• Title/Summary/Keyword: unit testing

Search Result 621, Processing Time 0.024 seconds

A Fundamental Study of Ferro Copper Slag for Concrete Aggregate (동슬래그의 콘크리트용 골재 활용에 관한 기본연구)

  • Song, Tae-Hyeob;Lee, Mun-Hwan;Lee, Sea-Hyun
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.1
    • /
    • pp.35-42
    • /
    • 2003
  • To use ferro copper slag as aggregate in the construction, an evaluation upon the two kinds of ferro copper slag being produced was conducted to determine the basic physical, and mechanical properties, chemical component and environmental noxiousness. As a result of experiment, it was found that two kinds of ferro copper slag satisfies the physical and mechanical properties of aggregate, prescribed in KS F 2526, and that in the result of noxious heavy metal eruption test by single bach extraction, no eruption of noxious heavy metal was detected or the eruption was far below the reference value. And mortar test was conducted by replacing sand of 25, 50, 75, 100% and the performance level was presented upon reviewing the fluidity property and variable aspects of unit weight. The increase of strength in accordance with replacement rate of sand was found to be the below than the equivalent level compared to the testing specimens that did not use ferro copper slag, but those of 25% replacement rate was above than 0%. Thus, two kinds of ferro copper slag, produced in the domestic, were found to be possessing the enough physical properties to use as concrete aggregate assuming that used with sand and in particular, it was reviewed to be advantageous in manufacturing concrete or mortar that requires weight.

EFFECTS OF VARIOUS CEMENTS AND THERMOCYCLING ON RETENTIVE STRENGTHS OF CEMENTED IMPLANT-SUPPORTED PROSTHESES (시멘트 유지형 임플란트 보철물의 유지력에 시멘트의 종류와 열순환이 미치는 영향에 관한 연구)

  • Cho Jae-Ho;Jeong Chang-Mo;Jeon Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.4
    • /
    • pp.466-475
    • /
    • 2003
  • Statement of problem : In cemented implant-supported porstheses, it is still controversy what kind of cement to use. However, the effect of thermocycling on retentive strength of cemented implant-supported prostheses has not been well investigated. Purpose : This study was tested to evaluate the effects of various cements and thermocycling on retentive strengths of cemented implant-supported prostheses. Material and methods : Prefabricated implant abutments, height 5mm, diameter 6mm, 3-degree taper per side, with light chamfer margins were used. Ten specimens of two-unit fred partial denture were fabricated. The luting agents used for this study were three provisional luting agents which were Temp bond, Temp bond NE, IRM and four permanent luting agents which were Panavia F, Fuji-cem, Hy-bond Zinc cement, Hy-bond Polycarboxylate cement. 24 hours after cementation. the retentive strengths were measured by the universal testing machine with a cross-head speed of 0.5mm/min. Then cementation procedures were repeated and specimens were thermocycled 1000 times at temperature of $5^{\circ}C$ and $55^{\circ}C$. After thermocycling, the retentive strengths were measured. Results : Before thermocycling, the retentive strengths were decreased with the sequence of Panavia F. Fuji-cem. Hy-bond Zinc cement. Hy-bond Polycarboxylate cement, IRM, Temp bond NE and Temp bond, and there were significant differences among each groups(p<0.05). After thermocycling, the retentive strengths were decreased with the sequence of Panavia F. Fuji-cem, Hybond Zinc cement, Hy-bond Polycarboxylate cement, IRM, Temp bond NE and Temp bond, and there were no significant differences among Panavia F, Fuji-cem and Temp bond NE, Temp bond(p>0.05). The retentive strengths before and after thermocycling showed significant differences in Hy-bond Zinc cement. IRM, Temp bond NE and Temp bond(p<0.05). Conclusion : Within the limitation of this study, thermocycling do not affect the retentive strengths of permanent luting agents but the retentive strengths of temporary cements were reduced significantly after thermocyling.

Psychometrics of Task Self-Efficacy Scale for Korean Elderly (노인의 일상활동수행에 대한 자기효능척도의 신뢰도 및 타당도 평가)

  • ;;;;Beverly L. Roberts
    • Journal of Korean Academy of Nursing
    • /
    • v.27 no.4
    • /
    • pp.831-842
    • /
    • 1997
  • The purpose of the study was to test the reliability and validity of the Korean version of Task Self-Efficacy Scale for activities of dally living (ADL). The Task Self-Efficacy Scale was developed by Roberts(1996) for low-intensity exercise study with older people to predict their performance of ADL. The scale was translated and back translated by bilingual persons, and then was modified to resolve variations in the translations. The Korean version of Self-Efficacy Scale for ADL was then administered to 193 elderly people including 95 hospitalized patients and 98 outpatients or healthy people. Face to face interview was used to fill out the structured questionnaire, and each interview took approximately 30 minutes. The subjects for the study were 80 women and 112 men with an age range of 65 to 95 years(M=71 years) of whom 82.6% classified themselves as moderate or quite active Most subjects(80.2%) had an education level of elementary school or less. The Self-Efficacy Scale for ADL is measured on a 0 to 10 VAS, assessing three areas of ADL : self care activities, household tasks, and motor tasks. The higher the score is, the higher person's confidence in performing ADL. Psychometric testing revealed that the scale was found to be internally consistent, showing a Cronbach's alpha of .97 The scale was significantly correlated with subjects' level of activity and subjective assessment of their health status. Moderate correlation with health-related hardiness scale also supported the validity. Factor analysis was performed to confirm whether the scale represents the three sub-areas as suggested in the literature. The results of the factor analysis led to a three factor solution according to Kaiser's criterion, but the items were not strongly and cleanly loaded for the third factor. This can be explained in that, among the three sub-ADL areas of the self-efficacy scale, the areas of self care activities and household tasks seem to have similar levels of difficulty in performance with not enough differences for the self-efficacy scale to distinguish between the two areas. Therefore, one factor solution was suggested since ADL can be seen as a unit of activities at similar level of difficulty in performance. One factor solution explained 68.1% of variance of the 19-item scale and all items were correlated over .6 with the factor, showing that the selected factor solution fits the model. The results indicated that the Korean version of Task Self-Efficacy Scale for ADL was reliable and valid in producing useful information to evaluate the effects of various interventions toward promoting health and quality of life for elderly people.

  • PDF

Autosomal-dominant Polycystic Kidney Disease in a Family of Scottish Fold Cats (스코티쉬 폴드 고양이 가족에 발생한 상염색체 우성 다낭성 신병)

  • Seo, Kyoung-Won;Kim, Sae-Um;Ahn, Jin-Ok;Coh, Ye-Rin;Han, Sung-Young;Youn, Hwa-Young
    • Journal of Veterinary Clinics
    • /
    • v.27 no.6
    • /
    • pp.726-728
    • /
    • 2010
  • Autosomal-dominant polycystic kidney disease (AD-PKD) is common in Persian and Persian-related breeds, and is sporadically reported in Scottish Fold cats. A 5-year-old male Scottish Fold cat was diagnosed with polycystic kidney disease based on screening tests and abdominal ultrasonography and died 3.5 months after diagnosis. The cat had 14 kittens with three queens, including his female sibling, with an age range of 3 months to 8 years. Genetic testing to confirm the genetic transmission of AD-PKD which detects the mutated PKD1 gene was performed. Abdominal ultrasonography confirmed the presence of renal cysts. Nineteen cats were screened in the present study (13 males and 6 females), with an age range of 3 months to 8 years. The results of renal ultrasonography agreed with the genetic test results in the 19 cats in which both tests were performed and 8 cats were diagnosed as ADPKD based on these tests. AD-PKD has not been investigated in cats in South Korea. Moreover, this is the first report of AD-PKD in a family unit of Scottish Fold cats.

Photocatalytic Degradation and Detoxification of Bisphenol A Using TiO2 Nanoparticles (TiO2 나노입자 광촉매 반응에 의한 비스페놀 A의 분해 제거 및 독성 저감)

  • Jo, A-Yeong;Jung, Jinho
    • Ecology and Resilient Infrastructure
    • /
    • v.2 no.4
    • /
    • pp.330-336
    • /
    • 2015
  • Photocatalytic degradation of bisphenol A (BPA) in aqueous solution was investigated using $TiO_2$ nanoparticles (Degussa P25) in this study. After a 3 hr photocatalytic reaction (${\lambda}=365nm$ and $I=3mW\;cm^{-2}$, $[TiO_2]=2.0g\;L^{-1}$), 98% of BPA ($1.0{\times}10^{-5}M$) was degraded and 89% of the total organic carbon was removed. In addition, BPA degradation by photolytic, hydrolytic and adsorption reactions was found to be 2%, 5% and 13%, respectively. The reaction rate of BPA degradation by photocatalysis decreased with increasing concentration of methanol that is used as a hydroxyl radical scavenger. This indicates that the reaction between BPA and hydroxyl radical was the key mechanism of BPA degradation. The pseudo-first-order reaction rate constant for this reaction was determined to be $7.94{\times}10^{-4}min^{-1}$, and the time for 90% BPA removal was found to be 25 min. In addition, acute toxicity testing using Daphnia magna neonates (< 24 h old) was carried out to evaluate the reduction of BPA toxicity. Acute toxicity (48 hr) to D. magna was decreased from 2.93 TU (toxic unit) to non-toxic after photocatalytic degradation of BPA for 3 hr. This suggests that there was no formation of toxic degradation products from BPA photocatalysis.

A Study on the Development of Diagnosing System of Defects on Surface of Inner Overlay Welding of Long Pipes using Liquid Penetrant Test (PT를 이용한 파이프내면 육성용접부 표면결함 진단시스템 개발에 관한 연구)

  • Lho, Tae-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.121-127
    • /
    • 2018
  • A system for diagnosing surface defects of long and large pipe inner overlay welds, 1m in diameter and 6m in length, was developed using a Liquid Penetrant Test (PT). First, CATIA was used to model all major units and PT machines in 3-dimensions. They were used for structural strength analysis and strain analysis, and to check the motion interference phenomenon of each unit to produce two-dimensional production drawings. Structural strength analysis and deformation analysis using the ANSYS results in a maximum equivalent stress of 44.901 MPa, which is less than the yield tensile strength of SS400 (200 MPa), a material of the PT Machine. An examination of the performance of the developed equipment revealed a maximum travel speed of 7.2 m/min., maximum rotational speed of 9 rpm, repeatable position accuracy of 1.2 mm, and inspection speed of $1.65m^2/min$. The results of the automatic PT-inspection system developed to check for surface defects, such as cracks, porosity, and undercut, were in accordance with the method of ASME SEC. V&VIII. In addition, the results of corrosion testing of the overlay weld layer in accordance with the ferric chloride fitting test by the method of ASME G48-11 indicated that the weight loss was $0.3g/m^2$, and met the specifications. Furthermore, the chemical composition of the overlay welds was analyzed according to the method described in ASTM A375-14, and all components met the specifications.

Peel strength of denture liner to PMMA and polyamide: laser versus air-abrasion

  • Korkmaz, Fatih Mehmet;Bagis, Bora;Ozcan, Mutlu;Durkan, Rukiye;Turgut, Sedanur;Ates, Sabit Melih
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.3
    • /
    • pp.287-295
    • /
    • 2013
  • PURPOSE. This study investigated the effect of laser parameters and air-abrasion on the peel strength of silicon-based soft denture liner to different denture resins. MATERIALS AND METHODS. Specimens (N=180) were prepared out of three different denture base resins (Rodex, cross-linked denture base acrylic resin; Paladent, heat-cured acrylic resin; Deflex, Polyamide resin) ($75mm{\times}25mm{\times}3mm$). A silicon-based soft denture liner (Molloplast B) was applied to the denture resins after the following conditioning methods: a) Air-abrasion ($50{\mu}m$), b) Er,Cr:YSGG laser (Waterlase MD Turbo, Biolase Technology) at 2 W-20 Hz, c) Er,Cr:YSGG laser at 2 W-30 Hz, d) Er,Cr:YSGG laser at 3 W-20 Hz, e) Er,Cr:YSGG laser at 3 W-30 Hz. Non-conditioned group acted as the control group. Peel test was performed in a universal testing machine. Failure modes were evaluated visually. Data were analyzed using two-way ANOVA and Tukey's test (${\alpha}$=.05). RESULTS. Denture liner tested showed increased peel strength after laser treatment with different parameters ($3.9{\pm}0.4-5.58{\pm}0.6$ MPa) compared to the control ($3.64{\pm}0.5-4.58{\pm}0.5$ MPa) and air-abraded groups ($3.1{\pm}0.6-4.46{\pm}0.3$ MPa), but the results were not statistically significant except for Paladent, with the pretreatment of Er,Cr:YSGG laser at 3 W-20 Hz. Polyamide resin after air-abrasion showed significantly lower peel strength than those of other groups ($3.1{\pm}0.6$ MPa). CONCLUSION. Heat-cured acrylic resin, PMMA, may benefit from Er,Cr:YSGG laser treatment at 3 W-20 Hz irradiation. Air-abrasion of polyamide resins should be avoided not to impair their peel bond strengths to silicon-based soft denture liners.

Bond strength of veneer ceramic and zirconia cores with different surface modifications after microwave sintering

  • Saka, Muhammet;Yuzugullu, Bulem
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.4
    • /
    • pp.485-493
    • /
    • 2013
  • PURPOSE. To evaluate the effects of surface treatments on shear bond strength (SBS) between microwave and conventionally sintered zirconia core/veneers. MATERIALS AND METHODS. 96 disc shaped Noritake Alliance zirconia specimens were fabricated using YenaDent CAM unit and were divided in 2 groups with respect to microwave or conventional methods (n=48/group). Surface roughness (Ra) evaluation was made with a profilometer on randomly selected microwave (n=10) and conventionally sintered (n=10) cores. Specimens were then assessed into 4 subgroups according to surface treatments applied (n=12/group). Groups for microwave (M) and conventionally (C) sintered core specimens were as follows; $M_C$,$C_C$: untreated (control group), $M_1,C_1:Al_2O_3$ sandblasting, $M_2,C_2$:liner, $M_3,C_3:Al_2O_3$ sandblasting followed by liner. Veneer ceramic was fired on zirconia cores and specimens were thermocycled (6000 cycles between $5^{\circ}-55^{\circ}C$). All specimens were subjected to SBS test using a universal testing machine at 0.5 mm/min, failure were evaluated under an optical microscope. Data were statistically analyzed using Shapiro Wilk, Levene, Post-hoc Tukey HSD and Student's t tests, Two-Way-Variance- Analysis and One-Way-Variance-Analysis (${\alpha}$=.05). RESULTS. Conventionally sintered specimens ($1.06{\pm}0.32{\mu}m$) showed rougher surfaces compared to microwave sintered ones ($0.76{\pm}0.32{\mu}m$)(P=.046), however, no correlation was found between SBS and surface roughness (r=-0.109, P=.658). The statistical comparison of the shear bond strengths of $C_3$ and $C_1$ group (P=.015); $C_C$ and $M_C$ group (P=.004) and $C_3$ and $M_3$ group presented statistically higher (P=.005) values. While adhesive failure was not seen in any of the groups, cohesive and combined patterns were seen in all groups. CONCLUSION. Based on the results of this in-vitro study, $Al_2O_{3-}$ sandblasting followed by liner application on conventionally sintered zirconia cores may be preferred to enhance bond strength.

Clinical Features of Hospitalized Adult Patients with Pneumonia in Novel Influenza A (H1N1) Infection (신종 인플루엔자 A (H1N1) 감염으로 입원한 성인 폐렴 환자의 임상양상)

  • Han, Chang-Hoon;Hyun, Yu-Kyung;Choi, Yu-Ri;Sung, Na-Young;Park, Yoon-Seon;Lee, Kkot-Sil;Chung, Jae-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.69 no.1
    • /
    • pp.24-30
    • /
    • 2010
  • Background: A novel 2009 influenza A (H1N1) virus emerged and disseminated to all over the world. There are few reports on the clinical characteristics of patients with complications. We describe the clinical features of pneumonia in adult patients hospitalized, who have novel influenza infection. Methods: There were 43 adult patients enrolled into the study with pneumonia of 528 hospitalized patients confirmed influenza A (H1N1) virus infection by real-time reverse transcriptase polymerase chain reaction testing, between 24 August 2009 and 31 January 2010. The clinical data of patients with pneumonia were collected retrospectively. Results: There were 22 of 43 (51.2%) influenza patients with pneumonia that had higher risk factors for complications. Compared to 28 patients with influenza A (H1N1) viral pneumonia and 15 patients, who had isolated bacteria from cultures, those with mixed viral and bacterial pneumonia were significantly more likely to have unilobar consolidations on chest radiographs (53.3 vs. 10.7%, p<0.01) and higher scores of pneumonia severity index (PSI; 90 [66~100] vs. 53 [28~90], p=0.04). Six patients required mechanical ventilation support in an Intensive Care Unit and were more likely to have dyspnea (83.3 vs. 29.3%, p=0.02) and low levels of $PaO_2$ (48.3 [37.0~70.5] vs 64.0 [60.0~74.5] mm Hg, p=0.02) and high levels of pneumonia severity index (PSI) score (108.0 [74.5~142.8] vs. 56.0 [40.5~91.0], p=0.03). Conclusion: The majority of pneumonia patients infected with novel influenza improved. Chest radiographic findings of unilobar consolidations suggest that mixed pneumonia is more likely. Initial dyspnea, hypoxemia, and high levels of PSI score are associated with undergoing mechanical ventilation support.

Performance Effectiveness Case Study of the Machine Guidance System for Dozer Eartwrok Grading Work (도저 정지작업 시 머신 가이던스 시스템 적용에 따른 토공성과 향상 사례분석)

  • Moon, Sungwoo;Kim, Sangtae
    • Korean Journal of Construction Engineering and Management
    • /
    • v.21 no.1
    • /
    • pp.78-86
    • /
    • 2020
  • Dozer is an expensive construction equipment and has a significant performance impact on earthwork performance. A machine guidance system has been applied to dozer equipment as a solution that can improve the performance. The system can provide earthwork-related information to equipment operators so that earthworks can be carried out with minimum support from surveyors. Construction Equipment Machine guidance has the function of supporting earthwork according to an earthwork plan by providing excavation-related information to machine operators. The objective of this study is to evaluate the performance improvement of a machine guidance system for an dozer earthwork operation, and to compare the machine guidance method with the traditional method. The performance has been evaluated in two folds: 1) productivity and 2) accuracy. The productivity shows the quantity of earthwork for a given unit time. The accuracy shows the deviation of grading level from the designed level on the construction drawing for earthwork. The machine guidance system has been applied to a testing bed in a construction site. Data comparison analysis showed that the earth earthwork had 46.59% improvement in productivity as well as 46.96% improvement in accuracy, and is expected to provide a tool for applying smart constrction to the earthwork operation.