• Title/Summary/Keyword: transfer structures

Search Result 1,165, Processing Time 0.024 seconds

Effect of Heat-treatment Conditions on Orientation, Structures and Resistances of LaNiO3 Thin Films by Sol-gel process (열처리조건이 LaNiO3 졸-겔 박막의 배향성과 구조 및 저항성에 미치는 영향)

  • 박민석;김대영;서병준;김강언;정수태
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.8
    • /
    • pp.859-865
    • /
    • 2004
  • LaNiO$_3$(LNO) thin films on (100) Si substrates are prepared by sol-gel method on heat treatment conditions, such as heat transfer direction, pyrolysis and annealing process, and annealing temperatures and times. The effect of heat treatment conditions on the (100) orientations, structures and resistances of the thin films are investigated by XRD, SEM(FESEM), and a lout probe method. Highly (100) orientation factor(0.97), a pseudocubic crystalline structure with a dense and uniform microstructure could be formed by the following conditions: 1) the heat transfer direction is from Si substrate to LNO, 2) the pyrolysis and annealing process are alternated, 3) the annealing temperature is $650^{\circ}C$ and 4) the annealing times is 3 minutes. The sheet resistance of thin films decreased with increasing of a annealing temperature and time, and a number of coating.

Estimation of Group Walking Loads by System Identification of Building Structures (건축구조물의 시스템 식별을 통한 무리보행하중 평가)

  • 김태호;민경원;이동근
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.1
    • /
    • pp.65-72
    • /
    • 2003
  • The objective of this study is to estimate the frequency characteristics of group walking loads based on the information of measured responses. At first, dynamic properties such as natural frequencies and modes are obtained from input/output relation for building structures by heel drop test. Second, a method to estimate group walking loads by the transfer functions from measured responses to group walking loads is proposed. The method turned out to estimate the group walking loads accurately. Higher modes could be important in estimating the amplitude of group walking loads with the information of single walking load.

Unusual Necrotizing Uterine Adenocarcinoma in a Dog

  • Kim, Tae-Jung;Shin, Sung-Shik;Park, Sang-Ik
    • Journal of Embryo Transfer
    • /
    • v.32 no.4
    • /
    • pp.325-329
    • /
    • 2017
  • A 2-year-old female Maltese dog was admitted with a history of pyometra and resulting peritonitis and septicemia. Uterine specimen sampled by ovariohysterectomy was processed routinely for histopathological observation. Grossly, the uterine mucosa was covered with necrotic debris and on the cut surface, lesion extended into the uterine wall. Microscopically, severe necrosis was observed throughout thickened mucosa, submucosa, and wall of uterus. Tumorous lesions composed of anaplastic cells with bizarre nuclei or tubular structures of cuboidal to short columnar cells were infrequently observed around the necrotic lesions and muscular layer far from necrotic areas. Immunohistochemically, central necrotic area with ambiguous cell and tissue structures, peri-necrotic tumor lesions, and muscular layer were strongly positive for cytokeratin. Since huge necrosis of adenocarcinoma lesions in this case made it difficult to diagnose, immunohistochemical results enable to diagnose as a severe necrotizing adenocarcinoma. Thus, histopathological and immunohistochemical findings in this case may serve as an important knowledge to diagnose uterine adenocarcinoma with huge necrosis in the veterinary field.

Passive control of seismically excited structures by the liquid column vibration absorber

  • Konar, Tanmoy;Ghosh, Aparna Dey
    • Structural Engineering and Mechanics
    • /
    • v.36 no.5
    • /
    • pp.561-573
    • /
    • 2010
  • The potential of the liquid column vibration absorber (LCVA) as a seismic vibration control device for structures has been explored in this paper. In this work, the structure has been modeled as a linear, viscously damped single-degree-of-freedom (SDOF) system. The governing differential equations of motion for the damper liquid and for the coupled structure-LCVA system have been derived from dynamic equilibrium. The nonlinear orifice damping in the LCVA has been linearized by a stochastic equivalent linearization technique. A transfer function formulation for the structure-LCVA system has been presented. The design parameters of the LCVA have been identified and by applying the transfer function formulation the optimum combination of these parameters has been determined to obtain the most efficient control performance of the LCVA in terms of the reduction in the root-mean-square (r.m.s.) displacement response of the structure. The study has been carried out for an example structure subjected to base input characterized by a white noise power spectral density function (PSDF). The sensitivity of the performance of the LCVA to the coefficient of head loss and to the tuning ratio have also been examined and compared with that of the liquid column damper (LCD). Finally, a simulation study has been carried out with a recorded accelerogram, to demonstrate the effectiveness of the LCVA.

Wireless Power Receiving System Implemented on a Flexible Substrate for Wearable Device Applications (웨어러블 기기 응용을 위한 플렉서블 무선 전력 수신 시스템)

  • Lee, Yongwan;Lim, Jongsik;Han, Sang-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.5
    • /
    • pp.739-745
    • /
    • 2015
  • In this paper, a flexible wireless power receiving system is proposed for wearable device applications. The proposed system is designed with printable component configuration to be integrable to textile material. While the defected ground structures(DGSs) are utilized for planar printable filter designs, direct impedance matching technique is considered for flexible circuit performance. The proposed system has been implemented on a flexible substrate with a thickness of 5 mils, and experimented for power conversion efficiencies and converted voltages. In order to evaluate the hardware flexibility, the system performance are measured a bended circuit board at a radius of curvature of 5 cm. The system performance is analyzed for the degradation due to the curvature. The proposed system has shown the excellent capability of far-field wireless power transfer systems in flexible device environments.

Structures of Ammonia Cluster Cations

  • 박종근
    • Bulletin of the Korean Chemical Society
    • /
    • v.20 no.9
    • /
    • pp.1067-1072
    • /
    • 1999
  • Structures of unprotonated [(NH3)n+(n = 1-6)] and protonated [NH4+(NH3)n-1(n = 1-6)] ammonia cluster cations have been optimized with ab initio Hartree-Fock (HF) and second-order MФller-Plesset (MP2)/6-31+G ** levels and the harmonic vibrational frequencies have also been evaluated. In unprotonated cluster cations, NH3+ forms as a central core of the first ammonia solvation shell. In protonated cluster cations, NH4+ forms as a central core. In unprotonated dimer and trimer cations, there are two types of isomers (hydrogen-bonded and head-to-head interactions). In both cluster cations, the hydrogen-bonded isomers are more stable. In the hydrogen-bonded dimer cation, the proton transfer reaction takes place from (NH3-HN+H2) to (NH4+-NH2). But in the other unprotonated cluster cations, the proton transfer does not take place. In unprotonated pentamer and hexamer, a NH3+ core has both interactions in a complex. On the other hand, in unprotonated tetramer a core has only the hydrogen-bonded type combined with neutral ammonia molecules. With increasing cluster cation size, the bond lengths [R(NN)] between two nitrogen atoms and the distances [R(N ...H)] of the hydrogen-bond increase reg-ularly. In the calculated infra-red absorption bands for ammonia cluster cations, the characteristic peaks of the bridged NH vibration of the hydrogen-bonded clusters appear near 2500 cm-1 . With increasing size, the peaks shift from 2306 cm-1 to 2780 cm-1 .

Density Functional Theory Studies on the Electrophilic versus Electron Transfer Mechanisms of Aryl Vinyl Ethers

  • 김왕기;손창국;임선희;이순기;김창곤;이익춘
    • Bulletin of the Korean Chemical Society
    • /
    • v.20 no.10
    • /
    • pp.1177-1180
    • /
    • 1999
  • The ab initio SCF MO and density functional theory (DFT) studies are carried out on the electrophilic (1a) and electron transfer (1b) addition reactions to the vinyl double bond of aryl vinyl sulfides and ethers. In the electrophilic addition processes, a double bond shift from C3 = C4 to X = C3 occurs with occupation number (1.97) close to the normal two. Due to this shift direct conjugation between the cationic center, X = S or O, and the para electron-donor substituent becomes impossible so that the reaction energies (or log K) are correlated with σ rather than σ+. By contrast, radical cation formation leads to delocalization of the SOMO, a lone-pair πorbital on X, with four major resonance structures in which cationic charge as well as spin density is delocalized over C4 , X and C7 atoms. As a result, partial πbonds are formed over C1 -X and C3 - C4 with occupation numbers (0.82) lower than one. In two of the cannonical structures, III(Ⅹ) and III(X+), direct conjugation between the cationic center, X, and the para substituent is achieved so that a better correlation with σ+ rather than σis obtained. The SCF MO energies at the HF/3-21G* and HF/6-31G* levels lead to very much inferior Hammett correlations in the σ/ σ+ diagnostic criterion. In contrast, the ρvalues evaluated with the DFT energies can give reliable diagnostic distinction between the two addition mechanisms.

An Experimental Study on the Performance of One-Way Slab Using Unbonded Post-Tensioned Anchorage for Single Tendon (비부착식 단일 강연선용 원형 정착구의 일방향 슬래브 적용에 관한 실험적 연구)

  • Kim, Min Sook;Ro, Kyong Min;Lee, Young Hak
    • Journal of Korean Association for Spatial Structures
    • /
    • v.19 no.1
    • /
    • pp.45-51
    • /
    • 2019
  • In this study, the static load test and the load transfer test were carried out to evaluate the structural performance of the circular anchorage proposed by the previous study. Specimens were fabricated according to KCI-PS101 and ETAG 013. As a result of the static load test, it was verified that the displacement of the wedge and the strand was kept constant when the tensile force of 80% of the nominal strength of the strand was applied. In the load transfer test, it was confirmed that all the specimens satisfied the stabilization formula of KCI-PS101 and ETAG 013. Post-tensioned one-way slab with circular anchorage were fabricated to evaluate the flexural behavior. All specimens exhibited the same flexural behavior and maximum load. However, the specimen with circular anchorage were advantageous than the rectangular anchorage one in terms of crack control of the anchorage zone.

A Study on Polymer Replica Materials for Nanotransfer Printing (패턴전사프린팅용 고분자 복제 소재 연구)

  • Kang, Young Lim;Park, Woon Ik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.4
    • /
    • pp.262-268
    • /
    • 2021
  • For the past several decades, various next-generation patterning methods have been developed to obtain well-designed nano-to-micro structures, such as imprint lithography, nanotransfer printing (nTP), directed self-assembly (DSA), E-beam lithography, and so on. Especially, nTP process has much attention due to its low processing cost, short processing time, and good compatibility with other patterning techniques in achieving the formation of high-resolution functional patterns. To transfer functional patterns onto desirable substrates, the use of soft materials is required for precise replication of master mold. Here, we introduce a simple and practical nTP method to create highly ordered structures using various polymeric replica materials. We found that polymethyl methacrylate (PMMA), polystyrene (PS), and polyvinylpyridine (PVP) are possible candidates for replica materials for reliable duplication of Si master mold based on systematic analysis of pattern visualization. Furthermore, we successfully obtained well-defined metal and oxide nanostructures with functionality on target substrates by using replica patterns, through deposition and transfer process. We expect that the several candidates of replica materials can be exploited for effective nanofabrication of complex electronic devices.

Analysis of Indeterminate Truss Structures by Element-Focused Network Approach (요소 중심의 네트워크 접근법을 이용한 부정정 트러스 구조 해석)

  • Han, Yicheol
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.58 no.3
    • /
    • pp.13-19
    • /
    • 2016
  • Element-focused network analysis method for truss structure is proposed. The propagation process of loads from external loads to connected other elements is similar to that of connections between nodes in accordance with attachment rule in a network. Here nodes indicate elements in a truss structure and edges represent propagated loads. Therefore, the flows of loads in a truss structure can be calculated using the network analysis method, and consequently the structure can also be analyzed. As a first step to analyze a truss structure as a network, we propose a local load transfer rule in accordance with the topology of elements, and then analyze the loads of the truss elements. Application of this method reveal that the internal loads and reactions caused by external loads can be accurately estimated. Consequently, truss structures can be considered as networks and network analysis method can be applied to further complex truss structures.