유지보수 정보 획득을 위한 PEID에 관한 연구)

  • Jeon, Jeong-Ik;Lee, Jang-Hyun;Son, Gum-Jun
    • Journal of Ocean Engineering and Technology
    • /
    • v.26 no.5
    • /
    • pp.63-72
    • /
    • 2012
  • The product lifecycle of a marine vessel can be classified into the design-production, operation-maintenance, and disposal phases. During the operation and maintenance phase, status data should be gathered from the major machinery and instruments installed on the marine vessel in order to perform efficient maintenance work. Although a PLM (product lifecycle management) system can manage the product information during the design and assembly stage, a PLM based on asset management technology is more appropriate for product information management during the operation stage. Product embedded information devices (PEIDs) are suggested for gathering real-time maintenance information during the operation and maintenance lifecycle. A PEID allows PLM to provide the capability of offering active information exchange between the lifecycle management system and equipment. This study designed a PEID to effectively obtain information and interact with a PLM system. It consists of sensors, wireless communication, and a micro-processor, which allow it to accumulate status data on the PLM system. The embedded information device and PLM enable the seamless information flow, tracking, and updating of MRO (maintenance repair and overhaul) information for a product throughout the middle of the product lifecycle.

Inductively Coupled Plasma Etching of GST Thin Films in $Cl_2$/Ar Chemistry ($Cl_2$/Ar 분위기에서 GST 박막의 ICP 에칭)

  • Yoo, Kum-Pyo;Park, Eun-Jin;Kim, Man-Su;Yi, Seung-Hwan;Kwon, Kwang-Ho;Min, Nam-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1438-1439
    • /
    • 2006
  • $Ge_{2}Sb_{2}Te_5$(GST) thin film at present is a promising candidate for a phase change random access memory (PCRAM) based on the difference in resistivity between the crystalline and amorphous phase. PCRAM is an easy to manufacture, low cost storage technology with a high storage density. Therefore today several major chip in manufacturers are investigating this data storage technique. Recently, A. Pirovano et al. showed that PCRAM can be safely scaled down to the 65 nm technology node. G. T Jeonget al. suggested that physical limit of PRAM scaling will be around 10 nm node. Etching process of GST thin ra films below 100 nm range becomes more challenging. However, not much information is available in this area. In this work, we report on a parametric study of ICP etching of GST thin films in $Cl_2$/Ar chemistry. The etching characteristics of $Ge_{2}Sb_{2}Te_5$ thin films were investigated using an inductively coupled plasma (ICP) of $Cl_2$/Ar gas mixture. The etch rate of the GST films increased with increasing $Cl_2$ flow rate, source and bias powers, and pressure. The selectivity of GST over the $SiO_2$ films was higher than 10:1. X-ray photoelectron spectroscopy(XPS) was performed to examine the chemical species present in the etched surface of GST thin films. XPS results showed that the etch rate-determining element among the Ge, Sb, and Te was Te in the $Cl_2$/Ar plasma.

  • PDF

Removal of Organic Load from Olive Washing Water by an Aerated Submerged Biofilter and Profiling of the Bacterial Community Involved in the Process

  • Pozo, Clementina;Rodelas, Belen;Martinez-Toledo, M. Victoria;Vilchez, Ramiro;Gonzalez-Lopez, Jesus
    • Journal of Microbiology and Biotechnology
    • /
    • v.17 no.5
    • /
    • pp.784-791
    • /
    • 2007
  • The present work aims to use a biofilter technology(aerated submerged filters) for the aerobic transformation at laboratory-scale of olive washing water(OWW) generated in the first steps of olive oil processing, as well as the genetic profiling and identification to the species level of the bacteria involved in the formation of the biofilm, by means of TGGE. Chemical parameters, such as biological oxygen demand at five days($BOD_5$) and chemical oxygen demand(COD), decreased markedly(up to 90 and 85%, respectively) by the biological treatment, and the efficiency of the process was significantly affected by aeration and inlet flow rates. The total polyphenol content of inlet OWW was only moderately reduced(around 50% decrease of the inlet content) after the biofilter treatment, under the conditions tested. Partial 16S rRNA genes were amplified using total DNA extracted from the biofilm and separated by TGGE. Sequences of isolated bands were mostly affiliated to the $\alpha-subclass$ of Proteobacteria, and often branched in the periphery of bacteria] genera commonly present in soil(Rhizobium, Reichenowia, Agrobacterium, and Sphingomonas). The data obtained by the experimentation at laboratory scale provided results that support the suitability of the submerged filter technology for the treatment of olive washing waters with the purpose of its reutilization.

Estimation of the Pollutant Loads from Paddy Fields by Cultivation Practices Using a Non-point-source Model (비점원오염모델을 이용한 논의 영농방법별 오염부하량 예측)

  • Han, Kuk-Heon
    • Korean Journal of Environmental Agriculture
    • /
    • v.27 no.1
    • /
    • pp.10-17
    • /
    • 2008
  • The objective of this study was to estimate the pollutant loads from paddy fields by cultivation practices using a non-point-sources models. One of them is CREAMS-PADDY model that was developed considering the water balance and mass balance of paddy fields. The CREAMS-PADDY model was applied to provide basic data to reduce runoff loadings under various scenarios such as various water management control and various fertilizer condition. The model was verified against T-N, T-P and runoff flow data collected during cropping periods at 2000. The model results agreed well with the measured data in verification. The results showed that the model could be used for estimating the runoff loadings from irrigated paddy fields by cultivation practices was possible. Comparison of simulated the standard height and the sluice management of T-N and T-P runoff loadings from paddy fields were +32.4%, +10.3% in 10 mm below the standard height, -29.2%, -35.9% in 20 mm above the standard height, 52.6%, 59.0% in 40 mm above the standard height, respectively. Comparison of simulated the standard fertilizer and the fertilizer control of T-N and T-P runoff loadings from paddy fields were -1.3%, -21.7%in reduction of conventional fertilizer 30%, -1.0%, -12.5% in reduction of standard fertilizer 30%, respectively. Therefore, reducing nonpoint-sources nutrient loading by reducing fertilization may not work well in the range of normal paddy rice farming practices, and instead it could be achieved by reducing surface drainage outflow.

Algorithm for the Low-Voltage Feeder Design in Consideration of Voltage Drop (전압강하를 고려한 저압간선의 설계 알고리즘)

  • 고영곤;최홍규;조계술
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.3
    • /
    • pp.84-92
    • /
    • 2002
  • A size of low-voltage conductor cables is determined by the voltage drop of a system the cable impedance and the cable ampacity based on temperature correction factor in accordance with the condition of cable installation. Therefore, the proper temperation correction factor according to the condition of cable installation should be applied to determining the cable ampacity and also the skin effect and proximity effect, along with the kind and size of conductor and the condition of cable installation, should be properly considered to analyze the proper value of resistance and the reactance of the conductors. This paper addresses the systematic design flow for determining the size of low voltage level con여ctor cables in calculating the voltage drop of a power system and proposes a new improved the calculating formula what error should be minimized in comparison with the general formula and which can be applied in design work for determining the size of conductor cables.

The Road Cross Section Evaluation With The Rotational Laser Scanner (회전식 레이저를 이용한 도로 횡단경사 평가에 관한 연구)

  • Lee, Jun Seok;Yun, Duk-Geun;Sung, Jung-Gon
    • International Journal of Highway Engineering
    • /
    • v.12 no.4
    • /
    • pp.71-78
    • /
    • 2010
  • The road safety depend on many road factors like vertical alignment, horizontal alignment and road cross section angle. These data are hardly to get with drawings, and the real data are differ from drawings because of road pavement overlay, etc. To get these data, so many time and cost are needed, moreover it is dangerous work in heavy traffic road. In this study we obtained the road safety data with RoSSAV(Road Safety Survey & Analysis Vehicle) of Korea Institute of Construction Technology in accordance with traffic flow, and make analysis of road safety with the vertical alignment, horizontal alignment and road cross section angle data. We derived the safety improvement method in Young-dong accident prone spot and described detail method in this paper.

A study on the reduction of indoor radon contamination (실내 라돈의 오염량 감소에 관한 연구)

  • Kim, Chang-Kyun;Choi, Jong-Hak;Kang, Jeong-Ho
    • Journal of radiological science and technology
    • /
    • v.29 no.2
    • /
    • pp.53-56
    • /
    • 2006
  • The purpose of the present study is to find ways to reduce the quantity of indoor radon contamination. The study was done from July, 2005 until December, 2005. It was found out that the easiest and most effective way to do that is to open the windows as often as possible and let the indoor air flow outside. When it is not possible to ventilate a room, the indoor radon contamination quantity can reduced by providing activated charcoal in the room. It has been proved that activated charcoal can absorb the room in the air. We need more activated charcoal in proportion to the size of the room. A further research is needed to investigate the amount of activated charcoal that will work most effectively.

  • PDF

Assessment of Transfer Center by Facility Design Analysis (설계분석 프로그램을 이용한 환승센터 내부 및 외부 시설물 평가)

  • Lee, Jeong-Yeop;Han, Dong-Hui;Lee, Ju-Yeong;Lee, Yeong-In
    • Journal of Korean Society of Transportation
    • /
    • v.27 no.5
    • /
    • pp.169-177
    • /
    • 2009
  • Establishing a public transportation transfer system that can reduce personal automobile use in the CBD and absorb the demand, thereby reducing congestion, is a necessity. However, the current transfer system and facilities are lacking in intermodal connectivity, require long transfer times, have complex flow patterns, and are lacking in information systems and convenience. The design analysis program of this study is to develop a program that executes computations of design analysis of transfer facilities by utilizing the existing design standards for facilities such as facilities for boarding and alighting, elements for convenience, and pedestrian facilities. Developing an analytical tool through which individual or integrated design analysis can be conducted on the design standards of various facilities is an important study for improving the work accuracy and efficiency of designing an actual transfer center.

Optical Properties Analysis of SiNx Double Layer Anti Reflection Coating by PECVD

  • Gong, Dae-Yeong;Park, Seung-Man;Yi, Jun-Sin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.149-149
    • /
    • 2010
  • The double-layer antireflection (DLAR) coatings have significant advantages over single-layer antireflection (SLAR) coatings. This is because they will be able to cover a broad range of the solar spectrum which would enhance the overall performance of solar cells. Moreover films deposited at high frequency are expected to show excellent and UV-stable passivation in the refractive index that we adopted. In this work, we present a novel DLAR coating using SiNx:H thin films with refractive indices 1.9 and 2.3 as the top and bottom layers. This approach is cost effective when compared to earlier DLAR coatings with two different materials. SiNx:H films were deposited by Plasma enhanced chemical vapor deposition (PECVD) technique using $SiH_4$, $NH_3$ and $N_2$ gases with flow rates 20~80sccm, 200sccm and 85 sccm respectively. The RF power, plasma frequency and substrate temperature for the deposition were 300W, 13.56 MHz and $450^{\circ}C$, respectively. The optimum thickness and refractive indices values for DLAR coatings were estimated theoretically using Macleod simulation software as 82.24 nm for 1.9 and 68.58 nm for 2.3 respectively. Solar cells were fabricated with SLAR and DLAR coatings of SiNx:H films and compared the cell efficacy. SiNx:H> films deposited at a substrate temperature of $450^{\circ}C$ and that at 300 W power showed best effective minority carrier lifetime around $50.8\;{\mu}s$. Average reflectance values of SLAR coatings with refractive indices 1.9, 2.05 and 2.3 were 10.1%, 9.66% and 9.33% respectively. In contrast, optimized DLAR coating showed a reflectance value as low as 8.98% in the wavelength range 300nm - 1100nm.

  • PDF