Validation of Gamma Knife Perfexion Dose Profile Distribution by a Modified Variable Ellipsoid Modeling Technique  

Hur, Beong Ik (Department of Neurosurgery, Pusan National University Hospital)
Jin, Seong Jin (Gamma-knife Center, Haeundae Paik Hospital, Inje University)
Kim, Gyeong Rip (Gamma-knife Center, Pusan National University Yangsan Hospital)
Kwak, Jong Hyeok (Department of Radiology, Pusan National University Yangsan Hospital)
Kim, Young Ha (Department of Neurosurgery, Pusan National University Yangsan Hospital)
Lee, Sang Weon (Gamma-knife Center, Pusan National University Yangsan Hospital)
Sung, Soon Ki (Gamma-knife Center, Pusan National University Yangsan Hospital)
Publication Information
Journal of Korean Neurosurgical Society / v.64, no.1, 2021 , pp. 13-22 More about this Journal
Abstract
Objective : High precision and accuracy are expected in gamma knife radiosurgery treatment. Because of the requirement of clinically applying complex radiation and dose gradients together with a rapid radiation decline, a dedicated quality assurance program is required to maintain the radiation dosimetry and geometric accuracy and to reduce all associated risk factors. This study investigates the validity of Leksell Gamma plan (LGP)10.1.1 system of 5th generation Gamma Knife Perfexion as modified variable ellipsoid modeling technique (VEMT) method. Methods : To verify LGP10.1.1 system, we compare the treatment plan program system of the Gamma Knife Perfexion, that is, the LGP, with the calculated value of the proposed modified VEMT program. To verify a modified VEMT method, we compare the distributions of the dose of Gamma Knife Perfexion measured by Gafchromic EBT3 and EBT-XD films. For verification, the center of an 80 mm radius solid water phantom is placed in the center of all sectors positioned at 16 mm, 4 mm and 8 mm; that is, the dose distribution is similar to the method used in the x, y, and z directions by the VEMT. The dose distribution in the axial direction is compared and analyzed based on Full-Width-of-Half-Maximum (FWHM) evaluation. Results : The dose profile distribution was evaluated by FWHM, and it showed an average difference of 0.104 mm for the LGP value and 0.130 mm for the EBT-XD film. Conclusion : The modified VEMT yielded consistent results in the two processes. The use of the modified VEMT as a verification tool can enable the system to stably test and operate the Gamma Knife Perfexion treatment planning system.
Keywords
Radiosurgery; Film dosimetry; Gamma knife; Perfection;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Baghani HR, Aghamiri SM, Mahdavi SR, Robatjazi M, Zadeh AR, Akbari ME, et al. : Dosimetric evaluation of gafchromic EBT2 film for breast intraoperative electron radiotherapy verification. Phys Med 31 : 37-42, 2015   DOI
2 Beck J, Berndt A : An algorithm for independent verification of Gamma Knife treatment plans. Med Phys 31 : 2780-2784, 2004   DOI
3 Casanova Borca V, Pasquino M, Russo G, Grosso P, Cante D, Sciacero P, et al. : Dosimetric characterization and use of GAFCHROMIC EBT3 film for IMRT dose verification. J Appl Clin Med Phys 14 : 4111, 2013
4 Chung JP, Oh SW, Seong YM, Chun KJ, Chung HT : An effective calibration technique for radiochromic films using a single-shot dose distribution in Gamma Knife®. Phys Med 32 : 368-378, 2016
5 Elekta : Leksell Gamma Knife Perfexion - Application Introductory Training, (Dose calculation for Leksell Gamma Knife Perfexion). Available at : https://www.elekta.com/radiosurgery/leksellgamma-knife-perfexion
6 Hur BI, Choi BK, Sung SK, Cho WH, Cha SH, Choi CH : The variable ellipsoid modeling technique as a verification method for the treatment planning system of gamma knife radiosurgery. J Korean Neurosurg Soc 47 : 128-133, 2010   DOI
7 Hur BI : Comparisons between the two dose profiles extracted from Leksell GammaPlan and calculated by variable ellipsoid modeling technique. J Korean Soc Radiol 11 : 9-17, 2017   DOI
8 Jin JY, Drzymala R, Li Z : A simple method of independent treatment time verification in gamma knife radiosurgery using integral dose. Med Phys 31 : 3337-3344, 2004   DOI
9 Khachonkham S, Dreindl R, Heilemann G, Lechner W, Fuchs H, Palmans H, et al. : Characteristic of EBT-XD and EBT3 radiochromic film dosimetry for photon and proton beams. Phys Med Biol 63 : 065007, 2018   DOI
10 Kondziolka D, Maitz AH, Niranjan A, Flickinger JC, Lunsford LD : An evaluation of the Model C gamma knife with automatic patient positioning. Neurosurgery 50 : 429-431; discussion 431-432, 2002   DOI
11 Maitz AH, Wu A, Lunsford LD, Flickinger JC, Kondziolka D, Bloomer WD : Quality assurance for Gamma Knife stereotactic radiosurgery. Int J Radiat Oncol Biol Phys 32 : 1465-1471, 1995   DOI
12 Marcu SM, Wu QJ, Pillai K, Weinhous MS : GammaPlan-Leksell Gamma Knife radiosurgery treatment planning verification method. Med Phys 27 : 2146-2149, 2000   DOI
13 Najafi M, Geraily G, Shirazi A, Esfahani M, Teimouri J : Analysis of Gafchromic EBT3 film calibration irradiated with gamma rays from different systems: Gamma Knife and Cobalt-60 unit. Med Dosim 42 : 159-168, 2017   DOI
14 Novotny J, Bhatnagar JP, Niranjan A, Quader MA, Huq Ms, Bednarz G, et al. : Dosimetric comparison of the Leksell Gamma Knife Perfexion and 4C. J Neurosurg 109 Suppl : 8-14, 2008   DOI
15 Tsai JS, Engler MJ, Rivard MJ, Mahajan A, Borden JA, Zheng Z : A formalism for independent checking of Gamma Knife dose calculations. Med Phys 28 : 1842-1849, 2001   DOI
16 Wu A, Lindner G, Maitz AH, Kalend AM, Lunsford LD, Flickinger JC, et al. : Physics of Gamma Knife approach on convergent beams in stereotactic radiosurgery. Int J Radiat Oncol Biol Phys 18 : 941-949, 1990   DOI
17 Zhang P, Dean D, Wu QJ, Sibata C : Fast verification of Gamma Knifetrade mark treatment plans. J Appl Clin Med Phys 1 : 158-164, 2000   DOI