Browse > Article

Research on Thermal Comfort by Increasing Air Conditioner Temperature  

Kim, Hyung-Chul (Pukyong National University)
Kum, Jong-Soo (Pukyong National University)
KIM, Dong-Gyu (Pukyong National University)
CHUNG, Yong-Hyun (Pukyong National University)
Publication Information
Journal of Fisheries and Marine Sciences Education / v.18, no.2, 2006 , pp. 77-84 More about this Journal
Abstract
This research evaluates thermal comfort by comparing the case of maintain cooing temperature of room with the case of raising it at the point of time that human body begins to adapt. An experiment uses constant temperature & humidity chamber 2 places. Pretesting room make up summer season environment, the testing room control by air-conditioner. In condition that maintain temperature of $33^{\circ}C$. The subjects stay in the pretesting room during the 30 minute for the heat storage amount of the normal summertime. The subjects stay in the testing room under each case (case 1: maintaining $24^{\circ}C$, case 2: maintaining $26^{\circ}C$, case 3: up $1^{\circ}C$ after maintaining $24^{\circ}C$ during 30 minute, case 4: up $1^{\circ}C$ after maintaining $26^{\circ}C$ during 40 minute). 1. Result of comparison of case 1 and case 2 appears that thermal sensitive vote examine from slight cool to cool and thermal comfort examine slight comfort by temperature rise at human body adaptation point of time.2. Test of case 3 and case 4 appear similar value at thermal sensitive vote and thermal comfort.3. Through the case 2 and case 4, continuous thermal comfort maintain at $24^{\circ}C$, if raise $26^{\circ}C$, same thermal comfort maintain after a human body adaptation temperature rising effect bring energy saving.
Keywords
Thermal Comfort; TSV; CSV; MST; LST;
Citations & Related Records
연도 인용수 순위
  • Reference
1 금종수, '온열쾌적감 측정기술 및 DB개발', 제9회 G7 감성공학 감성요소 기술개발 및 DB구축 workshop 자료집, pp.78-94. 1997
2 김형철, 금종수, 신병환, 정용현, '에어콘 온도변동에 따른 온여쾌적감 평가 및 생리신호 변화에 관한 연구', 수산해양교육연구 18(1), pp.11-18, 2006
3 Fanger.P.O., 'Thermal Comfort', McGraw- Hill Book Company, 1972
4 김형철, '온열쾌적성 도달을 위한 냉방기류 및 온도변동 조건에 관한 연구', 박사학위논문, 부경대학교, pp.78-101, 2006
5 花田嘉代子,三平和雄. '男性用下着類熱抵抗の 計測に關する硏究',繊維製品消費科學會誌, pp.31-37, 1983
6 Hardy, J.D., E.F. Du Bois,'The technic of measuring radiation and convection, The journal of nutrition, Vol.15, pp.461-475, 1968
7 Tanabe, 'Thermal Comfort Requirements in Japan', Ph.D. Waseda University, 1988
8 Fukai, K., S. Gotoh, J. Saito, H. Ito, S. Akui, 'Experimental Study on Correlation between Standard New Effective Temperature(SET*) and Japanese Thermal Sensation Part2-Comparison of Thermal Sensation in Winter and Summer Seasons', The Society of Heating, Air-Conditioning and Sanitary Engineers of Japan, No.51, pp.139-147, 1993
9 Horikoshi,T.Y,.Kobayashi,T. Tsuchikawa,' Indexes of Combined and Independent of Thermal Environmental Variables upon the Human Body', ASHRAE Transaction Research, Vol.97, pp.228-238, 1991
10 Gagge,A.P., A.P.Fobelets, L.G.Berglund, 'A Standard Predictive Index of Human Response to the Thermal Environment', ASHRAE Transaction, Vol.1992, Part2, pp.709-731, 1986
11 Gagge, A. P.,Nishi, Y. , and Nevins R.G. 'The Role of Clothing in Meeting FEA Energy Conservation Guidelines' ASHRAE Transactions, No.2417, pp.234-247, 1976
12 Fanger,P.O., 'Thermal Comfort Analysis and Application in Environmental Engineering', Danish Technical Press, 1970