• Title/Summary/Keyword: vertical current structure

Search Result 215, Processing Time 0.026 seconds

Variation of Current by the Building of Artificial Upwelling Structure(II) (인공용승구조물 설치에 의한 유동변화(II))

  • Hwang, Suk-Bum;Kim, Dong-Sun;Bae, Sang-Wan;Kheawwongjan, Apitha
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2007.11a
    • /
    • pp.9-14
    • /
    • 2007
  • To illusσ'ate the variation of current around artificial upwelling structure which is located in the South sea of Korea, current measurements using ADCP (Acoustic Doppler Current Profiler) during neap and spring tides were carried out on 27th July(summer), 14th October and 30th November(Autumn), 2006. Current after the set up of artificial upwelling structure were shown different in the upper and lower layer, the boundary between the upper and lower layer was at $27{\sim}30m$ depth in summer. And the boundary layer was formed structure of three layer in Autumn. Upwelling and downwelling flow were occurred around the seamount, and these vertical flows were connected from surface to bottom The distribution of vertical shear and relative vorticity support the vertical flow around the seamount. The strength of vertical shear was higher and the direction of relative vorticity was anticlockwise (+) around the upwelling area.

  • PDF

Depleted Optical Thyristor using Vertical-Injection Structure for High Isolation Between Input and Output (완전공핍 광 싸이리스터에서 입출력의 높은 아이솔레이션을 위한 수직 입사형 구조에 관한 연구)

  • Choi Woon-Kyung;Kim Doo-Gun;Moon Yon-Tae;Kim Do-Gyun;Choi Young-Wan
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.1
    • /
    • pp.30-34
    • /
    • 2005
  • This study shows the lasing characteristics of InGaAs/InGaAsP multiple-quantum-well waveguide-type depleted optical thyristor (DOT) using the vertical window. The measured switching voltage and current are 3.36 V and 10 ㎂, respectively. The lasing threshold current is 131 mA at 25 ℃. The output peak wavelength is 1570 nm at a bias current of 1.22 Ith and there is not input signal anymore in the output port. The vertical injection depleted optical thyristor - laser diode (VIDOT-LD) using the vertical-injection structure shows very good isolation between input and output signal.

Casting Lowered-ADCP and Data Processing Methods for Configuring Vertical Current Structure (해류 수직구조를 파악하기 위한 LADCP Casting 및 자료처리 방법)

  • Kim, Eung;Jeon, Dong-Chull;Shin, Chang-Woong;Kim, Dong-Guk
    • Ocean and Polar Research
    • /
    • v.33 no.spc3
    • /
    • pp.397-407
    • /
    • 2011
  • To understand the vertical structure of ocean currents from raw data observed by lowered-ADCP (LADCP), these data require post-processing. Data were processed using Krahman's version 10.8 processing software based on Matlab. It is estimated the influence of auxiliary data affecting the processed current structure. The bottom-tracked velocities and the GPS information significantly contribute the offset on reference velocities in the bottom layer and barotropic ones in the middle layer, respectively. Good quality data can be obtained when LADCP is least tilted in pitch and roll during observation. In situ application of LADCP to the (northward) volume transports of Kuroshio in the East China Sea proved to be 24.8. Sv (= $1{\times}10^6m^3s^{-1}$) in October 2007, and 28.2 Sv in June 2008, respectively. The volume transport is relatively large over the continental slope when compared to the shelf or the deep sea.

Parasitic Inductance Reduction Design Method of Vertical Lattice Loop Structure for Stable Driving of GaN HEMT (GaN HEMT의 안정적 구동을 위한 수직 격자 루프 구조의 기생 인덕턴스 저감 설계 기법)

  • Yang, Si-Seok;Soh, Jae-Hwan;Min, Sung-Soo;Kim, Rae-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.3
    • /
    • pp.195-203
    • /
    • 2020
  • This paper presents a parasitic inductance reduction design method for the stable driving of GaN HEMT. To reduce the parasitic inductance, we propose a vertical lattice loop structure with multiple loops that is not affected by the GaN HEMT package. The proposed vertical lattice loop structure selects the reference loop and designs the same loop as the reference loop by layering. The design reverses the current direction of adjacent current paths, increasing magnetic flux cancellation to reduce parasitic inductance. In this study, we validate the effectiveness of the parasitic inductance reduction method of the proposed vertical lattice loop structure.

A Study on the Characteristics of the Vertical PNP transistor that improves the starting current (기동 전류를 개선한 수직 PNP 트랜지스터의 특성에 관한 연구)

  • Lee, Jung-Hwan
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.21 no.1
    • /
    • pp.1-6
    • /
    • 2016
  • In this paper, we introduce the characteristics of a vertical PNP transistor that improves start current by decreasing quiescent current with suppressing the parasitic transistor. In order to suppress the parasitic effect, we designed a vertical PNP transistor which suppresses parasitic PNP transistor by using the "DN+ links" without changing the circuit and made a LDO regulator using a standard IC processor. HFE of the fabricated parasitic PNP transistor decreased from conventional 18 to 0.9. Starting current of the LDO regulator made of the vertical PNP transistor using the improved "DN+ linked" structure is reduced from the conventional starting current of 90mA to 32mA. As the result, we developed a LDO regulator which consumes lower power in the standby state.

Operation modes and Protection of VS(Vertical Stabilization) Converter for International Thermonuclear Experimental Reactor (국제 핵융합실험로용 VS(Vertical Stabilization) 컨버터의 운전모드 및 보호동작)

  • Jo, Hyunsik;Jo, Jongmin;Oh, Jong-Seok;Suh, Jae-Hak;Cha, Hanju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.2
    • /
    • pp.130-136
    • /
    • 2015
  • This study describes the structure and operation modes of vertical stabilization (VS) converter for international thermonuclear experimental reactor (ITER) and proposes a protection method. ITER VS converter supplies voltage (${\pm}1000V$)/current (${\pm}22.5kA$) to superconducting magnets for plasma current vertical stabilization. A four-quadrant operation must be achieved without zero-current discontinuous section. The operation mode of the VS converter is separated in 12-pulse mode, 6-pulse mode and circulation current mode according to the magnitude of the load current. Protection measures, such as bypass and discharge, are proposed for abnormal conditions, such as over current, over voltage, short circuit, and voltage sag. VS converter output voltage is controlled to satisfy voltage response time within 20 msec. Bypass operation is completed within 60 msec and discharge operation is performed successfully. The feasibility of the proposed control algorithm and protection measure is verified by assembling a real controller and implementing a power system including the VS converter in RTDS for a hardware-in-loop (HIL) facility.

Three-dimensional structural health monitoring based on multiscale cross-sample entropy

  • Lin, Tzu Kang;Tseng, Tzu Chi;Lainez, Ana G.
    • Earthquakes and Structures
    • /
    • v.12 no.6
    • /
    • pp.673-687
    • /
    • 2017
  • A three-dimensional; structural health monitoring; vertical; planar; cross-sample entropy; multiscaleA three-dimensional structural health monitoring (SHM) system based on multiscale entropy (MSE) and multiscale cross-sample entropy (MSCE) is proposed in this paper. The damage condition of a structure is rapidly screened through MSE analysis by measuring the ambient vibration signal on the roof of the structure. Subsequently, the vertical damage location is evaluated by analyzing individual signals on different floors through vertical MSCE analysis. The results are quantified using the vertical damage index (DI). Planar MSCE analysis is applied to detect the damage orientation of damaged floors by analyzing the biaxial signals in four directions on each damaged floor. The results are physically quantified using the planar DI. With progressive vertical and planar analysis methods, the damaged floors and damage locations can be accurately and efficiently diagnosed. To demonstrate the performance of the proposed system, performance evaluation was conducted on a three-dimensional seven-story steel structure. According to the results, the damage condition and elevation were reliably detected. Moreover, the damage location was efficiently quantified by the DI. Average accuracy rates of 93% (vertical) and 91% (planar) were achieved through the proposed DI method. A reference measurement of the current stage can initially launch the SHM system; therefore, structural damage can be reliably detected after major earthquakes.

Calculation of Joule heating and temperature distribution generated in the KSTAR superconducting magnet structure

  • Seungyon Cho;Park, Chang-Ho;Sa, Jeong-Woo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.1
    • /
    • pp.78-83
    • /
    • 2002
  • Since the KSTAR superconducting magnet structure should be maintained at a cryogenic temperature of about 4 K, even a small amount of heat might be a major cause of the temperature rise of the structure. The Joule heating by eddy currents induced in the magnet structure during the KSTAR operation was found to be a critical parameter for designing the cooling scheme of the magnet structure as well as defining the requirements of the refrigerator for the cryogenic system. Based on the Joule heating calculation, it was revealed that the bulk temperature rise of the magnet coil structure was less than 1 K. The local maximum temperature especially at the inboard leg of the TF coil structure increased as high as about 21 K for the plasma vertical disruption scenario. For the CS coil structure, the maximum temperature was obtained from the PF fast discharging scenario. This means that the vertical disruption and PF fast discharging scenarios are the major scenarios for the design of TF and CS coil structures, respectively. For the reference scenario, the location of maximum temperature spot changes according to the transient current variation of each PF coil.

Fundamental period of infilled RC frame structures with vertical irregularity

  • Asteris, Panagiotis G.;Repapis, Constantinos C.;Foskolos, Filippos;Fotos, Alkis;Tsaris, Athanasios K.
    • Structural Engineering and Mechanics
    • /
    • v.61 no.5
    • /
    • pp.663-674
    • /
    • 2017
  • The determination of the fundamental period of vibration of a structure is essential to earthquake design. Current codes provide formulas for the approximate estimation of the fundamental period of earthquake-resistant building systems. These formulas are dependent only on the height of the structure or number of storeys without taking into account the presence of infill walls into the structure, despite the fact that infill walls increase the stiffness and mass of the structure leading to significant changes in the fundamental period. Furthermore, such a formulation is overly conservative and unable to account for structures with geometric irregularities. In this study, which comprises the companion paper of previous published research by the authors, the effect of the vertical geometric irregularities on the fundamental periods of masonry infilled structures has been investigated, through a large set of infilled frame structure cases. Based on these results, an attempt to quantify the reduction of the fundamental period due to the vertical geometric irregularities has been made through a proposal of properly reduction factor.

Development of Vibration Analysis Program for Anti-resonance Design of Vertical-axis Tidal Current Turbine (조류발전용 수직축 터빈의 공진 회피 설계를 위한 프로그램 개발)

  • Bae, Jae-Han;Seong, Hye-Min;Cho, Dae-Seung;Kim, Jae-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.336-341
    • /
    • 2012
  • The vertical-axis tidal current turbine (VAT) consisting of blades, struts to support blades, shaft, generator and so forth requires anti-resonance design against fluid fluctuation forces generated on blades to ensure its stable operation. In this study, a free vibration analysis program based on the finite element method is developed for efficient anti-resonance design of VAT in the preliminary design stage. In the finite element modeling, the VAT structure components are regarded as beam elements. Added masses due to the fluid and structure interaction of VAT evaluated by empirical formulas are considered as lumped mass elements. In addition, input parameters required for the analysis can be automatically prepared from the principal dimensions of VAT to make anti-resonance design more convenient. The validity of applied methods is verified by the comparison of the numerical results obtained from MSC/Nastran and the developed program for two VAT models.

  • PDF