References
- Rosenblum MA, Schulman A. A review of all-ceramic restorations. J Am Dent Assoc 1997;128:297-307. https://doi.org/10.14219/jada.archive.1997.0193
- Magne P, Belser U. Esthetic improvements and in vitro testing of In-Ceram Alumina and Spinell ceramic. Int J Prosthodont 1997;10:459-66.
- Shepard FE, Moon PC, Grant GC, Fretwell LD. Allergic contact stomatitis from a gold alloy-fixed partial denture. J Am Dent Assoc 1983;106:198-9. https://doi.org/10.14219/jada.archive.1983.0381
- McLean JW, Hughes TH. The reinforcement of dental porcelain with ceramic oxides. Br Dent J 1965;119:251-67.
- Kelly JR, Tesk JA, Sorensen JA. Failure of all-ceramic fixed partial dentures in vitro and in vivo: analysis and modeling. J Dent Res 1995;74:1253-8. https://doi.org/10.1177/00220345950740060301
- Olsson KG, Furst B, Andersson B, Carlsson GE. A longterm retrospective and clinical follow-up study of In-Ceram Alumina FPDs. Int J Prosthodont 2003;16:150-6.
- Sorensen JA, Cruz M, Mito WT, Raffeiner O, Meredith HR, Foser HP. A clinical investigation on three-unit fixed partial dentures fabricated with a lithium disilicate glass-ceramic. Pract Periodontics Aesthet Dent 1999;11:95-106; quiz 108.
- Sorensen JA, Kang SK, Torres TJ, Knode H. In-Ceram fixed partial dentures: three-year clinical trial results. J Calif Dent Assoc 1998;26:207-14.
- Vult von Steyern P, Jonsson O, Nilner K. Five-year evaluation of posterior all-ceramic three-unit (In-Ceram) FPDs. Int J Prosthodont 2001;14:379-84.
- Libby G, Arcuri MR, LaVelle WE, Hebl L. Longevity of fixed partial dentures. J Prosthet Dent 1997;78:127-31. https://doi.org/10.1016/S0022-3913(97)70115-X
- Campbell SD, Sozio RB. Evaluation of the fit and strength of an all-ceramic fixed partial denture. J Prosthet Dent 1988; 59:301-6. https://doi.org/10.1016/0022-3913(88)90177-1
- Kelly JR. Dental ceramics: current thinking and trends. Dent Clin North Am 2004;48:viii, 513-30. https://doi.org/10.1016/j.cden.2004.01.003
- Denry I, Kelly JR. State of the art of zirconia for dental applications. Dent Mater 2008;24:299-307. https://doi.org/10.1016/j.dental.2007.05.007
- Abduo J, Lyons K, Swain M. Fit of zirconia fixed partial denture: a systematic review. J Oral Rehabil 2010;37:866-76. https://doi.org/10.1111/j.1365-2842.2010.02113.x
- Sailer I, Feher A, Filser F, Gauckler LJ, Luthy H, Hammerle CH. Five-year clinical results of zirconia frameworks for posterior fixed partial dentures. Int J Prosthodont 2007;20:383-8.
- Sailer I, Pjetursson BE, Zwahlen M, Hammerle CH. A systematic review of the survival and complication rates of all-ceramic and metal-ceramic reconstructions after an observation period of at least 3 years. Part II: Fixed dental prostheses. Clin Oral Implants Res 2007;18:86-96.
- Raigrodski AJ. Contemporary materials and technologies for all-ceramic fixed partial dentures: a review of the literature. J Prosthet Dent 2004;92:557-62. https://doi.org/10.1016/j.prosdent.2004.09.015
- Raigrodski AJ. Contemporary all-ceramic fixed partial dentures: a review. Dent Clin North Am 2004;48:viii, 531-44. https://doi.org/10.1016/j.cden.2003.12.008
- Devigus A, Lombardi G. Shading Vita YZ substructures: influence on value and chroma, part I. Int J Comput Dent 2004;7:293-301.
- Beuer F, Neumeier P, Naumann M. Marginal fit of 14-unit zirconia fixed dental prosthesis retainers. J Oral Rehabil 2009; 36:142-9. https://doi.org/10.1111/j.1365-2842.2008.01908.x
- Glauser R, Sailer I, Wohlwend A, Studer S, Schibli M, Scharer P. Experimental zirconia abutments for implant-supported single-tooth restorations in esthetically demanding regions: 4-year results of a prospective clinical study. Int J Prosthodont 2004;17:285-90.
- Lang NP, Kiel RA, Anderhalden K. Clinical and microbiological effects of subgingival restorations with overhanging or clinically perfect margins. J Clin Periodontol 1983;10:563-78. https://doi.org/10.1111/j.1600-051X.1983.tb01295.x
- Valderhaug J, Heloe LA. Oral hygiene in a group of supervised patients with fixed prostheses. J Periodontol 1977;48: 221-4. https://doi.org/10.1902/jop.1977.48.4.221
- Reich S, Wichmann M, Nkenke E, Proeschel P. Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD/CAM systems. Eur J Oral Sci 2005;113: 174-9. https://doi.org/10.1111/j.1600-0722.2004.00197.x
- Bindl A, Mormann WH. Marginal and internal fit of all-ceramic CAD/CAM crown-copings on chamfer preparations. J Oral Rehabil 2005;32:441-7. https://doi.org/10.1111/j.1365-2842.2005.01446.x
- Schaerer P, Sato T, Wohlwend A. A comparison of the marginal fit of three cast ceramic crown systems. J Prosthet Dent 1988;59:534-42. https://doi.org/10.1016/0022-3913(88)90065-0
- Hung SH, Hung KS, Eick JD, Chappell RP. Marginal fit of porcelain-fused-to-metal and two types of ceramic crown. J Prosthet Dent 1990;63:26-31. https://doi.org/10.1016/0022-3913(90)90260-J
- Weaver JD, Johnson GH, Bales DJ. Marginal adaptation of castable ceramic crowns. J Prosthet Dent 1991;66:747-53. https://doi.org/10.1016/0022-3913(91)90408-O
- Boening KW, Walter MH, Reppel PD. Non-cast titanium restorations in fixed prosthodontics. J Oral Rehabil 1992;19: 281-7. https://doi.org/10.1111/j.1365-2842.1992.tb01103.x
- Fransson B, Oilo G, Gjeitanger R. The fit of metal-ceramic crowns, a clinical study. Dent Mater 1985;1:197-9. https://doi.org/10.1016/S0109-5641(85)80019-1
- Kokubo Y, Ohkubo C, Tsumita M, Miyashita A, Vult von Steyern P, Fukushima S. Clinical marginal and internal gaps of Procera AllCeram crowns. J Oral Rehabil 2005;32:526-30. https://doi.org/10.1111/j.1365-2842.2005.01458.x
- Quintas AF, Oliveira F, Bottino MA. Vertical marginal discrepancy of ceramic copings with different ceramic materials, finish lines, and luting agents: an in vitro evaluation. J Prosthet Dent 2004;92:250-7. https://doi.org/10.1016/j.prosdent.2004.06.023
- Bornemann G, Lemelson S, Luthardt R. Innovative method for the analysis of the internal 3D fitting accuracy of Cerec-3 crowns. Int J Comput Dent 2002;5:177-82.
- Tuntiprawon M, Wilson PR. The effect of cement thickness on the fracture strength of all-ceramic crowns. Aust Dent J 1995;40:17-21. https://doi.org/10.1111/j.1834-7819.1995.tb05607.x
- Karlsson S. A clinical evaluation of fixed bridges, 10 years following insertion. J Oral Rehabil 1986;13:423-32. https://doi.org/10.1111/j.1365-2842.1986.tb01304.x
- Abduo J, Lyons K, Swain M. Fit of zirconia fixed partial denture: a systematic review. J Oral Rehabil 2010;37:866-76. https://doi.org/10.1111/j.1365-2842.2010.02113.x
- Reich S, Kappe K, Teschner H, Schmitt J. Clinical fit of fourunit zirconia posterior fixed dental prostheses. Eur J Oral Sci 2008;116:579-84. https://doi.org/10.1111/j.1600-0722.2008.00580.x
- Wettstein F, Sailer I, Roos M, Hammerle CH. Clinical study of the internal gaps of zirconia and metal frameworks for fixed partial dentures. Eur J Oral Sci 2008;116:272-9. https://doi.org/10.1111/j.1600-0722.2008.00527.x
Cited by
- Comparison of prosthetic models produced by traditional and additive manufacturing methods vol.7, pp.4, 2015, https://doi.org/10.4047/jap.2015.7.4.294
- Three Dimensional Analysis of Primary Maxillary Central and Lateral Anterior Zirconia Crown vol.43, pp.2, 2016, https://doi.org/10.5933/JKAPD.2016.43.2.176
- Role of span length in the adaptation of implant-supported cobalt chromium frameworks fabricated by three techniques vol.9, pp.2, 2017, https://doi.org/10.4047/jap.2017.9.2.124
- Functional aesthetic workflow. The success between tradition and innovation vol.84, pp.5, 2014, https://doi.org/10.1016/s0011-8524(16)30064-2
- A review of additive manufacturing in conservative dentistry and endodontics part 2: applications in restorative dentistry and endodontics vol.46, pp.3, 2019, https://doi.org/10.12968/denu.2019.46.3.248
- Marginal and internal fit of provisional crowns fabricated using 3D printing technology vol.28, pp.6, 2014, https://doi.org/10.3233/thc-191964
- Effect of Luting Cement and Convergence Angle of the Preparation on the Internal Fit of Zirconia Restorations vol.14, pp.24, 2014, https://doi.org/10.3390/ma14247858