• Title/Summary/Keyword: water environment

Search Result 13,308, Processing Time 0.032 seconds

Control of Biofilms in the Drinking Water Distribution System (배·급수관망에서 생물막 제어)

  • Mun, Sungmin;Yoon, Jeyong
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.1
    • /
    • pp.1-11
    • /
    • 2007
  • The low nutrient environment in drinking water treatment plants and distribution systems cannot to be a good environment for bacterial growth. However, biofilms can be frequently found submerged surface in treatment plants and distribution system. Biofilms in distribution system are harmful, in that they can release organisms, and may cause problems in taste and odor of water. Control of these Biofilms is difficult, and disinfection alone is usually ineffective. Biofilms will not be eliminated from distribution systems by any contemporary technology available now or in the future. Therefore reduction of organic matter, improved disinfection, or a combination of these methods can be useful in controlling distribution system biofilms.

Development and Application of the Grid-Distributed Model for Contribution Rate Analysis on Non-point Source Pollution According to Landuse (토지피복별 비점부하량 기여율 해석을 위한 분포형 모델 개발 및 적용)

  • Ahn, Jung-Min;Jung, Kang-Young;Kim, Shin;Lee, Hae-Jin;Shin, Suk-Ho;Yang, Duk-Seok;Shin, Dongseok;Na, Seung-Min
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.1
    • /
    • pp.78-89
    • /
    • 2017
  • Water quality monitoring network data is being affected continuously due to non-point source pollution arising from agricultural land located on the Gwangsancheon outlet in the Nakdong River basin. In this study, we have performed analysis of water quality monitoring system, water quality pattern using SOM and water quality in the Gwangsancheon for sub-basin located at Gisan-myeon in the Nakdong River basin. We have developed and applied the model to estimate the runoff and non-point source loading. As a result of SOM pattern, the effect of non-point source pollution was the largest in the paddy fields and fields. As a result of the developed model, we found contribution rate and reduction rate for non-point source loading according to change of landuse because the reduction effect of nonpoint pollutants was 20.9% of SS, 9.9% of TN, 21.2% of TP and 8.9% of TOC depending on the landuse change.

The Regulations and Guidelines for Management of Corrosive Water and Pipe Corrosion in Drinking Water Distribution System in North America (상수원 관망 부식 제어를 위한 부식성 수질 관리: 북미지역 관리 사례 및 국외 현황)

  • Kim, Minhee;Hyun, Seunghun;Lee, Won-Seok;Loretta, Y. Li
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.3
    • /
    • pp.359-369
    • /
    • 2017
  • Water distribution systems supply drinking water to consumers' taps. Internal corrosion of metallic pipe used in drinking water distribution systems has reduced water quality and led to increased levels of toxic heavy metals such as lead, copper and nickel. These problems have been experienced to varying degrees by water utilities in many countries. North America has successfully managed and controlled pipe corrosion and corrosive water in water distribution system based on various policies, regulations and rules. Practical and engineering guidelines for evaluation of pipe corrosion and determination of treatment options are also provided to assist drinking water supplies. In addition, the corrosion mechanism in water distribution systems, such as the complex effects of physical and chemical parameters on the corrosion pipes has been improved to accurately predict corrosion rates of metallic pipes in actual water distribution systems. This paper reviews various regulations, policy statement, and treatment produces on controlling corrosion in drinking water distribution systems in US and Canada and then offers suggestion for management of corrosive water and pipe corrosion in drinking water distribution system in Korea.

Applicability of Water Quality Indicators as Target Pollutants for Total Maximum Daily Loads (수질오염총량관리를 위한 대상물질 적용성 분석)

  • Park, Jun Dae;Oh, Seung Young;Park, Jae Hong
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.4
    • /
    • pp.531-539
    • /
    • 2013
  • In order to apply a water quality indicator as a certain target pollutant, the indicator should have the representability of an index for the management of Total Maximum Daily Loads (TMDLs). Scientific groundwork and treatment technologies also should be provided for the application of the indicator. This study analyzed the applicability of major water quality indicators for target pollutants. The results showed that four water quality indicators of TOC, T-N, SS & T-Coli can be considered as target pollutants besides existing BOD and T-P. These indicators can be applied with the preparations such as essential basic data, pollution load estimation framework as well as legal criteria setting when the need is raised. As the importance of TOC, which is considered as a replacement of BOD, is emphasized, technical and institutional terms are being prepared in order to determine TOC as another target pollutant in the near future. It could be considered to combine TOC with BOD for the time being during the $3^{rd}$ stage of TMDLs in view of the present conditions for the management of TOC. TOC can be the most effective index for the organic matter and help to be managed more systematically in the waterbodies where rivers and lakes are mutually connected.

Analysis of Harmful Cyanobacteria Occurrence Characteristics and Effects of Environmental Factors (덕동호 유해남조류 출현 특성 및 환경요인 영향 분석)

  • Dong-Gyun Hong;Hae-Kyung Park;Yong-jin Kim
    • Journal of Korean Society on Water Environment
    • /
    • v.39 no.1
    • /
    • pp.20-29
    • /
    • 2023
  • This study analyzed the relationship between harmful cyanobacterial abundance and environmental factors in order to figure out the causes of the recent increase of cyanobacteria in Lake Dukdong from 2019 to 2021. Lake Dukdong, which is used as a drinking water source for Gyeongju City, has an algae alert system in place. Lake Dukdong has maintained good water quality, but algae alert level 1 (over 1,000 cells/mL) has been issued in recent years. As a result of Pearson correlation analysis (from May to Oct.), the cell density of Microcystis and Aphanizomenon, which form part of the most harmful cyanobacteria genus, were significantly positively correlated with the water temperature and water storage volume. T-test was performed to compare the data from 2016-2018 and 2019-2021 (from May to Oct.). The average density of harmful cyanobacteria cells increased about six-fold from 54 to 344 cells/mL. There were significant differences in water temperature, pH, total nitrogen (TN), total phosphorus (TP), TN/TP ratio, water storage volume, and cyanobacterial cell density. Water temperature increased from 19.2 to 22.8 ℃. TP concentration increased from 0.017 to 0.028 mg/L. The main cause of the recent increase of harmful cyanobacteria in Lake Dukdong is thought to be the increase in water temperature, TP concentration, and water storage volume from 2019 and 2021, resulting in more favorable conditions for cyanobacterial growth.

Study on Oxytetracycline Resistant Bacteria in the Surface Water Environment (하천에서의 Oxytetracycline 내성주에 관한 연구)

  • Kim, Young Jin;Kim, Jong Oh
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.1
    • /
    • pp.40-48
    • /
    • 2015
  • Objectives: This study aims to understand the concentration, diversity, and antibiotic characteristics of oxytetracycline resistant bacteria present in a surface water environment. Methods: Water sampling was performed in Cheongmi Stream in Gyeonggi-do, Korea in February and August 2014. Water samples collected from two sites were plated in triplicate on tryptic soy agar plates with 30 mg/L of oxytetracycline. Oxytetracycline resistant bacteria were selected from surface water in Cheongmi Stream and were subjected to 16S rDNA analysis for oxytetracycline resistant species determination. Identified resistant strains were tested for resistance to various antibiotics. Results: Results from this study indicate that the dominant resistant organisms in this aquatic environment are from family Acinetobacter and family Aeromonas. As to culturable heterotrophic bacteria, Oxytetracycline resistant bacteria were present 0.45-0.93% during winter and 0.08-0.38% during summer. Most oxytetracycline resistant bacteria exhibited resistance to more than ten of the antibiotics studied. The diversity of oxytetracycline resistant bacteria in winter was higher than in summer. Conclusion: Most of these resistant bacteria are Gram negative and are closely related to pathogenic species. These results suggest that increasing multi-antibiotic resistant bacteria in the surface water environment has a close relation to the reckless use of antibiotics in livestock.

The Estimation of Contribution Ratio for Sub Stream in Nam River Basin (남강유역 지류·지천별 영향도 평가)

  • Lee, Jae-Woon;Kwon, Heon-Gak;Kwak, In-Soo;Youn, Jong-Soo;Cheon, Se-Uk
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.5
    • /
    • pp.745-755
    • /
    • 2012
  • The relations between tributaries and mainstream were identified with the water qualities measurements in the field. Parameters of water qualities were BOD, T-N, T-P and measurements were performed by 4 events of rainfalls for 2011. The precipitation data influenced on pollutants loads. Pollutants loads were fluctuations with the seasonal variation. Gajoacheon contributed in 18.39% of BOD, 23.79% of T-N, 15.23% of T-P and Nabulcheon contributed in 13.54% of BOD, 13.05% of T-N and 13.66% of T-P in the region from Nam River_C to Nam River_D. In case of the region from Nam River_C to Nam River_D, Yongacheon river inflowed to main stream as 23.65% of BOD, 20.74% of T-N, and 15.05% of T-P.

Determination of Antibiotic Residues: II. Extraction and Clean-up Methods for Liquid Samples_A Review (시료 중 잔류 항생제 분석 방법: II. 액상 시료 전처리 방법)

  • Kim, Chansik;Ryu, Hong-Duck;Chung, Eu Gene;Kim, Yongseok;Rhew, Doug Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.6
    • /
    • pp.628-648
    • /
    • 2016
  • Increased attention has been paid to the presence of veterinary antibiotics in various environmental matrices due to their toxicological behavior in the ecosystem and development of antibiotic-resistant strains of pathogenic bacteria. In the this review, 37 target antimicrobials were selected based on annual sales of antibiotics for livestock in South Korea 2014. Also, extraction and clean-up methods for the determination of the antibiotic residues in liquid samples including water, milk, and honey were comprehensively reviewed in the literature. Solid-phase extraction (SPE) was commonly used as a pre-treatment method for the samples. Most of the analytes were extracted in acidic conditions (2.5~4.0) except for aminoglycosides, which were extracted in neutral conditions (7.0~8.0). ${\beta}-Lactams$ showed the highest recoveries in neutral pH due to their degradation characteristics in acidic media. Starta-X, Oasis HLB, and Oasis MCX were frequently applied as an SPE cartridge and Oasis HLB showed the highest recoveries for the majority of antibiotic classes. The homogenized honey and milk were extracted by mixing with acids for deproteinization. Solids and other interfering substances in the extract were eliminated by centrifugation followed by membrane filtration or SPE before injection into HPLC.

Determination of Veterinary Antibiotic Residues: III. Analytical Methods_A Review (시료 중 잔류 항생제 분석 방법: III. 기기 분석 방법)

  • Kim, Chansik;Ryu, Hong-Duck;Chung, Eu Gene;Kim, Yongseok;Rhew, Doug Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.6
    • /
    • pp.649-669
    • /
    • 2016
  • This study explored the analytical conditions for 21 veterinary antibiotics which have been popularly sold in South Korea in 2014 but have not yet been targeted in EPA method 1694. Most of the selected antibiotics were separated by a reverse-phase C18 column with a combination of (buffered) water and organic polar solvent, which was commonly methanol and acetonitrile in the gradient elution mode. Volatile additives such as formic acid, ammonium acetate and ammonium formate were usually added to the mobile phases to minimize asymmetrical and tailing of antibiotics' peaks and to increase their ionization in mass spectrometry. The analytical methods of aminoglycoside antibiotics were distinct from those of the other antibiotics in terms of adoption of ion-pair chromatography (IPC) and hydrophilic interaction liquid chromatography (HILIC) capable of retaining and separating extremely polar compounds due to their hydrophilicity. Trifluoroacetic acid or heptafluorobutyric acid was frequently added to the mobile phase as an ion-pair reagent for the IPC. Tandem mass spectrometry was numerously applied to the detection of antibiotics using positive electrospray ionization (ESI) and the selected reaction monitoring (SRM) mode. All reviewed analytical methods had been/were validated by evaluating recovery, limits of detection and quantification, decision limit or detection capability of the methods.

The Effect Factors on the Growth of Phytoplankton and the Sources of Organic Matters in Downstream of South-Han River (남한강 하류수역에서 식물플랑크톤 증식의 영향인자 및 수중유기를 기원)

  • Park, Hae-Kyung;Byeon, Myeong-Seop;Choi, Myeong-Jae;Kim, Young-Jin
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.5
    • /
    • pp.556-562
    • /
    • 2008
  • We divided the downstream of South-Han River into three water zones, such as river zone, transition zone and lacustrine zone depending on the flow rate, and elucidated the major effect factors on the growth of phytoplankton and the sources of organic matters in each water zone. The difference of chlorophyll-a concentration which represents the standing crop of phytoplankton was statistically significant among the water zones. From the results of bivariate correlation analysis between chlorophyll-a concentration and water quality parameters in each water zone, the outflow of Chungju dam and hydraulic retention time of Lake Paldang which are directly related with the flow rate seemed to have obvious impact on phytoplankton growth in the downstream of South-Han River. The concentration of nutrients such as phosphorus and nitrogen exceeded the criterion of eutrophication and did not showed significant relationship with chlorophyll-a concentration. There were strong correlations between $BOD_5$ and chlorophyll-a concentrations in transition and lacustrine zone showing autochthonous production of phytoplankton was dominant source of organic matters in these zones especially in dry seasons. The results of this study show that the control of abundance of phytoplankton is the key target for reduction of the organic pollution in the downstream of South-Han River.