A Study on On-site Discharge Testing for Carbon Dioxide Fire Extinguishing Systems

이산화탄소 소화설비 현장 방출시험 방법론에 관한 고찰

  • 박준현 ((주)스탠더드시험연구소) ;
  • 강태석 ((주)스탠더드시험연구소) ;
  • 김재환 ((주)스탠더드시험연구소) ;
  • 김위경 (한국원자력안전기술원)
  • Received : 2015.05.19
  • Accepted : 2015.08.11
  • Published : 2015.08.31

Abstract

Carbon dioxide principally extinguishes fires by smothering, but an acceptable amount of extinguishing agent is needed. To assure the performance of carbon dioxide systems in Korea, computer programs certified by NEMA are being applied in system design. But the design errors can occur because the geometry of a model test facility is not the same as that of the actual fire area. Since the discharge rate tends to vary considerably with the flow pattern in a pipe, an on-site discharge test is necessary to ensure the performance of the system, especially with low pressure carbon dioxide. Technical standards for carbon dioxide systems do not give detailed guidelines for discharge tests at present. Based on comparative analysis of standards and practical tests, this paper suggests a methodology for on-site discharge tests.

이산화탄소 소화설비는 질식소화가 주된 소화작용이므로 제한된 시간 내에 소화약제를 방출하여 방호구역의 산소농도를 기준치 이하로 유지시키는 능력이 확보되어야 한다. 국내에서 이산화탄소 소화설비는 국민안전처 고시에 따라 인증된 설계프로그램을 사용하여 소화설비를 설계하고 있다. 그러나 소화설비가 설치된 방호구역의 기하학적 구조는 성능인증 단계의 모의실험장치와 차이가 있기 때문에 설계프로그램 적용 범위를 벗어난 소화설비 설계가 이루어질 수 있다. 특히, 저압식 이산화탄소 소화설비는 배관 내 유동현상에 따라 소화약제 방출량이 변하므로 소화설비 설치 후에 현장 방출시험을 통하여 성능을 확인할 필요가 있다. 현재까지 국내 외 기술기준에는 방출시험에 대한 방법론이 구체적으로 명시되어 있지 않다. 본 논문에서는 국내외 기술기준을 비교 분석하고, 방출시험 사례분석을 통하여 현장 방출시험 방법론을 제시하였다.

Keywords

References

  1. NEMA, "The Certification Performance of Design Program and the Technical Standard of Product Inspection of Gas Extinguishing Systems", NEMA Notice 2012-11 (2012).
  2. NEMA, "National Fire Safety Code of Carbon Dioxide Fire Extinguishing System", NFSC 106 (2013).
  3. FM, "Standard for Carbon Dioxide Extinguishing Systems", FM 5420 (2007).
  4. NFPA, "Standard on Carbon Dioxide Extinguishing Systems", NFPA 12 (2011).
  5. ISO, "Fire protection equipment-Carbon dioxide extinguishing systems for use on premises-Design and installation", ISO 6183 (2009).
  6. KINS, "Technical Report on Discharge Testing Plan for Shin-kori 2, Shin-wolsong 1&2 Carbon Dioxide Extinguishing Systems" (2013).
  7. KINS, "Technical Report on Discharge Testing for Shinkori 2 Carbon Dioxide Extinguishing Systems" (2010).
  8. R. Zalosh and C. W. Hung, "Carbon Dioxide Discharge Test Modeling", Worcester Polytechnic Institute, Fire Safety Science-4th International Symposium, PP 889-900 (1994).
  9. W. K. Kim and K. S. Doh, "Theoretical Study and Discharge Testing for Agent Discharge Amount of Gaseous Fire Extinguishing System (I)", 2013 Fall Conference, KIFSE, pp. 69-70 (2013).
  10. J. S. Ma, "A Performance Evaluation of Low Pressure Carbon Dioxide System based on Early-Air-Release Method for Emergency Diesel Generator Room in NPPs", Doctoral thesis, Jeonju University (2013).
  11. USNRC, "Inadequate Fire Suppression System Testing", Information Notice 92-28 (1992).
  12. ANSUL, "Carbon Dioxide Fire Suppression Systems", Brochure (2004).
  13. http://www.witantincendio.it, "Door Fan Test".
  14. ASTM, "Standard Test Method for Determining Air Change in a Single Zone by Means of a Tracer Gas Dilution", ASTM E 741 (2006).