• Title/Summary/Keyword: snubber

Search Result 411, Processing Time 0.025 seconds

Design of Current Source AC/DC Converter with Snubber Energy Recovery (스너버에너지회생형 전류형 전력변환기의 설계법)

  • Kim, Tae-Jin;Ise, Toshifumi;Park, Sung-Jun;Byun, Young-Bok;Kim, Cheul-U
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.345-347
    • /
    • 1996
  • Current source AC/DC converter with snubber energy recovery for high efficiency and high power converter was proposed. In this paper, design of the converter is presented. Voltage charged snubber condenser on commutation process is analyzed by theoretical analysis, simulation and experimental result.

  • PDF

Single-Stage Single-Switched AC/DC Converter with Magnetic Coupled Nondissipative Snubber (자기결합 무손실 스너버를 갖는 새로운 고역률 단일전력단 AC/DC 컨버터)

  • 조정욱;문건우;정영석;윤명중
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.423-431
    • /
    • 1997
  • A new single-stage/single-switched forward converter with magnetic coupled nondissipa-tive snubber is proposed. The proposed converter gives the good power factor correction (PFC), low current harmonic distortion, and tight output voltage regulation. The prototype shows the IEC 555-2 requirements are met satisfactorily with nearly unity power factor. This proposed converter with magnetic coupled nondissipative snubber is particularly suited for low power level power supply applications.

  • PDF

Optimal Snubber Design Strategy for the Resonant Inverter to Reduce RF Noise (공진형 인버터에 있어서 RF Noise 저감을 위한 Snubber 최적 회로 설계에 관한 연구)

  • Kim, Eun-Soo;Yoo, Dong-Wook;Oh, Sung-Chul;Lee, Jong-Moo
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.380-383
    • /
    • 1990
  • When the MOSPET is applied as a switching device for the resonant inverter, a damped oscillating noise is appeared at specific frequency band. This damped Oscillation is caused by the series and parallel resonance due to distributed circuit parameter of snubber and main circuit. This paper describes the frequency-impedance characteristic of the resonant inverter and optimal snubber design strategy to reduce the RF noise.

  • PDF

Soft Switching PWM Converter Using a New Active Snubber (새로운 액티브 스너버를 이용한 소프트 스위칭 PWM 컨버터)

  • Cho, M.C.;Kim, J.Y.;Mun, S.P.;Suh, K.Y.;Kwan, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.261-263
    • /
    • 2006
  • A new soft switched active snubber circuit is proposed to achieve zero voltage and zero current switching for all the switching devices in PWM DC-DC converters. The unique location of the snubber and inductor ensures low current/voltage stresses and commutation losses. With a saturable reactor, the conduction loss of auxiliary switch could be further minimized. A boost converter adopting this technique is presented as an example, to illuminate its operation principles and derive the design procedures. Simulation and hardware implementation have been made to validate its performance. Some other basic PWM DC-DC topologies using the proposed snubber have also been given.

  • PDF

The Vibration Characteristic of Optimizing Snubber of Reciprocating Type Hydrogen Compressor for Pressure Loss Reduction (압력 손실을 줄이기 위해 최적화된 왕복동식 수소 압축기용 완충기의 진동 특성 분석)

  • Kim, W.C.;Kim, H.J.;Jeong, J.H.;Jang, Y.S.;Choi, B.K.
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.8
    • /
    • pp.1116-1122
    • /
    • 2008
  • The reciprocating type hydrogen compressor has a pulsation due to the reciprocative characteristics which results in noise and vibration. Snubber is installed for the relaxation of pulsation, but it causes reduction of compressor efficiency because of pressure loss. Five types of snubber were modeled for the numerical investigation of the effect of the relative position of inlet and outlet and buffer angle on the pulsation amplitude and pressure loss. MSC/NASTRAN is used as a numerical tool to identify the vibration characteristic of each type. Frequency responses in forced vibration mode are compared for various cases and buffer angles.

A New ZVT-PWM Converter using Active Resonant Snubber (액티브 공진 스너버를 이용한 새로운 ZVT-PWM 컨버터)

  • Park, J.M.;Yoon, Y.T.;Kim, C.Y.;Kim, D.W.;Park, S.W.;Mun, S.P.;Suh, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.262-265
    • /
    • 2003
  • In this paper, a new active snubber circuit that overcomes most of the drawbacks of the normal "zero voltage transition pulse width modulation" (ZVT-PWM) converter is proposed to contrive a new family of ZVT- PWM converter. A converter with the proposed snubber circuit can also operate at light load conditions. A design procedure of the proposed active snubber circuit is also presented. Additionally, at full output power in the proposed soft switching converter, the main switch loss is about 27[%] and the total circuit loss is about 36[%] of that in its counterpart hard switching converter, and so the overall efficiency, which is about 91[%] in the hard switching case, increases to about 97[%].

  • PDF

The High Power AC-DC Buck Converter of High Efficienty Using Loss-Less Snubber (로스레스 스너버를 사용한 고효율의 대용량 AC-DC 강압형 컨버터)

  • 문상필;서기영;이현우
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.951-954
    • /
    • 1998
  • This paper proposed that a high power AC-DC buck converter topology of high efficiency using loss-less snubber operates with four chopper connecting a number of parallel circuit. To improve these, a large number of soft switching topologies included a resonant circuit have been proposed. And, some simulative resutls on computer is included to confirm the validity of the analytical results. The partial resonant circuit makes use of a inductor using step-down and a condenser of loss-less snubber. The result is that the switching loss is very low and the efficiency of system is high. And the snubber condenser used in partial resonant circuit makes charging energy regenerated at input power source of rresonant operation. The proposed conversion system is deemed the most suitable for high power applications where the power switching devices are used.

  • PDF

Soft switching high power factor buck converter using loss less snubber circuit (무손실 스너버 회로를 이용한 소프트 스위칭 강압형 고역률 컨버터)

  • 구헌회;변영복;김성철;서기영;이현우
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.6
    • /
    • pp.77-84
    • /
    • 1997
  • buck type converter doesn't appear when an input voltag eis lower than an output voltage. This is the main reason the buck converter has not been used for high power factor converters. In this paper, soft switching high power factor buck converter is proposed. This converter is composed of diode rectifier, input capacitor can be small enough to filter input current, buck converter with loss less snubber circuit. Converter is operated in discontinous conduction mode, turn on of the switching device is a zero current switching (ZCS) and high powr factor input is obtianed. In addition, zero voltage switching (ZVS) at trun off is achieved and switching loss is reduced using loss less snubber circuit. The capacitor used in the snubber circuit raised output voltage. Therefore, proposed converter has higher output voltage and higher efficiency than conventional buck type converter at same duty factor in discontinous conduction mode operation. High power factro, efficiency, soft switching operation of proposed converter is veified by simulation using Pspice and experimental results.

  • PDF

발전소 배관지지용 유압완충기 개발

  • Park, Tae-Jo;Koo, Chil-Hyo;Cho, Gwang-Hwan;Lee, Dong-Ryul;Lee, Hyun;Kim, Yeon-Hwan
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1997.10a
    • /
    • pp.232-238
    • /
    • 1997
  • In this paper, a theoretical method is presented to design a hydraulic control valve system that consist of an important component in the hydraulic snubber. The hydraulic snubber is used essentially to support the piping systems at power plants. To calculate the force due to pressure drop and flow rate in the valve orifice and by-pass hole, Bernoulli equation is used. The Reynolds equation are numerically analyzed in the clearance gap between the valve cone and valve seat to estimate the friction force and leakage flow rate. Based on the detailed theoretical data, we developed successfully the hydraulic snubber for power plants.

  • PDF

Buck converter using a non-dissipative snubber (탭-인덕터 적용 무손실 스너버에 의한 Buck 컨버터)

  • Park S. S.;Kong Y. S.;Yang S. C.;Kim E. S.
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.154-158
    • /
    • 2003
  • This paper presents an improved soft switching buck converter using a non-dissipative snubber, which is composed of a tapped inductor, two snubber capacitors and three snubber diodes. The proposed buck converter achieves zero voltage turn-off in the main switch and freewheeling diode. The Proposed Soft Switching buck converter is verified through the simulation, relevant equations, analysis and experimental results.

  • PDF