• 제목/요약/키워드: voltage standard

검색결과 977건 처리시간 0.028초

Wide Voltage Input Receiver with Hysteresis Characteristic to Reduce Input Signal Noise Effect

  • Biswas, Arnab Kumar
    • ETRI Journal
    • /
    • 제35권5호
    • /
    • pp.797-807
    • /
    • 2013
  • In this paper, an input receiver with a hysteresis characteristic that can work at voltage levels between 0.9 V and 5 V is proposed. The input receiver can be used as a wide voltage range Schmitt trigger also. At the same time, reliable circuit operation is ensured. According to the research findings, this is the first time a wide voltage range Schmitt trigger is being reported. The proposed circuit is compared with previously reported input receivers, and it is shown that the circuit has better noise immunity. The proposed input receiver ends the need for a separate Schmitt trigger and input buffer. The frequency of operation is also higher than that of the previously reported receiver. The circuit is simulated using HSPICE at 0.35-${\mu}m$ standard thin oxide technology. Monte Carlo analysis is conducted at different process conditions, showing that the proposed circuit works well for different process conditions at different voltage levels of operation. A noise impulse of ($V_{CC}/2$) magnitude is added to the input voltage to show that the receiver receives the correct logic level even in the presence of noise. Here, $V_{CC}$ is the fixed voltage supply of 3.3 V.

단상 센서리스 PFC 컨버터의 직류출력전압 제어에 관한 연구 (A Study on DC output voltage control of single-phase senseless PFC converter)

  • 문상필;강욱중;권순걸;서기영
    • 조명전기설비학회논문지
    • /
    • 제17권2호
    • /
    • pp.58-65
    • /
    • 2003
  • 일반적인 단상 PFC 컨버터는 직류전압을 일정한 기준값으로 제어할 수 있으나 시스템의 구성상 직류전압과 교류전압 및 전류등을 검출하여 제어하기 때문에 전체적으로 제어 시스템이 복잡하고, 가격이 비싸며, 신속성등의 문제점들이 대두되어지고 있다. 이러한 문제점들을 해결하기 위하여 본 논문에서는 센서리스 PFC 컨버터 회로를 제안하여 교류 전압파형 검출만으로 전체 시스템을 간단하게 제어하였다. 그리고 초퍼회로에서 제어된 전압량 Kd(Ed/Ea)에 의해서 직류출력전압을 직접적으로 제어하였으며, 직류출력전압의 변동율이 회로의 파라미터에 따른 변화의 특징에 대해서 서술하였다. 이러한 모든 사항아느 실험을 통하여 타당성을 증명하였다.

순간전압강하에 의한 단상 민감부하 및 삼상 유도전동기의 외란 민감도에 관한 연구 (A Study on the Susceptibility of Single-phase Sensitive Loads and the Three-phase Induction Motor by Voltage Sag)

  • 윤상윤;문종필;김재철;이희태
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권1호
    • /
    • pp.37-44
    • /
    • 2006
  • In this paper we explore the susceptibility of common sensitive loads by voltage sags of power distribution systems. The experimental approach was used for obtaining the susceptibility of single-phase loads and the three-phase induction motor. The experimental result of single-phase loads was transformed to the ITIC(Information of Technology Industry Council) format and used for evaluating the adverse impacts of a individual and repetitive sags using the performance contour of the foreign standard data. In order to assess the impact of voltage sags on three-phase induction motor, also, the experiment was peformed. The experiment was focused on the current, torque, and speed loss of the motor during a voltage sag. For comparing the impacts of individual and repetitive voltage sags, the variations of motor torque is focused among the experimental results. The sensitive curves of instantaneous current peak are used to describe the susceptibility of three-phase induction motor and 진so it were used for the quantitative analysis of the impact of three-phase induction motor due to voltage sags. Through the results of experiment, we verified that some types loads have more severe impact at repetitive voltage sags than individual ones and proposed method can be effectively used to evaluate the actual impact of voltage sags.

IT기반 분산전원 연계 배전계통의 최적전압조정에 관한 연구 (A study for IT Based Optimal Voltage Control Method of Distribution Systems with Distributed Generation)

  • 김정년;백영식;서규석
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권4호
    • /
    • pp.139-143
    • /
    • 2006
  • Recently, standard of living improved and Information-Communication industry developed rapidly. Thereby, interest about electric power quality is rising worldwide. So, research and Development to enhance electric power quality in various viewpoint until most suitable supply system from each kind device to improve electric power quality. And specially, interest about voltage quality is rising by diffusion increase of information communication appliance and minuteness control appliance etc. Also Power consumption is increasing, but expansion of large size generator by environmental and site security problem is difficult. So, introduction of distribution generation is investigated actively by electric-power industry reorganization. Voltage management of power system had been controlled by ULTC (Under Load Tap Changer) in substation and pole transformer on the high voltage distribution line. But, voltage control device on substation and distribution line is applied each other separatively. Therefore, efficiency of line voltage control equipment is dropping. Also, research about introduction upper limit of distribution generation is consisting continuously. This paper presents cooperation use way between voltage control device and introduction upper limit of distribution generation for most suitable voltage control in distribution power system.

불평등 전계에서 $SF_6/CF_4$ 혼합가스의 절연내력과 PD특성 (Breakdown Voltage and PD Characteristics of $SF_6/CF_4$ Mixtures in Nonuniform Field)

  • 황청호;성허경;허창수
    • 전기학회논문지
    • /
    • 제57권4호
    • /
    • pp.635-640
    • /
    • 2008
  • New gas mixtures are now finding applications such as interrupting media for high-voltage circuit breakers. These mixtures consist of a high content of carbon tetrafluoride($CF_4$) added to sulfur hexafluoride($SF_6$). Nowdays $SF_6$ has been established for the use in gas insulated substations due to its high insulation withstand level and good arc quenching capability. At this paper Breakdown characteristics were investigated for $SF_6/CF_4$ mixtures when AC voltage and standard lightning impulse voltage(LI) was applied in a needle-plane electrodes. And partial discharge(PD) experiments were carried out in the test chamber which was made in needle-plane electrode. And ${\Phi}$-Q-N distribution of partial discharge signals was analyzed. The total pressure of the $SF_6/CF_4$ mixtures was varied within the range of 0.1-0.5 Mpa in the test chamber. The breakdown voltage in needle-plane electrode displayed N shape characteristics for increasing the content of $SF_6$ at positive impulse voltage and the PD inception voltage was increased slightly when pressure of $SF_6/CF_4$ Mixtures was increased. Maximum PD inception voltage is showed in 80% SF6/20%$CF_4$.

고전압 펄스신호 측정용 분압기의 온도보상에 관한 실험 (Experimental Analysis on Temperature Compensation of Capacitive Voltage Divider for a Pulsed High Voltage Measurement)

  • 장성덕;손윤규;권세진;오종석;조무현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1530-1533
    • /
    • 2005
  • Total 12 units of high power klystron-modulator systems as microwave source is under operation for 2.5-GeV electron linear accelerator in Pohang Light Source(PLS) linac. RF power and beam power of klystron are precisely measured for the effective control of electron beam. A precise measurement and measurement equipment with good response characteristics are required for this. Input power of klystron is calculated from the applied voltage and the current on its cathode. Tiny measurement error severely effects RF output power value of klystron. Therefore, special care is needed to measure precise beam voltage. Capacitive voltage divider(CVD) unit is intended for the measurement of beam voltage of 400 kV generated from the pulsed klystron-modulator system. Main parameter to determine the standard capacitance in the high arm of CVD is dielectric constant of insulation oil. Therefore CVD should be designed to have a minimum capacitance variation due to voltage, frequency and temperature in the measurement range. This paper will discuss the analysis of capacitive voltage divider for a pulsed high-voltage measurement, and the empirical relations between capacitance and oil temperature variation.

  • PDF

Multi Channel LED 조명 Module 구동에서 최대 효율을 위한 최대 Channel 전압 감지회로 (Feedback Circuit of Maximum LED Channel String Voltage Detection Converter for Energy Saving on Multichannel LED Module)

  • 김현식;김기원;김기훈;김유신;송상빈
    • 한국전기전자재료학회논문지
    • /
    • 제25권11호
    • /
    • pp.938-941
    • /
    • 2012
  • LED is divided to multichannel in order not to exceed a certain voltage in aspects of electric standard. However, it's not possible to know in accordance with what channel SMPS controls the constant voltage and current. In order to solve this problem, it needs to detect the maximum LED String voltage which is applied to LED control circuit, and it is possible to minimize the voltage drop when a difference of LED string voltage occurs by each channel if LED is controlled by the maximum LED string voltage detected. In addition, it is also possible to maximize the efficiency of LED if change LED voltage by detecting the maximum voltage. Feasibility of this claim was verified through implementation of the circuit.

3- Transistor Cell OTP ROM Array Using Standard CMOS Gate-Oxide Antifuse

  • Kim, Jin-Bong;Lee, Kwy-Ro
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제3권4호
    • /
    • pp.205-210
    • /
    • 2003
  • A 3-Transistor cell CMOS OTP ROM array using standard CMOS antifuse (AF) based on permanent breakdown of MOSFET gate oxide is proposed, fabricated and characterized. The proposed 3-T OTP cell for ROM array is composed of an nMOS AF, a high voltage (HV) blocking nMOS, and cell access transistor, all compatible with standard CMOS technology. The experimental results show that the proposed structure can be a viable technology option as a high density OTP ROM array for modern digital as well as analog circuits.

Standard와 MAR 알고리즘에서 CT 검사조건 변화에 따른 인공물과 노이즈 평가 (Evaluation of Artifact and Noise in the Standard and MAR Algorithms with Variation of Examination Conditions of CT)

  • 김영근;양숙;왕태욱
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권2호
    • /
    • pp.79-85
    • /
    • 2020
  • The influence of metal artifact in CT image depends on the type of metal materialsm, the reconstruction algorithm, and scan parameters. The presence of metal artifacts was quantitatively evaluated by applying the standard and MAR algorithms through the phantom study. In the change of tube voltage applied the standard algorithm, metal artifact decreased to 44.9% for 80 vs 120 kVp, 24% for 100 vs 120 kVp, while the image taken at 140 kVp increased the artifact by 19% compared to 120 kVp. When the tube current was increased from 100 to 300 mA, there was no significant difference in the CT value and noise. Black band and white strike artifacts occurred up to 65.9% in the adjacent ROI of the metal driver, whereas titanium screw produced lesser metal artifact than that of the metal driver. The combination of 120kVp or higher tube voltage-standard algorithm was effective in removing black band artifacts as well as white streak by high density materials. However, MAR reconstruction algorithm was useful in improving image quality under the environment of low kVp and high density materials, without increase of radiation exposure.