• 제목/요약/키워드: standard fire testing

검색결과 44건 처리시간 0.025초

Analysis of multiple spurious operation scenarios of Korean PHWRs using guidelines of nuclear power plants in U.S.

  • Kim, Jaehwan;Jin, Sukyeong;Kim, Seongchan;Bae, Yeonkyoung
    • Nuclear Engineering and Technology
    • /
    • 제51권7호
    • /
    • pp.1765-1775
    • /
    • 2019
  • Multiple spurious operations (MSOs) mean multiple fire induced circuit faults causing an undesired operation of one or more systems or components. The Nuclear Energy Institute (NEI) of the United States published NEI 00-01 as guidelines for solving MSOs. And this guideline includes MSO scenarios of pressurized water reactor (PWR) and boiling water reactor (BWR). Nuclear power plant operators in U.S. analyzed MSOs under MSO scenarios included in NEI 00-01 and operators of PWRs in Korea also analyzed MSOs under the scenarios of NEI 00-01. As there are no pressurized heavy water reactors (PHWRs) in the United States, MSO scenarios of PHWRs are not included in the NEI 00-01 and any feasible scenarios have not been developed. This paper developed MSO scenarios which can be applied to PHWRs by reviewing the 63 MSO scenarios included in NEI 00-01. This study found that seven scenarios out of the 63 MSO scenarios can be applied and three more scenarios need to be developed.

이산화탄소 소화설비 현장 방출시험 방법론에 관한 고찰 (A Study on On-site Discharge Testing for Carbon Dioxide Fire Extinguishing Systems)

  • 박준현;강태석;김재환;김위경
    • 한국화재소방학회논문지
    • /
    • 제29권4호
    • /
    • pp.26-32
    • /
    • 2015
  • 이산화탄소 소화설비는 질식소화가 주된 소화작용이므로 제한된 시간 내에 소화약제를 방출하여 방호구역의 산소농도를 기준치 이하로 유지시키는 능력이 확보되어야 한다. 국내에서 이산화탄소 소화설비는 국민안전처 고시에 따라 인증된 설계프로그램을 사용하여 소화설비를 설계하고 있다. 그러나 소화설비가 설치된 방호구역의 기하학적 구조는 성능인증 단계의 모의실험장치와 차이가 있기 때문에 설계프로그램 적용 범위를 벗어난 소화설비 설계가 이루어질 수 있다. 특히, 저압식 이산화탄소 소화설비는 배관 내 유동현상에 따라 소화약제 방출량이 변하므로 소화설비 설치 후에 현장 방출시험을 통하여 성능을 확인할 필요가 있다. 현재까지 국내 외 기술기준에는 방출시험에 대한 방법론이 구체적으로 명시되어 있지 않다. 본 논문에서는 국내외 기술기준을 비교 분석하고, 방출시험 사례분석을 통하여 현장 방출시험 방법론을 제시하였다.

내화피복을 적용한 강합성보의 구조화재해석 (Structural Fire Analysis of a Composite Beam Protected by Fire-Resistant Materials)

  • 강준원;강문수;윤혜진
    • 한국전산구조공학회논문집
    • /
    • 제36권2호
    • /
    • pp.137-145
    • /
    • 2023
  • 이 논문은 정적 재하상태에 있는 무피복 강합성보와 내화피복을 적용한 강합성보를 대상으로 화재 시 내부 온도 및 수직처짐에 대한 내화피복의 영향을 평가한 결과를 제시한다. 열응력해석을 위한 화재하중으로는 American Society for Testing and Materials E119의 표준화재곡선을 사용했으며, 강재거더 표면에 부착하는 내화재료의 방화효과를 구현하기 위해 외기에서 강합성보로 전달되는 열의 전달계수를 감소시켰다. 실규모 무피복 강합성보에 대한 구조화재실험에서 내부 온도분포와 수직처짐을 측정하였고 실험 결과와의 비교를 통해 비선형 구조화재해석 결과의 타당성을 검증하였다. 내화피복이 적용된 강합성보의 구조화재해석 결과로부터 강재거더 표면에 내화재를 적용할 경우 동일 화재 조건에서 무피복 강합성보에 비해 내부 온도와 수직처짐이 감소함을 알 수 있었다. 또한 열전달계수의 변화에 따른 열응력 응답으로부터 화재 시 강합성보의 온도 및 구조거동에 대한 내화피복의 영향을 제시하였다.

한국 A급, B급 1단위 화재 시험시 발생하는 일산화탄소 등의 정량적 연구 (A Study on Carbon Monoxide and Other Gases During the Fire Test (A-class:1st Rating & B-class:1st Rating))

  • 정인천;정영진
    • 한국화재소방학회논문지
    • /
    • 제27권5호
    • /
    • pp.44-56
    • /
    • 2013
  • 한국기준 표준화된 A급 목재 및 B급 유류 화재 시험에서 룸코너시험기(RCT)를 사용하여 연소유독가스의 생성을 정량적으로 알아보고, 시험자들에게 미치는 인체유해성을 확인하였다. 그 결과 A급의 경우 유독가스가 시험자들에 직접적으로 노출되는 초기 3분 동안, 분당호흡량(RMV) 2단계에서 40% 카복시헤모글로빈(COHb)가 넘어가는 경우는 A급 9, 10단위에 해당하며, RMV 3단계에서 A급 5~10 단위까지가 모두 40% COHb을 초과함을 확인하였다. 한편 B급의 경우 유독가스가 시험자에게 직접 노출되는 초기 1분 동안은 A급에 비해 다소 안전하나 총 연소시간에는 RMV 3단계에서 B급 16~20 단위까지가 모두 20% COHb을 초과한 수치가 나옴을 확인하였다. 따라서 이 연구에서는 시험자들은 소화시험의 단위수를 고려하여 자급 호흡보조기나 그와 동일한 기능의 장치를 착용하는 규정을 제안한다.

Structural performance of unprotected concrete-filled steel hollow sections in fire: A review and meta-analysis of available test data

  • Rush, David;Bisby, Luke;Jowsey, Allan;Melandinos, Athan;Lane, Barbara
    • Steel and Composite Structures
    • /
    • 제12권4호
    • /
    • pp.325-350
    • /
    • 2012
  • Concrete filled steel hollow structural sections (CFSs) are an efficient, sustainable, and attractive option for both ambient temperature and fire resistance design of columns in multi-storey buildings and are becoming increasingly common in modern construction practice around the world. Whilst the design of these sections at ambient temperatures is reasonably well understood, and models to predict the strength and failure modes of these elements at ambient temperatures correlate well with observations from tests, this appears not to be true in the case of fire resistant design. This paper reviews available data from furnace tests on CFS columns and assesses the statistical confidence in available fire resistance design models/approaches used in North America and Europe. This is done using a meta-analysis comparing the available experimental data from large-scale standard fire tests performed around the world against fire resistance predictions from design codes. It is shown that available design approaches carry a very large uncertainty of prediction, suggesting that they fail to properly account for fundamental aspects of the underlying thermal response and/or structural mechanics during fire. Current North American fire resistance design approaches for CFS columns are shown to be considerably less conservative, on average, than those used in Europe.

철도 차량 화재 예방 규정 사례 연구 (Case study of fire precautions Regulation for Rolling stock)

  • 이수호;이병석;임용규
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 춘계학술대회 논문집
    • /
    • pp.604-609
    • /
    • 2003
  • The fire precautions regulation for Rolling stock in England, France and America concentrate on ensuring of safety in respect of material choosing method and consideration of design. In order to guarantee fire safety in Korean Rolling stocks, it is necessary to establish the fire precautions regulation at the two respects. Korean Standard of product classifies only incombustibility or not. It is not sufficient to classify various materials by testing method for incombustibility of material. Korean Standard to be reserved should be able to cover the smoke density test for small size and classification of the detail grade of material against the reaction to fire

  • PDF

지하구 케이블의 연소특성 실험 (Experiments on the Behavior of Underground Utility Cable in Fire)

  • 박승민;김운형;윤명오
    • 한국화재소방학회논문지
    • /
    • 제16권2호
    • /
    • pp.75-80
    • /
    • 2002
  • 지하공동구에 사용되는 케이블의 연소특성 중 열방출량과 연기 유독성 실험을 수행하였다. 열 방출량 실험은 22.9 kv 전력용 케이블을 대상으로 ISO 9705 규격의 공간에서 수행하였으며 유독성가스의 정량적 위험성 평가를 위하여 NES 713(British-Naval Engineering Standard)을 적용하였다. 실험 결과 측정높이 1.2 m를 기준으로 계산한 케이블의 열 방출 율은 60 kW로 예측되었다. 한편, 케이블의 연기유독성을 위한 NES 실험 결과, 인체에 치명적인 CO의 경우 30분 노출시 사망에 이를 수 있고 의식불명상태가 될 수 있는 수준으로 판정되었다

뿜칠 피복 원형 철골구조의 비재하 내화성능 평가용 시험체 제안을 위한 연구 (Study of the Standard Testing Specifications for a Non-loading Performance Evaluation of Coating Material-sprayed Circular Steel Structures)

  • 옥치열;김재준
    • 한국화재소방학회논문지
    • /
    • 제30권3호
    • /
    • pp.7-15
    • /
    • 2016
  • 단면형상계수는 세계적으로 흔하게 활용되는 공학적 내화구조 성능평가 방법이지만 국내의 경우 단면형상계수의 적용을 위한 제도가 아직 마련되어 있지 못하다. 실제 우리나라의 대부분의 철골조 건축물에서 원형 강관의 사용을 흔히 볼 수 있으나, 인정기관으로부터 성능을 인정받은 뿜칠 피복 철골 보 및 기둥은 대부분이 H형강으로 한정되어 있다. 비재하 시험의 특성상 H형강은 관련규정에 따른 시험규격으로 부재에 대한 평가를 수행하여 크기의 제한 없이 인정범위가 부여되나, 이형 강관의 경우는 형상별로 별도의 내화성능에 대한 인정을 받아야 한다. 본 연구에서는 합리적인 내화구조의 인정범위를 설정할 수 있도록 단면형상계수를 활용하여 뿜칠 피복재의 원형 강관의 적용을 위한 표준 시험체 규격을 제시하고자 한다.

가스계 소화설비의 제한사항 및 성능평가를 위한 배관 내 약제비율에 관한 연구 (A Study on Percent Agent in Pipe as a Criterion to Evaluate Limitations and Performance of Gaseous Fire Extinguishing Systems)

  • 손봉세;김희우
    • 한국화재소방학회논문지
    • /
    • 제21권4호
    • /
    • pp.1-11
    • /
    • 2007
  • 본 연구에서는 할론 1301 및 이산화탄소를 비롯한 가스계소화설비의 성능을 시험하고 평가하기 위한 가장 중요한 핵심 요소인 배관내 약제비율, 관경비 등 소화성능에 영향을 미치는 가스계소화설비의 제한사항 및 성능확보에 필요한 요소에 대하여 연구하였다. 또한 본 연구에서는 관련 국내외 기준 분석 및 국내 가스계소화설비의 성능평가에 관한 인정기준(KFIS 002)에 따른 시스템 성능시험을 실시하고 결과를 비교 분석하였다.

FDS 열분해 모델을 이용한 콘칼로리미터(ISO 5660) 화재 시뮬레이션 (Fire Simulation by Pyrolysis Method of FDS for the Small Cone Calorimeter (ISO 5660))

  • 양성진;장정훈;강찬용
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.206-212
    • /
    • 2009
  • Chemical behaviors of each surface material for interior facilities affect to fire initiation and growth in general fire situation. These chemical behaviors were characterized by thermal properties (Heat release rate, Pyrolysis rate, specific heat, etc) which could be derived from experimental test. Especially, Heat release rate which indicates aspect of fire size is one of the most important property to asses fire hazard and protection needs. The cone calorimeter test (ISO 5660) has recently assumed to a dominant role in bench scale fire testing to obtain the Heat release rate of materials. This value could be calculated by the 'Oxygen Consumption Method' under various producing irradiances to each surface of materials. In this study, Process of the cone calorimeter test was simulated by Pyrolysis model of FDS (Fire Dynamics Simulator by NIST) base on the ISO 5660 international standard. Then, we could estimate the simulation method of FDS in case of single materials through the comparative study with test results.

  • PDF