DOI QR코드

DOI QR Code

Evaluation on the Marginal Fitness of Zirconia Core fabricated with CAD/CAM System

CAD/CAM 시스템으로 제작한 지로코니아 코어의 변연 적합도 평가

  • 노형록 (전북대학교 바이오나노시스템공학과) ;
  • 선금주 (광주보건대학교 치기공과) ;
  • 주규지 (광주보건대학교 치기공과)
  • Received : 2013.08.14
  • Accepted : 2013.09.24
  • Published : 2013.11.28

Abstract

The purpose of this study was to evaluate the marginal fitnesses on the effect of span length of bridge and the marginal gaps within the clinically allowed range. The samples were fabricated with zirconia core using CAD/CAM system. The test groups were divided by four groups, single crown, 2-units bridge, 3-units bridge and 4-units bridge and 10 zirconia cores per each group. The results of mean marginal gaps were $42.95{\pm}6.93{\mu}m$ in the single crown, $43.53{\pm}5.27{\mu}m$ in 2-unit, $53.43{\pm}13.38{\mu}m$ in 3-unit, and $50.85{\pm}8.25{\mu}m$ in 4-unit on each. The marginal gap of mesial and distal surfaces were statistically significant differences between single, 2-unit group and 3-unit, 4-unit group (p<.05) and this results was effected by the span length. The buccal and lingual surfaces were no statistically significant differences within all groups(p>.05). From this results the span length of the zirconia core may have influence on marginal fitness and the marginal gaps were within the clinically allowed range.

본 연구의 목적은 CAD/CAM 시스템을 이용하여 지르코니아 코어를 제작한 다음 span의 길이가 변연 적합도에 미치는 영향과, 변연 간격이 임상적으로 허용 가능한 범위 내에 있는지를 평가하였다. 실험군은 지르코니아 single crown, 2-unit bridge, 3-unit bridge, 4-unit bridge의 4그룹으로 나누고 각 그룹별로 10개씩 코어를 제작하였다. 평균 변연 간격은 single $42.95{\pm}6.93{\mu}m$, 2-unit $43.53{\pm}5.27{\mu}m$, 3-unit $53.43{\pm}13.38{\mu}m$, 4-unit $50.85{\pm}8.25{\mu}m$으로 나타났다. 근심면, 원심면에서는 single, 2-unit 그룹과 3-unit, 4-unit 그룹 간 span의 길이 요인에 따라 통계학적으로 유의한 차이가 있는 것으로 나타났다(p<.05). 협면, 설면에서는 모든 그룹에서 span의 길이 요인에 따라 통계학적으로 유의한 차이가 없었다(p>.05). 이러한 결과는 지르코니아 코어의 span 길이가 변연 적합도에 영향을 주었고, 변연간격은 모든 그룹에서 임상적 허용 범위 내에 존재 하였다.

Keywords

References

  1. D. Suttor, K. Bunke, H. Hauptmann, and G. Hertlein, "LAVA- the system for all-ceramic $ZrO_2$ crown and frameworks," Int J Comput Dent, Vol.4, No.3, pp.195-206, 2001.
  2. U. C. Belser, M. I. MacEntee, W. A. Richter, "Fit of three porcelain-fused-to-metal marginal designs in vivo: a scanning electron microscope study," J Prosthet Dent, Vol.53, No.1, pp.24-29, 1885.
  3. D. A. Felton, B. E. Kanoy, S. C. Bayne, and G. P. Wirthman, "Effect of in vivo crown margin discrepancies on periodontal health," J Prosthet Dent, Vol.65, No.3, pp.357-364, 1991. https://doi.org/10.1016/0022-3913(91)90225-L
  4. J. A. Sorensen, "A standardized method for determination of crown margin fidelity," J Prosthet Dent, Vol.64, No.1, pp.18-24, 1990. https://doi.org/10.1016/0022-3913(90)90147-5
  5. M. Molin and S. Karlsson, "The fit of gold inlays and three ceramic inlay system. A clinical and invitro study," Acta Odontol Scand, Vol.51, No.4, pp.201-206, 1993. https://doi.org/10.3109/00016359309040568
  6. S. H. Hung, K. S. Hung, J. D. Eick, and R. Chappell, "Marginal fit of porcelain-fused-to-metal and two type of ceramic crown," J Prosthet Dent, Vol.63, No.1, pp.26-31, 1990. https://doi.org/10.1016/0022-3913(90)90260-J
  7. S. Reich, M. Wichmann, E. Nkenke, and P. Proeschel, "Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD/CAM system," Eur J Oral Sci, Vol.113, No.2, pp.174-179, 2005. https://doi.org/10.1111/j.1600-0722.2004.00197.x
  8. J. Abduo, K. Lyons, and M. Swain, "Fit of zirconia fixed partial denture: a systematic review," J Oral Rehabil, Vol.37, No.11, pp.866-876, 2010. https://doi.org/10.1111/j.1365-2842.2010.02113.x
  9. J. A. Sorensen, "A rationale for comparison of plaque-retaining properties of crown systems," J Prosthet Dent, Vol.62, No.3, pp.264-269, 1989. https://doi.org/10.1016/0022-3913(89)90329-6
  10. J. Y. Koo, J. H. Lim, and I. H. Cho, "Marginal fidelity according to the margin type of all ceramic crowns," J Korean Acad Prosthodont, Vol.35, No.3, pp.445-457, 1997.
  11. Y. Habib, E. Gerorges, M. Salim, S. Albert, and T. Khaldoun, "In vitro evaluation of the "Replica Technique" in the measurement of the fit of Procera crow," J Contemp Dent Pract, Vol.9, No.2, pp.25-32, 2008.
  12. J. W. McLean and J. A. Von Fraunhofer, "The estimation of cement film thickness by an in vivo techniqu," Br Dent J, Vol.131, No.3, pp.107-111, 1971. https://doi.org/10.1038/sj.bdj.4802708
  13. F. Beuer, H. Aggstaller, D. Edelhoff, and W. G. Gernet, "Marginal and internal fits of fixed dental prostheses zirconia retainers," Dent Mater, Vol.25, No.1, pp.94-102, 2009. https://doi.org/10.1016/j.dental.2008.04.018
  14. 김재홍, 김기백, "광간섭단층영상기를 이용한 치과용 지르코니아 코어의 적합도 분석", 한국콘텐츠논문지, 제12권, 제8호, pp.240-247, 2012. https://doi.org/10.5392/JKCA.2012.12.08.240