DOI QR코드

DOI QR Code

An Experimental Study on the Performance of One-Way Slab Using Unbonded Post-Tensioned Anchorage for Single Tendon

비부착식 단일 강연선용 원형 정착구의 일방향 슬래브 적용에 관한 실험적 연구

  • 김민숙 (경희대학교 건축공학과) ;
  • 노경민 (경희대학교 건축공학과 대학원) ;
  • 이영학 (경희대학교 건축공학과)
  • Received : 2018.10.11
  • Accepted : 2018.11.12
  • Published : 2019.03.15

Abstract

In this study, the static load test and the load transfer test were carried out to evaluate the structural performance of the circular anchorage proposed by the previous study. Specimens were fabricated according to KCI-PS101 and ETAG 013. As a result of the static load test, it was verified that the displacement of the wedge and the strand was kept constant when the tensile force of 80% of the nominal strength of the strand was applied. In the load transfer test, it was confirmed that all the specimens satisfied the stabilization formula of KCI-PS101 and ETAG 013. Post-tensioned one-way slab with circular anchorage were fabricated to evaluate the flexural behavior. All specimens exhibited the same flexural behavior and maximum load. However, the specimen with circular anchorage were advantageous than the rectangular anchorage one in terms of crack control of the anchorage zone.

Keywords

References

  1. Park, S. S., & Lim, D. H., "Anchorage Zone Design of Precast Prestressed Concrete Structures", Journal of the Architectural Institute of Korea, Vol.10, No.10, pp.199-206, 1994
  2. Lee, D. H., & Kim, K. S., "Ultimate Stress of Unbonded Tendons in Post-Tensioned Flexural Members", Journal of the Korea Concrete Institute, Vol.21, No.4, pp.489-499, 2009 https://doi.org/10.4334/JKCI.2009.21.4.489
  3. Cho, A. S., Jo, Y. W., Jeon, B. K., & Kang, T. H. K., "Development and Performance Test for Unbonded Post-Tensioned Anchor", Journal of the Korea Concrete Institute, Vol.27, No.1, pp.11-20, 2015 https://doi.org/10.4334/JKCI.2015.27.1.011
  4. Kim, B. J., & Kim, H. G., "Load transfer test of circular anchorage system according to ETAG 013", Journal of the Korea Academia-Industrial cooperation Society, Vol.19, No.5, pp.167-175, 2018 https://doi.org/10.5762/KAIS.2018.19.5.167
  5. Lee, Y. H., Cho, Y. W., & Kim, M. S., "Development and Analysis of Unbonded Post-tensioned Anchorage for Single Tendon", Journal of the Computational Structural Engineering Institute of Korea, Vol.31, No.1, pp.39-46, 2018 https://doi.org/10.7734/COSEIK.2018.31.1.39
  6. Korea concrete institute, Proposed standard of Korea concrete institute, Review of Korea concrete institute, Seoul, 2016, pp.215
  7. EOTA, Guideline for European Technical Approval of Post-Tensioning Kits for Prestressing of Structures (ETAG 013), European Organisation for Technical Approvals, Belgium, 2002, pp.136