• 제목/요약/키워드: vernier

검색결과 113건 처리시간 0.028초

Comparison of Three Magnet Array-type Rotors in Surface Permanent Magnet-type Vernier Motor

  • Kataoka, Yasuhiro;Takayama, Masakazu;Matsushima, Yoshitarou;Anazawa, Yoshihisa
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권1호
    • /
    • pp.1-8
    • /
    • 2013
  • Surface permanent magnet-type vernier motors with three magnet array-type rotors (parallel magnetized type, repulsion type, and Halbach type) are compared based on the pull-out torque. It was clarified that increasing the rotor radius increases the pull-out torque at a fixed three-phase alternating voltage. The mechanism for the pull-out torque increase on each magnet array type was different, when the effects of the increase were analyzed based on an induced electromotive force and a synchronous reactance. As a result, the design of the Halbach-type rotor was found to be especially effective for achieving high pull-out torque, because this array type achieves a large induced electromotive force $E_0$ and a small synchronous reactance $x_s$.

Design of Surface Permanent Magnet-type Vernier Motor

  • Kakihata, Hironori;Kataoka, Yasuhiro;Takayama, Masakazu;Matsushima, Yoshitarou;Anazawa, Yoshihisa
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권2호
    • /
    • pp.127-133
    • /
    • 2013
  • In this paper, the authors designed a surface permanent magnet (SPM)-type vernier motor whose maximum output is more than 5.2 kW, whose power factor at 4 kW is more than 90%, and whose efficiency at 4 kW is 85% under the conditions that the operating voltage, frequency, and synchronous speed are 400 V, 50 Hz, and 100 min-1, respectively.

Mover Field Oriented Control of Linear Permanent-Magnet Vernier Motor Considering Loss Minimization

  • Qiu, Xianqun;Zhao, Wenxiang;Chen, Qian;Xu, Dezhi
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권3호
    • /
    • pp.1114-1123
    • /
    • 2017
  • A linear permanent-magnet vernier (LPMV) motor has magnets and windings in the short mover, which is very suitable for long stroke applications. This paper proposed a new field oriented control with space vector pulse width modulation for the LPMV motor, which considers loss minimization. First, the topology of the LPMV motor is briefly presented. Then, the mathematical model is derived, and the mover field oriented control strategy is proposed. Also, the loss analysis is performed. Finally, the simulated and experimental results are given, verifying the feasibility and effectiveness of the proposed control strategy.

사랑니 길이 측정을 통한 파노라마와 CBCT의 정확도 연구 (Study on accuracy of panorama and CBCT through length measurement of wisdom teeth)

  • 정천수;김종일
    • 한국방사선학회논문지
    • /
    • 제7권2호
    • /
    • pp.131-136
    • /
    • 2013
  • 치과 방사선 발생장치 중 파노라마는 구강악안면의 넓은 해부학적 구조물을 관찰할 수 있으나, 길이나 각도, 형태의 왜곡이 일어날 수 있다. CBCT는 3차원적 영상진단을 할 수 있으며, 해부학적 구조물 사이의 중첩과 간섭에 의한 오차가 현저히 적은 영상을 얻을 수가 있으나, 시간이 길어 피사체의 움직임에 의해 상의 질이 저하될 수 있고 구강 내에 금속 같은 방사선 불투과성 물체가 존재하면 그 물체를 중심으로 방사상으로 방사선 불투과성 선이 나타날 수 있다. 본 연구에서는 파노라마와 CBCT로 측정된 사랑니 길이와 실제 발치된 치아를 비교하여 치아의 왜곡을 분석함으로써 파노라마와 CBCT의 정확도를 분석하고, 치과 치료시 해부학적으로 유용한 정보를 얻고자 한다. 실험결과 파노라마와 Digital Vernier Caliper의 오차는 크게는 110.7%, 작게는 103.9%로 평균적으로 파노라마가 평균 7.3%로 확대됨을 알 수 있었다. CBCT와 Digital Vernier Caliper에서 측정된 사랑니의 길이는 오차범위 1.3%로 나타났고, 파노라마와 Digital Vernier Caliper에서 측정된 사랑니의 길이는 오차범위 7.3%를 나타냄으로써 CBCT가 파노라마보다 약 6% 정확한 영상을 나타냄을 알 수 있었다. CBCT가 파노라마보다 정확한 영상을 나타냄을 확인할 수 있었지만 CBCT는 파노라마보다 검사비용이 비싸고 피폭선량 또한 많아서 검사 시 적절한 방법을 찾아야 할 것으로 사료된다.

웨이퍼 스텝퍼에서의 기준정렬을 위한 2차원 버니어 패턴의 성능예측

  • 이종현;장원익;최부연;장기호;김도훈;유형준
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1993년도 추계학술대회 논문집
    • /
    • pp.243-248
    • /
    • 1993
  • New methodology for fiducial alignment is proposed to improve the alignment accuracy in wafer steppers. The positioning error is detected by PSD(Position Sensitive Detector)when 2-dimensional vernier patterns on a reticle on a reticle are projected on the fiducial marks of wafer stage. The width and period of vernier patterns are deter mined to get the highest S/N ratio for the exposure wavelength 248.4nm of KrF excimer laser. This new method has an advantage of higher accuracy and faster alignment over the conventional one.

  • PDF

다이렉트 드라이브 시스템을 위한 이중 고정자 영구자석 버니어 머신의 시제품과 실험 (Prototype and Test of A Dual-stator PM Vernier Machine for Direct-drive Systems)

  • 조비;권병일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.678-679
    • /
    • 2015
  • A prototype of a dual-stator axial-flux PM vernier machine with rated 5.5kW output power at 300rpm speed is constructed and tested to verify its competitive performance and the reliability of the proposed design approach and the FEM simulation results.

  • PDF

A COMOS Oversampling Data Recovery Circuit With the Vernier Delay Generation Technique

  • Jun-Young Park
    • 한국통신학회논문지
    • /
    • 제25권10A호
    • /
    • pp.1590-1597
    • /
    • 2000
  • This paper describes a CMOS data recovery circuit using oversampling technique. Digital oversampling is done using a delay locked loop circuit locked to multiple clock periods. The delay locked loop circuit generates the vernier delay resolution less than the gate delay of the delay chain. The transition and non-transition counting algorithm for 4x oversampling was implemented for data recovery and verified through FPGA. The chip has been fabricated with 0.6um CMOS technology and measured results are presented.

  • PDF

PDA기반의 블루투스 무선통신 방사선 측정 장치 (PDA based Bluetooth Wireless Radiation Counter)

  • 임상희;박대성;진계환
    • 한국방사선학회논문지
    • /
    • 제2권1호
    • /
    • pp.5-10
    • /
    • 2008
  • 본 연구에서는 PDA 기반의 블루투스를 이용한 무선통신 방사선 측정 장치를 개발하였다. 제안하는 시스템은 방사선 측정 센서로 GM (Geiger-Mueller) 계수관을 이용하는 Vernier사의 Student Radiation Monitor, 데이터 획득을 위한 모듈로는 Vernier사의 LabPro, 데이터의 무선전송을 위하여 Initium사의 최대 30미터까지 블루투스 통신이 가능한 Promi-SD 101, 데이터의 저장과 디스플레이에는 운영체계로 Pocket PC 2003이 내장된 HP사의 5550으로 구성하였다. 방사선측정센서로 GM 계수관을 이용하였으므로 방사선 에너지 측정은 불가능하고 카운트 양과 카운트율을 측정할 수 있다. PC를 이용한 시스템의 자연방사선 계측치와 PDA를 이용한 시스템의 자연방사선 계측치를 비교한 결과, 제안하는 시스템은 자료의 왜곡 없이 송수신이 이루어지고 있음을 확인하였다.

  • PDF

컴퓨터를 이용한 치아크기 계측시 재현도와 정확도에 관한 연구 (Reproducibility and accuracy of tooth size measurements obtained by the use of computer)

  • 김은정;황현식
    • 대한치과교정학회지
    • /
    • 제29권5호
    • /
    • pp.563-573
    • /
    • 1999
  • 본 연구는 치아크기 측정시 버니어 캘리퍼스를 사용한 계측치와 석고모형을 촬영하여 컴퓨터를 사용한 계측치를 서로 비교함으로써 석고모형 분석시 컴퓨터 이용 가능성을 알아보고자 시행되었다. 치아밀집치열 특징을 지니며 모든 치아의 맹출이 완료된 상하악 20조의 석고 모형의 좌측 중절치부터 제 1대구치까지 12개의 치아를 대상으로 하여, 각 치아의 근원심폭경을 버니어 캘리퍼스와 컴퓨터를 이용하여 2주 간격으로 2회 측정하여 실험측정치를 얻은 다음, 측정에 이용된 석고모형을 근원심접촉점 부위에서 개개치아로 분리한 후, 마이크로미터를 이용하여 측정한 표준치와 비교분석하였다. 계측시 오차의 원인을 알아보기 위하여 상하악의 occlusogram을 얻어 각 치아의 접촉점 이탈유무 및 정도를 구하고, TARG (Torque Angulation Reference Guide)를 이용하여 각 치아의 근원심경사도를 계측한 결과 다음과 같은 결론을 얻었다. 1. 2회 측정에 대한 재현도 비교시 버니어 캘리퍼스를 사용한 경우 12 개 치아 중 3개의 치아에서 유의한 차이가 나타났으며 컴퓨터의 경우에는 1 개의 치아에서 차이가 나타났다. 2. 치아크기 계측의 정확도를 알아보기 위하여 표준치와 비교한 결과, 버니어 캘리퍼스를 사용한 경우 12개 중 3개의 치아에서 유의한 차이가 있었으며 컴퓨터의 경우에는 12 개 중 2 개의 치아에서 차이가 나타났다. 3. 버니어 캘리퍼스를 사용한 경우 상악 제 1 대구치는 표준치에 비해 크게, 하악 제 1 대구치는 표준치에 비해 작게 재는 경향을 보였으며 컴퓨터의 경우 상하 제 1 대구치 모두 표준치에 비해 크게 재는 경향을 보였다. 4. 버니어 캘리퍼스로 계측시에는 하악 제 1 대구치가 가장 큰 오차를 보였으며 치아별로 오차정도가 다양하게 나타난 반면, 컴퓨터의 경우 치아별 오차정도의 차이를 보이지 않았다. 5. 접촉점 이탈정도 및 치관의 근원심 경사도와 오차정도의 상관성을 살펴본 결과 버니어 캘리퍼스로 측정한 경우 유의한 상관관계를 보이지 않았으나 컴퓨터로 계측한 경우 약한 순상관관계를 보였다. 이상의 결과는 모형분석을 위한 치아크기 계측시 컴퓨터 이용이 가능함을 시사하였다.

  • PDF

시간-디지털 변환기의 성능 개선에 대한 연구 (A Study on the Performance Improvement of a Time-to-Digital Converter)

  • 안태원;이종석;문용
    • 전자공학회논문지 IE
    • /
    • 제49권1호
    • /
    • pp.1-6
    • /
    • 2012
  • 본 논문에서는 시간-디지털 변환기의 성능 개선을 위하여, 높은 해상도의 2단 시간-디지털 변환기(TDC)를 설계하였다. TDC 중간에 2단 버니어 시간 증폭기(2-S VTA)를 사용하여 2단 구조를 갖도록 하였다. 2단 버니어 시간 증폭기는 기존의 시간 증폭기에 비해 이득이 64 이상으로 매우 크기 때문에 전체 2단 TDC의 해상도를 높인다. TDC는 버니어 구조를 사용하였기 때문에 고급 공정에 제한받지 않고, 높은 해상도를 얻을 수 있다. 제안하는 2단 TDC는 $0.18{\mu}m$ CMOS 공정으로 설계하였고, 전원 전압은 1.8V로 모의실험 하였다. 전체 입력 범위는 512ps이고 전체 해상도는 0.125ps이다.