• Title/Summary/Keyword: stenosis

Search Result 1,723, Processing Time 0.032 seconds

Coronary Artery Bypass Surgery Using Retrograde Cardioplegics (역행성 심정지액을 이용한 관상동맥 우회술)

  • Mun, Hyeon-Jong;Kim, Gi-Bong;No, Jun-Ryang
    • Journal of Chest Surgery
    • /
    • v.30 no.1
    • /
    • pp.27-33
    • /
    • 1997
  • Retrograde myocardial protection is widely accepted in CABG operation because of the limitations of the antegrade method in the coronary arterial stenosis lesions. We analyzed 76 c ses of retrograde myocardial protection among 96 cases of CABG operation performed between April 1994 and August 1995, There were 48 males and 25 females, and the mean age was 58.2 $\pm$ 8.3 years. 53 patients (70%) were operated for unstable angina, 14 (18%) for stable angina, 6 (8%) for post-infarct angina, 1 (1%) for acute myocardial infarction, and 2()%) for failed PTCA. Preoperative coronary angiography revealed 3-vessel disease in 42 cases, 2-vessel disease in 11, 1-vessel disease in 10, and left main disease in 13 cases. We used SVG(63 cases), LIMA(69 cases), RIMA(11 cases), radial artery(6 cases), and gastroepiploic artery(1 case) for the grafts. Mean anastomosis was 3.2 $\pm$ 1.1. We protected the myocardium with antegrade induction and retrograde maintenance in all the cases except a case of retrograde induction and maintenance. During the aortic cross-clamping, blood cardioplegia was administered intermittently in 19 cases, and continuously in 57 In 39 cases, we used retrograde ardioplegia and antegrade perfusion of RCA graft simultaneously. We had no operative motality. Perioperative complications were arrhythmia in 15 cases, perioperatve myocardial infarction in 10, low cardiac output syndrome In 8, transient neurologic problem in 7, transient psychiatric problem in 6, ARF in 3, bleeding in 2, pneumonia in 2, wound infection in 1, and duodenal ulcer perforation in 1 . In this report, we experienced 76 cases of CABG operation with retrograde myocardial protection under the acceptable operative risk without operative mortality.

  • PDF

Modified Blalock-Taussig Shunt in Neonates (신생아에서 변형 Blalock-Taussig 단락술)

  • 조광조;성시찬
    • Journal of Chest Surgery
    • /
    • v.30 no.4
    • /
    • pp.378-382
    • /
    • 1997
  • To evaulate the effectiveness and risk factors for shunt failure of the Blalock-Taussig shunt in neonates, we analyzed the 21 neonates who were undergone Blalok-Taussig shunt operation at Dong-A University Hospital from December 1991 to Feburary 1996. We evaluated operative mortality, patency of the shunt. and distortion of pulmonary artery. We also determined the risk factors for the shunt failure. Age at operation was from 1 day to 30 days(mean 11.7 days). We ghts were 2.4 to 4.5kg(mean 3.1 kg). The underlying lesions included severe tetralogy of Fallot with pulmonary stenosls or atresia(N=11) and single ventricle varieties with. pulmonary stenosis or atresia(N=10). Prostaglandin El was given in 13 neonates prior to operation. The mean preoperative(prior to prostaglandin El therapy) and postoperative arterial oxygen tension were 30.1 mmHg and 46.3 mmHg respectively(P(0.01). The shunt was performed through a left thoracotomy in 11 patients and through a right thoracotomy In 10. A 5 mm graft was used in 15 patients and a 4 mm graft in 6 patients. The incidence of early shunt occlusion was 9.5%(2 patients). The hospital mortality was 9.5%(2 patients with early shunt occlusion). Univariate analysis revealed that body weight of 2.6 kg or less(p=0.021), pulmonary artery size of 3mm or less(p=0.008), and 4 mm graft (p=0.021) were risk factors predictive of early shunt failure. The patency rate of the shunt in hospital survivors was 100% at mean ollow-up of ll.3 months(There was not death or reoperation related to shunt failure). 10 patients were catheterized during postoperative follow-up. There was no significant distorsion of pulmonary artery. So we concluded that the modified Blalock-Taussig shunt in neonates was excellent in the hospital survivors.

  • PDF

Analysis of Suitability of Radial Artery Graft as Bypass Conduit after Transradial Catheterization (관상동맥조영술에 사용된 요골동맥의 우회도관으로서의 적합성에 대한 분석)

  • 신윤철;이동석;지현근;김응중
    • Journal of Chest Surgery
    • /
    • v.37 no.11
    • /
    • pp.897-902
    • /
    • 2004
  • Background: Although great concerns have been raised regarding the suitability of the use of the radial artery as a bypass conduit after transradial catheterization, there has been no studies that examined this issue in Korea. The purpose of this study was to compare clinical and angiographic results of radial artery grafting between patients with and without previous transradial catheterization. Material and Method: From January 2000 to February 2004, a total of 93 patients underwent coronary artery bypass grafting using the radial artery: 49 patients received preoperative transradial catheterization for coronary angiography (group I) and 44 patients did not (group II). These patients were retrospectively reviewed. Result: There was no significant difference in sex ratio, age, clinical diagnosis, risk factors, ejection fraction and early clinical outcomes between two groups. The graft patency rates in groups I and II were both 100% in the internal thoracic artery and in the radial artery, and 85% and 86% in the saphenous vein. respectively. The stenosis-free graft patency in groups I and II were 93% and 81% in the radial artery respectively but no statistical significance was shown. Conclusion: There was no significant difference in graft patency at postoperative coronary angiography between two groups. Radial artery graft after transradial catherization seems to be suitable for bypass conduit in short-term analysis.

Aortic Valvuloplasty in Pediatric Age (소아연령군에서의 대동맥판막성형술)

  • 임홍국;박천수;황호영;김웅한;이정렬;노준량;김용진
    • Journal of Chest Surgery
    • /
    • v.37 no.8
    • /
    • pp.652-659
    • /
    • 2004
  • Background: In this study, we retrospectively analyzed the outcomes of aortic valvuloplasty in pediatric age. Material and Method: Between January 1993 and March 2004, 35 patients underwent aortic valvuloplasty for aortic stenosis (AS) or aortic regurgitation (AR). The mean age was 81.1$\pm$61.5 (1∼223) months. The mean follow up was 50.8$\pm$30.2 (3∼121) months. Nine patients had AS, 21 had AR, and 6 had AS and AR. Valve morphology was tricuspid in 24 patients, bicuspid in 9, quadricuspid in 1, and unicuspid in 1. The mean peak pressure gradients of AS were 72.0$\pm$33.0 mmHg, and the mean grades of AR were 3.1$\pm$0.9. Result: There was one late mortality without early mortality. After operation, AS improved with mean peak pressure gradients of 23.5$\pm$21.0 mmHg (p < 0.05), and AR improved with mean grades of 1.9$\pm$0.8 (p < 0.05). At mean follow up of 35.0$\pm$23.0 months, AS maintained with mean peak pressure gradients of 31.5$\pm$24.0 mmHg, but AR progressed with mean grades of 2.8$\pm$1.3 (p < 0.05). Reoperation was required in 6 patients 38.3$\pm$21.8 months after the original operation. The actuarial figures for freedom from reoperation at 2, 5 and 8 years were 96.9$\pm$3.1%, 79.5$\pm$5.5%, and 56.8$\pm$11.4%, respectively. Age at operation, presence of AS, preoperative severity of AS or AR, and morphology of aortic valve were not significant risk factors for reoperation, and improvement of AS or AR. Conclusion: Aortic valvuloplasty showed good immediate postoperative valve function. Aortic valvuloplasty offers children many years with tolerable valve function and allows to postpone aortic valve replacement or Ross procedure in pediatric patients.

Total Arterial Revascularization Using Y-composite Graft for Isolated Left Main Coronary Artery Disease (단독 좌주간 관동맥 협착병변에서 Y-도관을 이용한 완전 동맥도관 관상동맥우회로 조성술)

  • Ahn, Byong-Hee;Yu, Ung;Chun, Joon-Kyung;Ryu, Sang-Wan;Choi, Yong-Sun;Kim, Byong-Pyo;Hong, Sung-Bum;Bum, Min-Sun;Na, Kook-Ju;Jung, Myung-Ho;Kim, Sang-Hyung
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.35-42
    • /
    • 2004
  • Background: For the treatment of isolated left main coronary artery disease, twelve arterial revascularizations with Y-composite grafts using left internal thoracic artery and radial artery or right gastroepiploic artery were peformed. This study was performed to investigate whether V-composite graft can satisfy the blood flow required to make myocardium act properly or not. Borderline stenotic lesions on the left main coronary artery, which are very prone to remodel the bypassed vessels due to competitive flows, were also considered. Material and Method: Among 247 patients who underwent coronary artery bypass grafting from March 2000 to April 2003, 12 patients (4.7%) who had received total arterial revascularizations for the isolated left main coronary artery disease were studied retrospectively. Result: left anterior descending arteries were bypassed with left internal thoracic artery by off-pump technique in all patients, however, 2 cases of left obtuse marginal branches were bypassed under on-pump beating heart. Except for one patient, who did not have an obtuse marginal branch more than 1 mm in diameter, 11 patients had gone through complete arterial revascularizations by use of the Y shape arterial graft. Among five patients who had less than 75% stenosis, one patient showed string sign on left internal thoracic artery grafted to left anterior descending artery. However, two grafts to obtuse marginal blanches were completely obstructed and one showed slender sign. There were no graft-dominant flow in patients with stenotic lesion less than 75%. On the contrary to the result of patients with stenotic lesions less than 75%, all the patients with stenotic lesions more than 90% showed graft-dominant blood flow. Conclusion: In conclusion, it is assumed that, when stenotic lesions are over 90%, coronary artery bypass grafting with an Y shape arterial graft could possibly give enough help to the obstructed coronary arteries in blood supplying to myocardium, which needs massive quantity of blood to act well. However, when patients have borderline stenoses, through scrupulous examinations, more prudent and flexible decisions are required in choosing the treatment methods, such as, direct anastomosis of vein or artery to aorta, or adding supplementary treatment methods like percutaneous coronary intervention, rather than choosing a fixed treatment methods.

Analysis of 1,000 Cases of Abdominal Ultrasonography Performed by a Pediatrician (소아과 의사에 의해 시행된 복부 초음파 검사 1,000예에 대한 분석)

  • Bae, Sang-In;Park, Jae-Hong
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.10 no.1
    • /
    • pp.28-35
    • /
    • 2007
  • Purpose: The aim of this study was to evaluate the clinical usefulness of ultrasound examination of children performed by a pediatrician. Methods: One thousand children who presented with symptoms of a gastrointestinal disorder and underwent abdominal ultrasound evaluation in the Department of Pediatrics, between January 2003 and June 2006, were included in this study. We analyzed the patient's medical records and ultrasound results retrospectively. Results: Among the 1,000 patients, 58.4% were male and 41.6% were female. The mean age of the patients was $4.7{\pm}4.0$ years. The main reasons for ultrasound were abdominal pain (43.9%), vomiting (17.3%), elevated liver enzymes (11.8%), and jaundice (9.8%). Abnormal ultrasound findings were present in 57.9% of cases. The major abnormal findings were mesenteric lymphadenitis (29.2%), fatty liver (12.1%), hepatitis (6.4%), hepatosplenomegaly (6.2%), and acute appendicitis (4.8%). The time interval between the initial medical evaluation and the ultrasound evaluation was within 24 hours in most cases (78.5%). The main findings in children with abdominal pain were mesenteric lymphadenitis (32.6%), fatty liver (5.9%), intussusception (2.7%), and acute appendicitis (2.7%). The main findings in children with vomiting were mesenteric lymphadenitis (12.7%), hypertrophic pyloric stenosis (10.4%), and acute appendicitis (3.5%). The major ultrasound findings in children with urinary tract diseases were hydronephrosis (45.4%), urolithiasis (21.5%) and cystic renal disease (18.1%). Conclusion: Ultrasound examination played an important role as a non-invasive and prompt screening examination for detection of abdominal diseases. Ultrasound was an important tool for pediatricians to determine timely information for patient management.

  • PDF

Clinic Analysis of Heart Surgery -110 cases- (심장수술 110례 임상고찰)

  • Chang, Hoon;Shin, Sung-Aia;No, Joong-Kee;Rho, Jun-Ryang
    • Journal of Chest Surgery
    • /
    • v.34 no.8
    • /
    • pp.597-603
    • /
    • 2001
  • Background: The purpose of writing this article is to get better clinical results and further clinical improvement based on subject to 110 cases of cardiac surgery which were performed and clinically analyzed. Material and Method: Since January 1995, the patent ductus arteriosus surgery had started in our hospital. In February 1999, an open heart surgery had started and up to September 2000, total of 110 cases were performed as of double ligation of patent ductus arteriosus(10 cases) and open heart surgery(100 cases). Result: Among the patients, Korean-Chines was 74(67.3%) and Han-Chinese was 35(31.8%). Congenital heart disease was 95 cases and acquired valvular heart disease was 15 cases. 83 cases of acyanotic congenital heart disease consisted of ventricular septal defect(VSD) with associated anomaly(45 cases), atrial septal defect(ASD) with associated anomaly(20 cases), patent ductus arteriosus(PDA) with associated anomaly(11 cases), cogenital aortic stenosis(5 cases), double chamber right ventrical(1 case) and Ebstein's anomaly(1 case). Among the 12 cases of cyanotic congenital heart disease, 11 cases of tetralogy of Fallot underwent total correction. Among the 15 cases of acquired valvular heart disease, valvular replacement(7 cases), double valve replacement (3 cases), mitral valve replacement(3 cases) and aortic valve replacement(1 case) were performed. And 8 cases of valvuloplasty were performed by using of commissurotomy, chordal plasty, plasty of papillary muscle, ring type annuloplasty, repair of leaflet. Conclusion: on cogenital heart disease, short term results of surgery for acyanotic cogenital heart disease was good. Among the cyanotic congenital heart disease, tetralogy of Fallot showed a little difference of recovery according to the surgery method so that further follow up observation was needed for long term result. On acquired valvular heart disease, especially, in terms of short term result of valvuloplasty, was relatively good, but further follow up observation was also needed for long term result. There wasn's any operative mortality.

  • PDF

Gender Difference of Accuracy in Detecting Coronary Artery Disease by Myocardial Perfusion SPECT (디피리다몰 심근관류 SPECT를 이용한 관동맥질환 진단에 있어 남녀간의 진단율 비교)

  • Min, Jung-Jun;Bom, Hee-Seung;Song, Ho-Cheon;Jeong, Hwan-Jeong;Kim, Ji-Yeul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.2
    • /
    • pp.129-136
    • /
    • 1998
  • Purpose: Myocardial SPECT is an effective test for detecting coronary artery disease in the general population. But the diagnostic accuracy between sexes is not defined. The purpose of this study is to compare the diagnostic accuracy between males and females. Materials and Methods: One hundred and seventy seven male and 98 female patients who underwent myocardial SPECT within 1 month of coronary angiography were studied. Myocardial SPECTS were considered abnormal if fixed or reversible perfusion defects were detected. Stenosis severity of ${\geq}$ 50% luminal diameter reduction of any artery defined coronary artery disease (CAD). Results: Overall sensitivity for detection of CAD was 98% in men and 97% in women (p=not significant). However, specificities, accuracies, and positive predictive values (PPV) in men and women were 49% vs 31% (p<0.05), 81% vs 57% (p<0.01), 78% vs 48% (p<0.01), respectively. Diagnostic accuracies for detection of right coronary artery disease were not different in both sexes, however, accuracies for detection of left anterior descending artery disease and left circumflex artery disease were significantly lower in female (p<0.05). Conclusion: A significant difference of diagnostic accuracy between sexes, especially in LAD and LCx disease, was noted. Artifacts from breast attenuation might be a cause for the lower diagnostic accuracy in female.

  • PDF

Small Aortic Annulus in Aortic Valve Replacement; Comparison between Aortic Annular Enlargement Group and Patient-prosthesis Mismatch Group (협소한 대동맥판륜 환자에서의 대동맥판막 치환술; 대동맥판륜 확장술군과 환자-인공판막 부조화군의 비교)

  • Kim, Jae-Hyun;Oh, Sam-Sae;Yie, Kil-Soo;Shin, Sung-Ho;Baek, Man-Jong;Na, Chan-Young
    • Journal of Chest Surgery
    • /
    • v.40 no.3 s.272
    • /
    • pp.200-208
    • /
    • 2007
  • Background: The effect of patient-prosthesis mismatch (PPM) on the clinical outcome following aortic valve replacement (AVR) remains controversial. This study compared the surgical outcomes of AVR between patients with a patient-prosthesis mismatch and those having undergone an aortic annular enlargement. Material and Method: Six hundred and twenty seven adult patients, who underwent AVR with stented bioprosthetic or mechanical valves, between January 1996 and February 2006, were evaluated. PPM was defined as an indexed effective orifice area (iEOA) ${\leq}0.85cm^2/m^2$, and Severe if the iEOA${\leq}0.65cm^2/m^2$ PPM was present in 103 (16.4%, PPM group) patients, and severe in 11 (1.8%, SPPM group). During the period of the study, 21 patients underwent an AVR with annular enlargement (AE group). Result: The mean iEOA of the AE group was larger than that of the PPM group ($0.95\;vs.\;0.76cm^2/m^2,\;p=0.00$). The AE group had longer CPB, ACC and operation times than the PPM group, and showed a tendency toward higher operative mortality (14.3% vs. 2.9%, p=0.06). The SPPM group had higher AV pressure gradients (peak/mean) than the AE group (72/45 mmHg vs. 38/25 mmHg, p=0.02/0.06) and suffered more AV related events (AV reoperation or severe aortic stenosis)(45.5% vs. 9.5%, p=0.03). LV masses were not regressed in the patients who experienced an AV related event. Conclusion: During AVR in patients with a small aortic annulus, annular enlargement should be carefully applied taking into account the high risk of operative mortality due to annular enlargement and co-morbidities of patients. Aortic annular enlargement; however, should be considered as an alternative method in patients expected to have a severe PPM after an AVR.

Arterial Switch Operation in Patients with Intramural Coronary Artery: Early and Mid-term Results

  • Kim, Hyung-Tae;Sung, Si-Chan;Kim, Si-Ho;Chang, Yun-Hee;Ahn, Hyo-Yeong;Lee, Hyoung-Doo
    • Journal of Chest Surgery
    • /
    • v.44 no.2
    • /
    • pp.115-122
    • /
    • 2011
  • Background: The intramural coronary artery has been known as a risk factor for early death after an arterial switch operation (ASO). We reviewed the morphological characteristics and evaluated the early and mid-term results of ASO for patients with an intramural coronary artery. Materials and Methods: From March 1994 to September 15th 2010, 158 patients underwent ASO at Dong-A and Pusan National University Hospitals for repair of transposition of the great arteries and double outlet right ventricle. Among these patients, 14 patients (8.9%) had an intramural coronary artery. Mean age at operation was $13.4{\pm}10.2$ days (4 to 39 days) and mean body weight was $3.48{\pm}0.33$ kg (2.88 to 3.88 kg). All patients except one were male. Eight patients had TGA/IVS and 4 patients had an aortic arch anomaly. Two patients (14.3%) had side-by-side great artery relation, of whom one had an intramural right coronary artery and the other had an intramural left anterior descending coronary artery. Twelve patients had anterior-posterior relation, all of whom had an intramural left coronary artery (LCA). The aortocoronary flap technique was used in coronary transfer in 8 patients, of whom one patient required a switch to the individual coronary button technique 2 days after operation because of myocardial ischemia. An individual coronary button implantation technique was adopted in 6, of whom 2 patients required left subclavian artery free graft to LCA during the same operation due to LCA injury during coronary button mobilization and LCA torsion. Results: There was 1 operative death (7.1%), which occurred in the first patient in our series. This patient underwent an aortocoronary flap procedure for coronary transfer combining aortic arch repair. Overall operative mortality for 144 patients without an intramural coronary artery was 13.2% (19/144). There was no statistical difference in operative mortality between the patients with and without an intramural coronary artery (p>0.1). There was no late death. The mean follow-up duration was $52.1{\pm}43.0$ months (0.5 to 132 months). One patient who had a subclavian artery free graft required LCA stenting 6.5 years after surgery for LCA anastomotic site stenosis. No other surviving patient needed any intervention for coronary problems. All patients had normal ventricular function at latest echocardiography and were in NYHA class 1. Conclusion: The arterial switch operation in Transposition of Great Arteries or Double Outlet Right Ventricle patients with intramural coronary can be performed with low mortality; however, there is a high incidence of intraoperative or postoperative coronary problems, which can be managed with conversion to the individual coronary button technique and a bypass procedure using a left subclavian free graft. Both aortocoronary flap and individual coronary button implantation techniques for coronary transfer have excellent mid-term results.