• Title/Summary/Keyword: small-scale H

Search Result 424, Processing Time 0.024 seconds

High-temperature Structural Analysis on the Small Scale PHE Prototype (소형 공정열교환기 시제품의 고온구조해석)

  • Song, Kee-nam;Lee, H-Y;Hong, S-D;Park, H-Y
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.6 no.1
    • /
    • pp.57-64
    • /
    • 2010
  • PHE(Process Heat Exchanger) is a key component required to transfer heat energy of $950^{\circ}C$ generated in a VHTR(Very High Temperature Reactor) to the chemical reaction that yields a large quantity of hydrogen. Korea Atomic Energy Research Institute established the gas loop for the performance test of components, which are used in the VHTR, and they manufactured a PHE prototype to be tested in the loop. In this study, as part of the high-temperature structural-integrity evaluation of the PHE prototype, which is scheduled to be tested in the gas loop, we carried out high-temperature structural-analysis modeling, thermal analysis, and thermal expansion analysis of the PHE prototype. The results obtained in this study will be used to design the performance test setup for the PHE prototype.

  • PDF

Fabrication and Characterization of Photo-Sensors for Very Small Scale Image System (초소형 영상시스템을 위한 광센서 제조 및 특성평가)

  • Shin, K.S.;Paek, K.K.;Lee, Y.S.;Lee, Y.H.;Park, J.H.;Ju, B.K.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.187-190
    • /
    • 2000
  • We fabricated general photo diode, surface etched photo diode and floating gate MOSFET by CMOS process. In a design stage, we expect that surface etched photo diode will be improved as to photo sensitivity. However, because the surface of silicon was damaged in etching process, the surface etched diode had a high dark current as well as low photo current level. Finally, we examined the current-voltage properties for the floating gate MOSFET on n-well and confirmed that the device can be act as an efficient photo-sensor. The floating gate MOSFET was operated in parasitic bipolar transistor mode.

  • PDF

Classification of Ellerman bombs

  • Kwak, Hannah;Chae, Jongchul
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.87.1-87.1
    • /
    • 2013
  • Ellerman bombs(EB) are small-scale bright features observed best in the wings of H alpha line. We used the Fast Imaging Solar Spectrograph(FISS) with the 1.6m New Solar Telescope at Big Bear Solar Observatory, in order to investigate characteristics of each EB. We analyzed H alpha line profiles of EBs, and classified EBs by their contrast profiles. To analyse characteristics of EBs, we applied power-law fitting ($C={\alpha}{\Delta}{\lambda}^{-n}$) to the EB contrast profiles. The amplitude ${\alpha}$ is a measure of the strength of an EB event (or the amount of released energy), and the power-law index n is a measure of spatial concentration of energy in the higher layers of the solar atmosphere. With the two parameters, we classified EBs into a few groups. We try to understand the physical properties of each group.

  • PDF

CFD Modeling of Unsteady Gas-Liquid Flow in a Small Scale Air-Lift Pump (소형 공기 양수 펌프의 불규칙한 가스-액체 흐름의 CFD 모델링)

  • Li, X.S.;Jeong, H.M.;Chung, H.S.
    • Journal of Power System Engineering
    • /
    • v.16 no.1
    • /
    • pp.30-37
    • /
    • 2012
  • 공기 양수 펌프는 재생 에너지 분야, 부식 및 마모 특성의 유체의 활용 등 높은 신뢰성과 낮은 유지보수 비용을 필요로 하는 분야에서 그 사용이 증대되고 있다. 본 연구에서는 소형 공기 양수 펌프의 성능 평가 및 기초 데이터를 얻기 위한 연구로, D=0.012~0.019m, L=0.933m인 배관의 침수 깊이(${\beta}$=0.55,0.60,0.65,0.70)에 따른 수치해석을 수행하였다. 수치 해석 및 실험 결과는 유사성을 뛰었으며, 펌프의 사양과 효율은 공기의 질량 유속 비, 침수 깊이 비와 양수 배관의 길이에 관한 함수로 나타났다. 그리고 최대 물과 공기 질량 유속의 비는 각 배관에서 서로 다른 침수 깊이의 비로 나타났으며, 공기 양수 펌프의 최대 효율이 발생되는 운전조건은 슬러그(slug)와 슬러그 교반 정도(slug-churn flow regime)에 따라 나타남을 알 수 있었다.

The operating characteristics of a small-scale residential PV power system (소규모 주택용 태양광 발전시스템의 운전 특성)

  • Ahn, K.S.;Lim, H.C.;Kang, B.S.;Hwang, I.H.;Kim, S.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1284-1286
    • /
    • 2001
  • In this paper, the operating characteristics of a 3 kW class grid-interactive photovoltaic(PV) power system was analysed from January 1998 to December 2000. The construction of the PV system includes a DC/AC inverter for grid connection, PV module, and data Monitoring & Acquisition system. The major results of the field test of the 3 kW class grid-interactive PV system showed that the system utilization rate was 13.83% the conversion efficiency of the inverter was 88% at an over half load, and the PV system generated the electricity more then 300 kWh per month.

  • PDF

Investigation on Forced Vibration Behavior of Composite Main Wing Structure Excited by Engine and Propeller (엔진 및 프로펠러 가진에 의한 위그선 복합재 날개 진동 해석)

  • Kong, Chang-Duk;Yoon, Jae-Huy;Park, Hyun-Bum
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.04a
    • /
    • pp.217-221
    • /
    • 2007
  • In this study, forced vibrations analysis was performed for main wing of small scale WIG vehicle which is equipped two-stroke pusher type propeller engine, in terms of structural. for the frequency response analysis, excitations were assumed by H-mode(Horizontal mode), X-mode(Twisted mode) which is main vibration mode of engine, and for the transient response analysis, excitations were assumed by L-mode(Longitudinal mode) with propeller thrust which is occurred when it revolution.

  • PDF

Fine-scale Spatial Genetic Structure of a Small Natural Stand of Populus davidiana in South Korea using AFLP markers (AFLP 마커를 이용한 소규모 사시나무림의 공간적 유전구조 구명)

  • Lee, Min Woo;Hong, Kyung Nak;Park, Yu Jin;Lee, Jei Wan;Lim, Hyo In
    • Journal of Korean Society of Forest Science
    • /
    • v.105 no.3
    • /
    • pp.309-314
    • /
    • 2016
  • A locally adapted plant population under harsh environmental changes might survive for a long generation through maintaining proper level of genetic diversity. When it happens losing the genetic diversity too much fast, the population could be declining and probably become extinct. An isolated small population of Populus davidiana was investigated to study out the genetic diversity and the fine-scale spatial genetic structure. The estimated number of adult trees in the population of Mt. Worak, South Korea, was 350 in the total area of $14,000m^2$. The number of adults in a study plot ($70m{\times}70m$) was 123. The average age was 16-year-old and a 32-year-old tree was the oldest. The distribution of individuals was slightly aggregated in the plot. Sixty-one among the 123 individuals were randomly sampled to estimate genetic variation using AFLP markers. One hundred fifty-one (77%) of total 196 amplicons were polymorphic from six AFLP primer combinations. The average number of loci per primer combination was 32.7 (S.D.=7.2). Expected heterozygosity ($H_e$) and Shannon's diversity index (S.I.) were 0.154 and 0.254, respectively. These values were extremely lower than those of other P. davidiana populations in South Korea. Genetic patchiness was showed within 21 meters by spatial autocorrelation analysis and the isolated small size of population might be mainly attributed to the formation of such small patch size.

An Investigation on Turbulent Flow Characteristics According to the Operating Loads of Three-Dimensional Small-Size Axial Fan by Large Eddy Simulation (대규모 와 모사에 의한 3차원 소형축류홴의 운전부하에 따른 난류유동 특성치 고찰)

  • Kim, Jang-Kweon;Oh, Seok-Hyung
    • Journal of Power System Engineering
    • /
    • v.20 no.1
    • /
    • pp.50-56
    • /
    • 2016
  • This paper handled an investigation on the turbulent flow characteristics of three-dimensional small-size axial fan(SSAF) according to operating loads. Also, it was carried out by unsteady-state, incompressible and three-dimensional large eddy simulation(LES). The downstream flow type of SSAF is changed from axial flow to radial flow around the beginning of stall region at the aerodynamic performance curve. Axial mean velocity component largely grows around blade tip at the operating point of A to D, but transverse and vertical mean velocity components as well as Reynolds shear stresses highly develop around blade tip at the operating point of E to H. On the other hand, the peak value of turbulent kinetic energy developed around blade tip shows the highest at the operating point of E.

Study on the Application of the Fenton Oxidation Method for Remediation of Small-scale Oil-contaminated Ballasts on Railroad Track (선로 내 소규모 유류오염도상자갈 정화를 위한 펜톤산화법의 적용성 연구)

  • Kwon, Tae-Soon;Lee, Jae-Young;Kim, Hee-Man;Jung, Woo-Sung;Kim, Jong-Heun
    • Journal of the Korean Society for Railway
    • /
    • v.18 no.5
    • /
    • pp.466-470
    • /
    • 2015
  • In this study, Fenton oxidation was applied to railroad track ballasts contaminated with small amounts of oil. In order to perform the experiment on Fenton oxidation, petroleum contaminated ballast was collected from the railroad track and experiments on major factors of the remediation process were implemented in the laboratory. Then, the feasibility of insitu Fenton oxidation was investigated for the railroad track that was partially contaminated with oil. As a result, the residual TPH concentration of ballast was reduced to about 1,000 mg/kg-ballast in laboratory experiments using 0.1 mol Fe/L $H_2O_2$. Due to the drainage structure of the track bed, a considerable amount of $H_2O_2$ was released below the ballast without the sufficient reaction with the contaminated ballast; therefore, additional studies are necessary for the effective field application of Fenton oxidation.

Corrosion of Fe-2%Mn-0.5%Si Steels at 600-800℃ in N2/H2O/H2S Atmospheres

  • Kim, Min-Jung;Park, Sang-Hwan;Lee, Dong-Bok
    • Journal of the Korean institute of surface engineering
    • /
    • v.44 no.5
    • /
    • pp.201-206
    • /
    • 2011
  • Fe-2%Mn-0.5%Si alloys were corroded at 600, 700 and $800^{\circ}C$ for up to 70 h in 1 atm of $N_2$ gas, or 1 atm of $N_2/H_2O$-mixed gases, or 1 atm of $N_2/H_2O/H_2S$-mixed gases. Oxidation prevailed in $N_2$ and $N_2/H_2O$ gases, whereas sulfidation dominated in $N_2/H_2O/H_2S$ gases. The oxidation/sulfidation rates increased in the order of $N_2$ gas, $N_2/H_2O$ gases, and, much more seriously, $N_2/H_2O/H_2S$ gases. The base element of Fe oxidized to $Fe_2O_3$ and $Fe_3O_4$ in $N_2$ and $N_2/H_2O$ gases, whereas it sulfidized to FeS in $N_2/H_2O/H_2S$ gases. The oxides or sulfides of Mn or Si were not detected from the XRD analyses, owing to their small amount or dissolution in FeS. Since FeS was present throughout the whole scale, the alloys were nonprotective in $N_2/H_2O/H_2S$ gases.