Pool Boiling Heat Transfer in Annuli with Closed Bottom

  • Published : 2002.04.01

Abstract

Effects of gap sizes (3.9-44.3 mm) of vertical annuli on nucleate pool boiling heat transfer of water at atmospheric pressure have been obtained experimentally. Through the study, tubes of the closed bottom have been investigated and results are compared with those of a single unconfined tube. According to the results, the annular condition gives much increase in heat transfer coefficient at moderate heat fluxes. The increase is much enhanced 3s the gap size decreases. At the same tube wall superheat (about 3.1 K) the heat transfer coefficient for the least gap size (i.e., 3.9 mm) is more than three times greater than that of the unconfined tube. However, deterioration of heat transfer occurs at high heat flux for confined boiling.

Keywords

References

  1. M. H. Chun, M. G. Kang, 'Effects of heat exchanger tube parameters on nucleate pool boiling heat transfer,' ASME J. Heat Transfer, 120, 468 (1998)
  2. M. M. Corletti and L. E.Hochreiter, 'Advanced light water reactor passive residual heat removal heat exchanger test,' Proceedings of the 1st JSME/ASME Joint International Conference on Nuclear Engine Engineering, Tokyo, Japan, 381, (1991)
  3. M. G. Kang, 'Experimental investigation of tube length effect on nucleate pool boiling heat transfer,' Annals of Nuclear Energy 25 (4-5), 295 (1998) https://doi.org/10.1016/S0306-4549(97)00056-X
  4. M. G. Kang, 'An experimental parametric study of heat exchanger design under pool boiling condition for application to PRHRS of AP600,' Ph.D. dissertation, KAIST. (1996)
  5. K. E. Gungor and H. S. Winterton, 'A general correlation for flow boiling in tubes and annuli,' Int. J. Heat Mass Transfer 29 (3), 351 (1986) https://doi.org/10.1016/0017-9310(86)90205-X
  6. Z. Liu and R. H. S.Winterton, 'A general correlation for saturated and subcooled flow boiling in tubes and annuli, based on a nucleate pool boiling equation,' Int. J. Heat Mass Transfer 34(11), 2759 (1991) https://doi.org/10.1016/0017-9310(91)90234-6
  7. G. Sun and G. F. Hewitt, 'Experimental studies on heat transfer in annular flow,' Proceedings of the 2nd European Thermal-Sciences and 14th UIT National Heat Transfer Conference, 1345 (1996)
  8. S. C. Yao and Y.Chang, 'Pool boiling heat transfer in a confined space,' Int. J. Heat Mass Transfer 26, 841-848 (1983)
  9. Y. H. Hung and S. C. Yao, 'Pool boiling heat transfer in narrow horizontal annular crevices,' ASME J. Heat Transfer 107, 656 (1985)
  10. M. G. Kang, 'Nucleate pool boiling heat transfer in vertical annuli,' Transactions of the KSME B 25 (8), 1113 (2001)
  11. J. Bonjour and M. Lallemand, 'Flow patterns during boiling in a narrow space between two vertical surfaces,' Int. J. Multiphase Flow 24, 947 91998) https://doi.org/10.1016/S0301-9322(98)00017-2
  12. Y. Fujita, H. Ohta, S. Uchida, and K. Nishikawa, 'Nucleate boiling heat transfer and critical heat flux in narrow space between rectangular spaces,' Int. J. Heat Mass Transfer 31, 229 (1998)
  13. M. G. Kang, 'Hysteresis effects in pool boiling of water,' Transactions of the KSME B 25(8), 1037 (2001)