• 제목/요약/키워드: voltage standard

검색결과 977건 처리시간 0.027초

Low-Swing 기술을 이용한 저 전력 병렬 곱셈기 설계 (Design of a Low-Power Parallel Multiplier Using Low-Swing Technique)

  • 강장희;김정범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 A
    • /
    • pp.79-82
    • /
    • 2003
  • This paper describes a new low-swing inverter for low power consumption. To reduce a power consumption, an output voltage swing is in the range from 0 to $V_{ref}-V_{TH}$, where $V_{ref}=V_{DD}-nV_{TH}$. This can be done by the inverter structure that allow a full swing or a swing on its input terminal without leakage current. Using this low-swing voltage technology, we propose a low-power $4\times4$ bit parallel multiplier. The proposed circuits are simulated with HSPICE under $0.35{\mu}m$ CMOS standard technology. Compare to the previous works, this circuit can reduce the power consumption rate of 11.2% and the power-delay product of 10.3%.

  • PDF

표준전압변성기 두 대를 이용한 전자식 전압변성기의 오차 평가 (Evaluation of Errors of Electronic Voltage Transformer using Two Standard Voltage Transformers)

  • 한상길;김윤형;정재갑;강전홍;이상화;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.64-66
    • /
    • 2008
  • 현재 전압변성기는 기존의 철심형 전압변성기에서 전자식전압변성기로 변화하고 있으며, 전자식 전압변성기의 비오차와 위상각 오차를 정확하게 평가하는 것은 전자식 전압변성기의 보급에 중요하다. 표준전압변성기 두 대와 전압변성기 비교기를 이용하여 22 kV급 전자식 전압변성기의 비오차와 위상각 오차를 평가할 수 있는 시스템을 구축하였으며, 시스템의 불확도를 분석하였다.

  • PDF

Design of a Digital PWM Controller for a Soft Switching SEPIC Converter

  • Nashed, Maged N.F.
    • Journal of Power Electronics
    • /
    • 제4권3호
    • /
    • pp.152-160
    • /
    • 2004
  • This paper presents analysis, modeling, and design of a low-harmonic, isolated, active-clamped SEPIC for future avionics applications. Simpler converter dynamics, high switching frequency, zero voltage-Transition-PWM switching, and a single-layer transformer construction result. This paper describes complete design of a digital controller for a high-frequency switching power supply. Guidelines for the minimum required resolution of the analog-to-digital converter, the pulse-width modulator, and the fixed-point computational unit is derived. A design example based on a SEPIC converter operating at the high switching frequency is presented. The controller design is based on direct digital design approach and standard root-locus techniques.

EVS(Electrochemical Volatage Spectroscopy)기법을 이용한 리튬이온배터리의 상온과 저온에서의 전기화학적 분석 (Electrochemical Analysis of Lithium-Ion Battery at Standard Temperature and Low temperature Using EVS(Electrochemical Voltage Spectroscopy))

  • 한동호;김종훈;이성준
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 추계학술대회
    • /
    • pp.159-160
    • /
    • 2017
  • 본 논문에서는 리튬배터리의 전기화학적 분석법으로 전기 화학적 전압 분광법(electrochemical voltage spectroscopy;EVS)을 사용하였다. 전기화학적 활성상태의 밀도를 직접 측정하는 기법으로 정전압(potentiostatic) 제어를 기반으로 한다. EVS 테스트에서 양전극의 전압은 각 단계가 전기화학적 평행상태에 도달할 때 까지 유지되며 이 방법은 배터리의 전기화학적 산화 환원 전위의 미세한 차이에 기초하여 활성 물질의 상태에 대한 정확한 정보를 얻을 수 있다.

  • PDF

산화물반도체 박막트랜지스터 제작 및 전기적 특성 분석 (Fabrication and Charaterization of Oxide Thin Film Transistor)

  • 이상렬
    • 한국전기전자재료학회논문지
    • /
    • 제26권4호
    • /
    • pp.275-277
    • /
    • 2013
  • Thin-film transistors(TFTs) with silicon zinc tin oxide(SZTO) channel layer are fabricated by solution-process. The threshold voltage ($V_{th}$) shifted toward positive directly with increasing Si contents in SZTO system. Because the Si has a lower standard electrode potential (SEP) than Sn, Zn, thus degenerate the oxygen vacancy (VO). As a result, the Si act as carrier suppressor and oxygen binder in the SZTO as well as a $V_{th}$ controller.

132 kV 초정밀 전압변성기(PT) 개발 및 안정도 평가 (Development of 132 kV Standard Potential Transformer and Stability Test)

  • 권성원;이상화;정재갑;김문석;김재영;이성하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1387_1388
    • /
    • 2009
  • High accurate and stable 132 kV potential transformers (PTs) including 66 kV & 22 kV PT with stability of less than 0.0033 % for 13 month and with ratio error within $\pm$ 0.024 % at full rated voltage have been developed. The PTs are useful as the reference PT of the PT comparator system in the voltage range of 11 kV to 132 kV PT.

  • PDF

Feasibility of Using the Clamp Meter in Measuring X-Ray Tube Current

  • Kim, Sung-Chul
    • International Journal of Contents
    • /
    • 제9권1호
    • /
    • pp.38-41
    • /
    • 2013
  • The clamp meter maintains electric safety as a non-invasive method while measuring the absolute value of tube current with it has been recently developed for an X-ray high-tension cable. Especially this can show high accuracy at short X-ray exposure time. Considering such a condition, this study is to evaluate the feasibility of a clamp meter in measuring X-ray tube current by taking the measurements and comparing with those of the Dynalyzer III which has been considered as a standard measuring device. From measuring the tube current accuracy depending on changes in tube voltage and exposure time, the clamp meter showed higher accuracy rate which was -1.3~4.2% difference. Thus clamp meter can be used for clinical radiologists who are not familiar electric circuit to manage X-ray devices easily and correctly in the future.

직류전원을 이용한 배전급 차단기의 등가 3상 합성투입시험법 (Equivalent three-phase synthetic making test for medium voltage circuit breaker of distribution system using DC power)

  • 박병락;조만영;김진석;신희상;김재철
    • 조명전기설비학회논문지
    • /
    • 제25권7호
    • /
    • pp.105-113
    • /
    • 2011
  • The study about three-phase synthetic making test using DC power has been performed in order to increase the making test capacity on Vacuum Circuit Breaker. And, it made possible to solve the limitations that short-circuit testing facilities can not fulfill the testing requirements of VCB exceeding three-phase 36[kV] 31.5[kA]. By using DC power and high speed spark-gap switch, this method made the equivalence with the pre-arc that occurred during the making process under the fault condition of power system. As results, KERI(Korea Electrotechnology Research Institute) could have capacity to carry out type test for VCB under three-phase 52[kV] 40[kV], which satisfies the IEC Standard.

A Series Arc Fault Detection Strategy for Single-Phase Boost PFC Rectifiers

  • Cho, Younghoon;Lim, Jongung;Seo, Hyunuk;Bang, Sun-Bae;Choe, Gyu-Ha
    • Journal of Power Electronics
    • /
    • 제15권6호
    • /
    • pp.1664-1672
    • /
    • 2015
  • This paper proposes a series arc fault detection algorithm which incorporates peak voltage and harmonic current detectors for single-phase boost power factor correction (PFC) rectifiers. The series arc fault model is also proposed to analyze the phenomenon of the arc fault and detection algorithm. For arc detection, the virtual dq transformation is utilized to detect the peak input voltage. In addition, multiple combinations of low- and high-pass filters are applied to extract the specific harmonic components which show the characteristics of the series arc fault conditions. The proposed model and the arc detection method are experimentally verified through a boost PFC rectifier prototype operating under the grid-tied condition with an artificial arc generator manufactured under the guidelines for the Underwriters Laboratories (UL) 1699 standard.

가공개폐기용 폴리머 부싱 개발 (Development of Polymer Bushing for Overhead Line Switch)

  • 최경선;주종민;이철호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.787-790
    • /
    • 2001
  • Polymer bushing used for overhead line switch was designed and investigated. Requirements of electrical ratings such as partial discharge, ac withstand voltage, impulse voltage and material properties were proposed in accordance with IEEE 386 and pre-standard (PS) 151-146∼147, 170∼180 of KEPCO. The polymer bushing consists of an internal epoxy bushing and external housing made of EPDM rubber. The rubber housing was molded with mold cone. Therefore, the polymer bushing offers several advantages like light weight, good sealing properties, easy installation and excellent performance in contamination. Electric field analysis was also introduced in order to verify the reliability of the design.

  • PDF