• Title/Summary/Keyword: width of device

Search Result 714, Processing Time 0.034 seconds

A Study on Improvement of Industrial Hood in Ventilation System for Elimination of Harmful Material and Dust (유해물질 및 공업용 분진 제거를 위한 산업용 후드 개선에 관한 연구)

  • Kim, Young-Sun;Oh, Yool-Kwon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.4
    • /
    • pp.238-244
    • /
    • 2008
  • This study investigates on the improvement of inhalation effect of hood which attached new device named as "gas-guide-device" in local exhaust ventilation system for the effective elimination of harmful material and dust in manufacturing factory. The gas-guide-device having a diamond shape is composed of width (b) and two sides of a device (X, Y) and its size is selected the industrial hood under application in manufacturing factory after due consideration. In order to investigate the effect of gas-guide-device, numerical and experimental study is performed that the flow velocity is calculated and is measured by a commercial program "COMSOL $Multiphysics^{TM}$" and a hot wire type of anemometer, respectively. The numerical and experimental results are revealed is a similar pattern and flow velocity has improved to hood attached gas-guide-device. Also, the numerical method and result is also verified the dependance. Moreover, the optimum shape and size of gas-guide-device is revealed that the width (b) and the ratio of two sides of gas-guide-device (X, Y) has 125mm and 4 to 6.

Does the maxillary anterior ratio in Korean adults follow the Golden Proportion?

  • Jin, Ming-Xu;Hong, Min-Ho;Lee, Kee-Joon;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.2
    • /
    • pp.125-130
    • /
    • 2016
  • PURPOSE. The purpose of this study was to determine the effect of changes in the horizontal plane angle on the mesiodistal width ratios of the maxillary anterior teeth during the acquisition of frontal view photographs, derive these ratios for Korean adults on the basis of the data obtained, and analyze them using the Golden Proportion as a reference. MATERIALS AND METHODS. In experiment I, 30 plaster casts were mounted on an articulator and positioned on the angle-measuring device with a center setting of $0^{\circ}$. The device was rotated to $10^{\circ}$ in $1^{\circ}$ increments in a counterclockwise direction. At each angle, photographs were obtained and analyzed. Experiment II was based on 60 patients who visited the Department of Prosthodontics at Kyungpook National University Dental Hospital from February 2012 to February 2015. The patients were divided into three groups [Male (M), Female (F), Total (M + F)]. Frontal views were obtained for all groups and analyzed. RESULTS. From $1^{\circ}$ to $10^{\circ}$, the relative mesiodistal width ratios for the maxillary anterior teeth showed no significant differences from those at $0^{\circ}$. In all three groups, the relative width ratio of the maxillary central incisor was smaller than that specified in the Golden Proportion; the opposite was true for the canine. CONCLUSION. Our results suggest that the mesiodistal width ratios of the maxillary anterior teeth do not follow the Golden Proportion in Korean adults, and that a change in the horizontal plane angle from $1^{\circ}$ to $10^{\circ}$ during frontal photography does not affect these ratios.

A study on the piezoelectric vibration device for mobile phone (이동통신 단말기용 압전 진동 장치에 관한 연구)

  • Yoo, J.S.;Kwon, O.D.;Yun, Y.J.;Kang, S.H.;Lim, K.J.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.379-382
    • /
    • 2004
  • In this paper, it is investigated in advance about the PZT-based composition for piezoelectric vibration device. The specimens of piezoelectric ceramics are made of Columbite method. The piezoelectric vibration device by this composition is designed by ATILA(Magsoft) program used FEM(Finite Element Method). The vibration device used for mobile phone must be driven in the frequency of $130{\sim}200Hz$, so the resonant frequency of piezoelectricity must adjust driven frequency bandwidth. The result of analysis by ATILA is appeared dependant property of length, width, thickness and dummy weight about resonant frequency of the piezoelectric vibration device. The size of manufactured actuator is $28{\times}12{\times}0.3mm^3(length {\times}width{\times}thickness)$ and this is bimorph type. The test of manufactured piezoelectric vibration device measure displacement, acceleration and power dissipation. The piezoelectric vibration device has the advantage more than electro-magnetic motor, however the size of manufactured device is larger than electro-magnetic motor.

  • PDF

Design Consideration of Bulk FinFETs with Locally-Separated-Channel Structures for Sub-50 nm DRAM Cell Transistors

  • Jung, Han-A-Reum;Park, Ki-Heung;Lee, Jong-Ho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.8 no.2
    • /
    • pp.156-163
    • /
    • 2008
  • We proposed a new $p^+/n^+$ gate locally-separated-channel (LSC) bulk FinFET which has vertically formed oxide region in the center of fin body, and device characteristics were optimized and compared with that of normal channel (NC) FinFET. Key device characteristics were investigated by changing length of $n^+$ poly-Si gate ($L_s$), the material filling the trench, and the width and length of the trench at a given gate length ($L_g$). Using 3-dimensional simulations, we confirmed that short-channel effects were properly suppressed although the fin width was the same as that of NC device. The LSC device having the trench non-overlapped with the source/drain diffusion region showed excellent $I_{off}$ suitable for sub-50 nm DRAM cell transistors. Design of the LSC devices were performed to get reasonable $L_s/L_g$ and channel fin width ($W_{cfin}$) at given $L_gs$ of 30 nm, 40 nm, and 50 nm.

Device Miniaturization Using Stepped Multimode-Interference Couplers (계단형 다중모드 간섭 결합기를 사용한 소자의 소형화)

  • Ho, Kwang-Chun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.1
    • /
    • pp.14-19
    • /
    • 2010
  • In this paper, a novel architecture for device miniaturization of multimode interference-based couplers (MMICs) is proposed by replacing conventionally designed MMICs by cascaded two-section stepped-width or stepped-index MMICs. For the 82% cross coupling efficiency in a stepped-width MMIC, the coupling length of device results in just 6.7% length reduction. However, for a stepped-width and stepped-index MMIC, the coupling efficiency increases to 93% and the length reduction of 9% occurs. Furthermore, with additional incorporation of tapered devices, it shows that a compact MMIC can be designed in which the coupling efficiency is 90% and the length is reduced to 25%.

Two Dimensional Size Effect on the Compressive Strength of T300/924C Carbon/Epoxy Composite Plates Considering Influence of an Anti-buckling Device (T300/924C 탄소섬유/에폭시 복합재 적층판의 이차원 압축 강도의 크기효과 및 좌굴방지장치의 영향)

  • ;;;C. Soutis
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.10a
    • /
    • pp.88-91
    • /
    • 2002
  • The two dimensional size effect of specimen gauge section (length x width) was investigated on the compressive behavior of a T300/924 [45/-45/0/90]3s, carbon fiber-epoxy laminate. A modified ICSTM compression test fixture was used together with an anti-buckling device to test 3mm thick specimens with a 30$\times$30, 50$\times$50, 70$\times$70, and 90mm$\times$90mm gauge length by width section. In all cases failure was sudden and occurred mainly within the gauge length. Post failure examination suggests that $0^{\circ}$ fiber microbuckling is the critical damage mechanism that causes final failure. This is the matrix dominated failure mode and its triggering depends very much on initial fiber waviness. It is suggested that manufacturing process and quality may play a significant role in determining the compressive strength. When the anti-buckling device was used on specimens, it was showed that the compressive strength with the device was slightly greater than that without the device due to surface friction between the specimen and the device by pretoque in bolts of the device. In the analysis result on influence of the anti-buckling device using the finite element method, it was found that the compressive strength with the anti-buckling device by loaded bolts was about 7% higher than actual compressive strength. Additionally, compressive tests on specimen with an open hole were performed. The local stress concentration arising from the hole dominates the strength of the laminate rather than the stresses in the bulk of the material. It is observed that the remote failure stress decreases with increasing hole size and specimen width but is generally well above the value one might predict from the elastic stress concentration factor. This suggests that the material is not ideally brittle and some stress relief occurs around the hole. X-ray radiography reveals that damage in the form of fiber microbuckling and delamination initiates at the edge of the hole at approximately 80% of the failure load and extends stably under increasing load before becoming unstable at a critical length of 2-3mm (depends on specimen geometry). This damage growth and failure are analysed by a linear cohesive zone model. Using the independently measured laminate parameters of unnotched compressive strength and in-plane fracture toughness the model predicts successfully the notched strength as a function of hole size and width.

  • PDF

TLP Properties Evaluation of ESD Protection Device of GGNMOS Type for Conventional CMOS Process (Conventional CMOS 공정을 위한 GGNMOS Type의 ESD 보호소자의 TLP 특성 평가)

  • Lee, Tae-Il;Kim, Hong-Bae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.10
    • /
    • pp.875-880
    • /
    • 2008
  • In this paper, we deal with the TLP evaluation results for GGNMOS in ESD protection device of conventional CMOS process. An evaluation parameter for GGNMOS is that repeatability evaluation for reference device($W/L=50\;{\mu}m1.0\;{\mu}m$) and following factors for design as gate width, number of finger, present or not for N+ gurad -ring, space of N-field region to contact and present or not for NLDD layer. The result of repeatability was showed uniformity of lower than 1 %. The result for design factor evaluation was ; 1) gate width leading to increase It2, 2) An increase o( finger number was raised current capability(It2), and 3) present of N+ gurad-ring was more effective than not them for current sink. Finally we suggest the optimized design conditions for GGNMOS in evaluated factor as ESD protection device of conventional CMOS process.

Development of Intelligent Filler Wire Feeding Device for Improvement of Weld quality (용접부 품질향상을 위한 지능형 용접 와이어 공급 장치 개발)

  • Lee J.S.;Sohn Y.I.;Park K.Y.;Lee K.D.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.950-955
    • /
    • 2005
  • This paper describes an intelligent filler wire feeding device which can control 3- dimensional seam tracking and the filler wire speed by measuring the gap position and the joint gap width in laser welding. By means of visual sensor controlled filling the missing material into the joint gap and 3 dimensional seam tracking, lineup errors from manufacturing tolerances and the repeatability of lineup jigs and weld robot can be balanced and at an even seam quality which avoids weld defects. In this paper, we assessed weld quality in 2mm sheets of A16061 which had various gap width by using the intelligent filler wire feeding device.

  • PDF

Geometric Optimization of a Microchannel for the Improvement of Temperature Gradient Focusing (온도기울기 농축(TGF) 향상을 위한 미세채널 형상 최적화 연구)

  • Han, Tae-Heon;Kim, Sun-Min
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.2
    • /
    • pp.17-24
    • /
    • 2011
  • Temperature gradient focusing (TGF) of analytes via Joule heating is achieved when electric field is applied along a microchannel of varying width. The effect of varying width of the microchannel for the focusing performance of the device was numerically studied. The governing equations were implemented into a quasi-1D numerical model along a microchannel. The validity of the numerical model was verified by a comparison between numerical and experimental results. The distributions of temperature, velocity, and concentration along a microchannel were predicted by the numerical results. The narrower middle width and wider outside width of the channel having the fixed length contribute to improve the focusing performance of the device. However, too narrow middle width of the channel generates a higher temperature which can cause the problems including sample denaturation and buffer solution boiling. Therefore, the channel geometry should be optimized to prevent these problems. The optimal widths of the microchannel for the improvement on TGF were proposed and this model can be easily applied to lab-on-a-chip (LOC) applications where focusing is required based on its simple design.

HOT STRIP WIDTH CONTROL METHOD BY USING LOOPER TENSION MEASURING SYSTEM IN FINISHING MILL (열간 사상압연 투퍼장력 측정에의한 열연판폭제어)

  • 홍완기;김필호;문영훈;이준정
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.08a
    • /
    • pp.423-428
    • /
    • 1999
  • A high precision hot strip width control method has been developed in this study by applying interstand looper tension measuring system at finishing mill stands. As with deviation of hot rolled steel strip is closely related to abnormal increase in the interstand strip tension, on-line measuring device of looped tension and data analyzing system was developed in this study. To determine dominant factors that will cause local width shortage, the logged data sets of bar width, bar thickness, looper tension, and strip thickness along the strip length were correlated with the data set of strip width change. With the result of the correlation analysis, existing sequence control logic and parameters for looper actuator were modified for strip width quality and the gains of the looper control were refined for the stable operation during the full passage of rolled strip. The on-line tension measurement and tension feedback control for looper system improved strip travelling stability and reduced strip width deviation in the srip top end region.

  • PDF