• 제목/요약/키워드: time-controlled

검색결과 4,535건 처리시간 0.031초

A Pilot Study on the Control Performance of Foot-Controlled Mouse Devices for the Nondisabled People

  • Hong, Seung Kweon
    • 대한인간공학회지
    • /
    • 제35권3호
    • /
    • pp.175-184
    • /
    • 2016
  • Objective: In this study, two types of foot-controlled mouse devices are compared with a hand mouse in the input tasks requiring repetitively switching between a keyboard and a mouse. Background: Foot-controlled mouse devices have been developed for persons with impairments in the mobility of their hands. However, some researchers insisted that the foot-controlled mouse devices could be effectively used by the persons with no limits to their hand mobility. There are needs to investigate the efficiency of the foot-controlled mouse devices, when they are used by the nondisabled people. Method: Participants conducted the input tasks, requiring repetitive switches between a keyboard and a computer mouse. The used computer mouse devices were two types of foot-controlled mouse and a typical hand mouse. Participants performed three types of input task for five days and three types of task performance were measured; the number of completed input tasks within a given practice time, subjective satisfaction level and the time wasted for the mouse control. Results: For five days, the performance of input tasks sharply increased in input tasks by foot-controlled mouse devices rather than a hand mouse. After five days, the level of satisfaction on the foot-controlled mouse devices approached to about 76% of a hand mouse satisfaction level. The control time of the foot-controlled mouse devices also approached to about 109% of a hand mouse control time. Conclusion: After only five-day practice, the input task performance by foot-controlled mouse devices approached to that of a hand mouse. This result may suggest that the foot-controlled mouse devices can be effectively used as an alternative input device for the nondisabled people, if input tasks are easy and enough practice time is provided. Application: The results of this study might help to design foot-controlled mouse devices and to expend the usage of them.

A Study on the Reliability of DVR in a 3-Phase Phase-Controlled Rectifier

  • Kim, Woo-Hyun;Park, Chul-Woo
    • 조명전기설비학회논문지
    • /
    • 제26권11호
    • /
    • pp.54-61
    • /
    • 2012
  • This study investigated the relationship between the response time of DVR (Dynamic Voltage Restorer) and the possible compensation range for voltage dips by the DVR system which protects the 3-phase phase-controlled rectifier from said dips. As a result, the permissible range of voltage dip is presented in a 3-phase phase-controlled rectifier. When the DVR compensates for voltage dip, the range of voltage dip can be compensated according to the DVR's response time. Using the proposed method, DVR response time can be determined from the parameters of the 3-phase phase-controlled rectifier and the possible compensatory range of voltage dip, while at the same time it is possible to use a control system having an appropriate speed. Therefore, the use of excessively fast equipment can be avoided, improving the stability of the overall system. The reliability of the DVR concerning the 3-phase phase-controlled rectifier can be verified by simulation.

Influence of time delay and saturation capacity to the response of controlled structures under earthquake excitations

  • Pnevmatikos, Nikos G.;Gantes, Charis J.
    • Smart Structures and Systems
    • /
    • 제8권5호
    • /
    • pp.449-470
    • /
    • 2011
  • During the last thirty years many structural control concepts have been proposed for the reduction of the structural response caused by earthquake excitations. Their research and implementation in practice have shown that seismic control of structures has a lot of potential but also many limitations. In this paper the importance of two practical issues, time delay and saturation effect, on the performance of controlled structures, is discussed. Their influence, both separately and in interaction, on the response of structures controlled by a modified pole placement algorithm is investigated. Characteristic buildings controlled by this algorithm and subjected to dynamic loads, such as harmonic signals and actual seismic events, are analyzed for a range of levels of time delay and saturation capacity of the control devices. The response reduction surfaces for the combined influence of time delay and force saturation of the controlled buildings are obtained. Conclusions regarding the choice of the control system and the desired properties of the control devices are drawn.

3상 위상제어 정류기에서 DVR의 응답시간과 허용 가능한 순시저전압의 범위에 대한 연구 (A study on the permissible range of voltage dips and the response time of DVR in 3-phase phase-controlled rectifier)

  • 한무호;권우현;박철우
    • 제어로봇시스템학회논문지
    • /
    • 제10권4호
    • /
    • pp.325-333
    • /
    • 2004
  • It is investigated that the relation between the response time of DVR(Dynamic Voltage Restorer) and the possible compensation range of voltage dip by the DVR system which protects the 3-phase phase-controlled rectifier from voltage dip. As a result, the permissible range of voltage dip is presented in the 3-phase phase-controlled rectifier, and it is presented that the range of voltage dip which can be compensated according to the DVR s response time. when the DVR compensates voltage dip, Using the proposed method, the DVR s response time can be determined from the parameters of 3-phase phase-controlled rectifier and the possible compensation range of voltage dip, and it is possible to use the control system which have an appropriate speed. Therefore, the use of excessively fast device can be avoided, and the stability of the overall system is improved. Also the reliance of DVR about the 3-phase phase-controlled rectifier can be verified.

빠른 Lock-Time을 위한 다중 이득 제어 디지털 위상 주파수 검출기 (A Multiple Gain Controlled Digital Phase and Frequency Detector for Fast Lock-Time)

  • 홍종필
    • 전자공학회논문지
    • /
    • 제51권2호
    • /
    • pp.46-52
    • /
    • 2014
  • 본 논문은 다중 이득 제어를 통하여 빠른 lock-time을 갖는 디지털 위상 주파수 검출기 회로를 제안한다. 기준신호와 피드백 신호의 위상 차이가 클 때, 위상 차이가 적으면서 lock에 근접했을 때, lock 이후의 세 경우에 따라 디지털 위상 동기 루프의 이득을 다르게 설정하여 lock-time을 효과적으로 줄일 수 있다. 시뮬레이션 결과를 통해 제안된 기법을 적용함으로써 기존의 단일 이득 제어 구조보다 lock-time을 약 100배 개선시킬 수 있음을 확인하였다.

가변구조 적응모델 추종제어 시스템에 관한 연구 (A Study on the Variable Structure Adaptive Model Following Control Systems)

  • 허노재;최종문;한만춘
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1983년도 하계학술회의강연.논문초록집
    • /
    • pp.135-138
    • /
    • 1983
  • This paper studies a variable structure adaptive model following control system which can control a plant in which the parameters of the controlled plant can not be estimated because they vary with time and in which the controlled plant has noise. The values of the feedback gain matrices for given states are obtained the equivalent control law, and the adaptive controller has been designed using the adaptive mechanism which switches the matrices. The adaptive controller minimizes the state error vector, that is, the difference between the state vector of the model and the state vector of the controlled plant. A controlled plant which has time varying parameters, a controlled plant which has only noise, and a controlled plant which has both have been controlled by the designed adaptive controller. The continuous single input-output system has been analysed by computer. This control system may be used to control practical systems by the addition of a microcomputer.

  • PDF

3상 위상제어 정류기를 위한 DVR의 반응시간 최적화 (Response Time Optimization of DVR for 3-Phase Phase-Controlled Rectifier)

  • 박철우;정수경;류지열;이대섭
    • 제어로봇시스템학회논문지
    • /
    • 제19권3호
    • /
    • pp.195-201
    • /
    • 2013
  • In this paper, we present optimization technique for the response time of DVR (Dynamic Voltage Restorer) and the possible compensation range of voltage dip by the DVR system. To protect 3-phase phase-controlled rectifier from voltage dip, DVR system needs to have optimum response time as an important design factor. Although the fast response time of DVR ensures wider range of voltage dip, DVR controller has so high cost and poor stability. This paper proposes DVR system with optimum response time required for certain intensity of voltage dips and good stability to support possible compensation range of voltage dip. Proposed technique showed optimum response time and good stability for overall system. We believe that proposed technique is reliable and useful in DVR design.

Sliding Mode Control for Attitude Tracking of Thruster-Controlled Spacecraft

  • Cheon, Yee-Jin
    • Transactions on Control, Automation and Systems Engineering
    • /
    • 제3권4호
    • /
    • pp.257-261
    • /
    • 2001
  • Nonlinear pulse width modulation (PWM) controlled system is considered to achieve control performance of thruster controlled spacecraft. The actual PWM controlled motions occur, very closely, around the average model trajectory. Furthermore nonlinear PWM controller design can be directly applied to thruster controlled spacecraft to determine thruster on-time. Sliding mode control for attitude tracking of three-axis thruster-controlled spacecraft is presented. Simulation results are shown which use modified Rodrigues parameters and sliding mode control law to achieve attitude tracking of a three-axis spacecraft with thrusters.

  • PDF

Sliding Mode Control for Attitude Tracking of Thruster-Controlled Spacecraft

  • Cheon, Yee-Jin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.461-461
    • /
    • 2000
  • Nonlinear pulse width modulation(PWM) controlled system is considered to achieve control performance of thruster-controlled spacecraft. The actual PWM controlled motions occurs, very closely, around the average model rajectory. Furthermore nonlinear PWM controller design can be directly applied to thruster controlled spacecraft to determine thruster on-time. Sliding mode control for attitude tracking of three-axis thruster-controlled spacecraft is presented. Simulation results are shown which use modified Rodrigues parameters and sliding mode control law to achieve attitude tracking of a three-axis spacecraft with thrusters.

  • PDF

Energy and Air Quality Benefits of DCV with Wireless Sensor Network in Underground Parking Lots

  • Cho, Hong-Jae;Jeong, Jae-Weon
    • 국제초고층학회논문집
    • /
    • 제3권2호
    • /
    • pp.155-165
    • /
    • 2014
  • This study measured and compared the variation of ventilation rate and fan energy consumption according to various control strategies after installing wireless sensor-based pilot ventilation system in order to verify the applicability of demand-controlled ventilation (DCV) strategy that was efficient ventilation control strategy for underground parking lot. The underground parking lot pilot ventilation system controlled the ventilation rate by directly or indirectly tracking the traffic load in real-time after sensing data, using vehicle detection sensors and carbon monoxide (CO) and carbon dioxide ($CO_2$) sensor. The ventilation system has operated for 9 hours per a day. It responded real-time data every 10 minutes, providing ventilation rate in conformance with the input traffic load or contaminant level at that time. A ventilation rate of pilot ventilation system can be controlled at 8 levels. The reason is that a ventilation unit consists of 8 high-speed nozzle jet fans. This study proposed vehicle detection sensor based demand-controlled ventilation (VDS-DCV) strategy that would accurately trace direct traffic load and CO sensor based demand-controlled ventilation (CO-DCV) strategy that would indirectly estimate traffic load through the concentration of contaminants. In order to apply DCV strategy based on real-time traffic load, the minimum required ventilation rate per a single vehicle was applied. It was derived through the design ventilation rate and total parking capacity in the underground parking lot. This is because current ventilation standard established per unit floor area or unit volume of the space made it difficult to apply DCV strategy according to the real-time variation of traffic load. According to the results in this study, two DCV strategies in the underground parking lot are considered to be a good alternative approach that satisfies both energy saving and healthy indoor environment in comparison with the conventional control strategies.