Characteristics of Ti-SPAC as Fluidizing Phase Photocatalyst (Ti-구형활성탄의 유동상 광촉매 특성 평가)

  • Lee, Joon-Jae;Suh, Jeong-Kwon;Hong, Ji-Sook;Park, Jin-Won;Lee, Jung-Min
    • Korean Chemical Engineering Research
    • /
    • v.44 no.4
    • /
    • pp.375-381
    • /
    • 2006
  • In this sturdy, spherical activated carbon(SPAC) contained $TiO_2$ was made by ion-exchanged treatment and heat treatment for applying fluidizing bed system. The ion-exchange resin was treated by $TiCl_3$ aqueous solution. The treated resin and raw resin were heat-treated under nitrogen condition to convert into Ti-SPAC. During the heat-treatment, burn-off weight amounts and the element were measured by means of TGA and TGA/MS, individually. The physicochemical properties of Ti-SPAC was characterized by means of XRD, SEM, EDS, BET, EPMA, ESR, intensity and titanium content. The Ti-SPAC had spherical shape with diameter size about $350{\mu}m{\sim}400{\mu}m$ and $617m^2/g$ specific surface area. Structure of $TiO_2$ in Ti-SPAC was anatase and rutile form. Also, $TiO_2$ on SPAC were found that the $TiO_2$ were uniformly distributed through EPMA analysis. Moreover, the Ti-SPAC showed indirect photocatalyst activity estimation through ESR analysis, characteristics of photocatalyst potentially. Over all results, Ti-SPAC was used in fluidizing bed UV/photocatalyst system to remove HA(Humic Acid). That results were HA removal efficiency was about 70% and Ti-SPAC intensity was preserved during reaction. Ti-SPAC showed practical possibility as photocatalyst in fluidizing bed system.

Removal Torque of Mg-ion Implanted Clinical Implants with Plasma Source Ion Implantation Method (마그네슘 이온주입 임플란트의 뒤틀림 제거력에 관한 연구)

  • Kim, Bo-Hyoun;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.1
    • /
    • pp.41-52
    • /
    • 2009
  • The surface treatment of titanium implant could bring out the biochemical bonding between bone and implant. The purpose of this study was to evaluate the biomechanical bone response of Mg-ion implanted implants with plasma source ion implantation method. Twelve New Zealand white rabbits were included in this study. Each rabbit received one control fixture (blasted with resorbable blasting media, RBM) and three types of Mg ion implanted fixtures in tibiae. The implants were left in place for 6 weeks before the rabbits were sacrificed. Removal torque value and resonance frequency analysis (ISQ) were compared. The repeated measured analysis of variance was used with $P{\leq}0.05$ as level of statistical significance. ISQ was not different among all groups. However, the ISQ was increased after 6 weeks healing. The group had lowest ISQ value showed the greatest increment. Mg-1 implants with 9.4% retained ion dose showed significantly higher removal torque value than that of the other implants. From this results, it is concluded that the Mg-1 implants has stronger bone response than control RBM surface implant.

The Etching Characteristics of (Ba0.6Sr0.4)TiO3 films Using Ar/CF4 Inductively Coupled Plasma (Ar/CF4 유도결합 플라즈마를 이용한 (Ba0.6Sr0.4)TiO3 박막의 식각 특성)

  • 강필승;김경태;김동표;김창일;이수재
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.11
    • /
    • pp.933-938
    • /
    • 2002
  • (Ba,Sr)TiO$_{4}$ (BST) thin films on Pt/Ti/SiO$_{2}$/Si substrates were deposited by a sol-gel method and the etch characteristics of BST thin films have been investigated as a function of gas mixing ratio. The maximum etch rate of the BST films was 440 $AA$/min under such conditions as: CF$_{4}$(CF$_{4}$+Ar) of 0.2, RF-power of 700 W, DC-bias voltage of -200 V, pressure of 15 mTorr and substrate temperature of 30 $^{circ}C$. The selectivities of BST to Pt, SiO$_{2}$ and PR were 0.38, 0.25 and 0.09, respectively. In the XPS (X-ray photoelectron spectroscopy) analysis, Barium (Ba) and Strontium (Sr) component in BST thin films formed low volatile compounds such as BaFx, SrFx, which are forms by the chemical reaction with F atoms and is removed by Ar ion bombardment. Titanium (Ti) is removed by chemical reaction such as TiF with ease. The result of secondary ion mass spectrometry (SIMS) analysis confirmed the existence of the BaFx, SrFK, TiFx.

Development of LiFePO4/FePO4 Electrode for Electro-Osmotic Pump using Li+ Migration

  • Baek, Jaewook;Kim, Kyeonghyeon;Shin, Woonsup
    • Journal of Electrochemical Science and Technology
    • /
    • v.9 no.2
    • /
    • pp.85-92
    • /
    • 2018
  • Olivine structure of $LiFePO_4$ (LFP) is one of the most commonly used materials in aqueous rechargeable lithium batteries (ARLBs), and can store and release charge through the insertion/de-insertion of $Li^+$ between LFP and FP. We have fabricated LFP and LFP/FP electrodes on titanium paper and studied their electrochemical properties in 2 M $Li_2SO_4$. The LFP/FP electrode was determined to be a suitable electrode for electo-ostmotic pump (EOP) in terms of efficiency in water and 0.5 mM $Li_2SO_4$ solution. Experiments to determine the effect of cations and anions on the performance of EOP using LFP/FP electrode have shown that $Li^+$ is the best cation and that the anion does not significantly affect the performance of the EOP. As the concentration of $Li_2SO_4$ solution was increased, the current increased. The flow rate peaked at $4.8{\mu}L/30s$ in 1.0 mM $Li_2SO_4$ solution and then decreased. When the EOP was tested continuously in 1.0 mM $Li_2SO_4$ solution, the EOP transported approximately 35 mL of fluid while maintaining a stable flow rate and current for 144 h.

Effect of $Li_4Ti_5O_{12}$ coating layer on capacity retention of $LiMn_2O_4$ as cathode materials of lithium ion secondary batteries for HEV application (HEV용 리튬 이차전지 양극물질 $LiMn_2O_4$$Li_4Ti_5O_{12}$ 코팅에 따른 영향)

  • Wai, Yin-Loo;Choi, Byung-Hyun;Jee, Mi-Jung;Lee, Dae-Jin;Shin, Jae-Su;Song, Kwang-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.125-128
    • /
    • 2007
  • In these recent years, low cost and stable battery electrode materials have been studied for HV/HEV application. Spinel cathode material $LiMn_2O_4$ is widely studied as a promising cathode material of lithium ion secondary batteries because of it is low cost, easily to be prepared and capable to be operated in high voltage range. In this study, $LiMn_2O_4$ was undergoing surface modification with spinel lithium titanium oxide by sol-gel method in order to enhance its capacity retention. Properties of both unmodified and surface-modified $LiMn_2O_4$ were characterized by XRD, SEM, particle size analyzer while their cycling performance was tested with charge and discharge tester.

  • PDF

Study for Electro-optic Properties of PZT Ceramics (PZT 세라믹의 전기광학적 특성에 관한 연구)

  • Kim Si-Joong;Kim Kun;Ahn Byeung-Joon
    • Journal of the Korean Chemical Society
    • /
    • v.36 no.1
    • /
    • pp.51-56
    • /
    • 1992
  • X-ray diffraction analysis and infrared spectrophotometry were used to investigate the crystal structures and the bonding characteristics in $Pb(Zr_{1-y}Ti_y)O_3$ (PNZT), which has a perovskite structure. As $Pb^{2+}$ of PZT was substituted by 8${\sim}$12 atom% $Nd^{3+}$ ion, the structures were changed to cubic from tetragonal and its transmission had maximum value. Transmission increased as the stretching force constant $(k_s)$ of unit cell increased. It is supposed that the electro-optic characteristics might occur due to electron-transition from HOMO to LUMO of titanium ion.

  • PDF

Structure Analysis of TiO Film on the MgO(001) Surface by Time-Of-Flight Impact-Collision Ion Scattering Spectroscopy (비행시간형 직층돌 이온산란 분광법을 사용한 MgO(001) 면에 성장된 TiO막의 구조해석)

  • Hwang, Yeon;Lee, Tae-Kun;Park, Byung-Kyu
    • Korean Journal of Crystallography
    • /
    • v.13 no.2
    • /
    • pp.57-62
    • /
    • 2002
  • Time-of-flight impact-collision ion scattering spectroscopy (TOF-ICISS) was applied to study the geometrical structure of epitaxially grown TiO layers on a MgO(001) surface. The hetero-epitaxial TiO layer was deposited by thermal evaporation of titanium onto the MgO(001) surface and subsequent exposure to oxygen at 400℃. The well-ordered TiO structure was confirmed with the 1×1 RHEED pattern. TOF-ICISS results revealed that the TiO layer was formed at the on-top sites of the MgO(001) substrate and that the lateral lattice constant of TiO layer was the same as that of the MgO substrate. The surface of the deposited epitaxial TiO layer was smooth without the three dimensional islands.

Effects of CrN and TiN Coating by Hydrogen Embrittlement of Aluminum Alloys for Hydrogen Valves of Hydrogen Fuel Cell Vehicles on Mechanical Properties (수소연료전지 자동차의 수소밸브용 알루미늄 합금의 수소취화에 의한 기계적 특성에 미치는 CrN과 TiN 코팅의 영향)

  • Ho-Seong Heo;Dong-Ho Shin;Seong-Jong Kim
    • Corrosion Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.232-241
    • /
    • 2023
  • The mechanical properties of the hydrogen valve responsible for supplying and blocking hydrogen gas in a hydrogen fuel cell electric vehicle (FCEV) were researched. Mechanical properties by hydrogen embrittlement were investigated by coating chromium nitride (CrN) and titanium nitride (TiN) on aluminum alloy by arc ion plating method. The coating layer was deposited to a thickness of about 2 ㎛, and a slow strain rate test (SSRT) was conducted after hydrogen embrittlement to determine the hydrogen embrittlement resistance of the CrN and TiN coating layers. The CrN-coated specimen presented little decrease in mechanical properties until 12 hours of hydrogen charging due to its excellent resistance to hydrogen permeation. However, both the CrN and TiN-coated specimens exhibited deterioration in mechanical properties due to the peeling of the coating layer after 24 hours of hydrogen charging. The specimens coated at 350 ℃ presented a significant decrease in ultimate tensile strength due to abnormal grain growth.

Characteristics of Fluoride Releasing of Anodized Titanium Implant (양극산화 아크방전 처리한 티타늄 임플란트의 불소방출 특성)

  • Kim, Ha-young;Song, Kwang-yeob;Bae, Tae-sung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.4
    • /
    • pp.361-369
    • /
    • 2008
  • The purpose of this study is to make porous oxide film on the surfaces of pure Ti through anodic spark discharge in electrolytic solution containing calcium and phosphate ions, to improve osseointergration by treating fluoride agent. In addition, it is to evaluate the fluoride modified effect on the surface. Commercial pure Ti plate with $20{\times}10{\times}2mm$ and Ti wire with a diameter of 1.5mm and a total length of 15mm were used. After making titanium oxide films converted by anodic spark discharge, anodizing was performed. Fluoride was spreaded to titanium laboratory plate and maintained for 30 minutes after anodizing breakdown. Fluoride ion discharge amount was measured per 24 hours after dipping titanium plate into saline (10ml) and sustaining 90rpm in a pyrostat. Some plates and wires were dipped in Hanks solutions for a month to examine biocompatibility using SEM and XRD. $TiO_2$ film formed by anodic discharge technique showed great roughness and uniform pores which were $1{\sim}3{\mu}m$ in a diameter. Roughness of the films treated with anodic discharge after blasting were higher than the turned ones(P<0.05). Rapid surface activity was observed in the samples treated with $TiF_3$ agent, which immersed in Hanks solution for 30 days. Taking the results into consideration, the fluoride modified implant with anodic discharge demonstrates that it makes uniformly porous oxide film on the surface of implant and properly increase roughness for osseointegration. The implants will achieve greater bone integration after short healing time by improving surface activity.

Adsorptive Removal of Cu(II), Pb(II), and Hg(II) Ions from Common Surface Water Using Cellulose Fiber-Based Filter Media

  • Phani Brahma Somayajulu Rallapalli;Jeong Hyub Ha
    • Applied Chemistry for Engineering
    • /
    • v.35 no.4
    • /
    • pp.352-359
    • /
    • 2024
  • Environmental pollution from heavy metal ions (HMIs) is a global concern. Recently, biosorption methods using cellulose sorbents have gained popularity. The objective of this study was to assess the removal efficiency of Cu(II), Pb(II), and Hg(II) ions at low concentration levels (100-700 ppb) from aqueous solutions using three different cellulose fiber-based filter media. Sample A was pure cellulose fiber, Sample B was 10% activated carbon-cellulose fiber, and Sample C was cellulose fiber-glass fiber-30% activated carbon-20% amorphous titanium silicate (ATS). The samples were characterized by several physicochemical techniques. The porosity measurements using N2 sorption isotherms revealed that Samples A and B are nonporous or macroporous materials, whereas the addition of 50% filler materials into the cellulose resulted in a microporous material. The Brunauer-Emmett-Teller (BET) surface area and pore volume of Sample C were found to be 320.34 m2/g and 0.162 cm3/g, respectively. The single ion batch adsorption experiments reveal that at 700 ppb initial metal ion concentration, Sample A had removal efficiencies of 7.5, 11.5, and 13.7% for Cu(II), Pb(II), and Hg(II) ions, respectively. Sample B effectively eliminated 99.6% of Cu(II) ions compared to Pb(II) (14.2%) and Hg(II) (31.9%) ions. Cu(II) (99.37%) and Pb(II) (96.3%) ions are more efficiently removed by Sample C than Hg(II) (68.2%) ions. The X-ray photoelectron spectroscopy (XPS) wild survey spectrum revealed the presence of Cu(II), Pb(II), and Hg(II) ions in HMI-adsorbed filter media. The high-resolution C1s spectra of Samples A and B reveal the presence of -C-OH and -COOH groups on their surface, which are essential for HMIs adsorption via complexation reactions. Additionally, the ATS in Sample C facilitates the adsorption of Pb(II) and Hg(II) ions through ion exchange.