• 제목/요약/키워드: system gamma

검색결과 1,583건 처리시간 0.03초

DSP를 이용한 모바일 TFT-LCD의 자동 감마 최적화 시스템 개발 (Development of Automatic Gamma Optimization System for Mobile TFT-LCD)

  • 조내수;류지열;박철우;권우현
    • 제어로봇시스템학회논문지
    • /
    • 제15권3호
    • /
    • pp.323-329
    • /
    • 2009
  • This paper presents an automatic LCD gamma control system using gamma curve optimization. It controls automatically gamma adjustment registers in mobile LCD driver IC to reduce gamma correction error and adjusting time. The proposed gamma system contains Module-Under-Test (MUT, LCD module), PC installed with program, multimedia display tester for measuring luminance, and control board for interface between PC and LCD module. Proposed algorithm and program are applicable for most of the LCD modules. It is realized to calibrate gamma values of 1.8, 2.0, 2.2 and 3.0. The control board is designed with DSP and FPGA, and it supports various interfaces such as RGB and CPU. Developed automatic gamma control system showed significantly reduced gamma adjusting time of 240 sec. and much less average gamma error of 11% than 42h and 27% with conventional manual method. We believe that the proposed system is very useful to provide high-quality LCD and to improve production process.

252Cf 선원을 이용한 즉발감마선 계측시스템 구성 (Development of Neutron Induced Prompt γ-ray Spectroscopy System Using 252Cf)

  • 박용준;송병철;지광용
    • 분석과학
    • /
    • 제16권1호
    • /
    • pp.12-24
    • /
    • 2003
  • $^{252}Cf$ 중성자 선원을 이용한 즉발감마선 계측 시스템 (NIPS, Neutron Induced Promp ${\gamma}$-ray Spectroscopy)을 설계 및 구성하기 위하여, 시스템내의 감속제 및 차폐체등의 효과를 시험하고 감마선 바탕값과 Cl을 포함한 시료의 즉발 감마선을 계측하였다. 이를 위한 예비시험으로 한국원자력연구소 내에 있는 TLD 판독용 $^{252}Cf$ 선원을 이용하였으며 즉발감마선은 시스템 내부의 동축형 HPGe (GMX, 60% relative efficiency)과 시스템외부 (약 20m 거리)의 Notebook PC 중성자와 감마선의 바탕값을 측정하고, 바탕값을 최소로 할 수 있는 차폐체의 기하학적 구조를 고안하였다. 감마선 바탕값을 최소화하기 위하여 두 개의 HPGe 검출기를 이용한 감마-감마 동시계측법을 이용하였다. 이 실험 자료를 이용하여 최적의 NIPS 시스템을 구성하였다.

소동물 영상화 및 환경 방사선 검출을 위한 감마카메라 개발 (Development of Gamma Camera System for Small Animal Imaging and Environmental Radiation Detection)

  • 백철하
    • 한국콘텐츠학회논문지
    • /
    • 제14권2호
    • /
    • pp.475-481
    • /
    • 2014
  • 이 연구의 목적은 감마선 검출 시스템을 개발하여 평행구멍형 조준기와 바늘구멍 조준기를 이용하여, 각각 소동물용 감마영상 획득과 환경 방사선 검출 영상을 획득하는 것이다. 본 연구에서는 크기가 $50{\times}50mm$ 이며, 6 mm 두께의 CsI(Tl) 섬광체와 $50{\times}50mm$ 크기의 Hamamatsu H8500C 위치민감형 광전자증배관, 저항분배회로, 전치증폭기, 성형증폭기, NIM 모듈 및 아날로그 디지털 변환기로 구성된 감마카메라를 개발하였다. 또한. 바늘구멍 감마카메라와 전하결합소자 카메라를 결합하여 환경모니터링에 적용할 수 있는 장비를 개발하였다. 본 연구 결과는 평행 구멍형 조준기와 바늘구멍 조준기를 이용한 감마카메라를 각각 소동물용 감마영상 획득과 환경방사선 측정에 적용 할 수 있음을 보여주었다. 이 시스템은 소 동물전용 감마카메라와 환경방사선 측정 시스템으로 활용 될 수 있을 것이다.

Validation of Gamma Knife Perfexion Dose Profile Distribution by a Modified Variable Ellipsoid Modeling Technique

  • Hur, Beong Ik;Jin, Seong Jin;Kim, Gyeong Rip;Kwak, Jong Hyeok;Kim, Young Ha;Lee, Sang Weon;Sung, Soon Ki
    • Journal of Korean Neurosurgical Society
    • /
    • 제64권1호
    • /
    • pp.13-22
    • /
    • 2021
  • Objective : High precision and accuracy are expected in gamma knife radiosurgery treatment. Because of the requirement of clinically applying complex radiation and dose gradients together with a rapid radiation decline, a dedicated quality assurance program is required to maintain the radiation dosimetry and geometric accuracy and to reduce all associated risk factors. This study investigates the validity of Leksell Gamma plan (LGP)10.1.1 system of 5th generation Gamma Knife Perfexion as modified variable ellipsoid modeling technique (VEMT) method. Methods : To verify LGP10.1.1 system, we compare the treatment plan program system of the Gamma Knife Perfexion, that is, the LGP, with the calculated value of the proposed modified VEMT program. To verify a modified VEMT method, we compare the distributions of the dose of Gamma Knife Perfexion measured by Gafchromic EBT3 and EBT-XD films. For verification, the center of an 80 mm radius solid water phantom is placed in the center of all sectors positioned at 16 mm, 4 mm and 8 mm; that is, the dose distribution is similar to the method used in the x, y, and z directions by the VEMT. The dose distribution in the axial direction is compared and analyzed based on Full-Width-of-Half-Maximum (FWHM) evaluation. Results : The dose profile distribution was evaluated by FWHM, and it showed an average difference of 0.104 mm for the LGP value and 0.130 mm for the EBT-XD film. Conclusion : The modified VEMT yielded consistent results in the two processes. The use of the modified VEMT as a verification tool can enable the system to stably test and operate the Gamma Knife Perfexion treatment planning system.

${\gamma}$계(系)의 자세(姿勢) 및 운동(運動)에 대(對)한 조절기능(調節機能)에 관(關)하여 - Stretch reflex feed back system에 있어서 ${\gamma}$계(系)의 작용(作用)을 중심(中心)으로 - (The Role of the Gamma System in Movement and Posture)

  • 김재협
    • The Korean Journal of Physiology
    • /
    • 제4권2호
    • /
    • pp.19-24
    • /
    • 1970
  • Since the discovery of the muscle spindle by Hassall (1831), an intensive studies of its anatomical and physiological characteristics had been undertaken. Recent morphological studies of Boyd (1962) demonstrated that the muscle spindles have two different intrafusal muscle fibers, nuclear bag and nuclear chain fiber, and these intrafusal fibers are under independent motor innervation by ${\gamma}_1$ and ${\gamma}_2$ motor neurone. Neurophysiological studies of Hunt and Kuffler (1951) showed regulatory effect of ${\gamma}$ motor neurone upon the excitability of the spindle afferents. Harvey and Mathews (1961) observed the dynamic and static characteristics of the two different spindle afferents, the primary and secondary ending. Furthermore, Mathews (1962) postulated the functional existance of two kind of ${\gamma}$ motor neurones, namely, the dynamic and static fusimotor fiber. Recent report of Kim and Partridge(1969) pointed out that the descending vestibular signals had increased the slope of the length-tension relationship in stretch reflex; Kim (1967) demonstrated that the descending vestibular impulses act upon the stretch reflex loop through the ${\gamma}$ motor pathway. These experimental evidences from the morphological and neurophysiological studies on the muscle spindles support the concept that the stretch reflex action of the skeletal muscle operates as a negative feedback control system. The author had discussed the way by which the f system participates in the control of stretch relfex feed back system. that was taken for a prototype of posture and movement.

  • PDF

Fast non-local means noise reduction algorithm with acceleration function for improvement of image quality in gamma camera system: A phantom study

  • Park, Chan Rok;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • 제51권3호
    • /
    • pp.719-722
    • /
    • 2019
  • Gamma-ray images generally suffer from a lot of noise because of low photon detection in the gamma camera system. The purpose of this study is to improve the image quality in gamma-ray images using a gamma camera system with a fast nonlocal means (FNLM) noise reduction algorithm with an acceleration function. The designed FNLM algorithm is based on local region considerations, including the Euclidean distance in the gamma-ray image and use of the encoded information. To evaluate the noise characteristics, the normalized noise power spectrum (NNPS), contrast-to-noise ratio (CNR), and coefficient of variation (COV) were used. According to the NNPS result, the lowest values can be obtained using the FNLM noise reduction algorithm. In addition, when the conventional methods and the FNLM noise reduction algorithm were compared, the average CNR and COV using the proposed algorithm were approximately 2.23 and 7.95 times better than those of the noisy image, respectively. In particular, the image-processing time of the FNLM noise reduction algorithm can achieve the fastest time compared with conventional noise reduction methods. The results of the image qualities related to noise characteristics demonstrated the superiority of the proposed FNLM noise reduction algorithm in a gamma camera system.

Antioxidant Activity of γ-Oryzanol and Synthetic Phenolic Compounds in an Oil/Water (O/W) Emulsion System

  • Kim, Joo-Shin
    • Preventive Nutrition and Food Science
    • /
    • 제12권3호
    • /
    • pp.173-176
    • /
    • 2007
  • ${\gamma}-Oryzanol$ is one of the chain breaking antioxidants. Both sterol (triterpene) and phenolic hydroxyl groups in the structure of ${\gamma}-oryzanol$ may be responsible for its antioxidative function. We hypothesize that ${\gamma}-oryzanol$ is more effective in preventing the autoxidation of polyunsaturated fatty acid (PUFA) than the synthetic phenolic compounds in an oil/water (O/W) emulsion system. The antioxidative effectiveness of different concentrations of ${\gamma}-oryzanol$ and synthetic antioxidants was evaluated at different incubation times (0, 4, 8, 16, and 32 h) by measuring both the formation of hydroperoxides and the decomposition product of hydroperoxides (hexanal) in each emulsion system. Overall, the order of effectiveness of various antioxidants for inhibiting the formation of hydroperoxide in the O/W emulsion was: ${\gamma}-oryzanol$> tert-butylhydroquinone (TBHQ)> butylated hydroxytoluene (BHT)> butylated hydroxyanisole (BHA). O/W emulsion with selective lower concentrations of ${\gamma}-oryzanol$ showed better effectiveness than that with higher concentration of synthetic antioxidants. However, the ability of both ${\gamma}-oryzanol$ and synthetic antioxidants to decompose hydroperoxide was similar. ${\gamma}-Oryzanol$ was more effective antioxidant than the synthetic phenolic compounds in preventing the formation of hydroperoxide in the O/W emulsion system.

ON NONSINGULAR EMBRY QUARTIC MOMENT PROBLEM

  • Li, Chungji;Sun, Xiaoyun
    • 대한수학회보
    • /
    • 제44권2호
    • /
    • pp.337-350
    • /
    • 2007
  • Given a collection of complex numbers ${\gamma}{\equiv}\{{\gamma}ij\}$ $(0{\leq}i+j{\leq}2n,\;|i-j|{\leq}n)$ with ${\gamma}00>0\;and\;{\gamma}ji=\bar{\gamma}ij$, we consider the moment problem for ${\gamma}$ in the case of n=2, which is referred to Embry quartic moment problem. In this note we give a partial solution for the nonsingular case of Embry quartic moment problem.

재조합 대장균과 효모의 고정화 혼합세포계에 의한 ${\gamma}$-Glutamylcysteine 생산 (Production of ${\gamma}$-Glutamylcysteine by Immobilized Mixed Microbial System of Recombinant E. coli and Yeast)

  • 김원근;구윤모
    • KSBB Journal
    • /
    • 제10권3호
    • /
    • pp.249-256
    • /
    • 1995
  • ${\gamma}$-Glutamylcysteine 생산에 있어서 재조합 대장 균 HB101/pGH501만을 이용한 단일세포반응계가 재조합 대장균과 효모를 이용한 흔합서l포반응계보다 반응시간이 짧고 생산농도가 높은 것으로 나타났다. 그러나 생산경제성 측면에서 ATP 재생공정을 위하 여 훈합세포반응계를 사용하였다. 재조합 대장균과 효모를 이용한 혼합세포반응계에서 대장균과 효모의 비율은 1:4가 적합함을 보였고, ATP 재생공정에 사용되는 glucose는 O.5M의 농도에서 가장 효율적 으로 나타났다. 재조합 대장균과 효모를 alginate를 이용하여 고정화하여 반응계로 사용하였을 경우 반 응에 필요한 시간이 걸어지고 생산놓도도 감소되냐 반응계의 안정성은 10% 정도 증가됨을 알 수 있었다. 실험결과 alginate로 고정화된 흔합세포반응계 를 사용하여 ${\gamma}$-glutamylcysteine를 연속 생산할 수 있음을 확인하였다.

  • PDF

감마선 탐지장치의 감마선 영상화 및 운용 알고리즘 개발 (The development of th gamma-ray imaging and operation algorithm for the gamma-ray detection system)

  • 송근영;황영관;이남호;육영호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 추계학술대회
    • /
    • pp.942-943
    • /
    • 2016
  • 스테레오 감마선 탐지장치는 감마선을 신호를 측정하여 위치값을 통한 2차원의 감마선 영상을 생성 한후, 가시광영상과 중첩하여 실제 공간상의 감마선 분포를 나타낸다. 스테레오 감마선 탐지장치는 감마선 탐지센서를 포함하는 탐지부와 감마선 신호를 검출하는 신호측정부 그리고 탐지부의 위치를 제어하기 위한 모션제어부로 구성된다. 본 논문에서는 개별적으로 구성된 각각의 모듈을 효율적으로 운용하기 위한 시스템 운용 알고리즘을 개발하였고, 이를 통해 감마선 조사시험장에서 감마선에 대한 영상화 및 분포정보 출력을 확인하였다.

  • PDF