• Title/Summary/Keyword: voltage island

Search Result 91, Processing Time 0.03 seconds

Double-tuned Filter Design For HVDC System (HVDC System 적용 Double-tuned 필터의 설계 방법 연구)

  • Lee, Hee-Jin;Nam, Tae-Sik;Son, Gum-Tae;Park, Jung-Wook;Chung, Yong-Ho;Lee, Uk-Hwa;Baek, Seung-Taek;Hur, Kyeon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.9
    • /
    • pp.1232-1241
    • /
    • 2012
  • The ac side current of an high voltage direct current (HVDC) converter is characterized by highly non-sinusoidal waveform. If the harmonic current is allowed to flow in the connected ac system, it may cause unacceptable levels of distortion. Therefore, ac side filters are required as part of the total HVDC converter station, in order to reduce the harmonic distortion of the ac side current and voltage to acceptably low levels. The ac side filters are also employed to compensate network requested reactive power because HVDC converters also consume substantial reactive power. Among different types of filters, double-tuned filters have been widely utilized for HVDC system. This paper presents two design methods of double-tuned filter; equivalent method and parametric method. Using a parametric method, in particular the paper proposes a new design algorithm for a realistic system. Finally, the performance of the design algorithm is evaluated for a 80kV HVDC system in Jeju island with PSCAD/EMTDC program. The results cleary demonstrate the effectiveness of proposed design method in harmonics elimination and steady-state stability.

Cost-Aware Scheduling of Computation-Intensive Tasks on Multi-Core Server

  • Ding, Youwei;Liu, Liang;Hu, Kongfa;Dai, Caiyan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.11
    • /
    • pp.5465-5480
    • /
    • 2018
  • Energy-efficient task scheduling on multi-core server is a fundamental issue in green cloud computing. Multi-core processors are widely used in mobile devices, personal computers, and servers. Existing energy efficient task scheduling methods chiefly focus on reducing the energy consumption of the processor itself, and assume that the cores of the processor are controlled independently. However, the cores of some processors in the market are divided into several voltage islands, in each of which the cores must operate on the same status, and the cost of the server includes not only energy cost of the processor but also the energy of other components of the server and the cost of user waiting time. In this paper, we propose a cost-aware scheduling algorithm ICAS for computation intensive tasks on multi-core server. Tasks are first allocated to cores, and optimal frequency of each core is computed, and the frequency of each voltage island is finally determined. The experiments' results show the cost of ICAS is much lower than the existing method.

The Effect of HVDC#3 on Jeju Power System (제주 HVDC#3 영향 분석)

  • Park, Jung-Soo;Jung, Hong-Ju;Han, Young-Seong;Kim, Rae-Young;Chung, Chung-Choo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.12
    • /
    • pp.2196-2201
    • /
    • 2011
  • According to the 5th national plan for electric power demand and supply, the 3rd HVDC link will be installed between KEPCO and Jeju Island system and go into operation in June, 2016. However, if it adopt LCC HVDC, Jeju power system could be in voltage instable condition. In order to solve the problem, we propose the application of VSC HVDC to the 3rd HVDC project. In the past, VSC HVDC has many disadvantages such as, inefficiency in conversion, size limit, and expensiveness, compared to LCC HVDC. Recently, the new technologies and the demand for renewable energy interconnection are leading a large growth in VSC HVDC market. In this paper, we will introduce the technical and market trends of VSC HVDC and power system stability analysis results for Jeju power system having LCC and VSC HVDCs.

Fabrication of the Recrystallized Poly Silicon nMOSFET and Its Electrical Characteristics (재결정화된 다결정 nMOSFET의 제작 및 그 전기적 특성)

  • Kim, Joo-Young;Kang, Moun-Sang;Kim, Gi-Hong;Ku, Yong-Seo;An, Chul
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.29A no.11
    • /
    • pp.91-96
    • /
    • 1992
  • The technology of LOCOS(LOCal Oxidation of Silicon) was used to form the island of SOI film. After this, the SOI film was recrystallized by CO$_2$ laser and metal gate nMOSFETs were fabricated on this SOI film and their electrical characteristics were measured. The kink effect was not nearly observed and edge channel effect was found in the SOI nMOSFETs. The threshold voltage was about 0.5V, the electron mobility was about 340cm$^2$V$\cdot$S and an ON/OFF ratio above 10$^{5}$ was obtained at V_{DS}$=4V. The electrical characteristics were improved by laser recrystallization.

  • PDF

Performance Test of Automatic Voltage Regulator for Diesel Generator in Island (도서지역 디젤발전기 자동전압제어시스템 성능시험)

  • Lee, Uitaek;Ryu, Hoseon;Moon, Jooyoung;Park, Manki
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.443-444
    • /
    • 2016
  • 본 논문에서는 도서지역 디젤발전기 자동전압제어시스템을 개발하고 국내 다수의 도서지역에 적용하여 시험한 결과와 설계 내용에 대해 기술하였다. 기존 외산제품에서 별도의 하드웨어를 통해 수행하던 회전형 다이오드 진단기능을 소프트웨어적으로 구현하여 제어기 내에 통합하였으며, 자동으로 계통전압을 추종하는 기능을 추가하는 등 도서지역의 특성을 분석하고 그에 맞는 기능들을 새로 추가 적용하였다.

  • PDF

Development of a New Islanding Detection Method for Distributed Resources (분산 전원의 고립 운전 검출 기법의 개발)

  • Jang, Seong-Il;Kim, Gwang-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.11
    • /
    • pp.506-513
    • /
    • 2001
  • The islanding detection for distributed resources (DR) becomes an important and emerging issue in power system protection since the distributed generator installations are rapidly increasing and most of the installed systems are interconnected with distribution network. In order to avoid the negative impacts from islanding operations of DR on protection, operation and management of distribution system, it is necessary to effectively detect the islanding operations of DR and rapidly disconnect it from distribution network. Generally, it is difficult to detect islanding operation by monitoring only one system parameter This paper presents a new logic based islanding detection method for distributed resources(DR) which are interconnected with distribution network. The proposed method detects the islanding operation by monitoring four system parameter: voltage variation, phase displacement, frequency variation, and the variation of total harmonic distortion(THD) of current; therefore, it effectively detects island operation of DR unit operating in parallel with the distribution network. We also verified the efficiency of the proposed algorithm using the radial distribution network of IEEE 34 bus model.

  • PDF

Development of a Islanding Protection Algorithm for Distributed Resources (분산 전원의 고립 운전 진단 알고리즘 개발)

  • Jang, S.I.;Park, J.Y.;Kim, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1287-1289
    • /
    • 2001
  • This paper presents the logic based islanding protection algorithm for distributed resources(DR) which are interconnected with distribution network. Due to the negative impacts from islanding operations of DR on protection, operation and management of distribution system, it is necessary to effectively detect the islanding operations of DR and disconnect it from distribution network rapidly. Generally, it is difficult to detect islanding operation by monitoring only one system parameter. The proposed islanding protection algorithm utilizes multi-criteria, voltage variation, phase displacement frequency variation, the variation of total harmonic distortion(THD) of current; therefore it effectively detects island operation of DR unit. We also verified the efficiency of the proposed algorithm using the radial distribution network of IEEE 34 bus model.

  • PDF

UPFC Performance Control in Distribution Networks for DG Sources in the Islanding

  • Fandawi, Ahmed;Nazarpour, Daryoosh
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.5
    • /
    • pp.303-309
    • /
    • 2017
  • The flexible AC transmission system (FACTS) provides a new advanced technology solution to improve the flexibility, controllability, and stability of a power system. The unified power flow controller (UPFC) is outstanding for regulating power flow in the FACTS; it can control the real power, reactive power, and node voltage of distribution networks. This paper investigates the performance of the UPFC for power flow control with a series of step changes in rapid succession in a power system steady state and the response of the UPFC to distribution network faults and islanding mode. Simulation was carried out using the MATLAB's simulink sim power systems toolbox. The results, which were carried out on a 5-bus test system and a 4-bus multi-machine electric power system, show clearly the effectiveness and viability of UPFC in rapid response and independent control of the real and reactive power flows and oscillation damping [6].

A sensitivity analysis about reactive power according to the interconnection distance of wave-offshore hybrid generation system (복합발전 계통연계 시 보상장치 필요성 분석을 위한 거리에 따른 무효전력 민감성 분석)

  • Jung, Seungmin;Yoo, Yeuntae;Song, Sungyoon;Jang, Gilsoo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.251-252
    • /
    • 2015
  • The designed hybrid generation system (HGS) not only consider the voltage condition of grid connection point but also do reactive power support according to the transmission system operator's directions. The PCS operation plan in HGS should be supported by precise transferred quantity expectation about reactive power because the system has large physical areas and also be interconnected with grid through long transmission system. Therefore, the realistic measuring process about transferred reactive power quantity by utilizing HGS is required to consider additional compensation plan. In this paper, an reactive power transferred capability of HGS with expected parameter is analyzed, and imposed to the simulation process that is performed on EMTDC environment. Basically, grid information and system characteristics were utilized with Jeju island in Korea, and the performance analysis is carried out based on the composed layout in ongoing project.

  • PDF

Fabrication and Characterizations of Stretchable Thin-Film Transistor using Parylene Gate Insulating Layer (파릴렌 게이트 절연층을 사용한 신축성 박박 트랜지스터의 제작 및 특성)

  • Jung, Soon-Won;Ryu, Bong-Jo;Koo, Kyung-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.4
    • /
    • pp.721-726
    • /
    • 2017
  • We fabricated stretchable thin-film transistors(TFTs) on a polydimethylsiloxane substrate with patterned polyimide island structures by using an amorphous InGaZnO semiconductor and parylene gate insulator. The TFTs exhibited a field- effect mobility of $5cm^2V^{-1}s^{-1}$ and a current on/off ratio of $10^5$ at a relatively low operating voltage. Furthermore, the fabricated transistors showed no noticeable changes in their electrical performance for large strains of up to 50 %.