• 제목/요약/키워드: vertical sizes

검색결과 186건 처리시간 0.027초

암석시편의 균열조사를 위한 탄성파 주시 및 진폭 변화에 관한 연구 (Study of seismic traveltime and amplitude effect to detect to detect cracks in rock)

  • 서백수;백환조;민경원
    • 터널과지하공간
    • /
    • 제6권3호
    • /
    • pp.239-244
    • /
    • 1996
  • Cracks have influence on the physical and mechanical and, more importantly, on the engineering properties of the rock. Physical properties including the volumetric deformation coefficient, electrical resistivity, seismic wave velocity, and the mechanical properties such as the elastic constants and strength of rock are affected significantly by the presence of cracks of various sizes. An experimental program was undertaken to investigate the effect of a finite line crack on the diffraction of the plane compressional wave. Horizontal and vertical components of displacement and acceleration curve were obtained using a single-source and multi-receivers system. A theoretical model from numerical analysis implementing the finite element method was compared with the measured data.

  • PDF

능동 진동제어용 전자기 액츄에이터 설계 (A Design of Electromagnet Actuator for Active Vibration Control)

  • 이주훈;전정우;황돈하;강동식;최영규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.522-524
    • /
    • 2005
  • In this paper, we address an actuator system, which suppresses the micro-vibration engaged by environment. The actuator system consists of two modules with a permanent and an electromagnet. In vertical mode, one module is upper the other is lower. For optimal control of alternating vibration, the rate of the attraction force and the repulsion force is exactly one. Generally, the repulsive force is smaller than the attractive force. For linear control of engaged vibration, the ratio of repulsive force and attractive force is designed to equal. The actuator system will be applied to an active vibration control system for precise vibration suppression. In this paper, the actuator structure and its important sizes are calculated by RMS and FEM analysis.

  • PDF

Pool Boiling Heat Transfer in Annuli with Closed Bottom

  • Kang, Myeong-Gie;Han, Young-Hwan
    • Nuclear Engineering and Technology
    • /
    • 제34권2호
    • /
    • pp.165-175
    • /
    • 2002
  • Effects of gap sizes (3.9-44.3 mm) of vertical annuli on nucleate pool boiling heat transfer of water at atmospheric pressure have been obtained experimentally. Through the study, tubes of the closed bottom have been investigated and results are compared with those of a single unconfined tube. According to the results, the annular condition gives much increase in heat transfer coefficient at moderate heat fluxes. The increase is much enhanced 3s the gap size decreases. At the same tube wall superheat (about 3.1 K) the heat transfer coefficient for the least gap size (i.e., 3.9 mm) is more than three times greater than that of the unconfined tube. However, deterioration of heat transfer occurs at high heat flux for confined boiling.

A robust identification of single crack location and size only based on pulsations of the cracked system

  • Sinou, Jean-Jacques
    • Structural Engineering and Mechanics
    • /
    • 제25권6호
    • /
    • pp.691-716
    • /
    • 2007
  • The purpose of the present work is to establish a method for predicting the location and depth of a crack in a circular cross section beam by only considering the frequencies of the cracked beam. An accurate knowledge of the material properties is not required. The crack location and size is identified by finding the point of intersection of pulsation ratio contour lines of lower vertical and horizontal modes. This process is presented and numerically validated in the case of a simply supported beam with various crack locations and sizes. If the beam has structural symmetry, the identification of crack location is performed by adding an off-center placed mass to the simply supported beam. In order to avoid worse diagnostic, it was demonstrated that a robust identification of crack size and location is possible if two tests are undertaken by adding the mass at the left and then right end of the simply supported beam. Finally, the pulsation ratio contour lines method is generalized in order to be extended to the case of rectangular cross section beams or more complex structures.

메카넘 휠을 이용한 배관 로봇의 개발에 관한 연구 (Development of Pipe Robot by Using Mecanum Wheels)

  • 김대영;박순욱;이호중;김종필;정원지;곽도훈
    • 한국기계가공학회지
    • /
    • 제20권2호
    • /
    • pp.58-65
    • /
    • 2021
  • Most pipe-inspection robots have fixed sizes and use a wired cable system. Pipelines are generally composed of various structures, including bent pipes, vertical pipes, branch pipes, and holes, and it is difficult to explore the insides of such modular piping structures. In an offshore plant pipeline, a robot that can pass through the pipe hole in the downward direction or avoid obstacles, such as a measuring instruments, has not been introduced yet. In this study, an inspection robot that can travel through most pipelines in offshore plants is proposed. This robot uses mecanum wheels; upward, downward, and rotary motion; and a novel rotatable mechanism. Moreover, the robot is designed to be compact and lightweight to include additional devices in the middle.

스마트 폰 터치스크린에서의 작은 터치 키의 사용성 연구 (Usability Evaluation of the Size of Small Touch Keys for the Smart Phone)

  • 김보람;김태일;임영재;정의승
    • 대한산업공학회지
    • /
    • 제38권2호
    • /
    • pp.80-88
    • /
    • 2012
  • This paper focuses on small touch key size and spacing that affect the usability of the smart phones. The experiments examined thirty-six different touch key designs, combinations of four touch key sizes (width (mm) ${\times}$height (mm); $4{\times}4$, $4{\times}7$, $7{\times}4$, and $7{\times}7$), and nine spacings (horizontal (mm)${\times}$vertical (mm); $0{\times}0$, $0{\times}1$, $0{\times}3$, $1{\times}0$, $1{\times}1$, $1{\times}3$, $3{\times}0$, $3{\times}1$, and $3{\times}3$). Forty participants volunteered in the experiment. The completion time, error rate, identification discomfort, and control discomfort were measured. The results revealed that the touch key sizes of $7{\times}7$ and $7{\times}4$ provide the best performance in terms of the error rate measure, while the touch key size of $7{\times}7$ provides the best results for other measures. In addition, touch key spacings of $1{\times}1$, $1{\times}3$ and $3{\times}1$ are regarded as the best for all the measures. The results of this study suggest a practical approach for the small touch key design for the smart phones.

적운 모수화 방안이 고해상도 집중호우 예측에 미치는 영향 (Impact of Cumulus Parameterization Schemes with Different Horizontal Grid Sizes on Prediction of Heavy Rainfall)

  • 이재복;이동규
    • 대기
    • /
    • 제21권4호
    • /
    • pp.391-404
    • /
    • 2011
  • This study investigates the impact of cumulus parameterization scheme (CPS) with different horizontal grid sizes on the simulation of the local heavy rainfall case over the Korean Peninsula. The Weather Research and Forecasting (WRF)-based real-time forecast system of the Joint Center for High-impact Weather and Climate Research (JHWC) is used. Three CPSs are used for sensitivity experiments: the BMJ (Betts-Miller-Janjic), GD (Grell-Devenyi ensemble), and KF (Kain-Fritsch) CPSs. The heavy rainfall case selected in this study is characterized by low-level jet and low-level transport of warm and moist air. In 27-km simulations (DM1), simulated precipitation is overestimated in the experiment with BMJ scheme, and it is underestimated with GD scheme. The experiment with KF scheme shows well-developed precipitation cells in the southern and the central region of the Korean Peninsula, which are similar to the observations. All schemes show wet bias and cold bias in the lower troposphere. The simulated rainfall in 27-km horizontal resolution has influence on rainfall forecast in 9-km horizontal resolution, so the statements on 27-km horizontal resolution can be applied to 9-km horizontal resolution. In the sensitivity experiments of CPS for DM3 (3-km resolution), the experiment with BMJ scheme shows better heavy rainfall forecast than the other experiments. The experiments with CPS in 3-km horizontal resolution improve rainfall forecasts compared to the experiments without CPS, especially in rainfall distribution. The experiments with CPS show lower LCL(Lifted Condensation Level) than those without CPS at the maximum rainfall point, and weaker vertical velocity is simulated in the experiments with CPS compared to the experiments without CPS. It means that CPS suppresses convective instability and influences mainly convective rainfall. Consequently, heavy rainfall simulation with BMJ CPS is better than the other CPSs, and even in 3-km horizontal resolution, CPS should be applied to control convective instability. This conclusion can be generalized by conducting more experiments for a variety of cases over the Korean Peninsula.

학령후기 남아의 체형분석에 따른 길(Bodice) 원형에 관한 연구(제1보) (A Study on the Basic Bodice Pattern of the Upper Class Boys in Elementary School Based on the Somatotype Analysis(Part I))

  • 이경남;함옥상
    • 한국의류학회지
    • /
    • 제26권6호
    • /
    • pp.901-910
    • /
    • 2002
  • This study is to classify somatotypes of the upper class boys in elementary school. The study is conducted through anthoropometric measurements and photometric measurements. The subjects are 320 boys in the age group of 10 to 11 years old. The following conclusions are drawn from this study. 1. The height items are increased along with age increase. The increases in the factors, which specify vertical sizes such as height and length, are a little larger than those of breadth, depth, and girth, which specify ; horizontal sizes. 2. The factor analysis on anthropometric measurements and photometric measurements reveals five somatic composition factors and those factors comprised 79.60% of total variance. 3. The torso shapes of the upper class boys in elementary school are classified into three categories. The first type is taller and heavier than the average elementary school upper class boys and has the highest rising shoulders. The shape of the back is about average and the chest is developed above average. The curvature of the lower back is gentle and lower abdomen protrudes the most of the three types. The second type is tall and slightly heavier than average and shoulders are raised a little. The shoulder blades protrude about average and the curvature of lower back is the most developed of all. The cheat is developed about average and the abdomen is a little protruding. The third type is the most common with the smallest height of the three and skinny with dropped shoulders. The chest is somewhat flat and the shoulder blades protrude about average.

사이즈 적합성과 효율성이 향상된 야구 다리보호대 개발을 위한 그레이딩 편차 선정 (Selection of Grading Deviations to Develop Improved Baseball Leg Guards for Size Suitability and Efficiency)

  • 이효정;엄란이;이예진
    • 한국의류학회지
    • /
    • 제41권1호
    • /
    • pp.184-195
    • /
    • 2017
  • Baseball is a life sport that gives vitality to people. However, currently available leg guards do not have a variety of sizes and it is very difficult to purchase a leg guard that is suitable for the size of a specific consumer. Therefore, this study investigated the size system of a leg guard sold in the market and suggested a grading deviation suitable for the legs of Korean males. The results of the study were as follows. First, most brands were sold only in three size systems as children's, teenagers, and adults. Adult size systems were not subdivided. Second, Korean male legs were classified into Group 1 (large girth and height and lower body muscle) and Group 2 (small girth and height and low underbody muscle). Third, the size system is based on vertical items such as height and mid-thigh circumference. Each group produced 10 sizes. The smallest height or the largest height was also found to be about 4.5 to 5.0cm smaller or larger than the sample size for each group. The total length of the leg guard was about 2.5cm when the height was increased or decreased by one size. It was confirmed that the deviation of the circumference of the mid-thigh should be about 2.0cm larger or smaller than the sample size even if the height is the same. The deviation of the knee circumference and ankle circumference was smaller than the other circumference. In conclusion, the dimension combinations of the leg guard must be set differently to provide a leg guard with high size suitability according to leg type.

Effect of the Plasma-assisted Patterning of the Organic Layers on the Performance of Organic Light-emitting Diodes

  • Hong, Yong-Taek;Yang, Ji-Hoon;Kwak, Jeong-Hun;Lee, Chang-Hee
    • Journal of Information Display
    • /
    • 제10권3호
    • /
    • pp.111-116
    • /
    • 2009
  • In this paper, a plasma-assisted patterning method for the organic layers of organic light-emitting diodes (OLEDs) and its effect on the OLED performances are reported. Oxygen plasma was used to etch the organic layers, using the top electrode consisting of lithium fluoride and aluminum as an etching mask. Although the current flow at low voltages increased for the etched OLEDs, there was no significant degradation of the OLED efficiency and lifetime in comparison with the conventional OLEDs. Therefore, this method can be used to reduce the ohmic voltage drop along the common top electrodes by connecting the top electrode with highly conductive bus lines after the common organic layers on the bus lines are etched by plasma. To further analyze the current increase at low voltages, the plasma patterning effect on the OLED performance was investigated by changing the device sizes, especially in one direction, and by changing the etching depth in the vertical direction of the device. It was found that the current flow increase at low voltages was not proportional to the device sizes, indicating that the current flow increase does not come from the leakage current along the etched sides. In the etching depth experiment, the current flow at low voltages did not increase when the etching process was stopped in the middle of the hole transport layer. This means that the current flow increase at low voltages is closely related to the modification of the hole injection layer, and thus, to the modification of the interface between the hole injection layer and the bottom electrode.