• Title/Summary/Keyword: system gamma

Search Result 1,592, Processing Time 0.032 seconds

Development of Automatic Gamma Optimization System for Mobile TFT-LCD (DSP를 이용한 모바일 TFT-LCD의 자동 감마 최적화 시스템 개발)

  • Cho, Nae-Soo;Ryu, Jee-Youl;Park, Chul-Woo;Kwon, Woo-Hyen
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.3
    • /
    • pp.323-329
    • /
    • 2009
  • This paper presents an automatic LCD gamma control system using gamma curve optimization. It controls automatically gamma adjustment registers in mobile LCD driver IC to reduce gamma correction error and adjusting time. The proposed gamma system contains Module-Under-Test (MUT, LCD module), PC installed with program, multimedia display tester for measuring luminance, and control board for interface between PC and LCD module. Proposed algorithm and program are applicable for most of the LCD modules. It is realized to calibrate gamma values of 1.8, 2.0, 2.2 and 3.0. The control board is designed with DSP and FPGA, and it supports various interfaces such as RGB and CPU. Developed automatic gamma control system showed significantly reduced gamma adjusting time of 240 sec. and much less average gamma error of 11% than 42h and 27% with conventional manual method. We believe that the proposed system is very useful to provide high-quality LCD and to improve production process.

Development of Neutron Induced Prompt γ-ray Spectroscopy System Using 252Cf (252Cf 선원을 이용한 즉발감마선 계측시스템 구성)

  • Park, Yong-Joon;Song, Byung-Chul;Jee, Kwang-Yong
    • Analytical Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.12-24
    • /
    • 2003
  • For the design and set-up of neutron induced prompt ${\gamma}$-ray spectroscopy system using $^{252}Cf$ neutron source, the effects of shielding and moderator materials have been examined. The $^{252}Cf$ source being used for TLD badge calibration in Korea Atomic Energy Research Institute was utilized for this preliminary experiment. The ${\gamma}$-ray background and prompt ${\gamma}$-ray spectrum of the sample containing Cl were measured using HPGe (GMX 60% relative efficiency) located at the inside of the system connected to notebook PC at the outside of the system (about 20 meter distance). The background activities of neutron and ${\gamma}$-rays were measured with neutron survey meter as well as ${\gamma}$-ray survey meters, respectively and the system was designed to minimize the activities. Prompt ${\gamma}$-ray spectrum was measured using ${\gamma}$-${\gamma}$ coincident system for reduce the background and the continuum spectrum. The optimum system was designed and set up using the experimental data obtained.

Development of Gamma Camera System for Small Animal Imaging and Environmental Radiation Detection (소동물 영상화 및 환경 방사선 검출을 위한 감마카메라 개발)

  • Baek, Cheol-Ha
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.2
    • /
    • pp.475-481
    • /
    • 2014
  • The aim of this work was to develop the gamma camera system for small animal gamma imaging and environmental radiation monitoring imaging using a parallel hole collimator and pinhole collimator. The small gamma camera system consists of a CsI(Tl) scintillation crystal with 6 mm in thickness and $50{\times}50mm$ in area coupled with a Hamamatsu H8500C PSPMT, are resistive charge divider, pre-amplifiers, charge amplifiers, nuclear instrument modules (NIMs), an analog to digital converter and a computer for control and display. We have developed a radiation monitoring system composed of a combined pinhole gamma camera and a charge-coupled devices (CCD) camera. The results demonstrated that the parallel hole collimator and pinhole collimator gamma camera designed in this study could be utilized to perform small animal imaging and environmental radiation monitoring system. Consequently in this paper, we proved that our gamma detector system is reliable for a gamma camera which can be used as small animal imaging and environmental radiation monitoring system.

Validation of Gamma Knife Perfexion Dose Profile Distribution by a Modified Variable Ellipsoid Modeling Technique

  • Hur, Beong Ik;Jin, Seong Jin;Kim, Gyeong Rip;Kwak, Jong Hyeok;Kim, Young Ha;Lee, Sang Weon;Sung, Soon Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.1
    • /
    • pp.13-22
    • /
    • 2021
  • Objective : High precision and accuracy are expected in gamma knife radiosurgery treatment. Because of the requirement of clinically applying complex radiation and dose gradients together with a rapid radiation decline, a dedicated quality assurance program is required to maintain the radiation dosimetry and geometric accuracy and to reduce all associated risk factors. This study investigates the validity of Leksell Gamma plan (LGP)10.1.1 system of 5th generation Gamma Knife Perfexion as modified variable ellipsoid modeling technique (VEMT) method. Methods : To verify LGP10.1.1 system, we compare the treatment plan program system of the Gamma Knife Perfexion, that is, the LGP, with the calculated value of the proposed modified VEMT program. To verify a modified VEMT method, we compare the distributions of the dose of Gamma Knife Perfexion measured by Gafchromic EBT3 and EBT-XD films. For verification, the center of an 80 mm radius solid water phantom is placed in the center of all sectors positioned at 16 mm, 4 mm and 8 mm; that is, the dose distribution is similar to the method used in the x, y, and z directions by the VEMT. The dose distribution in the axial direction is compared and analyzed based on Full-Width-of-Half-Maximum (FWHM) evaluation. Results : The dose profile distribution was evaluated by FWHM, and it showed an average difference of 0.104 mm for the LGP value and 0.130 mm for the EBT-XD film. Conclusion : The modified VEMT yielded consistent results in the two processes. The use of the modified VEMT as a verification tool can enable the system to stably test and operate the Gamma Knife Perfexion treatment planning system.

The Role of the Gamma System in Movement and Posture (${\gamma}$계(系)의 자세(姿勢) 및 운동(運動)에 대(對)한 조절기능(調節機能)에 관(關)하여 - Stretch reflex feed back system에 있어서 ${\gamma}$계(系)의 작용(作用)을 중심(中心)으로 -)

  • Kim, Jeh-Hyub
    • The Korean Journal of Physiology
    • /
    • v.4 no.2
    • /
    • pp.19-24
    • /
    • 1970
  • Since the discovery of the muscle spindle by Hassall (1831), an intensive studies of its anatomical and physiological characteristics had been undertaken. Recent morphological studies of Boyd (1962) demonstrated that the muscle spindles have two different intrafusal muscle fibers, nuclear bag and nuclear chain fiber, and these intrafusal fibers are under independent motor innervation by ${\gamma}_1$ and ${\gamma}_2$ motor neurone. Neurophysiological studies of Hunt and Kuffler (1951) showed regulatory effect of ${\gamma}$ motor neurone upon the excitability of the spindle afferents. Harvey and Mathews (1961) observed the dynamic and static characteristics of the two different spindle afferents, the primary and secondary ending. Furthermore, Mathews (1962) postulated the functional existance of two kind of ${\gamma}$ motor neurones, namely, the dynamic and static fusimotor fiber. Recent report of Kim and Partridge(1969) pointed out that the descending vestibular signals had increased the slope of the length-tension relationship in stretch reflex; Kim (1967) demonstrated that the descending vestibular impulses act upon the stretch reflex loop through the ${\gamma}$ motor pathway. These experimental evidences from the morphological and neurophysiological studies on the muscle spindles support the concept that the stretch reflex action of the skeletal muscle operates as a negative feedback control system. The author had discussed the way by which the f system participates in the control of stretch relfex feed back system. that was taken for a prototype of posture and movement.

  • PDF

Fast non-local means noise reduction algorithm with acceleration function for improvement of image quality in gamma camera system: A phantom study

  • Park, Chan Rok;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • v.51 no.3
    • /
    • pp.719-722
    • /
    • 2019
  • Gamma-ray images generally suffer from a lot of noise because of low photon detection in the gamma camera system. The purpose of this study is to improve the image quality in gamma-ray images using a gamma camera system with a fast nonlocal means (FNLM) noise reduction algorithm with an acceleration function. The designed FNLM algorithm is based on local region considerations, including the Euclidean distance in the gamma-ray image and use of the encoded information. To evaluate the noise characteristics, the normalized noise power spectrum (NNPS), contrast-to-noise ratio (CNR), and coefficient of variation (COV) were used. According to the NNPS result, the lowest values can be obtained using the FNLM noise reduction algorithm. In addition, when the conventional methods and the FNLM noise reduction algorithm were compared, the average CNR and COV using the proposed algorithm were approximately 2.23 and 7.95 times better than those of the noisy image, respectively. In particular, the image-processing time of the FNLM noise reduction algorithm can achieve the fastest time compared with conventional noise reduction methods. The results of the image qualities related to noise characteristics demonstrated the superiority of the proposed FNLM noise reduction algorithm in a gamma camera system.

Antioxidant Activity of γ-Oryzanol and Synthetic Phenolic Compounds in an Oil/Water (O/W) Emulsion System

  • Kim, Joo-Shin
    • Preventive Nutrition and Food Science
    • /
    • v.12 no.3
    • /
    • pp.173-176
    • /
    • 2007
  • ${\gamma}-Oryzanol$ is one of the chain breaking antioxidants. Both sterol (triterpene) and phenolic hydroxyl groups in the structure of ${\gamma}-oryzanol$ may be responsible for its antioxidative function. We hypothesize that ${\gamma}-oryzanol$ is more effective in preventing the autoxidation of polyunsaturated fatty acid (PUFA) than the synthetic phenolic compounds in an oil/water (O/W) emulsion system. The antioxidative effectiveness of different concentrations of ${\gamma}-oryzanol$ and synthetic antioxidants was evaluated at different incubation times (0, 4, 8, 16, and 32 h) by measuring both the formation of hydroperoxides and the decomposition product of hydroperoxides (hexanal) in each emulsion system. Overall, the order of effectiveness of various antioxidants for inhibiting the formation of hydroperoxide in the O/W emulsion was: ${\gamma}-oryzanol$> tert-butylhydroquinone (TBHQ)> butylated hydroxytoluene (BHT)> butylated hydroxyanisole (BHA). O/W emulsion with selective lower concentrations of ${\gamma}-oryzanol$ showed better effectiveness than that with higher concentration of synthetic antioxidants. However, the ability of both ${\gamma}-oryzanol$ and synthetic antioxidants to decompose hydroperoxide was similar. ${\gamma}-Oryzanol$ was more effective antioxidant than the synthetic phenolic compounds in preventing the formation of hydroperoxide in the O/W emulsion system.

ON NONSINGULAR EMBRY QUARTIC MOMENT PROBLEM

  • Li, Chungji;Sun, Xiaoyun
    • Bulletin of the Korean Mathematical Society
    • /
    • v.44 no.2
    • /
    • pp.337-350
    • /
    • 2007
  • Given a collection of complex numbers ${\gamma}{\equiv}\{{\gamma}ij\}$ $(0{\leq}i+j{\leq}2n,\;|i-j|{\leq}n)$ with ${\gamma}00>0\;and\;{\gamma}ji=\bar{\gamma}ij$, we consider the moment problem for ${\gamma}$ in the case of n=2, which is referred to Embry quartic moment problem. In this note we give a partial solution for the nonsingular case of Embry quartic moment problem.

Production of ${\gamma}$-Glutamylcysteine by Immobilized Mixed Microbial System of Recombinant E. coli and Yeast (재조합 대장균과 효모의 고정화 혼합세포계에 의한 ${\gamma}$-Glutamylcysteine 생산)

  • 김원근;구윤모
    • KSBB Journal
    • /
    • v.10 no.3
    • /
    • pp.249-256
    • /
    • 1995
  • ${\gamma}$-Glutamylcysteine production by the immobilized microbial system of recombinant Escherichia coli and yeast was investigated. ${\gamma}$-Glutamylcysteine was synthesized from L-glutamic acid and L-cysteine in the presence of ATP by the reaction catalyzed by ${\gamma}$-glutamylcysteine synthetase. An immobilized microbial cell system was developed for the efficient ${\gamma}$-glutamylcysteine production. Recombinant Escherichia coli and yeast were immobilized by alginate. Production of ${\gamma}$-glutamylcysteine was better with the recombinant Escherichia coli for both the synthesis of ${\gamma}$-glutamylcysteine and the ATP regeneration than the mixed system of recombinant Escherichia coli and yeast. The proper radio of recombinant Escherichia coli to yeast was experimentary observed to be 1:4 in the mixed system. Although the immobi1ized system had the slower reaction rate, its reaction stability was increased by 10%.

  • PDF

The development of th gamma-ray imaging and operation algorithm for the gamma-ray detection system (감마선 탐지장치의 감마선 영상화 및 운용 알고리즘 개발)

  • Song, Kun-young;Hwang, Young-gwan;Lee, Nam-ho;Yuk, Young-ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.942-943
    • /
    • 2016
  • Stereo gamma ray detection system generates a two-dimensional image of the gamma ray by using the position values and the gamma ray signal. And the device will overlap with the visible light image shows the actual distribution of the gamma-ray space. The gamma ray detection device is a stereo configuration to a motion controller for controlling the signal measurement unit and the position detection portion for detecting the detection portion and the gamma-ray signal comprising a gamma-ray detection sensor. In this paper, we developed a system operation management algorithm for each module individually configured efficiently. We confirmed the imaged and distribution information output for the gamma rays from gamma-ray irradiation test site by using these results.

  • PDF