• Title/Summary/Keyword: test circuit

Search Result 1,837, Processing Time 0.033 seconds

A Study on the Expandable Bobbin Type Multiple Integrated Coupled-Inductor Applied 4-Pralleled Switching Rectifier (보빈 적층 방식의 다중 공유결합 인덕터를 이용한 4병렬 스위칭 정류기에 관한 연구)

  • Yoo, Jeong Sang;Ahn, Tae Young
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.4
    • /
    • pp.18-24
    • /
    • 2019
  • In this paper, expandable bobbin type multiple integrated coupled-inductor applied 4-paralled switching rectifier was proposed. To design the proposed inductor easily, inductance designing formula was derived through magnetic circuit analysis of the 4-paralleled integrated coupled-inductor. Furthermore, to verify practicality of the proposed inductor, it was applied in 600W class 4-paralleled interleaved switching rectifier, and the steady-state characteristics of the proposed inductor and discrete inductors were compared. Consequently, it was showed that the proposed inductor can replace the conventional discrete inductors with alternative electrical characteristic standard, hence miniaturization of the SMPS can be achieved. From the test result, test circuit with the proposed inductor showed maximum 97.1% of power conversion efficiency and under 18W of power loss where the circuit with discrete inductors showed 96.7% and 20W respectively.

Effects of Bonding Conditions on Mechanical Strength of Sn-58Bi Lead-Free Solder Joint using Thermo-compression Bonding Method (열압착 접합 조건에 따른 경·연성 인쇄회로기판 간 Sn-58Bi 무연솔더 접합부의 기계적 특성)

  • Choi, Ji-Na;Ko, Min-Kwan;Lee, Sang-Min;Jung, Seung-Boo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.20 no.2
    • /
    • pp.17-22
    • /
    • 2013
  • We investigated the optimum bonding conditions for thermo-compression bonding of electrodes between flexible printed circuit board(FPCB) and rigid printed circuit board(RPCB) with Sn-58Bi solder as interlayer. In order to figure out the optimum bonding conditions, peel test of FPCB/RPCB joint was conducted. The peel strength was affected by the bonding conditions, such as temperature and time. The fracture energies were calculated through F-x (Force-displacement) curve during peel test and the relationships between bonding conditions and fracture behaviors were investigated. The optimum condition for the thermo-compression bonding with Sn-58Bi solder was found to be temperature of $195^{\circ}C$ and time of 7 s.

A New Logic Transformation Method for Both Low Power and High Testability (저 전력소모와 높은 테스트용이성을 위한 새로운 논리 변환 방법)

  • 손윤식;정정화
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.9
    • /
    • pp.692-701
    • /
    • 2003
  • In this paper, a new logic transformation method to consider both low power consumption and high testability is proposed. We search the CFF(Compact Fanout Free) that has low probability of being observable at the primary outputs. Under the condition that the CFF is unobservable at all primary outputs, the switching operations in it can be removed by adding redundant connections into it. The testability of the transformed circuit generally tends to reduce. In our method, however, the inserted redundant connections operate as test points in the test mode and can improve not only the controllability but also the observability of the CFF. The transformed circuit consumes less power in the normal mode and also has higher testability in the test mode. To show the efficiency of the proposed logic transformation method, we perform some experiments on the MCNC benchmark test circuits. The results show that the power consumption of the transformed circuit is reduced by 13% maximally and the fault coverage of the transformed circuit is increased.

A Result Analysis on Field Test for Localization Development of Axle Counter System (Axle Counter System 국산화 개발을 위한 현장시험 결과분석)

  • Ko, Joon-Young;Park, Jae-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.9
    • /
    • pp.6214-6220
    • /
    • 2015
  • A track circuit has used stably more than 100 years for detecting train position, but solution of track circuit sort circuit incapacity due to a rust is necessary for side line in station yard, coast line and level crossing for conventional line in rural line. Domestically, Axle Counter System(ACS) has partially used for Hot Box System for high speed line and turnout for CBTC system. In contrast, most of countries has used ACS not only trunk line but also rural line and its application has increased for metro, electric car and industrial railway. In this paper, we has verified the operating status of ACS which installed with existing track circuit through log analsis to implement pilot application in mail track and turnout in station yard. And interface test with interlocking system has conducted at Obong shunting yard, as well as Cheongju station and has analyzed test result. Based on a test result, we made fail safe design, manufacturing skill and established system requirement specification for the smooth operation and maintenance.

A Study on the Fault Detection of ASIC using Dynamic Pattern Method (Dynamic Pattern 기법을 이용한 주문형 반도체 결함 검출에 관한 연구)

  • Shim, Woo-Che;Jung, Hae-Sung;Kang, Chang-Hun;Jie, Min-Seok;Hong, Gyo-Young;Ahn, Dong-Man;Hong, Seung-Beom
    • Journal of Advanced Navigation Technology
    • /
    • v.17 no.5
    • /
    • pp.560-567
    • /
    • 2013
  • In this paper, it is proposed the fault detection method of the ASIC, without the Test Requirement Document(TRD), extracting internal logic circuit and analyzed the function of the ASIC using the multipurpose development program and simulation. If there don't have the TRD, it is impossible to analyze the operation of the circuit and find out the fault detection in any chip. Therefore, we make the TRD based on the analyzed logic data of the ASIC, and diagnose of the ASIC circuit at the gate level through the signal control of I/O pins using the Dynamic Pattern signal. According to the experimental results of the proposed method, we is confirmed the good performance of the fault detection capabilities which applied to the non-memory circuit.

Realization of 10/350 Peaking Circuit for appling crowbar switch (Crowbar 스위치용 10/350 피킹(peaking) 회로 구현)

  • Cho, Sung-Chul;Lee, Tae-Hyung;Eom, Ju-Hong;Yoo, Yang-Woo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.327-329
    • /
    • 2009
  • A first short stoke current which has a 10/350 ${\mu}s$ waveform is able to be generated by using the crowbar switch in R-L-C circuit. In this paper, a peaking circuit has been applied to make crowbar switch. Operate effective for generating 10/350 ${\mu}s$ waveform. According to simulation with PSpice, we have found that some value of inductance were more effective to trigger a crowbar switch. As a result of experimental test using crowbar switch with peaking circuit, the success rate of triggering crowbar switch is higher than the normal crowbar switch without peaking circuit.

  • PDF

Limiting method of short-circuit making current by controlling the time constant of dc component (단락시험 회로의 시정수 조정에 의한 투입전류 제한법)

  • Park, Seung-Jae;Ryou, Hyeong-Kee;Kang, Young-Sik;Koh, Heui-Seog
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.466-468
    • /
    • 2002
  • In order to newly define and specify the performance and the testing method of the high-voltage circuit breaker, IEC 62271-100 was published in May, 2001 and took place of IEC 60056 which had been used since 1987. This new standard intensifies the requirement and the test method of the circuit breaker and also domestic manufacturer makes progress the new product development. And, KERI also goes on the build-up project of short-circuit testing facilities for fulfilling the testing method requirements in new IEC 62271-100. This paper introduce the limiting method of short-circuit making current by controlling the time constant of dc component.

  • PDF

Development of Bridge Circuit for Measuring Pressure Wave in Inkjet Head (잉크젯 압력파 측정을 위한 브리지 회로 개발)

  • Kwon, Kye-Si;Myung, Jae-Hwan;Joo, Young-Cheol;Lee, Sang-Wook;Kim, Kug-Weon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.4
    • /
    • pp.342-347
    • /
    • 2008
  • Bridge circuit was developed such that the pressure wave in the inkjet can be measured. In order to test the circuit, the microfab single ejector was used. For the experiment, the head was filled with nano silver ink (20wt%). In order to generate waveform voltage for jetting signal, the Agilent 33120 was used in order to generate arbitrary waveform. For the driver, PZD 350 from TREK was used in order to amplify the waveform. Experimental results show that the designed circuit can effectively detect the pressure wave in the inkjet head.

Circuit Design for Compesation of a Dry Fingerprint Image Quality on Charge Sharing Scheme (전하분할 방식의 건조 지문이미지 보상회로 설계)

  • Jung, Seung-Min;Yeo, Hyeop-Goo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.795-797
    • /
    • 2013
  • This paper describes a charge sharing capacitive-sensing circuit technique that improves the quality of images captured with fingerprint sensor LSIs. When the finger is dry, the electrical resistance of a finger surface is high. It leads to poor image quality. To capture clear images even when the finger is dry, the modified capacitive detection circuit improves the image quality using an enhancement plate at the finger surface and a voltage control circuit. The test circuit is analyzed on $0.35{\mu}m$ CMOS process.

  • PDF

Simplified Synthetic Testing Facility with Modified TRV Circuit

  • Chong, Jin-Kyo;Lee, Kyung Seob;Lee, Chang-Hoon;Kim, Gyu-Tak
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.881-885
    • /
    • 2018
  • In order to develop a gas circuit breaker (GCB), the breaking performance of the short line fault (SLF) should be prioritized over that of the breaker terminal fault (BTF). In brief, it is necessary to evaluate the thermal characteristics of the insulating gas that is filled in a GCB. In the process of developing a GCB, many companies use the simplified synthetic testing facility (SSTF).In order to evaluate the SLF breaking performance of a GCB with a long minimum arcing time, a modifications to the conventional SSTF was proposed. In this study, we developed the SSTF with a modified transient recovery voltage circuit. The performance of the newly developed SSTF was verified by an $L_{90}$ breaking performance test on a rating combination of 170 kV, 50 kA, and 60 Hz.