• 제목/요약/키워드: single unit

검색결과 1,795건 처리시간 0.024초

프레스 단동로봇의 개발 (A Development of Single Action Press Robot)

  • 허성창;황병복
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1997년도 춘계학술대회논문집
    • /
    • pp.261-264
    • /
    • 1997
  • A single action press robot, which consists of a driving unit, rotator, up-down feed base and feed bar, is developed and applied for the press automation. The driving unit is made up with a face cam and blade cam, which have a phase angle. The feeding system consists of a double speed-up apparatus and linear motion guides, and has a fast motion characteristics. A horizontal feeding speed of the feed bar is increased twice by the double speed-up apparatus. The driving mechanism could be simplified due to the speed-up of the feeding unit.

  • PDF

Gap comparison between single crown and three-unit bridge zirconia substructures

  • Anunmana, Chuchai;Charoenchitt, Masnisa;Asvanund, Chanavut
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권4호
    • /
    • pp.253-258
    • /
    • 2014
  • PURPOSE. To compare marginal and internal gaps of zirconia substructure of single crowns with those of three-unit fixed dental prostheses. MATERIALS AND METHODS. Standardized Co-Cr alloy simulated second premolar and second molar abutments were fabricated and subsequently duplicated into type-III dental stone for working casts. After that, all zirconia substructures were made using $Lava^{TM}$ system. Marginal and internal gaps were measured in 2 planes (mesial-distal plane and buccal-palatal plane) at 5 locations: marginal opening (MO), chamfer area (CA), axial wall (AW), cusp tip (CT) and mid-occlusal (OA) using Replica technique. RESULTS. There were significant differences between gaps at all locations. The $mean{\pm}SD$ of marginal gap in premolar was $43.6{\pm}0.4{\mu}m$ and $46.5{\pm}0.5{\mu}m$ for single crown and 3-unit bridge substructure respectively. For molar substructure the $mean{\pm}SD$ of marginal gap was $48.5{\pm}0.4{\mu}m$ and $52.6{\pm}0.4{\mu}m$ for single crown and 3-unit bridge respectively. The largest gaps were found at the occlusal area, which was $150.5{\pm}0.5{\mu}m$ and $154.5{\pm}0.4{\mu}m$ for single and 3-unit bridge premolar substructures respectively and $146.5{\pm}0.4{\mu}m$ and $211.5{\pm}0.4{\mu}m$ for single and 3-unit bridge molar substructure respectively. CONCLUSION. Independent-samples t-test showed significant differences of gap in zirconia substructure between single crowns and three-unit bridge (P<.001). Therefore, the span length has the effect on the fit of zirconia substructure that is fabricated using CAD/CAM technique especially at the occlusal area.

Single-Phase Self-Excited Induction Generator with Static VAR Compensator Voltage Regulation for Simple and Low Cost Stand-Alone Renewable Energy Utilizations Part I : Analytical Study

  • Ahmed, Tarek;Noro, Osamu;Soshin, Koji;Sato, Shinji;Hiraki, Eiji;Nakaoka, Mutsuo
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권1호
    • /
    • pp.17-26
    • /
    • 2003
  • In this paper, the comparative steady-state operating performance analysis algorithms of the stand-alone single-phase self-excited induction generator (SEIG) is presented on the basis of the two nodal admittance approaches using the per-unit frequency in addition to a new state variable de-fined by the per-unit slip frequency. The main significant features of the proposed operating circuit analysis with the per-unit slip frequency as a state variable are that the fast effective solution could be achieved with the simple mathematical computation effort. The operating performance results in the simulation of the single-phase SEIG evaluated by using the per-unit slip frequency state variable are compared with those obtained by using the per-unit frequency state variable. The comparative operating performance results provide the close agreements between two steady-state analysis performance algorithms based on the electro-mechanical equivalent circuit of the single-phase SEIG. In addition to these, the single-phase static VAR compensator; SVC composed of the thyristor controlled reactor; TCR in parallel with the fixed excitation capacitor; FC and the thyristor switched capacitor; TSC is ap-plied to regulate the generated terminal voltage of the single-phase SEIG loaded by a variable inductive passive load. The fixed gain PI controller is employed to adjust the equivalent variable excitation capacitor capacitance of the single-phase SVC.

고속 생산형 필름 진동판 성형기 및 금형 국산화 개발(I) - 단수 생산 진동판 성형기 - (Domestic Development of Vibrational Film Forming Machine and Die and Mold in the High Speed Production(I) - Single production forming machine -)

  • 김정현
    • 한국기계가공학회지
    • /
    • 제11권6호
    • /
    • pp.9-15
    • /
    • 2012
  • Vibrational film has been more employed in ear-phones or small type of speakers along with a wide use of portable multi-media equipments such as MP3 and MP4. However, the current hand work production process of diaphragms is inefficient. In this study, a die-and-mold and a single production forming machine are developed, and they result in a multi-production forming machine. The multi-production forming machine consists primarily of a film feeding unit and an unwinding unit. A vacuum suction device provides the film feeding unit, while the unwinding unit is obtained using an appropriate damper. The advantage of the developed single production forming machine is shown according to a proper voice test.

Evaluation of marginal and internal gaps in single and three-unit metal frameworks made by micro-stereolithography

  • Kim, Dong-Yeon;Lee, Ha-Na;Kim, Ji-Hwan;Kim, Hae-Young;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권4호
    • /
    • pp.239-243
    • /
    • 2017
  • PURPOSE. The purpose of this study is to compare single and three-unit metal frameworks that are produced by micro-stereolithography. MATERIALS AND METHODS. Silicone impressions of a selected molar and a premolar were used to make master abutments that were scanned into a stereolithography file. The file was processed with computer aided design software to create single and three-unit designs from which resin frameworks were created using micro-stereolithography. These resin frameworks were subjected to investment, burnout, and casting to fabricate single and three-unit metal ones that were measured under a digital microscope by using the silicone replica technique. The measurements were verified by means of the Mann-Whitney U test (${\alpha}=.05$). RESULTS. The marginal gap was $101.9{\pm}53.4{\mu}m$ for SM group and $104.3{\pm}62.9{\mu}m$ for TUM group. The measurement of non-pontics in a single metal framework was $93.6{\pm}43.9{\mu}m$, and that of non-pontics in a three-unit metal framework was $64.9{\pm}46.5{\mu}m$. The dimension of pontics in a single metal framework was $110.2{\pm}61.4{\mu}m$, and that of pontics in a three-unit metal framework was $143.7{\pm}51.8{\mu}m$. CONCLUSION. The marginal gap was smaller for the single metal framework than for the three-unit one, which requires further improvement before it can be used for clinical purposes.

화재 시 일체형 방화셔터 작동유무에 따른 초등학생의 피난특성 (The Evacuation Characteristics of Elementary School Student According to Working of Single Unit Fireproof Shutter for Fires)

  • 이승철;홍이표;김상일
    • 한국화재소방학회논문지
    • /
    • 제27권4호
    • /
    • pp.35-40
    • /
    • 2013
  • 본 연구는 일체형 방화셔터가 설치된 초등학교 학생의 피난특성에 관한 연구이다. 구체적인 방법으로 일체형 방화셔터를 포함한 방화셔터 전반에 대한 기초 자료를 수집 검토하였으며, 초등학교에 설치된 일체형 방화셔터 작동 유무에 따른 재실자 피난특성을 비교 분석하였다. 화재 모의실험 결과, 일체형 방화셔터 미작동시 최종 대피완료 시간은 130초이며, 일체형 방화셔터 작동 시에는 190초가 소요되었다. 그리고 일체형 방화셔터 작동 시 피난대피 상황에서 초등학생들이 셔터내의 출입문을 열지 못하는 상황이 발생되었다. 이러한 상황을 고려한다면 일체형 방화셔터 작동 시 최종피난 완료시간은 상당히 지연될 수 있고, 많은 학생들이 화재위험에 노출될 수 있다. 따라서 향후 일체형 방화셔터 출입문 개폐력에 대한 연구가 반드시 진행되어야 할 것으로 생각된다.

자동차 배터리 지지 구조의 진동 피로 해석에 대한 연구 (Study on Vibration Fatigue Analysis of Automotive Battery Supporter)

  • 안상호
    • 자동차안전학회지
    • /
    • 제11권4호
    • /
    • pp.22-27
    • /
    • 2019
  • In this paper, the vibration load and analysis results for automotive battery supporter were performed to provide efficient vibration tolerance performance prediction methods for single-product vibration tolerance testing, and the major influencing factors and considerations for setting up single-unit vibration tolerance tests were reviewed. A common applicable standard load was applied to efficiently predict the performance of single-unit vibrations through the frequency response analysis technique. The results similar to test results can be predicted by checking vulnerable parts of the vehicle components for vibration loads and applying scale factor to standard loads. In addition, it was confirmed that the test conditions with a frequency generating the same durability severity as the endurance test are needed for accurate prediction of the durability of the single-unit vibration tolerance test conditions, and the acceleration and frequency with the conditions that there is no significant nonlinear phenomena in the vibration system are established during the single-unit vibration tolerance test conditions.

CAD/CAM 시스템으로 제작한 지로코니아 코어의 변연 적합도 평가 (Evaluation on the Marginal Fitness of Zirconia Core fabricated with CAD/CAM System)

  • 노형록;선금주;주규지
    • 한국콘텐츠학회논문지
    • /
    • 제13권11호
    • /
    • pp.800-806
    • /
    • 2013
  • 본 연구의 목적은 CAD/CAM 시스템을 이용하여 지르코니아 코어를 제작한 다음 span의 길이가 변연 적합도에 미치는 영향과, 변연 간격이 임상적으로 허용 가능한 범위 내에 있는지를 평가하였다. 실험군은 지르코니아 single crown, 2-unit bridge, 3-unit bridge, 4-unit bridge의 4그룹으로 나누고 각 그룹별로 10개씩 코어를 제작하였다. 평균 변연 간격은 single $42.95{\pm}6.93{\mu}m$, 2-unit $43.53{\pm}5.27{\mu}m$, 3-unit $53.43{\pm}13.38{\mu}m$, 4-unit $50.85{\pm}8.25{\mu}m$으로 나타났다. 근심면, 원심면에서는 single, 2-unit 그룹과 3-unit, 4-unit 그룹 간 span의 길이 요인에 따라 통계학적으로 유의한 차이가 있는 것으로 나타났다(p<.05). 협면, 설면에서는 모든 그룹에서 span의 길이 요인에 따라 통계학적으로 유의한 차이가 없었다(p>.05). 이러한 결과는 지르코니아 코어의 span 길이가 변연 적합도에 영향을 주었고, 변연간격은 모든 그룹에서 임상적 허용 범위 내에 존재 하였다.

치과 캐드/캠 시스템으로 제작된 지르코니아 single 코핑과 3-unit 구조물의 상대적 적합도 비교 (Comparison of relative fitness between zirconia single coping and 3-unit fixed partial dentures (FPDs) manufactured by dental CAD/CAM system)

  • 이완선;박종경;김욱태
    • 구강회복응용과학지
    • /
    • 제30권1호
    • /
    • pp.16-22
    • /
    • 2014
  • 목적: 본 연구의 목적은 동일한 모형에서 제작된 지르코니아 single 코핑과 3-unit 구조물의 변연 및 내면 적합도를 평가하는 것이다. 연구 재료 및 방법: 상악 우측 제2소구치가 상실되고 상악 제1소구치와 제2대구치가 지대치로 형성된 에폭시 모형(epoxy model)을 제작한 후 레이저 스캐너를 이용하여 스캔 하였다. CAD 소프트웨어를 이용하여 지르코니아 구조물을 디자인하고 CAM을 사용하여 지르코니아 single 코핑과 3-unit 구조물을 제작 하였다. 지르코니아 single 코핑은 상악 제1소구치, 제2대구치에서 각각 10개씩 제작 되었고 지르코니아 3-unit 구조물도 10개가 제작 되었다. 적합도 측정을 위하여 제작된 실리콘 복제(silicone replica)를 4등분하고 각 면의 측정 위치(P1, P2, P3, P4, P5)에서 디지털 현미경을 사용하여 적합도를 측정하였다. 각 위치에서 측정된 불일치 값들은 변연 불일치(MG, P1), 축 불일치(AG, P2와 P3의 평균), 교합 불일치(OG, P4와 P5의 평균)의 세 범주로 분류하였다. 결과: Single 코핑에서 변연 불일치의 범위는 18.47 - 40.54 ${\mu}m$, 축 불일치의 범위는 39.73 - 73.61 ${\mu}m$, 교합 불일치의 범위는 116.90 - 134.69 ${\mu}m$이었다. 3-unit 구조물에서 변연 불일치의 범위는 45.95 - 87.44 ${\mu}m$이고, 축 불일치의 범위는 23.78 - 57.00 ${\mu}m$이고, 교합 불일치는 99.89 - 131.06 ${\mu}m$이었다. 결론: 본 연구의 결과에 따르면 single 코핑에 비해 3-unit 구조물의 변연 불일치가 증가하였지만 임상학적 수용 범위(- 120 ${\mu}m$) 내에 있었으며 3-unit 구조물의 불일치 증가를 방지하기 위해서 더욱 균질한 지르코니아 블록 사용과 소결공정들을 조절해야 할 것이다.

Multi-unit Level 1 probabilistic safety assessment: Approaches and their application to a six-unit nuclear power plant site

  • Kim, Dong-San;Han, Sang Hoon;Park, Jin Hee;Lim, Ho-Gon;Kim, Jung Han
    • Nuclear Engineering and Technology
    • /
    • 제50권8호
    • /
    • pp.1217-1233
    • /
    • 2018
  • Following a surge of interest in multi-unit risk in the last few years, many recent studies have suggested methods for multi-unit probabilistic safety assessment (MUPSA) and addressed several related aspects. Most of the existing studies though focused on two-unit nuclear power plant (NPP) sites or used rather simplified probabilistic safety assessment (PSA) models to demonstrate the proposed approaches. When considering an NPP site with three or more units, some approaches are inapplicable or yield very conservative results. Since the number of such sites is increasing, there is a strong need to develop and validate practical approaches to the related MUPSA. This article provides several detailed approaches that are applicable to multi-unit Level 1 PSA for sites with up to six or more reactor units. To validate the approaches, a multi-unit Level 1 PSA model is developed and the site core damage frequency is estimated for each of four representative multi-unit initiators, as well as for the case of a simultaneous occurrence of independent single-unit initiators in multiple units. For this purpose, an NPP site with six identical OPR-1000 units is considered, with full-scale Level 1 PSA models for a specific OPR-1000 plant used as the base single-unit models.