• Title/Summary/Keyword: unit group

Search Result 2,805, Processing Time 0.023 seconds

Comparison of Oral Care and Ventilator Circuit on the Reduction of Multi-drug Resistant Infections among Intensive Care Unit Patients (구강간호방법과 인공호흡기회로 종류에 따른 다제내성균 발생률 비교)

  • Shin, Eun Suk;Lee, Gyung Jin;Choi, Eun Jung;Lim, Sung Chul;Lee, Eun Sook
    • Journal of Korean Clinical Nursing Research
    • /
    • v.17 no.2
    • /
    • pp.150-162
    • /
    • 2011
  • Purpose: Multi-drug resistant (MR) infections among intensive care unit (ICU) patients with oral intubation and a ventilator are serious nosocomial infections. This study was done to compare the effects of oral care and ventilator circuit on reduction of MR infections. Methods: A total of 92 participants were recruited from an ICU at C University Hospital in G-city, Korea, assigned to one of 4 groups and evaluated: group I received oral care with sponge and reusable circuit; group II received oral care with tooth brush and reusable circuit; group III received oral care with sponge and disposable circuit; group IV received oral care with tooth brush and disposable circuit. Results: Prevalence rate of MR infections was highest in group I (47.8%), followed by group II (30.4%), group IV (19.0%), and group III (13.6%). Of the four groups, group III showed a significantly decreased MR infections (p=.035) and higher possibility of survival rate as time passes according to survival analysis (p=.019). Conclusion: Results of this study indicate that using disposable ventilator circuit significantly decreases MR infections and raises the possibility of a higher survival rate as time passes. According to this study, the use of disposable ventilator circuit is useful in prevention of MR infections.

A CHARACTERIZATION OF AUTOMORPHISMS OF THE UNIT DISC BY THE POINCARÉ METRIC

  • Kang-Hyurk Lee;Kyu-Bo Moon
    • East Asian mathematical journal
    • /
    • v.39 no.1
    • /
    • pp.11-21
    • /
    • 2023
  • Non-trivial automorphisms of the unit disc in the complex plane can be classified by three classes; elliptic, parabolic and hyperbolic automorphisms. This classification is due to a representation in the projective special linear group of the real field, or in terms of fixed points on the closure of the unit disc. In this paper, we will characterize this classification by the distance function of the Poincaré metric on the interior of the unit disc.

SUBPERMUTABLE SUBGROUPS OF SKEW LINEAR GROUPS AND UNIT GROUPS OF REAL GROUP ALGEBRAS

  • Le, Qui Danh;Nguyen, Trung Nghia;Nguyen, Kim Ngoc
    • Bulletin of the Korean Mathematical Society
    • /
    • v.58 no.1
    • /
    • pp.225-234
    • /
    • 2021
  • Let D be a division ring and n > 1 be an integer. In this paper, it is shown that if D ≠ ��3, then every subpermutable subgroup of the general skew linear group GLn(D) is normal. By applying this result, we show that every subpermutable subgroup of the unit group (ℝG)∗ of the real group algebras RG of finite groups G is normal in (ℝG)∗.

Effects of Kangaroo Care on Physiological Marker of Preterm Infant in Neonatal Intensive Care Unit (캥거루식 접촉이 신생아 집중치료실 미숙아의 생리적 지수에 미치는 효과)

  • Lee, Sang Bok;Shin, Hye Sook
    • Journal of East-West Nursing Research
    • /
    • v.18 no.2
    • /
    • pp.59-65
    • /
    • 2012
  • Purpose: The purpose of this study was to examine the effects of Kangaroo Care (KC) on physiological marker of preterm infant in neonatal intensive care unit (NICU). Methods: The research design was a nonequivalent control group pretest-posttest. Data were collected from July 1, 2007 to February 29, 2008. The participants were 26 people of experimental group and 27 people of control group. KC was applied three times per day, for a total ten times of 4 days to the experimental group. Results: There was significant difference between experimental and control groups on the skin temperature on of preterm infants. The skin temperature in the intervention group was significantly higher than in the control group. Conclusion: Kangaroo care can be applied as a supportive nursing intervention to preterm infant at neonatal intensive care unit.

UN RINGS AND GROUP RINGS

  • Kanchan, Jangra;Dinesh, Udar
    • Bulletin of the Korean Mathematical Society
    • /
    • v.60 no.1
    • /
    • pp.83-91
    • /
    • 2023
  • A ring R is called a UN ring if every non unit of it can be written as product of a unit and a nilpotent element. We obtain results about lifting of conjugate idempotents and unit regular elements modulo an ideal I of a UN ring R. Matrix rings over UN rings are discussed and it is obtained that for a commutative ring R, a matrix ring Mn(R) is UN if and only if R is UN. Lastly, UN group rings are investigated and we obtain the conditions on a group G and a field K for the group algebra KG to be UN. Then we extend the results obtained for KG to the group ring RG over a ring R (which may not necessarily be a field).

The comparison of accuracy on three-unit fixed dental prosthesis made with CAD/CAM milling machines (치과 캐드캠 밀링장비에 따른 3본브릿지의 정확도 비교)

  • Bae, So-Yeon;Park, Jin-Young;Kim, Ji-Hwan;Kim, Hae-Young;Kim, Myung-Bae;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.37 no.1
    • /
    • pp.9-15
    • /
    • 2015
  • Purpose: The purpose of this study was to compare the accuracy of the maxillary three-unit fixed dental prosthesis (FDPs) made using two CAD/CAM milling machines : DCM Group(Dentaim CAD/CAM milling machine), WCM Group(Wieland CAD/CAM milling machine). Methods: Each of 10 duplicate models was scanned by blue light scanner(Identica, Medit, Korea), and the three-unit FDPs (STL file) was designed using DelcamCAD. A total of 20 three-unit FDPs was fabricated, comprising 2 groups of 10 specimens each (shrinkage ratio is 1:1). The first three-unit FDPs STL file was used as a CAD reference model (CRM). Obtained STL files by scanning the inner surface of three-unit FDPs were convened into the point clouds-ASC II files. Discrepancies between the point clouds and CRM were measured by superimposition software. Statistical methods to analyze the data were used non-parametric method. The mean (SD) values were compared by a Mann-Whitney U-test. Type one error rate was set at 0.05. Results: WCM group had small discrepancies with $2.17{\mu}m$ of mean value compared to $4.44{\mu}m$ in DCM group. The accuracy values between the two groups showed a sratistically significant difference (Table 2, p<.05). Conclusion: The accuracy of the three-unit fixed dental prosthesis(FDPs) made of two CAD/CAM milling machines were statistically different. Accuracy with which the prosthesis made of WCM group was superior.

Evaluation of internal adaptation of PMMA 3-unit bridge manufactured by 5-axis milling machine (5축 밀링으로 가공한 PMMA 3본 브릿지의 내면 적합도 평가)

  • Kim, Chong-Myeong;Kim, Jae-Hong;Kim, Ji-Hwan;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.38 no.2
    • /
    • pp.63-68
    • /
    • 2016
  • Purpose: The purpose of this study was to assess the internal fitness of the PMMA 3-unit bridge that was fabricated with 5-axis milling machine and to verify the clinically allowable values. Methods: For fabrication of the crown bridge in this study, 25-27 abutment teeth were used. The prepare abutment teeth were scanned with a scanner and 3-unit bridge was designed by using design software. Upon the completion of the design, the 3-unit bridge was fabricated by using a PMMA block with 5-axis milling machine. The internal surface of the fabricated 3-unit bridge was scanned by using a scanner and the difference between the 3-unit bridge and the abutment teeth was assessed by merging them together. Results: $RMS{\pm}SD$ values for PRE group, MOL group, and BRI group were $51.2{\pm}18.2$, $44.8{\pm}10.0$, and $52.1{\pm}8.3{\mu}m$, respectively. The mean of the PRE group was bigger than that of the MOL and BRI group; however, statistically significant difference was not found (p>0.05). Conclusion: The PMMA 3-unit bridge that was fabricated with 5-axis milling machine presented stable internal values for each crown and overall internal values were within the range of clinically allowable values.

Investigation of Delirium Occurrence and Intervention Status in Intensive Care Unit at a Hospital and Perception of Delirium by Medical Staff (일 종합병원 중환자실의 섬망 발생 및 중재 현황과 의료진의 섬망 인식 조사)

  • Kang, Yi-Seul;Kim, Soon-Hee;Lee, Min-Jeoung;Lee, Hyo-Jin;Lim, Oak-Bun;Hong, Sang-Bum;Choi, Hye-Ran
    • Journal of Korean Critical Care Nursing
    • /
    • v.16 no.1
    • /
    • pp.71-86
    • /
    • 2023
  • Purpose : This study aims to investigate the status of delirium intervention in adult intensive care unit (ICU) patients and the perception of this delirium by medical staff. Methods : This retrospective study involves 185 patients, whereas, a descriptive survey is conducted with 197 medical staff members. Results : The delirium group includes 100 patients (54.1%). The incidence of delirium is 64.9% in the medical ICU, 65.9% in the surgical ICU, 42.4% in the neuro ICU, and 46.5% in the cardiac ICU. The percentages of delirium prevention intervention differs between the two groups: 65.0% in the delirium group and 95.3% in the non-delirium group. The medical staff recognize that delirium is a common problem in the ICU (100.0%) and requires active medical intervention (98.5%). Conclusion : The length of stay at the ICU is longer in the delirium group than in the non-delirium group. It is necessary to standardize delirium prevention and treatment protocols to be equally applicable to all ICU patients.

Research on the Evaluation of Impaired Waterbody using the Flowrate Group at TMDL Unit Watershed in Nakdong River Basin (수질오염총량관리 단위유역 유량그룹별 수체 손상 분석)

  • Hwang, Ha-Sun;Kim, Sang-Soo;Kim, Jin-Lee;Park, Bae-Kyung
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.6
    • /
    • pp.933-942
    • /
    • 2012
  • The purpose of this study is to evaluate the degree of waterbody impairment according to the flow conditions and present to the appropriate water quality improvement alternatives using observed water quality and flow for Total Maximum Daily Load (TMDL) implementation at 39 unit watersheds the nakdong river basin. Observed water quality data for 7 years are divided into five cumulative flow frequency group and comparing the each observed water quality data and TMDL Target water quality (TWQ) the last evaluate the water quality is impaired group. We found that the cumulative flow frequency group-specific the average excess rate of V group was the highest (32.86%), followed by the IV group (26.04%), group III (23.36%), II group (22.67%), I group (20.70%), the degree of impaired waterbody tended to be inversely proportional to the flow rate. Resulted from cumulative flow frequency group of impaired water quality assessment, 13 unit watersheds are impaired from a group IV and group V affected by point sources. Therefore, improvement of sewage discharge and the initial composition of the riparian buffer zone are needed. Nakbon F, Namkang D and Namkang E within 13 unit watersheds are impaired from group II and III affected by non-point sources. Therefore, application of Best Management Practices (BMPs) is needed for these watersheds. Evaluation of impaired waterbody using Cumulative flow frequency group is able to determine the extent of the judgment to TWQ exceeded by the flow conditions and helps proper setting Standard flow and planning pollutant reduction for TMDL.

Functional Outcome after Reimplantation in Patients Treated with and without an Antibiotic-Loaded Cement Spacers for Hip Prosthetic Joint Infections

  • Michele Fiore;Claudia Rondinella;Azzurra Paolucci;Lorenzo Morante;Massimiliano De Paolis;Andrea Sambri
    • Hip & pelvis
    • /
    • v.35 no.1
    • /
    • pp.32-39
    • /
    • 2023
  • Purpose: A staged revision with placement of a temporary antibiotic-loaded cement spacer after removal of the implant is the "gold standard" for treatment of chronic prosthetic joint infection (PJI). It enables local delivery of antibiotics, maintenance of limb-length and mobility, easier reimplantation. However, bacterial colonization of spacers and mechanical complications can also occur. The aim of this study is to evaluate functional results and infection control in two-stage treatment of total hip arthroplasty (THA) PJI with and without a spacer. Materials and Methods: A retrospective review of 64 consecutive patients was conducted: 34 underwent two-stage revision using a cement spacer (group A), 30 underwent two-stage revision without a spacer (group B). At the final follow-up, functional evaluation of patients with a THA in site, without PJI recurrence, was performed using the Harris hip score (HHS). Measurement of limb-length and off-set discrepancies was performed using anteroposterior pelvic X-rays. Results: Most patients in group B were older with more comorbidities preoperatively. Thirty-three patients (97.1%) in group A underwent THA reimplantation versus 22 patients (73.3%) in group B (P<0.001). No significant differences in limb-length and off-set were observed. The results of functional evaluation performed during the final follow-up (mean, 41 months) showed better function in patients in group A (mean HHS, 76.3 vs. 55.9; P<0.001). Conclusion: The use of antibiotic-loaded cement spacer seems superior in terms of functional outcomes and reimplantation rate. Resection arthroplasty might be reserved as a first-stage procedure in patients who are unfit, who might benefit from a definitive procedure.