• Title/Summary/Keyword: simple

Search Result 35,182, Processing Time 0.049 seconds

A Comparative study of Simple Tracing with Gothic Arch Tracing (Gothic arch tracing technique에 비교된 Simple tracing에 관한 연구)

  • Bae, Bong-Jin
    • Journal of Technologic Dentistry
    • /
    • v.2 no.1
    • /
    • pp.25-27
    • /
    • 1980
  • In the process of arranging artificial teeth the simple atracing technique was shown to be more precise and convenient for general use in dental clinic than gothic arch tracing. The simple tracing technique had some advantages over other ones in that they were very useful to check protrusive, lateral and central occlusion of mandible movement, and it was very easy to transfer the oral condition and mandible movements precisely onto the articulator. Also the technique was more effective than when using wax bite in that the functional movement range has shifted to 0.2 - 0.4mm form central occlusion.

  • PDF

ON GENERALIZED GRADED CROSSED PRODUCTS AND KUMMER SUBFIELDS OF SIMPLE ALGEBRAS

  • Bennis, Driss;Mounirh, Karim;Taraza, Fouad
    • Bulletin of the Korean Mathematical Society
    • /
    • v.56 no.4
    • /
    • pp.939-959
    • /
    • 2019
  • Using generalized graded crossed products, we give necessary and sufficient conditions for a simple algebra over a Henselian valued field (under some hypotheses) to have Kummer subfields. This study generalizes some known works. We also study many properties of generalized graded crossed products and conditions for embedding a graded simple algebra into a matrix algebra of a graded division ring.

ON THE INDEX AND BIDERIVATIONS OF SIMPLE MALCEV ALGEBRAS

  • Yahya, Abdelaziz Ben;Boulmane, Said
    • Communications of the Korean Mathematical Society
    • /
    • v.37 no.2
    • /
    • pp.385-397
    • /
    • 2022
  • Let (M, [ , ]) be a finite dimensional Malcev algebra over an algebraically closed field 𝔽 of characteristic 0. We first prove that, (M, [ , ]) (with [M, M] ≠ 0) is simple if and only if ind(M) = 1 (i.e., M admits a unique (up to a scalar multiple) invariant scalar product). Further, we characterize the form of skew-symmetric biderivations on simple Malcev algebras. In particular, we prove that the simple seven dimensional non-Lie Malcev algebra has no nontrivial skew-symmetric biderivation.

The Clinical Usefulness of Cephalometric Analysis in the Obstructive Sleep Apnea Syndrome (폐쇄성 수면 무호흡 증후군에서 두개골계측분석의 임상적 유용성)

  • Choi, Young-Mee;Lee, Sang-Haak;Kwon, Soon-Seog;Kim, Young-Kyoon;Kim, Kwan-Hyoung;Song, Jeong-Sup;Park, Sung-Hak;Moon, Hwa-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.2
    • /
    • pp.218-230
    • /
    • 1999
  • Background: Craniofacial anatomic abnormalities related to structural narrowing of the upper airway have been reported in patients with obstructive sleep apnea syndrome. In this study, we evaluated the craniofacial anatomic characteristics of Korean patients with obstructive sleep apnea syndrome, and the role of cephalometric analysis in the prediction of abnormal breathing during sleep. Methods: Thirty-nine patients with obstructive sleep apnea syndrome(OSAS), 39 simple snorers(simple snorers) and 20 controls(control) had cephalometric analysis using the technique of Riley et al, and underwent standardized polysomnographic recordings. Different variables, including sex, body mass index, cephalometric and polysomnographic data, were statistically analyzed. Results: Pm-UPW and V-LPW distances were significantly shorter in OSAS when compared with simple snorers or control. PAS in simple snorers was shorter than in control. ANS-Gn distance in OSAS was significantly longer than in control. PNS-P distance in OSAS or simple snorers was significantly longer than in control. MP-H distance in OSAS was significantly longer than in simple snorers or control and MP-H distance in simple snorers was also longer than in control. NL/Pm-P angle in OSAS was lesser than in control. MP-H distance in OSAS or in the combined groups of OSAS and simple snorers was significantly correlated with apneahypopnea index(AHI). PNS-P distance in the combined groups of OSAS and simple snorers was correlated with AHI. In male of all subjects, body mass index was significantly correlated with PNS-P or MP-H distance. Conclusion: Cephalometric analysis can be useful tool in determining the craniofacial anatomic abnormalities in patients with obstructive sleep apnea syndrome. Cephalometric parameters, especially MP-H distance, can be useful for predicting frequency of narrowing or obstruction of upper airway during sleep.

  • PDF

The Effects of Acupuncture(ST36. LI4) on the Colonic Transit Time in Chronic Constipation Patients

  • Lee Un Jung;Kim Dong Woung
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.17 no.1
    • /
    • pp.251-257
    • /
    • 2003
  • Background and Purpose : We were to investigate whether simple and electric acupuncture can affect the colonic transit time in both normal persons and chronic constipation patients. Methods: Twenty one volunteers were divided into two groups; first, normal control group(N=12) who had normal defecation habits, second, chronic constipation group(N=13). Before acupuncture, colonic transit time was checked using radio-opaque markers. Then simple acupuncture was done at four acupoints(both ST36, LI4) and maintained for 15 minutes during 4 days. Electric acupuncture was done using same methods except for applying 2Hz electrical stimulation. Result : In the normal group, after simple acupuncture, each transit time in the total, right, left was not changed statistic significance compared to pre-acupuncture(P>0.05), but which of rectosigmoid colon shortened statistic significance(P<0.05). After Electric acupuncture, transit time of right colon was shortened(P<0.05), and extended(P>0.05) in rectosigmoid colon compared to pre-acupuncture and simple acupuncture. In constipation group, after simple acupuncture, only rectosigmoid colonic transit time shortened statistic significance compared to pre-acupuncture(P<0.05). After electric acupuncture, also the transit time of rectosigmoid colon was shortened statistic significance compared to pre-acupuncture(P<0.05), but not to simple acupuncture(P>0.05). Conclusion : In normal persons without constipation, acupuncture affect the colonic transit time differently to the methods of it. In chronic constipation group, simple and electric acupuncture only reduces the rectosigmoid colonic transit time statistically significant(P<0.05).

Development of Test Method for Simple Shear and Prediction of Hardening Behavior Considering the Bauschinger Effect (단순전단 시험법 구축 및 바우싱거효과를 고려한 경화거동 예측)

  • Kim, Dongwook;Bang, Sungsik;Kim, Minsoo;Lee, Hyungyil;Kim, Naksoo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.10
    • /
    • pp.1239-1249
    • /
    • 2013
  • In this study we establish a process to predict hardening behavior considering the Bauschinger effect for zircaloy-4 sheets. When a metal is compressed after tension in forming, the yield strength decreases. For this reason, the Bauschinger effect should be considered in FE simulations of spring-back. We suggested a suitable specimen size and a method for determining the optimum tightening torque for simple shear tests. Shear stress-strain curves are obtained for five materials. We developed a method to convert the shear load-displacement curve to the effective stress-strain curve with FEA. We simulated the simple shear forward/reverse test using the combined isotropic/kinematic hardening model. We also investigated the change of the load-displacement curve by varying the hardening coefficients. We determined the hardening coefficients so that they follow the hardening behavior of zircaloy-4 in experiments.

Efficient Flooding Mechanisms with Considering Data Transmission Characteristics of the Wireless Sensor Network (무선 센서 네트워크의 데이터 전송 특성을 고려한 효율적인 플러딩 기법)

  • Ahn, Sang-Hyun;Lim, Yu-Jin;Kim, Mahn-Hee
    • The KIPS Transactions:PartC
    • /
    • v.16C no.2
    • /
    • pp.209-216
    • /
    • 2009
  • In the wireless sensor network, flooding is required for the dissemination of queries and event announcements. The simple flooding causes the implosion and the overlap problems, so the simple flooding may result in the reduced network lifetime. Therefore, in this paper, we propose the flooding overlay structure (FOS) so that the overhead caused by flooding can be reduced. We propose two variants of FOS mechanisms, the centralized FOS (CFOS) and the distributed FOS (DFOS). In CFOS, the sink collects the network topology information and selects forwarding nodes based on that information. On the other hand, DFOS allows each sensor node to decide whether to act as a forwarding node or not based on its local information. For the performance evaluation of our proposed mechanisms, we carry out NS-2 based simulations and compare ours with the simple flooding and the gossiping. The simulation results indicate that the proposed FOS mechanisms outperform the simple flooding in terms of the network lifetime and the gossiping in terms of the data delivery ratio.

Cartan Subalgebras of a Semi-restricted Lie Algebra

  • Choi, Byung-Mun
    • Journal of the Chungcheong Mathematical Society
    • /
    • v.6 no.1
    • /
    • pp.105-111
    • /
    • 1993
  • In this paper we show that if a semi-restricted Lie algebra L has an one dimensional toral Cartan subalgebra, then L is simple and $L\simeq_-sl(2)$ or $W(1:\underline{1})$. And we study that if L is simple but not simple and H is 2-dimensional, then H is a torus.

  • PDF

Simple PD+l-type fuzzy controller design

  • Kim, Jae-Hyoung;Kim, Ji-Hoon;Park, Bong-Yeol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.61.4-61
    • /
    • 2002
  • Introduction $\textbullet$ Simple PD-type Fuzzy Controller $\textbullet$ Simple PD+l-type fuzzy controller design $\textbullet$ Simulation $\textbullet$ Conclusion $\textbullet$ References

  • PDF

Simple Voltage Control of AC Motor (교류모터의 간단한 속도조정 방법)

  • Huang Yuhansan;Huang Jien
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.751-753
    • /
    • 1999
  • In this paper, a simple SR method of AC motor has introduced. The method achived by appling the Pulse-Width Modulation(PWM) method to control the ON and OFF time of motor. The method is simple, practicable and has no problem of shift and out of control which is existed in SR method of SCR.

  • PDF