• 제목/요약/키워드: thermal equivalent circuit

검색결과 54건 처리시간 0.022초

플라스틱 IC 패키지 접합부의 수명예측 및 품질향상에 관한 연구 (A Study on the Life Prediction and Quality Improvement of Joint in IC Package)

  • 신영의;김종민
    • Journal of Welding and Joining
    • /
    • 제17권1호
    • /
    • pp.124-132
    • /
    • 1999
  • Thermal fatigue strength of the solder joints is the most critical issue for TSOP(Thin Small Outline Package) because the leads of this package are extremely short and thermal deformation cannot be absorbed by the deflection of the lead. And the TSOP body can be subject to early fatigue failures in thermal cycle environments. This paper was discussed distribution of thermal stresses at near the joint between silicon chip and die pad and investigated their reliability of solder joints of TSOP with 42 alloy clad lead frame on printed circuit board through FEM and 3 different thermal cycling tests. It has been found that the stress concentration around the encapsulated edge structure for internal crack between the silicon chip and Cu alloy die pad. And using 42 alloy clad, The reliability of TSOP body was improved. In case of using 42 alloy clad die pad(t=0.03mm). $$\sigma$_{VMmax}$ is 69Mpa. It is showed that 15% improvement of the strength in the TSOP body in comparison with using Cu alloy die pad $($\sigma$_{VMmax}$=81MPa). In solder joint of TSOP, the maximum equivalent plastic strain and Von Mises stress concentrate on the heel of solder fillet and crack was initiated in it's region and propagated through the interface between lead and solder. Finally, the modified Manson-Coffin equation and relationship of the ratio of $N_{f}$ to nest(η) and cumulative fracture probability(f) with respect to the deviations of the 50% fracture probability life $(N_{f 50%})$ were achieved.

  • PDF

300kJ${\times}$B 모듈로 구성된 커패시터 뱅크의 특성 분석 (Characteristics of Capacitor Bank Composed of Eight Paralleled Modules)

  • 성기열;정재원;최영호;김진성;추증호;이홍식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1600-1602
    • /
    • 2001
  • A pulsed power supply of 2.4MJ capacitor bank has been developed to make investigation into electric gun technology. It is made up of eight paralleled 300kJ modules, and can supply various shape of high current pulse by changing charging voltage, inductance, capacitance, and firing time of each module. The 300kJ module has been designed and fabricated for the maximum operating voltage of 22kV, peak current of 150kA, and pulse duration of 1msec. The experiments of the modules were done, and the equivalent circuit of the module was determined. The characteristics of the module were analyzed more deeply through the circuit simulation. The experiments of the paralleled modules with inductance of 20 $\mu$H and load resistance of 100 m$\Omega$ were performed, where the modules were discharged simultaneously and/or sequentially. The results of the experiments were analyzed. The 2.4MJ capacitor bank is currently used as the pulsed power supply for the ETCG (Electro Thermal Chemical Gun) research.

  • PDF

간접냉각이 이용된 지중송전케이블의 적정냉각조건에 관한 연구 (A Study on the Optimum Cooling Condition of the Underground Power Transmission Cable Equipped with a Separate Pipe Cooling System)

  • 박만흥;최규식;서정윤;김재근;이재헌
    • 설비공학논문집
    • /
    • 제4권4호
    • /
    • pp.263-276
    • /
    • 1992
  • The transmission current in a power cable is determined under the condition of separate pipe cooling. To this end, the thermal analysis is conducted with the standard condition of separate pipe cooling system, which constitutes one of the underground power transmission system. The changes of transmission current in a power cable with respect to the variation of temperatures and flow rates of inlet cooling water as well as the cooling spans are also determined. As a consequnce, the corresponding transmission current is shown to vary within allowable limit, resulting in the linear variation of the current for most of the cable routes. The abrupt changes of current, however, for the given flow rate of inlet cooling water in some cooling span lead to the adverse effects on the smooth current transmission within the underground power transmission system. In practice, it is expected that the desinging of the separate pipe cooling system in conjunction with the evaluation of system capacity should take into account the effects of design condition on the inlet cooling flow rate.

  • PDF

박막형 열전 소자를 이용한 Chip-on-Board(COB) 냉각 장치의 설계 (A Design of Thin Film Thermoelectric Cooler for Chip-on-Board(COB) Assembly)

  • 유정호;이현주;김남재;김시호
    • 전기학회논문지
    • /
    • 제59권9호
    • /
    • pp.1615-1620
    • /
    • 2010
  • A thin film thermoelectric cooler for COB direct assembly was proposed and the COB cooler structure was modeled by electrical equivalent circuit by using SPICE model of thermoelectric devices. The embedded cooler attached between the die chip and metal plate can offer the possibility of thin film active cooling for the COB direct assembly. We proposed a driving method of TEC by using pulse width modulation technique. The optimum power to the TEC is simulated by using a SPICE model of thermoelectric device and passive components representing thermal resistance and capacitance. The measured and simulated results offer the possibility of thin film active cooling for the COB direct assembly.

PZT계 압전변압기의 공진특성과 전기적 성질 (Resonance characteristics and electrical properties of PZT-piezoelectric transformer)

  • 박순태;정수태;이종헌
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제8권1호
    • /
    • pp.27-34
    • /
    • 1995
  • The analysis of nonlinear equivalent circuit and the resonance characteristics of input current and output voltage were simulated, and their electrical properties are discussed in the transverse-type piezoelectric ceramic transformer. The nonlinear resonance characteristics of input current and output voltage showed by the thermal effect due to a higher driving current, the nonlinearity increased greatly as driving current increased. When load resistor was 100[M.ohm.], the nonlinear coefficient was -1.3. The nonlinear resonance curve of input current and output voltage for a variation of input voltage and load resistor agreed with the discussed theory. The output voltage increased nearly proportioned to input voltage when load resistors were below 50[M.ohm.], the voltage step-up ratio decreased when a load resistor was 100[M.ohm.] and their maximum value was 950.

  • PDF

Comparison between Water and N-Tetradecane as Insulation Materials through Modeling and Simulation of Heat Transfer in Packaging Box for Vaccine Shipping

  • Dao, Van-Duong;Jin, Ik-Kyu;Hur, Ho;Choi, Ho-Suk
    • 청정기술
    • /
    • 제22권1호
    • /
    • pp.45-52
    • /
    • 2016
  • This study reports on the modeling and simulation of heat transfer in packaging boxes used for vaccine shipping. Both water and n-tetradecane are used as primary insulation materials inside a multi-slab system. The one-dimensional model, which is a spherical model using a radius equivalent to the rectangular geometry of container, is applied in this study. N-tetradecane with low thermal diffusivity and proper phase transition temperature exhibits higher heat transfer resistance during both heating and cooling processes compared to water. Thus, n-tetradecane is a better candidate as an insulating material for packaging containers for vaccine shipping. Furthermore, the developed method can also become a rapid and economic tool for screening appropriate phase change materials used as insulation materials with suitable properties in logistics applications.

돌극형 동기발전기의 열전달 해석 (Analysis of temperature rise in a salient-pole synchronous generator)

  • 오석규;성기대;하현성;공관식;고요;황영문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.113-115
    • /
    • 1995
  • The calculations of the temperature rise in the armature have long been considered among some of the most important problems in the design of the rotating machine. Despite the many methods of calculation propose, very few have been used in the actual design. In most cases, These methods are inadequate for measuring a wide range of temperature distribution because of the complicated structure of the machine. In this paper, the armature is divided into seven portions, and the thermal equivalent circuit is introduced as a simulation of the armature. The test machine is 1000Kw salient-pole synchronous generator.

  • PDF

석탄 열분해 생성물이 직접탄소연료전지에서 애노드 반응에 미치는 영향에 대한 연구 (A Study on Effect of Thermal Decomposition Products of Coal on Anodic Reactions in Direct Carbon Fuel Cell)

  • 이영훈;엄성용;안성율;최경민;김덕줄
    • 한국수소및신에너지학회논문집
    • /
    • 제24권5호
    • /
    • pp.413-420
    • /
    • 2013
  • Effect of inherent volatile matters in fuels on electrochemical reactions of anode was investigated for a single direct carbon fuel cell (DCFC). Raw coals used as power source in the DCFC release light gases into the atmosphere under the operating temperature of DCFC ($700^{\circ}C$) by thermal decomposition and only char remained. These exhausted gases change the gas composition around anode and affect the electrochemical oxidation reaction of system. To investigate the effect of produced gases, comparative study was conducted between Indonesian sub-bituminous coal and its char obtained through thermal treatment, carbonizing. Maximum power density of raw coal ($52mW/cm^2$) was appeared higher than that of char ($37mW/cm^2$) because the gases produced from the raw coal during thermal decomposition gave additional positive results to electrochemical reaction of the system. The produced gases from coals were analyzed using TGA and FT-IR. The influence of volatile matters on anodic electrolyteelectrode interface was observed by the equivalent circuit induced from fitting of impedance spectroscopy data.

커패시터 멀티플라이어를 갖는 CCM/DCM 이중모드 DC-DC 벅 컨버터의 설계 (Design of a CCM/DCM dual mode DC-DC Buck Converter with Capacitor Multiplier)

  • 최진웅;송한정
    • 한국산학기술학회논문지
    • /
    • 제17권9호
    • /
    • pp.21-26
    • /
    • 2016
  • 본 논문에서는 휴대 전자기기의 내부 전원단을 위한, CCM/DCM 기능의 이중모드 감압형 DC-DC 벅 컨버터를 제안한다. 제안하는 변환기는 1 MHz의 주파수에서 동작하며, 파워단과 제어블럭으로 이루어진다. 파워단은 Power MOS 트랜지스터, 인덕터, 커패시터, 제어 루프용 피드백 저항으로 구성된다. 제어부는 펄스폭 변조기 (PWM), 오차증폭기, 램프 파 발생기, 오실레이터 등으로 이루진다. 또한 본 논문에서 보상단의 큰 외부 커패시터는, 집적회로의 면적축소를 위하여 CMOS 회로로 구성되는 멀티플라이어 등가 커패시터로 대체하였다. 또한,. 본 논문에서, 보상단의 외부 커패시터는 집적회로의 면적을 줄이기 위하여 곱셈기 기반 CMOS 등가회로로 대체하였다. 또한 제안하는 회로는 칩을 보호하기 위하여 출력 과전압, 입력부족 차단 보호회로 및 과열 차단 보호회로를 내장하였다. 제안하는 회로는 $0.18{\mu}m$ CMOS 공정을 사용하여, 케이던스의 스펙트라 회로설계 프로그램을 이용하여 설계 및 검증을 하였다. SPICE 모의 실험 결과, 설계된 이중모드 DC-DC 벅 변환기는 94.8 %의 피크효율, 3.29 mV의 리플전압, 2.7 ~ 3.3 V의 전압 조건에서 1.8 V의 출력전압을 보였다.

120 kW급 태양광 발전시스템 설치 및 실 계통연계 운전 결과 평가 (Test Results Grid Connection of 120 kW Power Generation System)

  • 황정희;안교상;임희천;김수창;김신섭
    • 한국수소및신에너지학회논문집
    • /
    • 제17권3호
    • /
    • pp.338-346
    • /
    • 2006
  • In this paper, the test results of medium-size(120 kW class) PV system which was installed in the Taeahn thermal power station of Korea Western Power Co., Ltd., were summarized for developing the practical technology to applicate high voltage grid connection PV system. The 120 kW photovoltaic system which was consisted of 1,300 modules, PCS, and 150 kVA transformer station has been operated since Aug. 05, 2005. For verifying the modeling results of PV system, the operation data was compared with modeling results which was executed commercial PSCAD/EMTD and Psim tools. An equivalent circuit model of a solar cell has been also used for solar array modeling. A series of parameters required for array modeling have been estimated from general specification data of a solar module. A PWM voltage source inverter(VIS) and its current control scheme have been analyzed by using P&O (perturbation and Observation) MPPT algorithms technique.