• Title/Summary/Keyword: variable discharge

Search Result 230, Processing Time 0.026 seconds

Development of the Wire EDM CAM System Considering a Variab1e Taper Wire-cut and an Unmanned Wire EDM During the Night (상하이형상 및 야간 무인가공을 고려한 와이어 EDM 전용 CAM 시스템 개발)

  • 유우식;정회민
    • Korean Journal of Computational Design and Engineering
    • /
    • v.6 no.3
    • /
    • pp.206-214
    • /
    • 2001
  • This paper describes the wire EDM (Electric Discharge Machining) CAM system considering a variable taper wire-cut and an unmanned wire EDM during the night. Wire EDM is applicable to all materials that are fairly good electrical conductors, including metals, alloys and most carbide. Thus it provides a relatively simple method for making holes of any desired cross section in materials that are too hard or brittle to be machined by most other methods. In this paper we classify variable taper wire-cut machining patterns and variable taper wire-cut geometries. Also we determine unmanned wire EDM patterns fur the productivity of wire EDM industry. Developed system consists of two modules: 1) Variable taper wire EDM module guarantees the length ratio machining function, the parametric ratio machining function and the marking function. 2) Unmanned wire EDM module guarantees the automatic wire EDM during the night. The proposed system has been tested in the fields and found to be a useful system.

  • PDF

Highly Sensitive Partial Discharge Sensor with Remote Monitoring Capabilities (원격감시 기능을 갖는 고감도 부분방전센서)

  • Choi, Kyoo-Nam
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.3
    • /
    • pp.349-356
    • /
    • 2015
  • Remote monitoring partial discharge sensor, equipping with hybrid filter combining optical and electrical noise reduction capabilities and with signal integrating function to calculate total arc energy, was investigated. Hybrid filter showed insensitivity to fluorescent and incandescent lamps under simulated distribution panel condition. Signal integrating function showed selective detection capability corresponding to different arc energy levels, while convention arc sensor had difficulty to discriminate arc energy level due to bursty arc waveform and peak level detection characteristics. The sensor showed possibility for application to remote monitoring partial discharge sensor, since it detected arc energy level corresponding to normal open and close discharge in low voltage 100A MCCB at 2m distance.

Modified Ramp-Reset Waveform Robust for Variable Panel Temperature and its Discharge Characteristics

  • Jang, Soo-Kwang;Tae, Heung-Sik;Kim, Soon-Bae;Jung, Eun-Young;Suh, Kwang-Jong;Ahn, Jung-Chull;Heo, Eun-Gi;Lee, Byung-Hak;Lee, Kwang-Sik
    • Journal of Information Display
    • /
    • v.7 no.1
    • /
    • pp.25-29
    • /
    • 2006
  • By the voltage threshold (Vt) close-curve measurement method, the changes in the discharge characteristics such as a firing voltage and IR emission among the three electrodes were examined relative to the low or high panel temperature ranging from -10 to $80^{\circ}$. The variation in the panel temperature was found significantly influence the surface discharge between the MgO surfaces rather than the plate gap discharge between the MgO and phosphor layers. Based on this experimental observation, a modified reset waveform that alleviates the surface discharge during a ramp-up and -down period was deeloped. By adopting the proposed reset waveform, a stable address discharge could be obtained irrespective of the panel temperature variation.

Partial Discharge Localization Based on Detailed Models of Transformer and Wavelet Transform Techniques

  • Hassan Hosseini, Seyed Mohammad;Rezaei Baravati, Peyman
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1093-1101
    • /
    • 2015
  • Partial Discharge (PD) is a physical phenomenon, which causes defects and damages to the insulation. This phenomenon is regarded as the most important source of fault and defect in power transformers. Therefore, methods of high speed and precision are considered of special importance for the maintenance of transformers in localization of the origin of partial discharge. In this paper, the transformer winding is first modeled in a transient state by using RLC ladder network and multiconductor transmission line (MTL) models. The parameters of the two models were calculated by Ansoft Maxwell software, and the simulations were performed by Matlab software. Then, the PD pulses were applied to the models with different widths of pulses. With regard to the fact that the signals received after the application of PD had a variable frequency nature over time, and based on the wavelet transform and signal energy, a new method was presented for the localization of PD. Ultimately; the mentioned method was implemented on a 20 kV winding distribution transformer. Then, the performances of the models used in this paper, including RLC and MTL models, were compared in different frequency bands for the correct distinction of partial discharge location.

Flowrate Measurement Using Segmental Wedge as a Restriction Device for Differential Pressure (Segmental Wedge를 이용한 차압식 유량측정 방법)

  • Yoon, J.Y.;Sung, N.W.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.302-307
    • /
    • 2005
  • The discharge coefficient in segmental wedge having ninety degrees vertex angle for the five kinds of opening ratio with differential pressure taps located at both upstream and downstream of one diameter of pipe was measured main purpose of this work is placed on developing the proper form of an equation for the discharge coefficient of a segmental wedge used as a primary element of flow metering devices, and from thata six-term equation which can express the variability of opening ratios was developed. The same assumption and hypotheses were used and tested for all procedures as conventional differential producers; however, the range of the opening ratio over this work is more expanded than previous studies. The opening ratios of segmental wedge, namely 0.3, 0.4, 0.5, 0.6 and 0.7 were investigated the Reynolds number based on the spool inside diameter ranges from 12,000 to 380,000, the resulting equation for the discharge coefficient is relatively simple; it contains only one variable-opening ratio because the characteristic of discharge coefficient of segmental wedge has little connection with the Reynolds number as shown by previous studies.

  • PDF

A Study on Flash Flood Warning in Mountainous Area (산악지역 돌발홍수 경보발령 기준 설정에 관한 연구)

  • Jun, Kye-Won;Oh, Chae-Yeon;Yeon, Gyu-Bang;Lee, Seung-Chul;Jun, Byong-Hee
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.591-594
    • /
    • 2007
  • The purpose of this study is to estimate the critical flood discharge and flash flood trigger rainfall for alarm system providing for a flash flood in mountainous. This study was effectively estimated a topographic characteristic factor of basin using the GIS. Especially, decided stream order using GIS at stream order decision that is important for input variable of GCIUH. Result that calculate threshold discharge to use GCIUH, at the Mureung valley basin, flash flood trigger rainfall was 16.34mm in the first 20 minutes when the threshold discharge was $14.54\;m^3/sec$.

  • PDF

A Study on Color Control in Gas Discharge Tube with the Variation of Frequency (주파수 변화에 따라 기체 방전관 색상 제어에 관한 연구)

  • Lee, Jong-Chan;Park, Dae-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.53-56
    • /
    • 1996
  • In this paper, the pulsed mode operated gas discharge tube is composed with mixed gas of Hg-Ne (10 Torr), in the tube of 15.0 mm outer diameter and has variable color from red to blue with changing frequency high voltage. As increasing frequency in the gas discharge tube, the phenomena, that the electron temperature in the positive column increases and the radiation from atoms of higher upper state energy levels increases, exist The color have the locus from red (0.4972, 0.3128) to blue (0.2736, 0.2619) in CIE chromacity diagram with increasing frequency. The method of changing frequency has been shown to be suitable for the luminous color control.

  • PDF

Controller Design of Stand-Alone Photovoltaic System with Charge-Discharge Controller for Remote lsland Power Supply

  • Kang, Ki-Hwan;Yu, Gwon-Jong;Song, Jinsoo;Jeong, Young-Seok;Kang, Ki-Hwan;Lee, Byoung-Ku;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.972-977
    • /
    • 1998
  • This paper deals with stand-alone Photovoltaic system(SPVS) with charge and discharge controller. Main power source of SPVS are generally solar cell and battery. Therefore SPVS can be classified into variable types in accordance with connection method between battery and solar cell array. Mainly used one of them is direct connection type which has advantages such as simple structure and simple controller. However most big drawback of this system is energy loss by voltage disharmony between solar cell array and battery. Therefore SPVS with charge and discharge controller which can operate solar cell array at maximum power point is designed and experimented with a laboratory prototype.

  • PDF

Design of Stand-Alone Photovoltaic System with Charge-Discharge Controller (충방전 제어기를 이용한 독립형 태양광 발전시스템의 설계)

  • 김홍성;유권종;송진수;이병구;정영석;강기환;최규하
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.103-108
    • /
    • 1998
  • This paper deals with stand-alone Photovoltaic system(SPVS) with charge and discharge controller. Main power source of SPVS are generally solar cell and battery. Therefore SPVS can be classified into variable types in accordance with connection type between battery and solar cell. Mainly used one of them is direct connection type which has advantages such as simple structure and simple controller. However most big drawback of this system is energy loss by voltage disharmony between solar cell and battery. Therefore SPVS with charge and discharge controller which can operate solar cell at maximum power point is designed and analyzed by simulation in this paper.

  • PDF

Experiment and Electro-Thermo-Chemical Modeling on Rapid Resistive Discharge of Large-Capacity Lithium Ion Battery

  • Doh, Chil-Hoon;Ha, Yoon-Cheol;Eom, Seung-Wook;Yu, Jihyun;Choe, Seon-Hwa;Kim, Seog-Whan;Choi, Jae-Won
    • Journal of Electrochemical Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.323-338
    • /
    • 2022
  • Heat generation and temperature of a battery is usually presented by an equation of current. This means that we need to adopt time domain calculation to obtain thermal characteristics of the battery. To avoid the complicated calculations using time domain, 'state of charge (SOC)' can be used as an independent variable. A SOC based calculation method is elucidated through the comparison between the calculated results and experimental results together. Experiments are carried for rapid resistive discharge of a large-capacitive lithium secondary battery to evaluate variations of cell potential, current and temperature. Calculations are performed based on open-circuit cell potential (SOC,T), internal resistance (SOC,T) and entropy (SOC) with specific heat capacity.