• Title/Summary/Keyword: source static

Search Result 417, Processing Time 0.027 seconds

Cost-Effective APF/UPS System with Seamless Mode Transfer

  • Lee, Woo-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.195-204
    • /
    • 2015
  • In this paper, the development of a cost-effective active power filter/uninterruptible power supply (APF/UPS) system with seamless mode transfer is described. The proposed scheme employs a pulse-width-modulation (PWM) voltage-source inverter and has two operational modes. First, when the source voltage is normal, the system operates as an APF, which compensates for the harmonics and power factor while boosting the DC-link voltage to be ready for the disturbance, without an additional DC charging circuit. A simple algorithm to detect the load current harmonics is also proposed. Second, when the source voltage is out of the normal range (owing to sag, swell, or outage), it operates a UPS, which controls the output voltage constantly by discharging the DC-link capacitor. Furthermore, a seamless transfer method for the single-phase inverter between the APF mode and the UPS mode is also proposed, in which an IGBT switch with diodes is used as a static bypass switch. Dissimilar to a conventional SCR switch, the IGBT switch can implement a seamless mode transfer. During the UPS operation, when the source voltage returns to the normal range, the system operates as an APF. The proposed system has good transient and steady-state response characteristics. The APF, charging circuit, and UPS systems are implemented in one inverter system. Finally, the validity of the proposed scheme is investigated with simulated and experimental results for a prototype APF/UPS system rated at 3 kVA.

New Topology for Valve Performance Test Equipment of MMC based STATCOM (MMC 기반 STATCOM 용 밸브의 성능시험 장치를 위한 새로운 토폴로지)

  • Bae, Jongwoo;Jung, Jae-Hun;Nho, Eui-Cheol;Chung, Yong-Ho;Baek, Seung-Taek;Lee, Jin-Hee;Kim, Young-Woo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.1
    • /
    • pp.82-88
    • /
    • 2017
  • This study proposes a new topology for the performance test of a valve consisting of a modular multilevel converter (MMC)-based static synchronous compensator (STATCOM). The conventional valve performance test equipment requires high-voltage AC source of several kV rating because the number of submodules to be tested in a valve should be at least six or eight. However, the power source of the proposed scheme is DC and not AC source. The DC power source voltage range of the proposed test circuit is from several volts to several tens of volts. Therefore, the size and cost for the performance test equipment can be reduced considerably compared with the conventional method. The proposed scheme satisfies the requirements of the IEC 62927 standard. Simulations are conducted for a valve of 50[MVA] MMC-based STATCOM. Experimental results with a scale-downed setup show the validity of the proposed performance test topology.

Studies on the inhibitory substance of yeast growth (Part II ) Effect on the nitrogen uptake (항효모성 물질에 관한 연구 (제II보) 질소대사와의 관계)

  • 서정훈;송방호;유춘발
    • Microbiology and Biotechnology Letters
    • /
    • v.1 no.1
    • /
    • pp.3-11
    • /
    • 1973
  • The biochemical characteristics of Astradix -P, isolated from Astragalus membranaceus Bunge as yeaststatic substance, were reported on a previous paper. And on this report, some relation to the nitrogen metabolism of yeast was studied. Inorganic or organic source of nitrogen easily uptaking yeast did not show any antagonistic action to the inhibitory action of Astradix -P on the yeast growth. Especially an organic nitrogen source, arginine, histidine and lysine, classified to basic amino acid, was reacted as an antagonistic substance to the sample. But, ornithine, a basic amino acid, did not show any antagonistic action to the sample. In the mixed media containing neutral and acidic amino acids as a nitrogen source, yeast growth was inhibited strongly. If the basic amino acid was added to the same mixed media, the yeast growth was not inhibited by Astradix-P therefore, the antagonistic action of basic amino acid to the Astradix-p was readily observed. The yeast static action of Astradix-P was partially related to the isoelectric point of amino acid as a nitrogen source. Yeast cells which propagated under the media containing growth inhibitor, Astradix -p, did not bring any remarkable denaturation of cell structure by electro-microscopic observation.

  • PDF

Passivity-Based Control System of Permanent Magnet Synchronous Motors Based on Quasi-Z Source Matrix Converter

  • Cheng, Qiming;Wei, Lin
    • Journal of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.1527-1535
    • /
    • 2019
  • Because of the shortcomings of the PID controllers and traditional drive systems of permanent magnet synchronous motors (PMSMs), a PMSM passivity-based control (PBC) drive system based on a quasi-Z source matrix converter (QZMC) is proposed in this paper. The traditional matrix converter is a buck converter with a maximum voltage transmission ratio of only 0.866, which limits the performance of the driven motor. Therefore, in this paper a quasi-Z source circuit is added to the input side of the two-stage matrix converter (TSMC) and its working principle has also been verified. In addition, the controller of the speed loop and current loop in the conventional vector control of a PMSM is a PID controller. The PID controller has the problem since its parameters are difficult to adjust and its anti-interference capability is limited. As a result, a port controlled dissipative Hamiltonian model (PCHD) of a PMSM is established. Thereafter a passivity-based controller based on the interconnection and damping assignment (IDA) of a QZMC-PMSM is designed, and the stability of the equilibrium point is theoretically verified. Simulation and experimental results show that the designed PBC control system of a PMSM based on a QZMC can make the PMSM run stably at the rated speed. In addition, the system has strong robustness, as well as good dynamic and static performances.

The Seismic Source Parameters for Earthquakes Occurring in the Korean Peninsula (한반도 지진의 지진원 상수)

  • Kim, Sung-Kyun;Kim, Bung-Chul
    • Journal of the Korean earth science society
    • /
    • v.29 no.2
    • /
    • pp.117-127
    • /
    • 2008
  • Source parameters for forty four earthquakes which occurred in and around the Korean Peninsula were determined and the relations between them were studied. Snoke's method (Snoke, 1987) was applied in determining the corner frequencies and seismic moments. In general, the source parameters estimated at different stations for an earthquake show different values. These disagreements have been interpreted as originating, in principle, from an inadequate consideration of the source radiation pattern and direction dependent attenuation and amplification. The comer frequencies and seismic moments were averaged to exclude the such directional effects. Other source parameters were estimated from the mean corner frequency and seismic moment. The static stress drops, determined in this study, tend to be independent of seismic moment for events greater than a specific magnitude. For earthquakes with a size less than about $1.0{\times}10^{22}$ dyne-cm (nearly same as $M_L = 4.0$), the stress drop tends to decrease with the decreasing moment. This fact suggests a breakdown of the scaling law of source parameters in earthquakes below the threshold magnitude.

An Analysis of the Acoustical Source Characteristics in the Time-varying Fluid Machines (유체기계 덕트 내 시변 음원의 음향 특성에 관한 연구)

  • 장승호;이준신;이정권
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.2
    • /
    • pp.104-112
    • /
    • 2003
  • The in-duct acoustical sources of fluid machines are often characterized by the source impedance and strength using the linear time-invariant model. However, negative resistances, which are physically unreasonable, have been found throughout various measurements of the source properties in IC-engines and compressors. In this paper, the effects of the time-varying nature of fluid machines on the source characteristics are studied analytically. For this purpose, the simple fluid machine consisting of a reciprocating piston and an exhaust is considered as representing a typical periodic, time-varying system and the equivalent circuits are analyzed. Simulated measurements using the analytic solutions show that the time-varying nature in the actual sources is one of the main causes of the negative source resistances. It is also found that, for the small magnitude of the time-varying component, the source radiates large acoustic power if the piston operates at twice the natural frequency of the static system. or integral submultiples of that rate.

A Study on the Application of the DVR in AC Electric Traction System (전기철도계통에 순간전압강하 보상장치 적용에 관한 연구)

  • 최준호;김태수;김재철;문승일;남해곤;정일엽;박성우
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.95-104
    • /
    • 2003
  • The electric traction systems are quite differ from general power systems which is single-phase and heavy load. Therefore, there are inevitably power quality problems such as steady state or transient voltage drop, voltage imbalance and harmonic distortion. Among these problems, since steady-state volatge drop is the one of most important factor in electric power quality, many researches about on the compensation of volatge drop by using SVC(Static Var Compensator) and/or STACOM(Static Compensator) have been studied and proposed Also, it is expected that transient voltage drop(voltage sag) could affect the control and safety of high speed traction load. In this paper, voltage sag compensation of AT(Auto Transformer) feeding system are studied The detailed transient models of utility source, scott transformer, AT, and traction load are estabilished. The application of DVR(Dynamic Voltage Restorer) in electric traction system is proposed to compensate the voltage sag of traction network which is occured by the fault of utility source. It can be shown that application of the DVR in electric traction system is very useful to compensate the volatge sag from the result of related simulation works.

Analysis on the Reliability and Influence Factors of Refraction Traveltime Tomography Depending on Source-receiver Configuration (송수신기 배열에 따른 굴절 주시 역산의 영향 인자 및 신뢰성 분석)

  • Lee, Donguk;Park, Yunhui;Pyun, Sukjoon
    • Geophysics and Geophysical Exploration
    • /
    • v.20 no.3
    • /
    • pp.163-175
    • /
    • 2017
  • In land seismic exploration, irregular surface topography and weathering layer in near surface distorts the reflected signals of data. Therefore, typical land seismic data should be compensated for this distortion by static correction. To perform the static correction, near-surface velocity is required, which can be obtained by seismic refraction survey. However, land seismic data is often acquired in a limited form of geometry depending on the equipment availability, accessibility condition, and permission for the survey site. In this situation, refraction analysis should be performed using reflection data because it is impossible to acquire refraction-oriented data due to limited source and receiver geometry. In this study, we aimed to analyze the reliability of the results obtained by refraction traveltime tomography when using reflection data with a limited number of sources and receivers from irregular surface topography. By comparing the inversion result from irregular topography with that from flat surface, we found that the surface topography affects the reliability of the inversion results to some degree. We also found that the number of sources has little effect on the inversion results unless the number of sources are very small. On the other hand, we observed that velocity distortion occurred in the overlapped part of receiver arrays when using a limited number of receivers, and therefore suggested the size of the least overlapping ratio to avoid the velocity distortion. Finally, we performed numerical tests for the model which simulates the surface topography and acquisition geometry of the survey region and verified the reliability analysis of inversion results. We identified reliable areas and suspicious area of the inverted velocity model by applying the analysis results to field data.

Implementation of a Static Analyzer for Detecting the PHP File Inclusion Vulnerabilities (PHP 파일 삽입 취약성 검사를 위한 정적 분석기의 구현)

  • Ahn, Joon-Seon;Lim, Seong-Chae
    • The KIPS Transactions:PartA
    • /
    • v.18A no.5
    • /
    • pp.193-204
    • /
    • 2011
  • Since web applications are accessed by anonymous users via web, more security risks are imposed on those applications. In particular, because security vulnerabilities caused by insecure source codes cannot be properly handled by the system-level security system such as the intrusion detection system, it is necessary to eliminate such problems in advance. In this paper, to enhance the security of web applications, we develop a static analyzer for detecting the well-known security vulnerability of PHP file inclusion vulnerability. Using a semantic based static analysis, our vulnerability analyzer guarantees the soundness of the vulnerability detection and imposes no runtime overhead, differently from the other approaches such as the penetration test method and the application firewall method. For this end, our analyzer adopts abstract interpretation framework and uses an abstract analysis domain designed for the detection of the target vulnerability in PHP programs. Thus, our analyzer can efficiently analyze complicated data-flow relations in PHP programs caused by extensive usage of string data. The analysis results can be browsed using a JAVA GUI tool and the memory states and variable values at vulnerable program points can also be checked. To show the correctness and practicability of our analyzer, we analyzed the source codes of open PHP applications using the analyzer. Our experimental results show that our analyzer has practical performance in analysis capability and execution time.

Design of a New Op-Amp for Driving Large-Size LCD Panels (대면적 LCD 패널 구동을 위한 새로운 Op-Amp설계)

  • 이동욱;권오경
    • Proceedings of the IEEK Conference
    • /
    • 2000.06b
    • /
    • pp.133-136
    • /
    • 2000
  • A new Op-Amp output buffer is presented for driving large-size LCD panels. The proposed Op-Amp is designed by combining a common source and a common drain amplifier to have a high slew rate and to minimize the quiescent current. The proposed circuits are simulated in a high-voltage 0.6${\mu}{\textrm}{m}$ CMOS process, dissipates only 20${\mu}{\textrm}{m}$ static current, and have 83dB open-loop DC gain and 60$^{\circ}$phase margin.

  • PDF