• 제목/요약/키워드: temperature-sensitive

검색결과 1,632건 처리시간 0.031초

A PDMS-Coated Optical Fiber Bragg Grating Sensor for Enhancing Temperature Sensitivity

  • Park, Chang-Sub;Joo, Kyung-Il;Kang, Shin-Won;Kim, Hak-Rin
    • Journal of the Optical Society of Korea
    • /
    • 제15권4호
    • /
    • pp.329-334
    • /
    • 2011
  • We proposed a poly-dimethylsiloxane (PDMS)-coated fiber Bragg grating (FBG) temperature sensor for enhancing temperature sensitivity. By embedding the bare FBG in a temperature-sensitive elastomeric polymer, the temperature sensitivity of the proposed structure could be effectively improved by 4.2 times higher than those of the conventional bare-type FBG sensors due to the high thermal expansion coefficient of the PDMS. We analyzed the temperature-sensitivity enhancement effect with the increased Bragg wavelength shift in our structure and dependence on the temperature sensitivity with respect to the cross-section area of the PDMS.

150℃이하 저온에서의 미세 접합 기술 (Low Temperature bonding Technology for Electronic Packaging)

  • 김선철;김영호
    • 마이크로전자및패키징학회지
    • /
    • 제19권1호
    • /
    • pp.17-24
    • /
    • 2012
  • Recently, flip chip interconnection has been increasingly used in microelectronic assemblies. The common Flip chip interconnection is formed by reflow of the solder bumps. Lead-Tin solders and Tin-based solders are most widely used for the solder bump materials. However, the flip chip interconnection using these solder materials cannot be applied to temperature-sensitive components since solder reflow is performed at relatively high temperature. Therefore the development of low temperature bonding technologies is required in these applications. A few bonding techniques at low temperature of $150^{\circ}C$ or below have been reported. They include the reflow soldering using low melting point solder bumps, the transient liquid phase bonding by inter-diffusion between two solders, and the bonding using low temperature curable adhesive. This paper reviews various low temperature bonding methods.

기후변화에 따른 벼 적정 등숙기간의 변동과 대책 (Climate Change Impacts on Optimum Ripening Periods of Rice Plant and Its Counter-Measure in Rice Cultivation)

  • 윤성호;이정택
    • 한국작물학회:학술대회논문집
    • /
    • 한국작물학회 2000년도 추계 학술대회지
    • /
    • pp.28-45
    • /
    • 2000
  • It was unusual crop weather for 1998 and 1999 compared with normal in Korea. The consecutive days of the optimum ripening period for rice plant that had daily mean temperature 21-23C for 40 days after heading, increased with long anomalies in 1998-99. The air temperature during ripening period was much higher than the optimum temperature and lower sunshine hour than normal in the local adaptability tests of newly developed rice lines during those years. In response of rice cultivation to warming and cloudy weather during crop season, the yield shall be decreased. Most scientists agree that the rate of heating is accelerating and temperature change could become increasingly disruptive. Weather patterns should also become more erratic. Agrometeorologists could be analyzed yearly variations of temperature, sunshine hour and rainfall pattern focused on transient agroclimate change for last a decade. Rice agronomists could be established taking advantage of real time agricultural meteorology information system for fertilization, irrigation, pest control and harvest. Also they could be analyzed the characteristics of flowering response of the recommended and newly bred rice cultivars for suitable cropping plan such as cultural patterns and sowing or transplanting date. Rice breeders should be deeply considered introducing the characteristics of basic vegetative type of flowering response like Tonsil rices as prospective rice cultivars corresponding to global warming because of the rices needed higher temperature at ripening stage than Japonica rices, photoperiod sensitive and thermo-sensitive ecotypes

  • PDF

Ceriodaphnia dubia의 먹이섭생 기작과 온도조절에 근거한 급성독성조사법의 비교 (Comparison of Short-Term Toxicity Tests Based on Feeding Behavior and Temperature Control by Ceriodaphnia dubia)

  • 박종호;이상일;조영옥
    • 한국물환경학회지
    • /
    • 제20권1호
    • /
    • pp.48-54
    • /
    • 2004
  • Two methods, a Ceriodaphnia algal uptake suppression test (CAUST) and a new toxicity test based on temperature control (TTBTC) which are based on feeding behaviour and temperature control, respectively, were developed and compared for the adoption as the better methodology for short-term toxicity screening. As previously published by Lee et aI., (1997), the CAUST method is based on the feeding behaviour of C. dubia and requires as little as 1 hour of contact time between C. dubia neonates and toxicant. However, even though CAUST requires only 1 hour of contact time, this method still take many hours for the preparation and measurement. Before the test starts, neonate digestive tracts were cleared by feeding yeast to the daphnids, Neonates were then exposed to toxicant, followed by addition of Scenedesmus subspiatus into the bioassay vessels. Daphnids were examined under the bright-field microscope with the presence of algae (indicated by a green colored digestive tract) or the absence of algae. Uptake indicated no toxic effect, whereas, absence of uptake indicated toxic inhibition. Unlike CAUST, the newly developed method (TTBTC) is based on just temperature control for the toxicity test of C. dubia. Initially, neonates are exposed to toxicants while the temperature of water bath containing media increased to $35.5^{\circ}C$. After 1.25 hour of contact time, the number of the daphnids, either live (no toxic effect) or dead (toxic effect), is counted without the aid of any instrument. In both methods, median effective concentrations ($EC_{50}$ values) were computed based on the results over a range of dosed toxicant concentrations. It showed that TTBTC was as sensitive as the standard 48-hour acute bioassay and CAUST. TTBTC and CAUST were much more sensitive than the I-hour I.Q. test and 30-minute Microtox. This study indicates that TTBTC is an easier and more rapid toxicity test than the standard 48-hour acute bioassay and even CAUST.

에어컨 온도상승에 따른 온열쾌적성 변화에 관한 연구 (Research on Thermal Comfort by Increasing Air Conditioner Temperature)

  • 김형철;금종수;김동규;정용현
    • 수산해양교육연구
    • /
    • 제18권2호
    • /
    • pp.77-84
    • /
    • 2006
  • This research evaluates thermal comfort by comparing the case of maintain cooing temperature of room with the case of raising it at the point of time that human body begins to adapt. An experiment uses constant temperature & humidity chamber 2 places. Pretesting room make up summer season environment, the testing room control by air-conditioner. In condition that maintain temperature of $33^{\circ}C$. The subjects stay in the pretesting room during the 30 minute for the heat storage amount of the normal summertime. The subjects stay in the testing room under each case (case 1: maintaining $24^{\circ}C$, case 2: maintaining $26^{\circ}C$, case 3: up $1^{\circ}C$ after maintaining $24^{\circ}C$ during 30 minute, case 4: up $1^{\circ}C$ after maintaining $26^{\circ}C$ during 40 minute). 1. Result of comparison of case 1 and case 2 appears that thermal sensitive vote examine from slight cool to cool and thermal comfort examine slight comfort by temperature rise at human body adaptation point of time.2. Test of case 3 and case 4 appear similar value at thermal sensitive vote and thermal comfort.3. Through the case 2 and case 4, continuous thermal comfort maintain at $24^{\circ}C$, if raise $26^{\circ}C$, same thermal comfort maintain after a human body adaptation temperature rising effect bring energy saving.

폴리머 마이크로링 공진기를 이용한 고감도 집적광학형 온도센서 (Highly Sensitive Integrated Photonic Temperature Sensor Exploiting a Polymeric Microring Resonator)

  • 이학순;김건덕;이상신
    • 한국광학회지
    • /
    • 제19권3호
    • /
    • pp.224-228
    • /
    • 2008
  • 본 논문에서는 폴리머 마이크로링 공진기 기반의 고감도 집적광학형 온도센서를 제안하고 구현하였다. 이 센서는 열광학효과로 인한 공진기 소자의 공진파장의 이동으로부터 주변 온도 변화를 측정한다. 열팽창계수가 작은 실리콘 기판 위에 열광학계수가 큰 폴리머를 도입하여 공진기 센서를 제작함으로써 센서의 감도를 향상시켰다. 상온 부근 $20^{\circ}C{\sim}30^{\circ}C$의 범위에서 얻어진 온도센서의 감도는 약 -165 ${\pm}/^{\circ}C$였고, 온도분해능은 $0.1^{\circ}C$이하였다. 그리고 제작된 온도센서의 동작 특성은 표면에 놓여진 분석대상물의 굴절률 변화에 거의 영향을 받지 않음을 확인하였다. 따라서 제작된 센서는 다른 광센서에 집적되어 주변 온도 변화로 인하여 유발되는 오차를 효과적으로 보정할 수 있을 것으로 기대된다.

Wafer-Level Packaged MEMS Resonators with a Highly Vacuum-Sensitive Quality Factor

  • Kang, Seok Jin;Moon, Young Soon;Son, Won Ho;Choi, Sie Young
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제14권5호
    • /
    • pp.632-639
    • /
    • 2014
  • Mechanical stress and the vacuum level are the two main factors dominating the quality factor of a resonator operated in the vacuum range 1 mTorr to 10 Torr. This means that if the quality factor of a resonator is very insensitive to the mechanical stress in the vacuum range, it is sensitive to mainly the ambient vacuum level. In this paper, a wafer-level packaged MEMS resonator with a highly vacuum-sensitive quality factor is presented. The proposed device is characterized by a package with out-of-plane symmetry and a suspending structure with only a single anchor. Out-of-plane symmetry helps prevent deformation of the packaged device due to thermal mismatch, and a single-clamped structure facilitates constraint-free displacement. As a result, the proposed device is very insensitive to mechanical stress and is sensitive to mainly the ambient vacuum level. The average quality factors of the devices packaged under pressures of 50, 100, and 200 mTorr were 4987, 3415, and 2127, respectively. The results demonstrated the high controllability of the quality factor by vacuum adjustment. The mechanical robustness of the quality factor was confirmed by comparing the quality factors before and after high-temperature storage. Furthermore, through more than 50 days of monitoring, the stability of the quality factor was also certified.

엔지니어링 플라스틱 재료의 재활용 혼합비가 성형품 수축에 미치는 영향 (The Effect on Mixed Ratio of Recycled Engineering plastic Resin on the Shrinkage in Molded Parts)

    • 자원리싸이클링
    • /
    • 제13권3호
    • /
    • pp.43-49
    • /
    • 2004
  • 플라스틱 재료는 재생이 가능한 열가소성 플라스틱과 재생이 거의 불가능한 열경화성 플라스틱으로 분류 할 수 있고, 본 연구에서는 재생이 가능한 열가소성 플라스틱 중 산업 및 생활 전반에 널리 사용되고 있는 PP. PA6, PC 및 PBT 재료의 재생 방안에 대한 기초 연구로서 재생 재료의 혼합비가 증가함에 따라 치수 정밀도에 미치는 영향을 고찰하였다.

PdHx 박막의 두께 변화에 의한 전기비저항의 온도 의존성 변화 (Temperature Dependence Change of Electrical Resistivity on PdHx Films due to Film Thickness Change)

  • 조영신
    • 한국수소및신에너지학회논문집
    • /
    • 제6권1호
    • /
    • pp.17-22
    • /
    • 1995
  • Thermally evaporated Pd films on substrate were hydrogenated upto 1 bar of hydrogen gas at room temperature. Temperature dependence hange of electrical resistivity on Pd films is examined in the thickness range between $60{\AA}$ and $990{\AA}$. Resistivity of Pd is fitted well with Bloch-$Gr{\ddot{u}}neisen$ formula. Debye temperatures of Pd films are about 254 K, which are 20 K lower than that of bulk Pd. Debye temperature is not sensitive to film thickness change. Temperature of substrate during evaporation changes temperature dependence of resistivity of films much. Optical phonon contribution increases with decreasing temperature of PdHx.

  • PDF

Development of an Infrared Two-color Probe for Particle Cloud Temperature Measurement

  • Alshaikh Mohammed, Mohammed Ali;Kim, Ki Seong
    • 한국분무공학회지
    • /
    • 제20권4호
    • /
    • pp.230-235
    • /
    • 2015
  • The demands for reliable particle cloud temperature measurement exist in many process industries and scientific researches. Particle cloud temperature measurements depend on radiation thermometry at two or more color bands. In this study, we developed a sensitive, fast response and compact online infrared two-color probe to measure the temperature of a particle cloud in a phase of two field flow (solid-gas). The probe employs a detector contained two InGaAs photodiodes with different spectral responses in the same optical path, which allowed a compact probe design. The probe was designed to suit temperature measurements in harsh environments with the advantage of durability. The developed two-color probe is capable of detecting particle cloud temperature as low as $300^{\circ}C$, under dynamic conditions.